Plan Review Stops For Permit 21110017 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-11-01 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-11-01 |
Time |
12:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-14 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-13 |
Time |
18:28 |
Sent To |
|
|
Notes |
2022-07-14 10:22:50 | BUILDING AUDIT OK. JG. | | NOTE: NEW AWNINGS UNDER A SEPARATE PERMIT. | | SEE NOTE ON SHEET A3.20. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2022-06-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-06-22 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-06-22 |
Time |
09:08 |
Sent To |
|
|
Notes |
2022-06-22 10:49:15 | RESIDENTIAL (R3) ALTERATION FOURTH BUILDING AUDIT. | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #21110017 (GUEST HOUSE) | | | | NOTE: | | THIS IS A LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING | | BUILDING. SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | 1- OK. | | 2- OK. | | | | ORIGINAL COMMENT: | | 3- SECOND FLOOR BEDROOM EGRESS WINDOWS DON'T SEEM | | COMPLY WITH SEC. R310.2.1 FBC-RESIDENTIAL. REVISE AS | | REQUIRED. SHOW COMPLIANCE WITH MIN. CLEAR OPENINGS | | (WIDTH, HEIGHT AND TOTAL CLEAR OPENING). | | | | RESPONSE: | | REVISED DRAWING A1.10 IDENTIFIES THE WINDOW ON THE EAST | | SIDE OF THE SPIRAL STAIRS AS THE EGRESS WINDOW. THE | | SIZE OF THIS WINDOW IS 21048. | | EGRESS WINDOW DETAIL 4/A3.20 SHOWS A SINGLE HUNG WINDOW | | WITH 42'-8" WINDOW WIDTH DIMENSION AND 4'-8" WINDOW | | HEIGHT DIMENSION. | | | | IT LOOKS LIKE THIS WINDOW DOESN'T COMPLY WITH ALL THE | | EGRESS REQUIREMENTS BECAUSE: | | A) TYPICALLY, SINGLE HUNG IMPACT WINDOWS REQUIRE 63" | | +/- WINDOW HEIGHT IN ORDER TO GET THE REQUIRED 24" | | CLEAR HEIGHT OPENING. THE SPECIFIED WINDOW HEIGHT OF | | 56" DOESN'T SEEM TO COMPLY WITH THE CLEAR HEIGHT | | REQUIREMENT OF 24". REVISE EGRESS WINDOW SIZE | | SPECIFICATIONS TO COMPLY WITH ALL THE EGRESS | | REQUIREMENTS OR PROVIDE WINDOW MANUFACTURER'S CUT | | SHEETS SHOWING THAT THE SPECIFIED WINDOW SIZE WILL | | COMPLY. | | NOTE: CLEARLY SPECIFY SIZE OF WINDOW. SEE COMMENT | | BELOW. | | | | B)SIZE OF EGRESS WINDOW IS NOT CLEAR. FLOOR PLAN CALLS | | FOR 21048 WINDOW. WHAT IS THE CORRECT WIDTH OF THE | | WINDOW?. EGRESS WINDOW DETAIL 4/A3.20 SHOWS A SINGLE | | HUNG WINDOW WITH 42'-8" WINDOW WIDTH DIMENSION AND | | 4'-8" WINDOW HEIGHT DIMENSION. | | CLEARLY SPECIFY ON PLANS EXACT WINDOW WIDTH AND HEIGHT | | AND PROVIDE WINDOW MANUFACTURER'S CUT SHEETS SHOWING | | THAT THE SPECIFIED WINDOW WILL COMPLY WITH ALL THE | | CLEAR OPENING REQUIREMENTS. WIDTH, HEIGHT AND TOTAL | | CLEAR OPENING. | | | | 4-OK. | | | | ORIGINAL COMMENT: | | 5- PLANS DON'T PROVIDE ANY INFORMATION FOR THE NEW | | SPIRAL STAIR. | | UNABLE TO CHECK EGRESS. SEC. R311.7.10.1 | | FBC-RESIDENTIAL. SPECIFY STAIR SIZE AND TREAD AND | | RISERS DIMENSIONS. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS FOR CONSTRUCTION: FOOTING, | | ANCHORING, ETC. SEC. R301.1 FBC-RESIDENTIAL. | | | | PREVIOUS COMMENT: | | PLANS DON'T SPECIFY SIZE OF SPIRAL STAIR. UNABLE TO | | VERIFY EGRESS. | | ALSO, DETAIL 1 ON SHEET A3.20 DOESN'T SPECIFY THE | | HEIGHT OF THE STAIR HANDRAIL AND IT LOOKS LIKE THE | | STAIR HANDRAIL PICKETS SPACING DON'T COMPLY WITH THE | | OPENING LIMITATIONS OF SEC. R312.1.3 FBC-RESIDENTIAL. | | | | RESPONSE: | | REVISED DRAWING A3.20 ONLY ADDED NOTE STATING "NOTE: | | SEE SHEET 1 SPIRAL STAIR DETAILS AND SPECIFICATIONS". | | WHERE IS SHEET 1? | | NOTE: DESIGNER OF RECORD TO PROVIDE THIS INFORMATION. | | | | 6- OK. | | 7- OK. | | 8- OK. | | | | ORIGINAL COMMENT: | | 9- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR | | THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS | | AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL. | | | | PREVIOUS COMMENT: | | TYPICAL AWING DETAIL ON SHEET A3.20 DOESN'T PROVIDE | | COMPLETE FASTENING SPECIFICATIONS. DESIGNER OF RECORD | | TO PROVIDE THE INFORMATION TO SHOW COMPLIANCE WITH WIND | | DESIGN. SEC. R301.2.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. PROVIDE COMPLETE INFORMATION FOR CANOPY | | INSTALLATION OR PROVIDE COMPLETE INFORMATION UNDER A | | SEPARATE PERMIT. | | | | 10- OK. | | 11- OK. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-05-16 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-05-16 |
