Plan Review Details - Permit 21110016
Plan Review Stops For Permit 21110016
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2021-11-01 Cont ID  
Sent By shill Date 2021-11-01 Time 12:58 Rev Time 0.00
Received By shill Date 2021-11-01 Time 12:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2022-07-13 Cont ID  
Sent By jgomez Date 2022-07-13 Time 18:39 Rev Time 0.00
Received By jgomez Date 2022-07-13 Time 18:29 Sent To  
Notes
2022-07-13 18:41:17BUILDING AUDIT OK. JG.
 NOTE: NEW AWNINGS UNDER A SEPARATE PERMIT.
 SEE NOTE ON SHEET A3.20.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2022-06-21 Cont ID  
Sent By jgomez Date 2022-06-21 Time 16:55 Rev Time 0.00
Received By jgomez Date 2022-06-21 Time 11:01 Sent To  
Notes
2022-06-21 16:55:29RESIDENTIAL (R3) ALTERATION FOURTH BUILDING AUDIT.
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21110016 (MAIN HOUSE)
  
 NOTE:
 THIS IS A LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING
 BUILDING. SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE.
  
 1-OK.
 2-OK.
  
 3- NEW STAIRWAYS:
 A)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE NEW STAIRWAYS SHOWING COMPLIANCE
 WITH SEC. R11.7 FBC-RESIDENTIAL.
  
 PREVIOUS COMMENT:
 (1)EAST SIDE STAIRS: CLARIFY TREAD DIMENSIONS. FLOOR
 PLAN SHOWS 48'-0" AND 96'-0" TREADS?.
 (NOTE: SEE SHEET A1.10. ALSO, TO AVOID MORE CONFLICTS
 AND UNNECESSARY DELAYS KEEP IN MIND THAT STAIRWAY
 LANDING CAN NOT BE LESS THAN 36" AND READ SEC. R311.7.5
 FOR RISER AND TREAD REQUIREMENTS).
  
 RESPONSE:
 REPEAT COMMENT. REVISED PLAN SHOWS 2'-0" STAIR BOTTOM
 LANDING. THE MINIMUM BOTTOM LANDING DIMENSION OF 36"
 WAS NOT PROVIDED AS REQUESTED ON PREVIOUS COMMENT TO
 AVOID MORE DELAYS. REVISE AS REQUIRED. SEC. R11.7.6
 FBC-RESIDENTIAL.
  
 4- OK.
 5- OK.
 6- OK.
  
 7- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR
 THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS
 AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE
 DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL.
  
 PREVIOUS COMMENT:
 TYPICAL AWNING DETAIL ON SHEET A3.20 DOESN'T PROVIDE
 FASTENING SPECIFICATIONS. DESIGNER OF RECORD TO PROVIDE
 THE INFORMATION TO SHOW COMPLIANCE WITH WIND DESIGN.
 SEC. R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. PROVIDE COMPLETE INFORMATION FOR AWNING
 INSTALLATION OR PROVIDE COMPLETE INFORMATION UNDER A
 SEPARATE PERMIT.
  
 8- OK.
 9- OK.
 10- OK.
 11- OK.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-05-16 Cont ID  
Sent By jgomez Date 2022-05-16 Time 11:19 Rev Time 0.00
Received By jgomez Date 2022-05-16 Time 10:16 Sent To  
Notes
2022-05-16 11:20:14RESIDENTIAL (R3) ALTERATION THIRD BUILDING AUDIT.
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21110016 (MAIN HOUSE)
  
 NOTE:
 THIS IS A LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING
 BUILDING. SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE.
  
 1-OK.
 2-OK.
  
 3- NEW STAIRWAYS:
  
 ORIGINAL COMMENT:
 A)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE NEW STAIRWAYS SHOWING COMPLIANCE
 WITH SEC. R11.7 FBC-RESIDENTIAL.
  
