Plan Review Details - Permit 21110249
Plan Review Stops For Permit 21110249 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2021-12-20 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-12-20 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-12-20 |
Time |
07:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-01-12 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-12 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-12 |
Time |
08:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-12-20 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-12-20 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-12-20 |
Time |
07:29 |
Sent To |
|
|
Notes |
2021-12-20 08:19:05 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | BUILDING REVIEW DENIED: | | | | THE FOLLOWING ITEMS ARE REQUIRED PRIOR TO ISSUANCE OF A | | DEMO PERMIT PER FLORIDA BUILDING | | CODE, BUILDING 3303: | | | | | | 3. UTILITY RELEASE - CITY OF WEST PALM BEACH WATER | | DEPARTMENT, REQUEST FOR METER PULL, ON | | THEIR FORM "DEMOLITION APPLICATION" | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | WATERDOWN METHOD: | | IF A WATER TRUCK IS DESIRED, PROVIDE DETAILED | | INFPRMATION OF THE WATER TRUCK SUCH AS: THE | | GALLON CAPACITY OF THE WATER TANK AND A LETTER | | INCLUDING A STATEMENT THAT THE WATER | | USED WILL BE POTABLE AND FROM AN OFF-SITE LOCATION ONLY | | AND WILL BE ON-SITE AT ALL TIMES | | DURING DEMOLITION. | | IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED, | | THEN A PARTIAL RELEASE WILL BE NOTED | | ON THEIR FORM. IF THE BACKFLOW PREVENTER DEVICE IS | | SELECTED, A PLUMBING PERMIT IS REQUIRED. BEFORE | | SCHEDULING THE 703(PLUMBING FINAL INSPECTION), THE | | BACKFLOW DEVICE NEEDS TO BE TESTED AND CERTIFIED BY | | THE CITY?S UTILITIES DEPT, 561-822-2244. FAX THE | | COMPLETED "DEMOLITION APPLICATION" FORM TO | | 561-822-2183. | | | | 4. SEWER LATERAL CAPPING PERMIT IS REQUIRED (SUBMIT | | APPLICATION TO BUILDING DIVISION); | | SCHEDULE A FINAL PLUMBING #703 FOR PERMIT # 21111288. | | | | | | | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2021-12-20 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2021-12-20 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2021-12-20 |
Time |
|
Sent To |
I |
|
Notes |
2021-12-20 12:01:29 | PASSED WITH PROVISOS: | | | | CALL FOR LOCATES, DIAL 811 BEFORE YOU DIG. FOR MORE | | INFO ON "CALL BEFORE YOU DIG", GO TO | | HTTP://WWW.SUNSHINE811.COM (REF: UNDERGROUND FACILITY | | DAMAGE PREVENTION AND SAFETY ACT, FLORIDA STATUTE, | | CHAPTER 556.) | | | | ADD NOTE TO SWPPP TO PROTECT STORM DRAIN INLETS IN | | VICINITY OF PROPERTY (OLIVE AVE., ETC.) WITH FILTER | | FABRIC OR OTHER BMPS | | | | ADDRESS ANY OTHER OUTSTANDING REVIEW COMMENTS. | | | | THANKS, | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, | | CITY OF WPB ENGINEERING SERVICES DEPARTMENT | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | (561) 246-9525 | | EMAIL: [email protected] | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING- | | STANDARDS-DETAILS | | CENTRAL OPERATIONS CENTER (DISPATCH): | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2021-12-15 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2021-12-15 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2021-12-15 |
Time |
08:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-01-12 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-12 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-11 |
Time |
08:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-12-21 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-12-21 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-12-09 |
Time |
06:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2021-12-20 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-12-20 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-12-20 |
Time |
07:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-12-15 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2021-12-15 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2021-12-15 |
Time |
08:51 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy