Plan Review Stops For Permit 21110016 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-11-01 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-11-01 |
Time |
12:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-13 |
Time |
18:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-13 |
Time |
18:29 |
Sent To |
|
|
Notes |
2022-07-13 18:41:17 | BUILDING AUDIT OK. JG. | | NOTE: NEW AWNINGS UNDER A SEPARATE PERMIT. | | SEE NOTE ON SHEET A3.20. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2022-06-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-06-21 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-06-21 |
Time |
11:01 |
Sent To |
|
|
Notes |
2022-06-21 16:55:29 | RESIDENTIAL (R3) ALTERATION FOURTH BUILDING AUDIT. | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #21110016 (MAIN HOUSE) | | | | NOTE: | | THIS IS A LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING | | BUILDING. SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE. | | | | 1-OK. | | 2-OK. | | | | 3- NEW STAIRWAYS: | | A)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE | | CONSTRUCTION OF THE NEW STAIRWAYS SHOWING COMPLIANCE | | WITH SEC. R11.7 FBC-RESIDENTIAL. | | | | PREVIOUS COMMENT: | | (1)EAST SIDE STAIRS: CLARIFY TREAD DIMENSIONS. FLOOR | | PLAN SHOWS 48'-0" AND 96'-0" TREADS?. | | (NOTE: SEE SHEET A1.10. ALSO, TO AVOID MORE CONFLICTS | | AND UNNECESSARY DELAYS KEEP IN MIND THAT STAIRWAY | | LANDING CAN NOT BE LESS THAN 36" AND READ SEC. R311.7.5 | | FOR RISER AND TREAD REQUIREMENTS). | | | | RESPONSE: | | REPEAT COMMENT. REVISED PLAN SHOWS 2'-0" STAIR BOTTOM | | LANDING. THE MINIMUM BOTTOM LANDING DIMENSION OF 36" | | WAS NOT PROVIDED AS REQUESTED ON PREVIOUS COMMENT TO | | AVOID MORE DELAYS. REVISE AS REQUIRED. SEC. R11.7.6 | | FBC-RESIDENTIAL. | | | | 4- OK. | | 5- OK. | | 6- OK. | | | | 7- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR | | THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS | | AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL. | | | | PREVIOUS COMMENT: | | TYPICAL AWNING DETAIL ON SHEET A3.20 DOESN'T PROVIDE | | FASTENING SPECIFICATIONS. DESIGNER OF RECORD TO PROVIDE | | THE INFORMATION TO SHOW COMPLIANCE WITH WIND DESIGN. | | SEC. R301.2.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. PROVIDE COMPLETE INFORMATION FOR AWNING | | INSTALLATION OR PROVIDE COMPLETE INFORMATION UNDER A | | SEPARATE PERMIT. | | | | 8- OK. | | 9- OK. | | 10- OK. | | 11- OK. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-05-16 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-05-16 |
Time |
10:16 |
Sent To |
|
|
Notes |
2022-05-16 11:20:14 | RESIDENTIAL (R3) ALTERATION THIRD BUILDING AUDIT. | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #21110016 (MAIN HOUSE) | | | | NOTE: | | THIS IS A LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING | | BUILDING. SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE. | | | | 1-OK. | | 2-OK. | | | | 3- NEW STAIRWAYS: | | | | ORIGINAL COMMENT: | | A)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE | | CONSTRUCTION OF THE NEW STAIRWAYS SHOWING COMPLIANCE | | WITH SEC. R11.7 FBC-RESIDENTIAL. | | | | RESPONSE: | | (1) REPEAT COMMENT. NOT ADDRESSED. | | EAST SIDE STAIRS: CLARIFY TREAD DIMENSIONS. FLOOR PLAN | | SHOWS 48'-0" AND 96'-0" TREADS?. | | (NOTE: SEE SHEET A1.10. ALSO, TO AVOID MORE CONFLICTS | | AND UNNECESSARY DELAYS KEEP IN MIND THAT STAIRWAY | | LANDING CAN NOT BE LESS THAN 36" AND READ SEC. R311.7.5 | | FOR RISER AND TREAD REQUIREMENTS). | | | | (2)REPEAT COMMENT. NOT ADDRESSED. | | WEST SIDE STAIRS: FLOOR PLAN DOESN'T PROVIDE DIMENSIONS | | FOR LANDING