 RESPONSE:
 (1) REPEAT COMMENT. NOT ADDRESSED.
 EAST SIDE STAIRS: CLARIFY TREAD DIMENSIONS. FLOOR PLAN
 SHOWS 48'-0" AND 96'-0" TREADS?.
 (NOTE: SEE SHEET A1.10. ALSO, TO AVOID MORE CONFLICTS
 AND UNNECESSARY DELAYS KEEP IN MIND THAT STAIRWAY
 LANDING CAN NOT BE LESS THAN 36" AND READ SEC. R311.7.5
 FOR RISER AND TREAD REQUIREMENTS).
  
 (2)REPEAT COMMENT. NOT ADDRESSED.
 WEST SIDE STAIRS: FLOOR PLAN DOESN'T PROVIDE DIMENSIONS
 FOR LANDING AND TREADS.
 (NOTE: SEE SHEET A1.10. ALSO, TO AVOID MORE CONFLICTS
 AND UNNECESSARY DELAYS KEEP IN MIND THAT STAIRWAY
 LANDING CAN NOT BE LESS THAN 36" AND READ SEC. R311.7.5
 FOR RISER AND TREAD REQUIREMENTS).
  
 4- OK.
 5- OK.
 6- OK.
  
 ORIGINAL COMMENT:
 7- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR
 THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS
 AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE
 DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
 TYPICAL AWING DETAIL ON SHEET A3.20 DOESN'T PROVIDE
 FASTENING SPECIFICATIONS. DESIGNER OF RECORD TO PROVIDE
 THE INFORMATION TO SHOW COMPLIANCE WITH WIND DESIGN.
 SEC. R301.2.1 FBC-RESIDENTIAL.
  
 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A)OK.
  
 ORIGINAL COMMENT:
 B) INSWING FRENCH DOORS AS SHOWN ON PLANS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
 ONLY PRODUCT APPROVAL FOR OUTSWING DOOR WAS SUBMITTED.
  
 9- DESIGNER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT
 APPROVAL AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 10- OK.
 11- OK.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
 *********************************

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-04-22 Cont ID  
Sent By jgomez Date 2022-04-22 Time 16:58 Rev Time 0.00
Received By jgomez Date 2022-04-22 Time 16:31 Sent To  
Notes
2022-04-22 16:59:13RESIDENTIAL (R3) ALTERATION SECOND BUILDING AUDIT.
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21110016 (MAIN HOUSE)
  
 NOTE:
 THIS IS A LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING
 BUILDING. SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE.
  
 1-OK.
 2-OK.
  
 3- NEW STAIRWAYS:
  
 ORIGINAL COMMENT:
 A)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE NEW STAIRWAYS SHOWING COMPLIANCE
 WITH SEC. R11.7 FBC-RESIDENTIAL.
  
 RESPONSE:
 (1) EAST SIDE STAIRS: CLARIFY TREAD DIMENSIONS. FLOOR
 PLAN SHOWS 48'-0" AND 96'-0" TREADS?.
  
 (2)WEST SIDE STAIRS: FLOOR PLAN DOESN'T PROVIDE
 DIMENSIONS FOR LANDING AND TREADS.
  
 4- OK.
 5- OK.
 6- OK.
  
 ORIGINAL COMMENT:
 7- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR
 THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS
 AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE
 DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 TYPICAL AWING DETAIL ON SHEET A3.20 DOESN'T PROVIDE
 FASTENING SPECIFICATIONS. DESIGNER OF RECORD TO PROVIDE
 THE INFORMATION TO SHOW COMPLIANCE WITH WIND DESIGN.
 SEC. R301.2.1 FBC-RESIDENTIAL.
  
 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A)OK.
  
 ORIGINAL COMMENT:
 B) INSWING FRENCH DOORS AS SHOWN ON PLANS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. ONLY PRODUCT APPROVAL
 FOR OUTSWING DOOR WAS SUBMITTED.
  
