 |
Plan Review Details - Permit 21100610
Plan Review Stops For Permit 21100610 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-10-19 |
Time |
16:02 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-02-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-02-16 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-01-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-01-26 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-01-26 15:00:16 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21100610 | | ADD: 8851 IBIS BLVD./ GUARDHOUSE RENOVATION | | CONT: ANDERSON-MOORE CONSTRUCTION GROUP | | TEL: 561-348-4805 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: WED. JAN. 26TH/2021 | | ACTION: DENIED | | | | 1) 3RD REQUEST. SHEET A-2 THE FLOOR PLAN HAS TAKEN INTO | | CONSIDERATION FOR UPGRADING THE GUARDHOUSE FOR | | ACCESSIBILITY. | | 2020 FLORIDA ACCESSIBILITY CODE SECTION: | | DISPROPORTIONATE COST 202.4.1. PLEASE REVIEW HOW YOU | | ARE TO MEET DISPROPORTIONATE COST. EITHER THE | | CONTRACTOR OR THE DESIGNER OF RECORD ON THEIR | | LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO SPEND UP | | TO THE 20% DISPROPORTIONATE FUNDS LISTED FOR EACH | | ELEMENT WHERE THE FUNDS ARE BEING SPENT AND IN THE | | ORDER LISTED IN SECTION 202.4.1 DISPROPORTIONATE COST | | OF THE 2020 ACCESSIBILITY CODE. $265,000.00 X 0.20 = | | $53,000.00 DOLLARS. | | | | 1A) COMPLIED. | | | | 1B) 3RD REQUEST. THE FLOOR PLAN WILL NEED TO SHOW HOW | | THE BATHROOM WILL MEET COMPLIANCE WITH THE | | ACCESSIBILITY CODE CHAPTER 6 FOR SECTIONS 603-609. 2020 | | FBC-ACCESSIBILITY CODE. PLEASE PROVIDE RESTROOM | | ELEVATIONS SHOWING COMPLIANCE WITH THE ACCESSIBLE | | LAVATORY: | | 606 LAVATORIES AND SINKS> 2020 FBC-ACCESSIBILITY CODE | | SECTION 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE | | INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR | | COUNTER SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | 606.5 EXPOSED PIPES AND SURFACES. WATER SUPPLY & | | DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE | | INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST | | CONTACT. | | 1C) COMPLIED BREAK ROOM SINK AND COUNTER. | | | | 1D-E) COMPLIED. | | | | 2-4) COMPLIED. | | | | 5-8) BUILDING PROVISO/ DEFERRED SUBMITTALS | | 2020 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS, & MULLIONS | | (B) WINDOWS & MULLIONS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES, | | | | 6) DEFERRED SUBMITTALS. W. P. B. 107.3.4. PRODUCT | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY | | FLORIDA ADMINISTRATIVE CODE RULE 61G20 SHALL BE | | REVIEWED AND APPROVED IN WRITING (SHOP DRAWING STAMP OF | | APPROVAL) BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC. | | | | 7) DEFERRED SUBMITTALS. IDENTIFY GLAZING/ MULLIONS. | | PLEASE IDENTIFY IN THE PRODUCT APPROVAL BEFORE | | SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION | | TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH | | GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, | | SILL HEIGTH, TYPE OF GLAZING, MULLION SIZE, LENGTH IF | | UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED, | | ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING | | SIZE. 2020 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND | | DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED | | MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND SPACING | | SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE | | CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN | | THE TESTS. | | | | 8A) DEFERRED SUBMITTALS. 