AND TREADS. | | (NOTE: SEE SHEET A1.10. ALSO, TO AVOID MORE CONFLICTS | | AND UNNECESSARY DELAYS KEEP IN MIND THAT STAIRWAY | | LANDING CAN NOT BE LESS THAN 36" AND READ SEC. R311.7.5 | | FOR RISER AND TREAD REQUIREMENTS). | | | | 4- OK. | | 5- OK. | | 6- OK. | | | | ORIGINAL COMMENT: | | 7- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR | | THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS | | AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | TYPICAL AWING DETAIL ON SHEET A3.20 DOESN'T PROVIDE | | FASTENING SPECIFICATIONS. DESIGNER OF RECORD TO PROVIDE | | THE INFORMATION TO SHOW COMPLIANCE WITH WIND DESIGN. | | SEC. R301.2.1 FBC-RESIDENTIAL. | | | | 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | A)OK. | | | | ORIGINAL COMMENT: | | B) INSWING FRENCH DOORS AS SHOWN ON PLANS. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | ONLY PRODUCT APPROVAL FOR OUTSWING DOOR WAS SUBMITTED. | | | | 9- DESIGNER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT | | APPROVAL AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 10- OK. | | 11- OK. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | ********************************* |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-04-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-04-22 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-04-22 |
Time |
16:31 |
Sent To |
|
|
Notes |
2022-04-22 16:59:13 | RESIDENTIAL (R3) ALTERATION SECOND BUILDING AUDIT. | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #21110016 (MAIN HOUSE) | | | | NOTE: | | THIS IS A LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING | | BUILDING. SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE. | | | | 1-OK. | | 2-OK. | | | | 3- NEW STAIRWAYS: | | | | ORIGINAL COMMENT: | | A)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE | | CONSTRUCTION OF THE NEW STAIRWAYS SHOWING COMPLIANCE | | WITH SEC. R11.7 FBC-RESIDENTIAL. | | | | RESPONSE: | | (1) EAST SIDE STAIRS: CLARIFY TREAD DIMENSIONS. FLOOR | | PLAN SHOWS 48'-0" AND 96'-0" TREADS?. | | | | (2)WEST SIDE STAIRS: FLOOR PLAN DOESN'T PROVIDE | | DIMENSIONS FOR LANDING AND TREADS. | | | | 4- OK. | | 5- OK. | | 6- OK. | | | | ORIGINAL COMMENT: | | 7- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR | | THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS | | AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | TYPICAL AWING DETAIL ON SHEET A3.20 DOESN'T PROVIDE | | FASTENING SPECIFICATIONS. DESIGNER OF RECORD TO PROVIDE | | THE INFORMATION TO SHOW COMPLIANCE WITH WIND DESIGN. | | SEC. R301.2.1 FBC-RESIDENTIAL. | | | | 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | A)OK. | | | | ORIGINAL COMMENT: | | B) INSWING FRENCH DOORS AS SHOWN ON PLANS. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. ONLY PRODUCT APPROVAL | | FOR OUTSWING DOOR WAS SUBMITTED. | | | | 9- DESIGNER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT | | APPROVAL AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 10- OK. | | 11- OK. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | ********************************************* |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-12-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-12-17 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-12-16 |
Time |
13:58 |
Sent To |
|
|
Notes |