 9- DESIGNER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT
 APPROVAL AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 10- OK.
 11- OK.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
 *********************************************

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-12-17 Cont ID  
Sent By jgomez Date 2021-12-17 Time 10:55 Rev Time 0.00
Received By jgomez Date 2021-12-16 Time 13:58 Sent To  
Notes
2021-12-17 10:58:03RESIDENTIAL (R3) ALTERATION BUILDING AUDIT.
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21110016
  
 NOTE:
 THIS IS A LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING
 BUILDING. SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE.
  
 1-PLANS DON'T SPECIFY CURRENT CODE AND THE DESIGN
 CRITERIA. SEC. 107.3.5.3 CITY AMENDMENTS.
 ARCHITECT TO PROVIDE ALL THE WIND DESIGN CRITERIA AS
 REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL. SPECIFY THE
 ULTIMATE AND NOMINAL WIND LOAD, BUILDING EXPOSURE,
 BUILDING MEAN ROOF HEIGHT. ALSO, SPECIFY THE COMPONENTS
 AND CLADDING DESIGN PRESSURES FOR DOORS AND WINDOWS.
  
 2- PLANS DON'T PROVIDE ANY STRUCTURAL
 DETAILS/SPECIFICATIONS. ARCHITECT NEEDS TO PROVIDE
 COMPLETE INFORMATION AS REQUIRED BY SEC. SEC. 107.3.5.3
 CITY AMENDMENTS AND SEC. R301.1 FBC-RESIDENTIAL:
  
 A) PROVIDE COMPLETE OPENING FRAMING
 DETAILS/SPECIFICATIONS FOR NEW WINDOWS AND DOORS.
 SPECIFY ALL FRAMING MEMBERS SIZES AND CONNECTORS AT
 EACH END.
  
 3- NEW STAIRWAYS:
 A)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE NEW STAIRWAYS SHOWING COMPLIANCE
 WITH SEC. R11.7 FBC-RESIDENTIAL.
  
 B)A LANDING COMPLYING WITH SEC. R311.3 FBC-RESIDENTIAL
 IS REQUIRED IN THE STAIRWAY BY THE NEW DOUBLE FRENCH
 DOORS.
  
 C) HANDRAIL IS REQUIRED ON THE NEW STAIRWAY BY THE NEW
 DOUBLE FRENCH DOORS.
 SEC. R311.7.8 FBC-RESIDENTIAL
  
 4-PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR
 THE GUARDRAIL AND HANDRAIL.
 PROVIDE COMPLETE DETAILS/SPECIFICATIONS SHOWING
 COMPLIANCE WITH TABLE R301.5, SEC. R312.1
 FBC-RESIDENTIAL.
  
 5- WINDOW ADJACENT TO THE SINGLE FRENCH DOOR NEEDS TO
 HAVE SAFETY GLAZING AS REQUIRED BY SEC. R308.4.2
 FBC-RESIDENTIAL. SHOW COMPLIANCE.
  
 6- PROVIDE COMPLETE WALL SECTION SPECIFYING WALL
 SHEATHING THICKNESS AND FASTENING, AND ALL EXTERIOR AND
 INTERIOR FINISHES. SEC. 107..3.5.3 CITY AMENDMENTS.
 ALSO, PROVIDE SPECIFICATIONS FOR THE REQUIRED TWO WATER
 RESISTIVE BARRIERS WHEN STUCCO IS APPLIED TO WOOD AS
 REQUIRED BY SEC. R703.7.3 FBC-RESIDENTIAL.
  
 7- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR
 THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS
 AS SHOWN ON PLANS. PROVIDE COMPLETE
 DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL.
  
 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A)OUTSWING ENTRY DOOR AS SHOWN ON PLANS.
  
 B) INSWING FRENCH DOORS AS SHOWN ON PLANS.
  
 9- DESIGNER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 10- MULLION: NEITHER PLANS OR PRODUCT APPROVAL
 SUBMITTED SPECIFY SIZE OF MULLION TO BE USED BETWEEN
 THE FRENCH DOOR AND THE WINDOW AS SHOWN ON PLANS.
 SPECIFY MULLION SIZE TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL.
  
