Plan Review Details - Permit 21101325
Plan Review Stops For Permit 21101325
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2021-12-03 Cont ID  
Sent By rmcphers Date 2021-12-03 Time 14:19 Rev Time 0.00
Received By rmcphers Date 2021-12-03 Time 14:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-02-10 Cont ID  
Sent By rmcphers Date 2022-02-10 Time 14:19 Rev Time 0.00
Received By rmcphers Date 2022-02-10 Time 14:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-01-10 Cont ID  
Sent By rmcphers Date 2022-01-10 Time 10:13 Rev Time 0.00
Received By rmcphers Date 2022-01-10 Time 10:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-12-03 Cont ID  
Sent By rmcphers Date 2021-12-03 Time 14:19 Rev Time 0.00
Received By rmcphers Date 2021-12-03 Time 14:19 Sent To  
Notes
2021-12-03 14:29:23CONDO REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A-1 SHOWS "BUILDING INFORMATION" SEPARATION
 BETWEEN TENNANTS AS 0 HOUR FIRE RATING - FBC
 708.1GENERAL.
 THE FOLLOWING WALL ASSEMBLIES SHALL COMPLY WITH THIS
 SECTION.
 1.SEPARATION WALLS AS REQUIRED BY SECTION 420.2 FOR
 GROUPS I-1, R-1, R-2 AND R-3.
 708.3FIRE-RESISTANCE RATING.
 FIRE PARTITIONS SHALL HAVE A FIRE-RESISTANCE RATING OF
 NOT LESS THAN 1 HOUR.
  
 2) FOR THE TILE FLOORING ON THE LOWER FLOOR - THE
 FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED: ( ALL
 THE TEST REPORTS NEED TO BE FOR THE SAME PRODUCT)
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 3). YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO
 VERIFY THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING
 TO PROJECTDOX ( [email protected] )
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-02-04 Cont ID  
Sent By mpeterso Date 2022-02-04 Time 15:33 Rev Time 0.00
Received By mpeterso Date 2022-02-04 Time 15:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2022-01-26 Cont ID  
Sent By jleahy Date 2022-01-26 Time 10:01 Rev Time 0.00
Received By jleahy Date 2022-01-26 Time 09:57 Sent To  
Notes
2022-01-26 10:02:14SEE 12/17/21 COMMENTS JLEAHY

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-12-17 Cont ID  
Sent By jleahy Date 2021-12-17 Time 12:20 Rev Time 0.00
Received By jleahy Date 2021-12-17 Time 12:19 Sent To  
Notes
2021-12-17 12:21:47ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 OUTLET SPACING TO MEET 210.52 FOR KITCHEN AND NEW
 PANTRY.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-02-01 Cont ID  
Sent By pleduc Date 2022-02-01 Time   Rev Time 0.00
Received By pleduc Date 2022-02-01 Time 10:35 Sent To  
Notes
2022-02-01 10:35:41FIRE PROVISO:
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION PERIODS
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-01-07 Cont ID  
Sent By pleduc Date 2022-01-07 Time   Rev Time 0.00
Received By pleduc Date 2022-01-07 Time 10:31 Sent To  
Notes
2022-01-07 10:32:33FIRE PROVISO:
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION PERIODS
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-11-12 Cont ID  
Sent By pleduc Date 2021-11-12 Time   Rev Time 0.00
Received By pleduc Date 2021-11-12 Time 14:01 Sent To  
Notes
2021-11-12 14:06:17FIRE PROVISO:
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION PERIODS
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-02-10 Cont ID  
Sent By rmcphers Date 2022-02-10 Time 14:19 Rev Time 0.00
Received By rmcphers Date 2022-01-31 Time 15:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-01-26 Cont ID  
Sent By jleahy Date 2022-01-26 Time 10:02 Rev Time 0.00
Received By jleahy Date 2022-01-06 Time 12:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-12-17 Cont ID  
Sent By jleahy Date 2021-12-17 Time 12:21 Rev Time 0.00
Received By jleahy Date 2021-11-05 Time 12:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-02-01 Cont ID  
Sent By lcrespo Date 2022-02-01 Time 14:44 Rev Time 0.00
Received By lcrespo Date 2022-02-01 Time 14:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-01-10 Cont ID  
Sent By lcrespo Date 2022-01-10 Time 06:39 Rev Time 0.00
Received By lcrespo Date 2022-01-10 Time 06:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-11-19 Cont ID  
Sent By lcrespo Date 2021-11-19 Time 10:26 Rev Time 0.00
Received By lcrespo Date 2021-11-19 Time 10:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-02-04 Cont ID  
Sent By mpeterso Date 2022-02-04 Time 15:34 Rev Time 0.00
Received By mpeterso Date 2022-02-04 Time 15:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-01-10 Cont ID  
Sent By rmcphers Date 2022-01-10 Time 10:15 Rev Time 0.00
Received By rmcphers Date 2022-01-10 Time 10:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-12-03 Cont ID  
Sent By rmcphers Date 2021-12-03 Time 14:30 Rev Time 0.00
Received By rmcphers Date 2021-12-03 Time 14:30 Sent To  
Notes
***NONE***