107.2.1.2 FOR ROOF ASSEMBLIES | | REQUIRED BY THE CODE, THE CONSTRUCTION DOCUMENTS SHALL | | ILLUSTRATE, DESCRIBE AND DELINEATE THE TYPE OF ROOFING | | SYSTEM, MATERIALS, VENTING, FASTENING REQUIREMENTS, | | FLASHING REQUIREMENTS AND WIND RESISTANCE RATING THAT | | ARE REQUIRED TO BE INSTALLED. PRODUCT EVALUATION AND | | INSTALLATION SHALL INDICATE COMPLIANCE WITH THE WIND | | CRITERIA REQUIRED FOR THE SPECIFIC SITE. | | | | 8B) DEFERRED SUBMITTALS. FOR CONCRETE OR CLAY TILE | | ROOFING THE 2020 FBC-BUILDING CODE SECTION 1507.3.8 | | RECOGNIZES 6TH EDITION OF THE FRSA FLORIDA HIGH WIND | | CONCRETE AND CLAY TILE MANUAL AND REQUIREMENTS WITHIN, | | INCLUDING UNDERLAYMENT REQUIREMENTS, FLASHINGS, BATTEN | | INSTALLATION, RIDGE AND HIP ATTACHMENT METHODS | | MECHANICAL, ADHESIVE SET OR MORTAR SET ATTACHMENT | | METHODS. | | | | 9) DEFERRED SUBMITTALS. FOR LOADING FOR THE TRUSSES, | | UPLIFT LOADS, PARALLEL LOADS NOR GRAVITY LOADS. | | | | 10A) 2ND REQUEST. SHEET A-7 WALL DETAIL 1 INDICATES THE | | USE OF SPRAY FOAM INSULATION W/ FIRE BARRIER ABOVE THE | | CEILING. PLEASE PROVIDE THE MANUFACTURES REPORT (ICC ER | | OR ERS REPORT) WITH LIMITATIONS. NOTE PLEASE CIRCLE | | WHICH SYSTEM WILL BE USED IN THE SPRAY FOAM | | INSTALLATION. | | | | 10B) 2ND REQUEST. PLEASE BE AWARE OF THE REQUIREMENT IN | | THE 2020 FBC-B FOR AN IGNITION BARRIER IN COMPLIANCE | | WITH SECTION 2603.4.1.6. | | | | 11) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | WORKING FROM CITY HALL. | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-12-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-12-08 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-12-08 13:51:16 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21100610 | | ADD: 8851 IBIS BLVD./ GUARDHOUSE RENOVATION | | CONT: ANDERSON-MOORE CONSTRUCTION GROUP | | TEL: 561-348-4805 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: WED. DEC. 08TH/2021 | | ACTION: DENIED | | | | 1) 2ND REQUEST. SHEET A-2 THE FLOOR PLAN DOES NOT | | APPEAR TO TAKE INTO CONSIDERATION FOR UPGRADING THE | | GUARDHOUSE FOR ACCESSIBILITY. | | 2020 FLORIDA ACCESSIBILITY CODE SECTION: | | DISPROPORTIONATE COST 202.4.1. PLEASE REVIEW HOW YOU | | ARE TO MEET DISPROPORTIONATE COST. EITHER THE | | CONTRACTOR OR THE DESIGNER OF RECORD ON THEIR | | LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO SPEND UP | | TO THE 20% DISPROPORTIONATE FUNDS LISTED FOR EACH | | ELEMENT WHERE THE FUNDS ARE BEING SPENT AND IN THE | | ORDER LISTED IN SECTION 202.4.1 DISPROPORTIONATE COST | | OF THE 2020 ACCESSIBILITY CODE. $265,000.00 X 0.20 = | | $53,000.00 DOLLARS. | | | | 202.4.2 ACCESSIBILITY FEATURES IN THE EVENT OF | | DISPROPORTIONALITY. WHEN THE COST OF THE ALTERATIONS | | NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED | | AREAS FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST | | OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE | | MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE | | ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COST. IN | | CHOOSING WHICH ELEMENTS TO PROVIDE, PRIORITY SHOULD BE | | GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE GREATEST | | ACCESS, IN THE FOLLOWING ORDER: (I) AN ACCESSIBLE | | ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE ALTERED AREA; | | (III) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR | | A SINGLE UNISEX RESTROOM; (IV) ACCESSIBLE TELEPHONES: | | (V) ACCESSIBLE DRINKING FOUNTAINS; AND (VI) WHEN | | POSSIBLE, ADDITIONAL ACCESSIBLE