 11- POOL AND POOL PAVERS ARE TO BE DONE UNDER SEPARATE
 PERMITS. SEC. 105.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2022-11-30 Cont ID  
Sent By jleahy Date 2022-07-14 Time 12:02 Rev Time 0.00
Received By jleahy Date 2022-07-14 Time 11:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-12-15 Cont ID  
Sent By jleahy Date 2021-12-15 Time 12:05 Rev Time 0.00
Received By jleahy Date 2021-12-15 Time 11:58 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 5 Status P Date 2022-07-14 Cont ID  
Sent By amhamilt Date 2022-07-14 Time 11:39 Rev Time 0.00
Received By amhamilt Date 2022-07-14 Time 11:39 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2022-06-16 Cont ID  
Sent By amhamilt Date 2022-06-16 Time 15:48 Rev Time 0.00
Received By amhamilt Date 2022-06-16 Time 15:48 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2022-04-05 Cont ID  
Sent By amhamilt Date 2022-04-05 Time 14:47 Rev Time 0.00
Received By amhamilt Date 2022-04-05 Time 14:47 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2022-03-08 Cont ID  
Sent By amhamilt Date 2022-03-08 Time 09:48 Rev Time 0.00
Received By amhamilt Date 2022-03-08 Time 09:48 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-11-10 Cont ID  
Sent By amhamilt Date 2021-11-05 Time 11:48 Rev Time 0.00
Received By amhamilt Date 2021-11-10 Time 16:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2022-07-14 Cont ID  
Sent By shill Date 2022-07-14 Time 12:02 Rev Time 0.00
Received By jleahy Date 2022-07-08 Time 09:28 Sent To  
Notes
2022-07-13 09:33:367/13 DELETED LOCKED DOCUMENTS, DELETED DOCUMENTS IN
 SIGNATURE FOLDER (EXCEPT MOST CURRENT S&S STRUCTURAL
 DOCUMENT), ROUTED BACK TO AFFIDAVIT REVIEW AND BLDG
 DIVISION AUDIT SH
  
  
2022-07-12 10:00:16PLEASE REFER TO PROJECTDOX INSTRUCTIONS.
  
 NOTHING SHOULD BE UPLOADED TO THE SIGNATURE FOLDER (SEE
 INSTRUCTIONS). ALL DOCUMENTS SHOULD BE UPLOADED TO
 DRAWINGS AND SUPPORTING DOCS.
  
 AT THIS POINT MANY DOCUMENTS HAVE BEEN LOCKED.
 COORDINATE WITH [email protected] TO DELETE ALL
 UNNECESSARY DOCUMENTS.
  
 IT APPEARS THAT A MULTIPAGE STRUCTURAL PDF WAS UPLOADED
 TO THE SIGNATURE FOLDER (ALONG WITH MANY OTHER
 DOCUMENTS). SEE PROJECTDOX INSTRUCTIONS, NOTHING SHOULD
 BE UPLOADED TO THIS FOLDER - THIS IS FOR STAFF USE
 ONLY. EACH PAGES SHOULD BE UPLOADED AS AN INDIVIDUAL
 PDF. IF THE ENGINEER REFUSES TO PROVIDE INDIVIDUALLY
 SIGNED PDFS, A SINGLE PDF CAN BE SUBMITTED AFTER ALL
 REVIEWS HAVE PASSED.
  
 THERE ARE NOW SIX DOCUMENTS IN SIGNATURE (SHOULD HAVE
 ZERO). COORDINATE WITH THE PERMIT LIBRARIANS TO HAVE
 THEM ALL DELETED. ANY REQUIRED DOCUMENTS SHOULD BE
 SUBMITTED TO THE SUPPORTING DOCS FOLDER (INCLUDING
 SIGNATURE DOCUMENTS, CLEARLY NAMED).
  