2021-12-17 10:58:03 | RESIDENTIAL (R3) ALTERATION BUILDING AUDIT. | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #21110016 | | | | NOTE: | | THIS IS A LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING | | BUILDING. SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE. | | | | 1-PLANS DON'T SPECIFY CURRENT CODE AND THE DESIGN | | CRITERIA. SEC. 107.3.5.3 CITY AMENDMENTS. | | ARCHITECT TO PROVIDE ALL THE WIND DESIGN CRITERIA AS | | REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL. SPECIFY THE | | ULTIMATE AND NOMINAL WIND LOAD, BUILDING EXPOSURE, | | BUILDING MEAN ROOF HEIGHT. ALSO, SPECIFY THE COMPONENTS | | AND CLADDING DESIGN PRESSURES FOR DOORS AND WINDOWS. | | | | 2- PLANS DON'T PROVIDE ANY STRUCTURAL | | DETAILS/SPECIFICATIONS. ARCHITECT NEEDS TO PROVIDE | | COMPLETE INFORMATION AS REQUIRED BY SEC. SEC. 107.3.5.3 | | CITY AMENDMENTS AND SEC. R301.1 FBC-RESIDENTIAL: | | | | A) PROVIDE COMPLETE OPENING FRAMING | | DETAILS/SPECIFICATIONS FOR NEW WINDOWS AND DOORS. | | SPECIFY ALL FRAMING MEMBERS SIZES AND CONNECTORS AT | | EACH END. | | | | 3- NEW STAIRWAYS: | | A)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE | | CONSTRUCTION OF THE NEW STAIRWAYS SHOWING COMPLIANCE | | WITH SEC. R11.7 FBC-RESIDENTIAL. | | | | B)A LANDING COMPLYING WITH SEC. R311.3 FBC-RESIDENTIAL | | IS REQUIRED IN THE STAIRWAY BY THE NEW DOUBLE FRENCH | | DOORS. | | | | C) HANDRAIL IS REQUIRED ON THE NEW STAIRWAY BY THE NEW | | DOUBLE FRENCH DOORS. | | SEC. R311.7.8 FBC-RESIDENTIAL | | | | 4-PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR | | THE GUARDRAIL AND HANDRAIL. | | PROVIDE COMPLETE DETAILS/SPECIFICATIONS SHOWING | | COMPLIANCE WITH TABLE R301.5, SEC. R312.1 | | FBC-RESIDENTIAL. | | | | 5- WINDOW ADJACENT TO THE SINGLE FRENCH DOOR NEEDS TO | | HAVE SAFETY GLAZING AS REQUIRED BY SEC. R308.4.2 | | FBC-RESIDENTIAL. SHOW COMPLIANCE. | | | | 6- PROVIDE COMPLETE WALL SECTION SPECIFYING WALL | | SHEATHING THICKNESS AND FASTENING, AND ALL EXTERIOR AND | | INTERIOR FINISHES. SEC. 107..3.5.3 CITY AMENDMENTS. | | ALSO, PROVIDE SPECIFICATIONS FOR THE REQUIRED TWO WATER | | RESISTIVE BARRIERS WHEN STUCCO IS APPLIED TO WOOD AS | | REQUIRED BY SEC. R703.7.3 FBC-RESIDENTIAL. | | | | 7- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR | | THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS | | AS SHOWN ON PLANS. PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL. | | | | 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | A)OUTSWING ENTRY DOOR AS SHOWN ON PLANS. | | | | B) INSWING FRENCH DOORS AS SHOWN ON PLANS. | | | | 9- DESIGNER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. | | | | 10- MULLION: NEITHER PLANS OR PRODUCT APPROVAL | | SUBMITTED SPECIFY SIZE OF MULLION TO BE USED BETWEEN | | THE FRENCH DOOR AND THE WINDOW AS SHOWN ON PLANS. | | SPECIFY MULLION SIZE TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL. | | | | 11- POOL AND POOL PAVERS ARE TO BE DONE UNDER SEPARATE | | PERMITS. SEC. 105.1 CITY AMENDMENTS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2022-11-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-07-14 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-07-14 |
Time |
11:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-12-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-12-15 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-12-15 |
Time |
11:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
5 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-07-14 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-07-14 |
Time |
11:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
4 |
Status |
P |
Date |
2022-06-16 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-06-16 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-06-16 |
Time |
15:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-04-05 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-04-05 |
Time |
14:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-03-08 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-03-08 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2021-11-10 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2021-11-05 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2021-11-10 |
Time |
16:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2022-07-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-14 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-07-08 |
Time |
09:28 |
Sent To |
|
|
Notes |
2022-07-13 09:33:36 | 7/13 DELETED LOCKED DOCUMENTS, DELETED DOCUMENTS IN | | SIGNATURE FOLDER (EXCEPT MOST CURRENT S&S STRUCTURAL | | DOCUMENT), ROUTED BACK TO AFFIDAVIT REVIEW AND BLDG | | DIVISION AUDIT SH | | | | | 2022-07-12 10:00:16 | PLEASE REFER TO PROJECTDOX INSTRUCTIONS. | | | | NOTHING SHOULD BE UPLOADED TO THE SIGNATURE FOLDER (SEE | | INSTRUCTIONS). ALL DOCUMENTS SHOULD BE UPLOADED TO | | DRAWINGS AND SUPPORTING DOCS. | | | | AT THIS POINT MANY DOCUMENTS HAVE BEEN LOCKED. | | COORDINATE WITH [email protected] TO DELETE ALL | | UNNECESSARY DOCUMENTS. | | | | IT APPEARS THAT A MULTIPAGE STRUCTURAL PDF WAS UPLOADED | | TO THE SIGNATURE FOLDER (ALONG WITH MANY OTHER | | DOCUMENTS). SEE PROJECTDOX INSTRUCTIONS, NOTHING SHOULD | | BE UPLOADED TO THIS FOLDER - THIS IS FOR STAFF USE | | ONLY. EACH PAGES SHOULD BE UPLOADED AS AN INDIVIDUAL | | PDF. IF THE ENGINEER REFUSES TO PROVIDE INDIVIDUALLY | | SIGNED PDFS, A SINGLE PDF CAN BE SUBMITTED AFTER ALL | | REVIEWS HAVE PASSED. | | | | THERE ARE NOW SIX DOCUMENTS IN SIGNATURE (SHOULD HAVE | | ZERO). COORDINATE WITH THE PERMIT LIBRARIANS TO HAVE | | THEM ALL DELETED. ANY REQUIRED DOCUMENTS SHOULD BE | | SUBMITTED TO THE SUPPORTING DOCS FOLDER (INCLUDING | | SIGNATURE DOCUMENTS, CLEARLY NAMED). | | | | DUE TO THE WAY FILES ARE NAMED, THEY DO NOT APPEAR IN | | ORDER. THEY APPEAR AS PAGE 1, P10, PAGE 11, P2, P13, | | P2. THIS IS WHY A DOUBLE OR TRIPLE DIGIT PREFIX IS | | REQUIRED, SEE PROJECTDOX INSTRUCTIONS. FOR INSTANCE, | | FILE NAMED 10_E1_.10R.PDF. THIS DOES NOT HAVE TO BE | | FIXED FOR THIS SUBMITTAL, BUT BE ADVISED THAT FUTURE | | SUBMITTALS MUST FOLLOW THE NAMING CONVENTION. | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2022-06-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-06-21 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-06-16 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-06-17 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-06-07 |
Time |
07:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-05-16 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-05-12 |
Time |
13:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-05-09 |
Time |
15:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2022-04-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-04-22 |
Time |
17:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-04-19 |
Time |
15:27 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2022-04-15 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-04-15 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-04-12 |
Time |
16:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-04-07 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-04-07 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-03-16 |
Time |
08:19 |
Sent To |
|
|
Notes |
2022-03-17 07:45:55 | NEW PRODUCT APPROVAL SUBMITTED, ROUTED TO Z/HIST |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-03-09 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-23 |
Time |
08:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-12-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-12-17 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-11-22 |