Time |
13:09 |
Sent To |
|
|
Notes |
2022-05-16 13:25:11 | RESIDENTIAL (R3) ALTERATION THIRD BUILDING AUDIT. | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #21110017 (GUEST HOUSE) | | | | NOTE: | | THIS IS A LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING | | BUILDING. SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | 1- OK. | | 2- OK. | | | | ORIGINAL COMMENT: | | 3- SECOND FLOOR BEDROOM EGRESS WINDOWS DON'T SEEM | | COMPLY WITH SEC. R310.2.1 FBC-RESIDENTIAL. REVISE AS | | REQUIRED. SHOW COMPLIANCE WITH MIN. CLEAR OPENINGS | | (WIDTH, HEIGHT AND TOTAL CLEAR OPENING). | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | UNABLE TO VERIFY EGRESS WINDOW. | | | | ORIGINAL COMMENT: | | 4- PLANS DON'T PROVIDE ANY INFORMATION ABOUT SECOND | | FLOOR WINDOW FALL PROTECTION. WINDOW FALL PROTECTION | | SHALL BE PROVIDED ON SECOND FLOOR WINDOWS WHERE THE TOP | | OF THE WINDOW SILL OF AN OPERABLE WINDOW IS LOCATED | | LESS THAN 24" ABOVE THE FINISHED FLOOR . SEC. R312.2 | | FBC RESIDENTIAL. | | NOTE: CLEARLY INDICATE THE WINDOW SILL HEIGHT OF SECOND | | FLOOR WINDOWS AND SPECIFY TYPE OF WINDOW FALL | | PROTECTION IF REQUIRED. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | UNABLE TO VERIFY IF WINDOW FALL PROTECTION IS REQUIRED | | | | ORIGINAL COMMENT: | | 5- PLANS DON'T PROVIDE ANY INFORMATION FOR THE NEW | | SPIRAL STAIR. | | UNABLE TO CHECK EGRESS. SEC. R311.7.10.1 | | FBC-RESIDENTIAL. SPECIFY STAIR SIZE AND TREAD AND | | RISERS DIMENSIONS. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS FOR CONSTRUCTION: FOOTING, | | ANCHORING, ETC. SEC. R301.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | PLANS DON'T SPECIFY SIZE OF SPIRAL STAIR. UNABLE TO | | VERIFY EGRESS. | | ALSO, DETAIL 1 ON SHEET A3.20 DOESN'T SPECIFY THE | | HEIGHT OF THE HANDRAIL AND IT LOOKS LIKE THE STAIR | | HANDRAIL PICKETS SPACING DON'T COMPLY WITH THE OPENING | | LIMITATIONS OF SEC. R312.1.3 FBC-RESIDENTIAL. | | | | 6- OK. | | 7- OK. | | 8- OK. | | | | ORIGINAL COMMENT: | | 9- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR | | THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS | | AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | TYPICAL AWING DETAIL ON SHEET A3.20 DOESN'T PROVIDE | | FASTENING SPECIFICATIONS. DESIGNER OF RECORD TO PROVIDE | | THE INFORMATION TO SHOW COMPLIANCE WITH WIND DESIGN. | | SEC. R301.2.1 FBC-RESIDENTIAL. | | | | 10- OK. | | 11- OK. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-04-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-04-22 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-04-22 |
Time |
14:51 |
Sent To |
|
|
Notes |
2022-04-22 16:26:57 | RESIDENTIAL (R3) ALTERATION SECOND BUILDING AUDIT. | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #21110017 (GUEST HOUSE) | | | | NOTE: | | THIS IS A LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING | | BUILDING. SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | 1- OK. | | 2- OK. | | | | ORIGINAL COMMENT: | | 3- SECOND FLOOR BEDROOM EGRESS WINDOWS DON'T SEEM | | COMPLY WITH SEC. R310.2.1 FBC-RESIDENTIAL. REVISE AS | | REQUIRED. SHOW COMPLIANCE WITH MIN. CLEAR OPENINGS | | (WIDTH, HEIGHT AND TOTAL CLEAR OPENING). | | | | RESPONSE: | | REPEAT COMMENT. NO ADDRESSED. UNABLE TO VERIFY EGRESS | | WINDOW. | | | | ORIGINAL COMMENT: | | 4- PLANS DON'T PROVIDE ANY INFORMATION ABOUT SECOND | | FLOOR WINDOW FALL PROTECTION. WINDOW FALL PROTECTION | | SHALL BE PROVIDED ON SECOND FLOOR WINDOWS WHERE THE TOP | | OF THE WINDOW SILL OF AN OPERABLE WINDOW IS LOCATED | | LESS THAN 24" ABOVE THE FINISHED FLOOR . SEC. R312.2 | | FBC RESIDENTIAL. | | NOTE: CLEARLY INDICATE THE WINDOW SILL HEIGHT OF SECOND | | FLOOR WINDOWS AND SPECIFY TYPE OF WINDOW FALL | | PROTECTION IS REQUIRED. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. UNABLE TO VERIFY IF | | WINDOW FALL PROTECTION IF REQUIRED | | | | ORIGINAL COMMENT: | | 5- PLANS DON'T PROVIDE ANY INFORMATION FOR THE NEW | | SPIRAL STAIR. | | UNABLE TO CHECK EGRESS. SEC. R311.7.10.1 | | FBC-RESIDENTIAL. SPECIFY STAIR SIZE AND TREAD AND | | RISERS DIMENSIONS. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS FOR CONSTRUCTION: FOOTING, | | ANCHORING, ETC. SEC. R301.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | PLANS DON'T SPECIFY SIZE OF SPIRAL STAIR. UNABLE TO | | VERIFY EGRESS. | | ALSO, DETAIL 1 ON SHEET A3.20 DOESN'T SPECIFY THE | | HEIGHT OF THE HANDRAIL AND IT LOOKS LIKE THE STAIR | | HANDRAIL PICKETS SPACING DON'T COMPLY WITH THE OPENING | | LIMITATIONS OF SEC. R312.1.3 FBC-RESIDENTIAL. | | | | 6- OK. | | 7- OK. | | 8- OK. | | | | ORIGINAL COMMENT: | | 9- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR | | THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS | | AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | TYPICAL AWING DETAIL ON SHEET A3.20 DOESN'T PROVIDE | | FASTENING SPECIFICATIONS. DESIGNER OF RECORD TO PROVIDE | | THE INFORMATION TO SHOW COMPLIANCE WITH WIND DESIGN. | | SEC. R301.2.1 FBC-RESIDENTIAL. | | | | 10- OK. | | 11- OK. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-12-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-12-16 |
Time |
17:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-12-16 |
Time |
14:08 |
Sent To |
|
|
Notes |
2021-12-16 17:57:41 | RESIDENTIAL (R3) ALTERATION BUILDING AUDIT. | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #21110017 | | | | NOTE: | | THIS IS A LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING | | BUILDING. SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | 1- PLANS DON'T SPECIFY CURRENT CODE AND THE DESIGN | | CRITERIA. SEC. 107.3.5.3 CITY AMENDMENTS. | | ARCHITECT TO PROVIDE ALL THE WIND DESIGN CRITERIA AS | | REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL. SPECIFY THE | | ULTIMATE AND NOMINAL WIND LOAD, BUILDING EXPOSURE, | | BUILDING MEAN ROOF HEIGHTT. ALSO, SPECIFY THE | | COMPONENTS AND CLADDING DESIGN PRESSURES FOR DOORS AND | | WINDOWS. | | | | 2- PLANS DON'T PROVIDE ANY STRUCTURAL | | DETAILS/SPECIFICATIONS. ARCHITECT NEEDS TO PROVIDE | | COMPLETE INFORMATION AS REQUIRED BY SEC. SEC. 107.3.5.3 | | CITY AMENDMENTS AND SEC. R301.1 FBC-RESIDENTIAL: | | | | A) PROVIDE COMPLETE OPENING FRAMING | | DETAILS/SPECIFICATIONS FOR NEW WINDOWS AND DOORS. | | SPECIFY ALL FRAMING MEMBERS SIZES AND CONNECTORS AT | | EACH END. | | | | B) PROVIDE COMPLETE FRAMING DETAILS/SPECIFICATIONS FOR | | NEW EXTERIOR WALLS AT NEW SPIRAL STAIR LOCATION AND | | INFILL WALL SECTIONS ON AREAS SHOWN ON PLANS. SPECIFY | | ALL FRAMING MEMBERS SIZES AND CONNECTORS AT EACH END. | | | | C)PROVIDE COMPLETE FRAMING DETAILS/SPECIFICATIONS AT | | SECOND FLOOR OPENING FOR NEW SPIRAL STAIRS AND INFILL | | FRAMING BY EXISTING STAIRCASE. SPECIFY ALL FRAMING | | MEMBERS SIZES AND CONNECTORS AT EACH END. | | | | 3- SECOND FLOOR BEDROOM EGRESS WINDOWS DON'T SEEM | | COMPLY WITH SEC. R310.2.1 FBC-RESIDENTIAL. REVISE AS | | REQUIRED. SHOW COMPLIANCE WITH MIN. CLEAR OPENINGS | | (WIDTH, HEIGHT AND TOTAL CLEAR OPENING). | | | | 4- PLANS DON'T PROVIDE ANY INFORMATION ABOUT SECOND | | FLOOR WINDOW FALL PROTECTION. | | WINDOW FALL PROTECTION SHALL BE PROVIDED ON SECOND | | FLOOR WINDOWS WHERE THE TOP OF THE WINDOW SILL OF AN | | OPERABLE WINDOW IS LOCATED LESS THAN 24" ABOVE THE | | FINISHED FLOOR . SEC. R312.2 FBC RESIDENTIAL. | | NOTE: CLEARLY INDICATE THE WINDOW SILL HEIGHT OF SECOND | | FLOOR WINDOWS AND SPECIFY TYPE OF WINDOW FALL | | PROTECTION IF REQUIRED. | | | | 5- PLANS DON'T PROVIDE ANY INFORMATION FOR THE NEW | | SPIRAL STAIR. | | UNABLE TO CHECK EGRESS. SEC. R311.7.10.1 | | FBC-RESIDENTIAL. SPECIFY STAIR SIZE AND TREAD AND | | RISERS DIMENSIONS. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS FOR CONSTRUCTION: FOOTING, | | ANCHORING, ETC. SEC. R301.1 FBC-RESIDENTIAL. | | | | 6- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR | | THE NEW SECOND FLOOR GUARDRAIL. | | PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE | | CONSTRUCTION OF GUARDRAIL SHOWING COMPLIANCE WITH TABLE | | R301.5, SEC. R312.1 FBC-RESIDENTIAL. | | | | 7- IT LOOKS LIKE WINDOW LOCATED ON THE SECOND FLOOR ON | | THE WEST SIDE ADJACENT TO THE NEW BEDROOM CLOSET NEEDS | | TO HAVE SAFETY GLAZING AS REQUIRED BY SEC. R308.4.2 | | FBC-RESIDENTIAL. SHOW COMPLIANCE. | | | | 8-PROVIDE COMPLETE WALL SECTION SPECIFYING WALL | | SHEATHING THICKNESS AND FASTENING, AND ALL EXTERIOR AND | | INTERIOR FINISHES. SEC. 107..3.5.3 CITY AMENDMENTS. | | ALSO, PROVIDE SPECIFICATIONS FOR THE REQUIRED TWO WATER | | RESISTIVE BARRIERS WHEN STUCCO IS APPLIED TO WOOD AS | | REQUIRED BY SEC. R703.7.3 FBC-RESIDENTIAL. | | | | 9- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR | | THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS | | AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL. | | | | 10-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | A)OUTSWING ENTRY DOOR AS SHOWN ON PLANS. | | | | 11-DESIGNER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. | | | | 12- WINDOW MULLIONS: NEITHER PLANS OR PRODUCT APPROVAL | | SUBMITTED SPECIFY SIZE OF MULLIONS TO BE USED. SPECIFY | | MULLIONS SIZE TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-07-14 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-07-14 |
Time |
13:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-12-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-12-15 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-12-15 |
Time |
12:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
6 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-07-14 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-07-14 |
Time |
14:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
5 |
Status |
P |
Date |
2022-06-16 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-06-16 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-06-16 |
Time |
15:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
4 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-04-05 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-04-05 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-03-08 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-03-08 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2021-11-23 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2021-11-23 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2021-11-23 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2021-11-05 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2021-11-05 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2021-11-05 |
Time |
11:50 |
Sent To |
|
|
Notes |
2021-11-05 11:51:15 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | NO DOCUMENTS | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | 561.822.1428 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2022-07-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-14 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-07-08 |
Time |
09:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2022-06-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-06-22 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-06-16 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-06-17 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-06-07 |
Time |
07:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-05-16 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-05-12 |
Time |
13:46 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-05-09 |
Time |
15:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2022-04-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-04-22 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-04-19 |
Time |
15:28 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2022-04-15 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-04-15 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-04-12 |
Time |
16:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2022-04-07 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-04-07 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-04-05 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-04-05 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-03-16 |
Time |
08:19 |
Sent To |
|
|
Notes |
2022-03-17 07:47:38 | NEW PRODUCT APPROVAL SUBMITTED TO 21110016, ROUTED TO | | Z/HIST |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-03-09 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-23 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-12-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-12-16 |
Time |
18:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-11-23 |
Time |
12:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-11-04 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2021-11-04 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2021-11-03 |
Time |
09:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2021-12-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-12-16 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-12-16 |
Time |
11:22 |
Sent To |
|
|
Notes |
2021-12-16 11:23:22 | NO MECHANICAL WORK SHOW ON PLANS FOR THIS PROJECT. ME |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-12-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-12-16 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-12-16 |
Time |
14:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
11 |
Status |
P |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-13 |
Time |
18:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-13 |
Time |
18:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
10 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-06-21 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-06-21 |
Time |
17:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
9 |
Status |
P |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2022-06-17 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2022-06-17 |
Time |
10:59 |
Sent To |
|
|
Notes |
2022-06-17 11:01:23 | PRIVATE PROVIDER PAPER WORK IS OK. THIS REVIEW IS FOR | | THE NTBO AND SUPPORTING DOCUMENTS ONLY. | | PLAN REVIEW AFFIDAVIT WILL BE HANDALED BY THE PLAN | | REVIEWER | | | | RICHARD GATHRIGHT | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
8 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-05-13 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2022-05-13 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
7 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2022-05-11 |
Time |
|
Sent To |
|
|
Notes |
2022-05-11 17:53:31 | SEE 21110017 |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
6 |
Status |
P |
Date |
2022-04-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-04-21 |
Time |
18:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-04-21 |
Time |
18:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
5 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-04-15 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2022-04-15 |
Time |
|
Sent To |
|
|
Notes |