 DUE TO THE WAY FILES ARE NAMED, THEY DO NOT APPEAR IN
 ORDER. THEY APPEAR AS PAGE 1, P10, PAGE 11, P2, P13,
 P2. THIS IS WHY A DOUBLE OR TRIPLE DIGIT PREFIX IS
 REQUIRED, SEE PROJECTDOX INSTRUCTIONS. FOR INSTANCE,
 FILE NAMED 10_E1_.10R.PDF. THIS DOES NOT HAVE TO BE
 FIXED FOR THIS SUBMITTAL, BUT BE ADVISED THAT FUTURE
 SUBMITTALS MUST FOLLOW THE NAMING CONVENTION.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2022-06-21 Cont ID  
Sent By jgomez Date 2022-06-21 Time 17:12 Rev Time 0.00
Received By jgomez Date 2022-06-16 Time   Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date   Cont ID  
Sent By   Date 2022-06-17 Time   Rev Time 0.00
Received By aoliver Date 2022-06-07 Time 07:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2022-05-16 Cont ID  
Sent By jgomez Date 2022-05-16 Time 13:06 Rev Time 0.00
Received By jgomez Date 2022-05-12 Time 13:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date   Cont ID  
Sent By   Date 2022-05-11 Time   Rev Time 0.00
Received By lmarchan Date 2022-05-09 Time 15:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-04-22 Cont ID  
Sent By jgomez Date 2022-04-22 Time 17:51 Rev Time 0.00
Received By jgomez Date 2022-04-19 Time 15:27 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-04-15 Cont ID  
Sent By medwards Date 2022-04-15 Time 10:30 Rev Time 0.00
Received By medwards Date 2022-04-12 Time 16:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-04-07 Cont ID  
Sent By medwards Date 2022-04-07 Time 13:56 Rev Time 0.00
Received By medwards Date 2022-03-16 Time 08:19 Sent To  
Notes
2022-03-17 07:45:55NEW PRODUCT APPROVAL SUBMITTED, ROUTED TO Z/HIST

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-09 Cont ID  
Sent By cthroop Date 2022-03-09 Time 15:42 Rev Time 0.00
Received By cthroop Date 2022-02-23 Time 08:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-17 Cont ID  
Sent By jgomez Date 2021-12-17 Time 10:58 Rev Time 0.00
Received By jgomez Date 2021-11-22 Time 11:31 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-04 Cont ID  
Sent By ccarvaja Date 2021-11-04 Time 10:06 Rev Time 0.00
Received By ccarvaja Date 2021-11-03 Time 09:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2021-12-16 Cont ID  
Sent By medwards Date 2021-12-16 Time 11:20 Rev Time 0.00
Received By medwards Date 2021-12-16 Time 11:20 Sent To  
Notes
2021-12-16 11:21:17NO MECHANICAL WORK SHOWN ON THE PLANS. ME

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-12-17 Cont ID  
Sent By ccole Date 2021-12-15 Time 15:40 Rev Time 0.00
Received By ccole Date 2021-12-15 Time 15:16 Sent To  
Notes
2021-12-17 07:21:07NO PLUMBING WORK IN MAIN HOUSE. WORK IN GUEST HOUSE
 UNDER PERMIT 21110017.

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 11 Status P Date 2022-07-13 Cont ID  
Sent By jgomez Date 2022-07-13 Time 18:27 Rev Time 0.00
Received By jgomez Date 2022-07-13 Time 17:24 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 10 Status P Date 2022-06-21 Cont ID  
Sent By jgomez Date 2022-06-21 Time 14:00 Rev Time 0.00
Received By jgomez Date 2022-06-21 Time 14:00 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 9 Status P Date 2022-06-17 Cont ID  
Sent By rgathrig Date 2022-06-17 Time 10:25 Rev Time 0.00
Received By rgathrig Date 2022-06-17 Time 10:25 Sent To  
Notes
2022-06-17 10:26:57PRIVATE PROVIDER PAPER WORK IS OK. THIS REVIEW IS FOR
 THE NTBO AND SUPPORTING DOCUMENTS ONLY.
 PLAN RVIEW AFFIDAVIT WILL BE HANDLED BY THE PLAN
 REVIEWER
  
 RICHARD GATHRIGHT

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 8 Status P Date   Cont ID  
Sent By   Date 2022-05-13 Time   Rev Time 0.00
Received By   Date 2022-05-13 Time   Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 7 Status F Date   Cont ID  
Sent By   Date 2022-05-11 Time   Rev Time 0.00
Received By   Date 2022-05-11 Time   Sent To  
Notes
2022-05-11 17:52:08FS553.791, AN ACCURATE AFFIDAVIT IS REQUIRED PRIOR TO
 ROUTING TO BUILDING DIVISION AUDIT.
  