Time |
11:31 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-11-04 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2021-11-04 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2021-11-03 |
Time |
09:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2021-12-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-12-16 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-12-16 |
Time |
11:20 |
Sent To |
|
|
Notes |
2021-12-16 11:21:17 | NO MECHANICAL WORK SHOWN ON THE PLANS. ME |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2021-12-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-12-15 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-12-15 |
Time |
15:16 |
Sent To |
|
|
Notes |
2021-12-17 07:21:07 | NO PLUMBING WORK IN MAIN HOUSE. WORK IN GUEST HOUSE | | UNDER PERMIT 21110017. |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
11 |
Status |
P |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-13 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-13 |
Time |
17:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
10 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-06-21 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-06-21 |
Time |
14:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
9 |
Status |
P |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2022-06-17 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2022-06-17 |
Time |
10:25 |
Sent To |
|
|
Notes |
2022-06-17 10:26:57 | PRIVATE PROVIDER PAPER WORK IS OK. THIS REVIEW IS FOR | | THE NTBO AND SUPPORTING DOCUMENTS ONLY. | | PLAN RVIEW AFFIDAVIT WILL BE HANDLED BY THE PLAN | | REVIEWER | | | | RICHARD GATHRIGHT |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
8 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-05-13 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2022-05-13 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
7 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2022-05-11 |
Time |
|
Sent To |
|
|
Notes |
2022-05-11 17:52:08 | FS553.791, AN ACCURATE AFFIDAVIT IS REQUIRED PRIOR TO | | ROUTING TO BUILDING DIVISION AUDIT. | | | | TWO DOCUMENTS WERE SUBMITTED BY THE PRIVATE PROVIDER | | BUT DO NOT APPEAR ON THE AFFIDAVIT - TREMCO EXOAIR, | | DYMONIC 100. IF THESE DOCUMENTS ARE TO BE INCLUDED IN | | THE PERMIT SET, THEY NEED TO BE INCLUDED ON THE | | AFFIDAVIT. IF THEY ARE NOT REQUIRED, IT IS NOT CLEAR | | WHY THE PRIVATE PROVIDER SUBMITTED THEM. EITHER REVISE | | AFFIDAVIT TO INCLUDE OR EMAIL [email protected] | | AND REQUEST THAT THEY BE DELETED/LOCKED. | | | | CHECK ALL. AFFIDAVIT IS TO MATCH THE DOCUMENTS | | SUBMITTED. | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
6 |
Status |
P |
Date |
2022-04-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-04-21 |
Time |
18:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-04-21 |
Time |
17:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
5 |
Status |
F |
Date |
2022-04-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-04-15 |
Time |
|
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-04-15 |
Time |
12:41 |
Sent To |
|
|
Notes |
2022-04-15 12:48:13 | PRIVATE PROVIDER AFFIDAVIT REVIEW | | | | 1) THE AFFIDAVIT LISTS SHEET A.20. THE SUBMITTED FILE | | A0.20 HAS DRAWING A1.20 IN IT. PLEASE CORRECT. | | | 2022-04-15 10:30:00 | PRIVATE PROVIDER AFFIDAVIT AUDIT | | | | | | 1) THE AFFIDAVIT SHOWS SHEET E1.10 DATED 05/04/2021. | | THE SUBMITTED SHEET E1.10 HAS A REVISION DATE | | 11/03/2021. PLEASE SHOW ON THE AFFIDAVIT THAT YOU HAVE | | REVIEWED THE MOST CURRENT VERSION OF THE DRAWING. | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