2022-04-15 13:58:48 | PRIVATE PROVIDER AFFIDAVIT REVIEW | | | | 1) THE AFFIDAVIT LISTS SHEET A.20. THE SUBMITTED FILE | | A0.20 HAS DRAWING A1.20 IN IT. PLEASE CORRECT. | | | 2022-04-15 10:32:31 | PRIVATE PROVIDER AFFIDAVIT AUDIT | | | | | | 1) THE AFFIDAVIT SHOWS SHEET E1.10 DATED 05/04/2021. | | THE SUBMITTED SHEET E1.10 HAS A REVISION DATE | | 11/03/2021. PLEASE SHOW ON THE AFFIDAVIT THAT YOU HAVE | | REVIEWED THE MOST CURRENT VERSION OF THE DRAWING. | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
4 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-04-07 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2022-04-07 |
Time |
|
Sent To |
|
|
Notes |
2022-04-07 13:54:36 | PRIVATE PROVIDER AFFIDAVIT AUDIT | | | | 1) THE AFFIDAVIT SUBMITTED HAS A SHEET THAT IS NAMED | | A0.20, THERE IS NO SUCH SHEET IN THE DRAWING FOLDER | | THAT WAS SUBMITTED THIS CYCLE. THERE IS A SHEET A1.20 | | WHICH IS WHAT PULLS UP WHEN SHEET A0.20 IS CLICKED ON. | | THERE ARE 2- A1.20 SHEETS THAT HAVE BEEN SUBMITTED EACH | | WITH A DIFFERENT DATE. | | | | 2) THERE IS NO SHEET A0.00 SUBMITTED IN THE DRAWINGS | | FOLDER FOR THIS SUBMITTAL. | | | | 3) PRODUCT APPROVALS 33620.1 AND 34545.1 ARE ON THE | | AFFIDAVIT BUT ARE NOT IN THE SUPPORTING DOCUMENTS | | FOLDER THAT WAS SUBMITTED THIS CYCLE. | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
3 |
Status |
F |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-03-09 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-03-09 |
Time |
15:43 |
Sent To |
|
|
Notes |
2022-03-09 16:13:13 | PP AFFIDAVIT REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | BU1635 BN4338 | | ASFPM CFM US-21-11935 | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE: PLANS UNDER PERMIT 21110016. | | | | 1. SUBMIT AFFIDAVIT FOR THIS PERMIT (21110017) ADDRESS | | IS 217 WESTMINSTER RD | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
2 |
Status |
P |
Date |
2021-11-23 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2021-11-23 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2021-11-23 |
Time |
12:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2021-11-10 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2021-11-10 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2021-11-10 |
Time |
10:35 |
Sent To |
|
|
Notes |
2021-11-10 10:35:47 | PRIVATE PROVIDER REVIEW STOP PLAN REVIEW AND | | INSPECTIONS FAILED | | THERE ARE NO AFFIDAVITS SUBMITTED WITH THE NOTICE TO | | BUILDING OFFICIAL | | DOCUMENTS INCLUDED WERE NOTICE TO BUILDING OFFICIAL, | | COI, PRIVATE PROVIDER RESUME | | NO AFFIDAVITS OF CODE COMPLIANCE FOR THE PLAN REVIEW | | | | RICHARD GATHRIGHT | | ASSISTANT BUILDING OFFICIAL | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-13 |
Time |
19:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-13 |
Time |
19:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2022-06-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-06-22 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-06-22 |
Time |
08:58 |
Sent To |
|
|
Notes |
2022-06-22 08:59:49 | DIGITAL SIGNATURE REVIEW: | | | | 1- REVISED ARCHITECTURAL DRAWINGS SUBMITTED (COVER, | | A1.20, AS1.10, A1.10 HAVE A COPY OF A DIGITAL | | SIGNATURE. DIGITAL SIGNATURES ARE NOT ALLOWED TO BE | | PRINTED. ALL DOCUMENTS PREPARED BY A LICENSED ARCHITECT | | NEED TO HAVE THE ORIGINAL VERIFIABLE DIGITAL SIGNATURE | | OF THE ARCHITECT OF RECORD AS REQUIRED BY SEC. | | 61G1-16.003 F.A.C. AND CHAPTER 481 F.S. WHEN SUBMITTING | | PLANS/DOCUMENTS FOR PUBLIC RECORDS. | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE | | ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH | | ORIGINAL SEAL AND SIGNATURE. | | | | 2- REVISED STRUCTURAL DRAWINGS S1.01, S3.01 AND S3.01 | | SEEM TO HAVE A COPY OF A DIGITAL SIGNATURE. .ALL | | DOCUMENTS PREPARED BY A LICENSED ENGINEER NEED TO HAVE | | THE ORIGINAL VERIFIABLE DIGITAL SIGNATURE OF THE | | ENGINEER OF RECORD AS REQUIRED BY SEC. 61G15-23.004 FAC | | AND CHAPTER 471 F.S. | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE | | ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH | | ORIGINAL SEAL AND SIGNATURE. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-05-16 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-05-16 |