 TWO DOCUMENTS WERE SUBMITTED BY THE PRIVATE PROVIDER
 BUT DO NOT APPEAR ON THE AFFIDAVIT - TREMCO EXOAIR,
 DYMONIC 100. IF THESE DOCUMENTS ARE TO BE INCLUDED IN
 THE PERMIT SET, THEY NEED TO BE INCLUDED ON THE
 AFFIDAVIT. IF THEY ARE NOT REQUIRED, IT IS NOT CLEAR
 WHY THE PRIVATE PROVIDER SUBMITTED THEM. EITHER REVISE
 AFFIDAVIT TO INCLUDE OR EMAIL [email protected]
 AND REQUEST THAT THEY BE DELETED/LOCKED.
  
 CHECK ALL. AFFIDAVIT IS TO MATCH THE DOCUMENTS
 SUBMITTED.
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 6 Status P Date 2022-04-21 Cont ID  
Sent By jgomez Date 2022-04-21 Time 18:24 Rev Time 0.00
Received By jgomez Date 2022-04-21 Time 17:45 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 5 Status F Date 2022-04-15 Cont ID  
Sent By rmcdouga Date 2022-04-15 Time   Rev Time 0.00
Received By rmcdouga Date 2022-04-15 Time 12:41 Sent To  
Notes
2022-04-15 12:48:13PRIVATE PROVIDER AFFIDAVIT REVIEW
  
 1) THE AFFIDAVIT LISTS SHEET A.20. THE SUBMITTED FILE
 A0.20 HAS DRAWING A1.20 IN IT. PLEASE CORRECT.
  
2022-04-15 10:30:00PRIVATE PROVIDER AFFIDAVIT AUDIT
  
  
 1) THE AFFIDAVIT SHOWS SHEET E1.10 DATED 05/04/2021.
 THE SUBMITTED SHEET E1.10 HAS A REVISION DATE
 11/03/2021. PLEASE SHOW ON THE AFFIDAVIT THAT YOU HAVE
 REVIEWED THE MOST CURRENT VERSION OF THE DRAWING.
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 4 Status F Date   Cont ID  
Sent By   Date 2022-04-07 Time   Rev Time 0.00
Received By   Date 2022-04-07 Time   Sent To  
Notes
2022-04-07 13:56:09PRIVATE PROVIDER AFFIDAVIT AUDIT
  
 1) THE AFFIDAVIT SUBMITTED HAS A SHEET THAT IS NAMED
 A0.20, THERE IS NO SUCH SHEET IN THE DRAWING FOLDER
 THAT WAS SUBMITTED THIS CYCLE. THERE IS A SHEET A1.20
 WHICH IS WHAT PULLS UP WHEN SHEET A0.20 IS CLICKED ON.
 THERE ARE 2- A1.20 SHEETS THAT HAVE BEEN SUBMITTED EACH
 WITH A DIFFERENT DATE.
  
 2) THERE IS NO SHEET A0.00 SUBMITTED IN THE DRAWINGS
 FOLDER FOR THIS SUBMITTAL.
  