4 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-04-07 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2022-04-07 |
Time |
|
Sent To |
|
|
Notes |
2022-04-07 13:56:09 | PRIVATE PROVIDER AFFIDAVIT AUDIT | | | | 1) THE AFFIDAVIT SUBMITTED HAS A SHEET THAT IS NAMED | | A0.20, THERE IS NO SUCH SHEET IN THE DRAWING FOLDER | | THAT WAS SUBMITTED THIS CYCLE. THERE IS A SHEET A1.20 | | WHICH IS WHAT PULLS UP WHEN SHEET A0.20 IS CLICKED ON. | | THERE ARE 2- A1.20 SHEETS THAT HAVE BEEN SUBMITTED EACH | | WITH A DIFFERENT DATE. | | | | 2) THERE IS NO SHEET A0.00 SUBMITTED IN THE DRAWINGS | | FOLDER FOR THIS SUBMITTAL. | | | | 3) PRODUCT APPROVALS 33620.1 AND 34545.1 ARE ON THE | | AFFIDAVIT BUT ARE NOT IN THE SUPPORTING DOCUMENTS | | FOLDER THAT WAS SUBMITTED THIS CYCLE. | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
3 |
Status |
F |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-03-09 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-03-09 |
Time |
10:30 |
Sent To |
|
|
Notes |
2022-03-09 15:42:27 | PP AFFIDAVIT REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | BU1635 BN4338 | | ASFPM CFM US-21-11935 | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. DOCUMENTS LISTED ON AFFIDAVIT BUT NOT SUBMITTED FOR | | REVIEW: | | FL 34006.4 (FRENCH DOORS) AND PLAN PAGE A2.20. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
2 |
Status |
P |
Date |
2021-11-23 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2021-11-23 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2021-11-23 |
Time |
10:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2021-11-10 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2021-11-10 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2021-11-10 |
Time |
10:30 |
Sent To |
|
|
Notes |
2021-11-10 10:34:25 | PRIVATE PROVIDER REVIEW STOP PLAN REVIEW AND | | INSPECTIONS FAILED | | THERE ARE NO AFFIDAVITS SUBMITTED WITH THE NOTICE TO | | BUILDING OFFICIAL | | DOCUMENTS INCLUDED WERE NOTICE TO BUILDING OFFICIAL, | | COI, PRIVATE PROVIDER RESUME | | NO AFFIDAVITS OF CODE COMPLIANCE FOR THE PLAN REVIEW | | | | RICHARD GATHRIGHT | | ASSISTANT BUILDING OFFICIAL | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-13 |
Time |
19:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-13 |
Time |
19:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2022-06-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-06-21 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-06-21 |
Time |
16:56 |
Sent To |
|
|
Notes |
2022-06-21 17:10:51 | DIGITAL SIGNATURE REVIEW: | | | | 1- REVISED ARCHITECTURAL DRAWINGS SUBMITTED (COVER, | | A1.20, AS1.10, A1.10 HAVE A COPY OF A DIGITAL | | SIGNATURE. DIGITAL SIGNATURES ARE NOT ALLOWED TO BE | | PRINTED. ALL DOCUMENTS PREPARED BY A LICENSED ARCHITECT | | NEED TO HAVE THE ORIGINAL VERIFIABLE DIGITAL SIGNATURE | | OF THE ARCHITECT OF RECORD AS REQUIRED BY SEC. | | 61G1-16.003 F.A.C. AND CHAPTER 481 F.S. WHEN SUBMITTING | | PLANS/DOCUMENTS FOR PUBLIC RECORDS. | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE | | ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH | | ORIGINAL SEAL AND SIGNATURE. | | | | 2- REVISED STRUCTURAL DRAWINGS S1.01, S3.01 AND S3.01 | | SEEM TO HAVE A COPY OF A DIGITAL SIGNATURE. .ALL | | DOCUMENTS PREPARED BY A LICENSED ENGINEER NEED TO HAVE | | THE ORIGINAL VERIFIABLE DIGITAL SIGNATURE OF THE | | ENGINEER OF RECORD AS REQUIRED BY SEC. 61G15-23.004 FAC | | AND CHAPTER 471 F.S. | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE | | ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH | | ORIGINAL SEAL AND SIGNATURE. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-05-16 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-05-16 |