Time |
13:25 |
Sent To |
|
|
Notes |
2022-05-16 13:26:28 | DIGITAL SIGNATURE REVIEW: | | | | 1- REVISED ARCHITECTURAL DRAWINGS SUBMITTED (COVER, | | A1.20, AS1.10, A1.10 AND A3.20 HAVE A COPY OF A DIGITAL | | SIGNATURE. DIGITAL SIGNATURES ARE NOT ALLOWED TO BE | | PRINTED. ALL DOCUMENTS PREPARED BY A LICENSED ARCHITECT | | NEED TO HAVE THE ORIGINAL SEAL AND SIGNATURE OF THE | | ARCHITECT OF RECORD AS REQUIRED BY SEC. 61G1-16.005 FAC | | AND CHAPTER 481 F.S. WHEN SUBMITTING PLANS/DOCUMENTS | | FOR PUBLIC RECORDS. | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE | | ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH | | ORIGINAL SEAL AND SIGNATURE. | | | | | | STRUCTURAL DRAWINGS S1.01, S3.01 AND S3.01 WITH | | ENGINEER'S ORIGINAL SEAL/SIGNATURE ARE IN SIGNATURE | | FOLDER. JG. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2022-04-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-04-22 |
Time |
17:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-04-22 |
Time |
17:13 |
Sent To |
|
|
Notes |
2022-04-22 17:49:33 | DIGITAL SIGNATURE REVIEW: | | | | 1- NEW STRUCTURAL DRAWINGS S1.01, S3.01 AND S3.01 | | SUBMITTED SHOW THE ENGINEER'S SEAL WITH THE WORDS | | "CERTIFICATE". THIS TYPE OF SEAL IS NOT ALLOWED AS OF | | JANUARY OF 2006. ENGINEER NEEDS TO CHANGE THE SEAL TO | | READ "LICENSE". ENGINEER TO CONTACT FLORIDA BOARD OF | | PROFESSIONAL ENGINEERS FOR ANY QUESTIONS REGARDING THIS | | SEAL. | | FAC 61G15-23.001. | | | | 2- IT LOOKS LIKE NEW STRUCTURAL DRAWINGS S1.01, S3.01 | | AND S3.01 SUBMITTED HAVE A COPY OF A DIGITAL SIGNATURE. | | DIGITAL SIGNATURES ARE NOT ALLOWED TO BE PRINTED. ALL | | DOCUMENTS PREPARED BY A LICENSED ENGINEER NEED TO HAVE | | THE ORIGINAL SEAL AND SIGNATURE OF THE ENGINEER OF | | RECORD AS REQUIRED BY SEC. 61G15-23.003 FAC AND CHAPTER | | 471 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR PUBLIC | | RECORDS. | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE | | ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH | | ORIGINAL SEAL AND SIGNATURE. | | | | 3- IT LOOKS LIKE REVISED ARCHITECTURAL DRAWINGS | | SUBMITTED (COVER, A1.20, AS1.10, A1.10 AND A3.20 HAVE A | | COPY OF A DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE NOT | | ALLOWED TO BE PRINTED. ALL DOCUMENTS PREPARED BY A | | LICENSED ARCHITECT NEED TO HAVE THE ORIGINAL SEAL AND | | SIGNATURE OF THE ARCHITECT OF RECORD AS REQUIRED BY | | SEC. 61G1-16.005 FAC AND CHAPTER 481 F.S. WHEN | | SUBMITTING PLANS/DOCUMENTS FOR PUBLIC RECORDS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-12-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-12-16 |
Time |
18:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-12-16 |
Time |
17:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2022-06-16 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-06-16 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-06-16 |
Time |
15:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-04-05 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-04-05 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-03-08 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-03-08 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-11-23 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2021-11-23 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2021-11-23 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-11-05 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2021-11-05 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2021-11-05 |
Time |
11:51 |
Sent To |
|
|
Notes |
2021-11-05 11:51:53 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | NO DOCUMENTS | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | 561.822.1428 | | [email protected] | | |
|
|