 3) PRODUCT APPROVALS 33620.1 AND 34545.1 ARE ON THE
 AFFIDAVIT BUT ARE NOT IN THE SUPPORTING DOCUMENTS
 FOLDER THAT WAS SUBMITTED THIS CYCLE.
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status F Date 2022-03-09 Cont ID  
Sent By cthroop Date 2022-03-09 Time 15:39 Rev Time 0.00
Received By cthroop Date 2022-03-09 Time 10:30 Sent To  
Notes
2022-03-09 15:42:27PP AFFIDAVIT REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DOCUMENTS LISTED ON AFFIDAVIT BUT NOT SUBMITTED FOR
 REVIEW:
 FL 34006.4 (FRENCH DOORS) AND PLAN PAGE A2.20.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status P Date 2021-11-23 Cont ID  
Sent By dbattles Date 2021-11-23 Time 11:08 Rev Time 0.00
Received By dbattles Date 2021-11-23 Time 10:59 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2021-11-10 Cont ID  
Sent By rgathrig Date 2021-11-10 Time 10:30 Rev Time 0.00
Received By rgathrig Date 2021-11-10 Time 10:30 Sent To  
Notes
2021-11-10 10:34:25PRIVATE PROVIDER REVIEW STOP PLAN REVIEW AND
 INSPECTIONS FAILED
 THERE ARE NO AFFIDAVITS SUBMITTED WITH THE NOTICE TO
 BUILDING OFFICIAL
 DOCUMENTS INCLUDED WERE NOTICE TO BUILDING OFFICIAL,
 COI, PRIVATE PROVIDER RESUME
 NO AFFIDAVITS OF CODE COMPLIANCE FOR THE PLAN REVIEW
  
 RICHARD GATHRIGHT
 ASSISTANT BUILDING OFFICIAL
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-07-13 Cont ID  
Sent By jgomez Date 2022-07-13 Time 19:04 Rev Time 0.00
Received By jgomez Date 2022-07-13 Time 19:04 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-06-21 Cont ID  
Sent By jgomez Date 2022-06-21 Time 16:58 Rev Time 0.00
Received By jgomez Date 2022-06-21 Time 16:56 Sent To  
Notes
2022-06-21 17:10:51DIGITAL SIGNATURE REVIEW:
  
 1- REVISED ARCHITECTURAL DRAWINGS SUBMITTED (COVER,
 A1.20, AS1.10, A1.10 HAVE A COPY OF A DIGITAL
 SIGNATURE. DIGITAL SIGNATURES ARE NOT ALLOWED TO BE
 PRINTED. ALL DOCUMENTS PREPARED BY A LICENSED ARCHITECT
 NEED TO HAVE THE ORIGINAL VERIFIABLE DIGITAL SIGNATURE
 OF THE ARCHITECT OF RECORD AS REQUIRED BY SEC.
 61G1-16.003 F.A.C. AND CHAPTER 481 F.S. WHEN SUBMITTING
 PLANS/DOCUMENTS FOR PUBLIC RECORDS.
  
 NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE
 ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH
 ORIGINAL SEAL AND SIGNATURE.
  
 2- REVISED STRUCTURAL DRAWINGS S1.01, S3.01 AND S3.01
 SEEM TO HAVE A COPY OF A DIGITAL SIGNATURE. .ALL
 DOCUMENTS PREPARED BY A LICENSED ENGINEER NEED TO HAVE
 THE ORIGINAL VERIFIABLE DIGITAL SIGNATURE OF THE
 ENGINEER OF RECORD AS REQUIRED BY SEC. 61G15-23.004 FAC
 AND CHAPTER 471 F.S.
  
 NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE
 ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH
 ORIGINAL SEAL AND SIGNATURE.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-05-16 Cont ID  
Sent By jgomez Date 2022-05-16 Time 13:02 Rev Time 0.00
Received By jgomez Date 2022-05-16 Time 11:20 Sent To  
Notes
2022-05-16 11:26:58DIGITAL SIGNATURE REVIEW:
  
 1- REVISED ARCHITECTURAL DRAWINGS SUBMITTED (COVER,
 A1.20, AS1.10, A1.10 AND A3.20 HAVE A COPY OF A DIGITAL
 SIGNATURE. DIGITAL SIGNATURES ARE NOT ALLOWED TO BE
 PRINTED. ALL DOCUMENTS PREPARED BY A LICENSED ARCHITECT
 NEED TO HAVE THE ORIGINAL SEAL AND SIGNATURE OF THE
 ARCHITECT OF RECORD AS REQUIRED BY SEC. 61G1-16.005 FAC
 AND CHAPTER 481 F.S. WHEN SUBMITTING PLANS/DOCUMENTS
 FOR PUBLIC RECORDS.
  
 NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE
 ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH
 ORIGINAL SEAL AND SIGNATURE.
  
  
 STRUCTURAL DRAWINGS S1.01, S3.01 AND S3.01 WITH
 ENGINEER'S ORIGINAL SEAL/SIGNATURE ARE IN SIGNATURE
 FOLDER. JG.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-04-22 Cont ID  
Sent By jgomez Date 2022-04-22 Time 17:50 Rev Time 0.00
Received By jgomez Date 2022-04-22 Time 17:50 Sent To  
Notes
2022-04-22 17:50:59DIGITAL SIGNATURE REVIEW:
  
 1- NEW STRUCTURAL DRAWINGS S1.01, S3.01 AND S3.01
 SUBMITTED SHOW THE ENGINEER'S SEAL WITH THE WORDS
 "CERTIFICATE". THIS TYPE OF SEAL IS NOT ALLOWED AS OF
 JANUARY OF 2006. ENGINEER NEEDS TO CHANGE THE SEAL TO
 READ "LICENSE". ENGINEER TO CONTACT FLORIDA BOARD OF
 PROFESSIONAL ENGINEERS FOR ANY QUESTIONS REGARDING THIS
 SEAL.
 FAC 61G15-23.001.
  
 2- IT LOOKS LIKE NEW STRUCTURAL DRAWINGS S1.01, S3.01
 AND S3.01 SUBMITTED HAVE A COPY OF A DIGITAL SIGNATURE.
 DIGITAL SIGNATURES ARE NOT ALLOWED TO BE PRINTED. ALL
 DOCUMENTS PREPARED BY A LICENSED ENGINEER NEED TO HAVE
 THE ORIGINAL SEAL AND SIGNATURE OF THE ENGINEER OF
 RECORD AS REQUIRED BY SEC. 61G15-23.003 FAC AND CHAPTER
 471 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR PUBLIC
 RECORDS.
  
 NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE
 ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH
 ORIGINAL SEAL AND SIGNATURE.
  
 3- IT LOOKS LIKE REVISED ARCHITECTURAL DRAWINGS
 SUBMITTED (COVER, A1.20, AS1.10, A1.10 AND A3.20 HAVE A
 COPY OF A DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE NOT
 ALLOWED TO BE PRINTED. ALL DOCUMENTS PREPARED BY A
 LICENSED ARCHITECT NEED TO HAVE THE ORIGINAL SEAL AND
 SIGNATURE OF THE ARCHITECT OF RECORD AS REQUIRED BY
 SEC. 61G1-16.005 FAC AND CHAPTER 481 F.S. WHEN
 SUBMITTING PLANS/DOCUMENTS FOR PUBLIC RECORDS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-11-23 Cont ID  
Sent By mpeterso Date 2021-11-23 Time 13:35 Rev Time 0.00
Received By mpeterso Date 2021-11-23 Time 13:35 Sent To  
Notes
2021-11-23 13:36:08REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED

Review Stop Z ZONING
Rev No 4 Status P Date 2022-06-16 Cont ID  
Sent By amhamilt Date 2022-06-16 Time 15:48 Rev Time 0.00
Received By amhamilt Date 2022-06-16 Time 15:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-04-05 Cont ID  
Sent By amhamilt Date 2022-04-05 Time 14:47 Rev Time 0.00
Received By amhamilt Date 2022-04-05 Time 14:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-03-08 Cont ID  
Sent By amhamilt Date 2022-03-08 Time 09:48 Rev Time 0.00
Received By amhamilt Date 2022-03-08 Time 09:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-11-10 Cont ID  
Sent By eshneide Date 2021-11-10 Time 16:06 Rev Time 0.00
Received By amhamilt Date 2021-11-10 Time 16:06 Sent To  
Notes
2021-11-05 11:50:00SEE HISTORIC COMMENTS