Time |
11:20 |
Sent To |
|
|
Notes |
2022-05-16 11:26:58 | DIGITAL SIGNATURE REVIEW: | | | | 1- REVISED ARCHITECTURAL DRAWINGS SUBMITTED (COVER, | | A1.20, AS1.10, A1.10 AND A3.20 HAVE A COPY OF A DIGITAL | | SIGNATURE. DIGITAL SIGNATURES ARE NOT ALLOWED TO BE | | PRINTED. ALL DOCUMENTS PREPARED BY A LICENSED ARCHITECT | | NEED TO HAVE THE ORIGINAL SEAL AND SIGNATURE OF THE | | ARCHITECT OF RECORD AS REQUIRED BY SEC. 61G1-16.005 FAC | | AND CHAPTER 481 F.S. WHEN SUBMITTING PLANS/DOCUMENTS | | FOR PUBLIC RECORDS. | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE | | ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH | | ORIGINAL SEAL AND SIGNATURE. | | | | | | STRUCTURAL DRAWINGS S1.01, S3.01 AND S3.01 WITH | | ENGINEER'S ORIGINAL SEAL/SIGNATURE ARE IN SIGNATURE | | FOLDER. JG. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2022-04-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-04-22 |
Time |
17:50 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-04-22 |
Time |
17:50 |
Sent To |
|
|
Notes |
2022-04-22 17:50:59 | DIGITAL SIGNATURE REVIEW: | | | | 1- NEW STRUCTURAL DRAWINGS S1.01, S3.01 AND S3.01 | | SUBMITTED SHOW THE ENGINEER'S SEAL WITH THE WORDS | | "CERTIFICATE". THIS TYPE OF SEAL IS NOT ALLOWED AS OF | | JANUARY OF 2006. ENGINEER NEEDS TO CHANGE THE SEAL TO | | READ "LICENSE". ENGINEER TO CONTACT FLORIDA BOARD OF | | PROFESSIONAL ENGINEERS FOR ANY QUESTIONS REGARDING THIS | | SEAL. | | FAC 61G15-23.001. | | | | 2- IT LOOKS LIKE NEW STRUCTURAL DRAWINGS S1.01, S3.01 | | AND S3.01 SUBMITTED HAVE A COPY OF A DIGITAL SIGNATURE. | | DIGITAL SIGNATURES ARE NOT ALLOWED TO BE PRINTED. ALL | | DOCUMENTS PREPARED BY A LICENSED ENGINEER NEED TO HAVE | | THE ORIGINAL SEAL AND SIGNATURE OF THE ENGINEER OF | | RECORD AS REQUIRED BY SEC. 61G15-23.003 FAC AND CHAPTER | | 471 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR PUBLIC | | RECORDS. | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE | | ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH | | ORIGINAL SEAL AND SIGNATURE. | | | | 3- IT LOOKS LIKE REVISED ARCHITECTURAL DRAWINGS | | SUBMITTED (COVER, A1.20, AS1.10, A1.10 AND A3.20 HAVE A | | COPY OF A DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE NOT | | ALLOWED TO BE PRINTED. ALL DOCUMENTS PREPARED BY A | | LICENSED ARCHITECT NEED TO HAVE THE ORIGINAL SEAL AND | | SIGNATURE OF THE ARCHITECT OF RECORD AS REQUIRED BY | | SEC. 61G1-16.005 FAC AND CHAPTER 481 F.S. WHEN | | SUBMITTING PLANS/DOCUMENTS FOR PUBLIC RECORDS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-11-23 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2021-11-23 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-11-23 |
Time |
13:35 |
Sent To |
|
|
Notes |
2021-11-23 13:36:08 | REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2022-06-16 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-06-16 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-06-16 |
Time |
15:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-04-05 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-04-05 |
Time |
14:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-03-08 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-03-08 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-11-10 |
|
|
Cont ID |
|
Sent By |
eshneide |
Date |
2021-11-10 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2021-11-10 |
Time |
16:06 |
Sent To |
|
|
Notes |
2021-11-05 11:50:00 | SEE HISTORIC COMMENTS |
|
|