ELEMENTS SUCH AS | | PARKING, STORAGE, AND ALARMS. | | | | 1A) 2ND REQUEST. THE FLOOR PLAN DOES NOT INDICATE WHICH | | ENTRANCE WILL SHOW COMPLIANCE FOR AN ACCESSIBLE | | ENTRANCE2020 FBC-ACCESS. CODE CHANGES IN LEVEL 303.2 | | AND 303.3. WHERE CHANGES IN LEVEL ARE PERMITTED IN THE | | FLOOR OR GROUND SURFACES, THEY SHALL COMPLY WITH | | SECTION 303. SEE 303.1 & 303.2. | | | | 1B) 2ND REQUEST. THE FLOOR PLAN WILL NEED TO SHOW HOW | | THE BATHROOM WILL MEET COMPLIANCE WITH THE | | ACCESSIBILITY CODE CHAPTER 6 FOR SECTIONS 603-609. | | 2020 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF | | GRAB BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL | | POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE | | THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING | | SURFACE, NOT CENTERLINE. | | | | 2020 FBC-ACCESSIBILITY CODE 608.2.1 AND FIGURE 608.2.1 | | MISSING THE 36 X 48 SHOWER CLEAR FLOOR SPACE WITH ONE | | FOOT BACK OF THE SEAT WALL. | | | | 1C) 2ND REQUEST NOTE D NOTED, PART OF THE 20 % | | DISPROPORTIONATE COST. THE EMPLOYEES BREAK ROOM AND | | COMPLIANCE WITH 606 LAVATORIES AND SINKS> 2020 | | FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. LAVATORIES | | AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE | | HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES MAXIMUM | | ABOVE THE FINISH FLOOR OR GROUND. | | | | 1D) COMPLIED. | | | | 1E) 2ND REQUEST. PART OF THE 20% DISPROPORTIONATE COST. | | GUARD HOUSE NOTE D EXISTING CABINETS TO REMAIN NEW | | COUNTER TOPS. 902.1. DINING SURFACES AND WORK SURFACES | | SHALL COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 | | GENERAL. WORK AREA EXAMPLES OF WORK SURFACES INCLUDE | | WRITING SURFACES, STUDY CARRELS, STUDENT LABORATORY | | STATIONS, AND OTHER TABLES OR FIXTURES FOR PERSONAL | | GROOMING, COUPON COUNTERS, AND WHERE COVERED BY THE ADA | | SCOPING PROVISIONS, EMPLOYEE WORKSTATIONS. | | | | 2-4) COMPLIED. | | | | 5-8) BUILDING PROVISO/ DEFERRED SUBMITTALS | | 2020 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS, & MULLIONS | | (B) WINDOWS & MULLIONS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES, | | | | 6) DEFERRED SUBMITTALS. W. P. B. 107.3.4. PRODUCT | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY | | FLORIDA ADMINISTRATIVE CODE RULE 61G20 SHALL BE | | REVIEWED AND APPROVED IN WRITING (SHOP DRAWING STAMP OF | | APPROVAL) BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC. | | | | 7) DEFERRED SUBMITTALS. IDENTIFY GLAZING/ MULLIONS. | | PLEASE IDENTIFY IN THE PRODUCT APPROVAL BEFORE | | SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION | | TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH | | GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, | | SILL HEIGTH, TYPE OF GLAZING, MULLION SIZE, LENGTH IF | | UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED, | | ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING | | SIZE. 2020 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND | | DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED | | MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND SPACING | | SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE | | CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN | | THE TESTS. | | | | 8A) DEFERRED SUBMITTALS. 107.2.1.2 FOR ROOF ASSEMBLIES | | REQUIRED BY THE CODE, THE CONSTRUCTION DOCUMENTS SHALL | | ILLUSTRATE, DESCRIBE AND DELINEATE THE TYPE OF ROOFING | | SYSTEM, MATERIALS, VENTING, FASTENING REQUIREMENTS, | | FLASHING REQUIREMENTS AND WIND RESISTANCE RATING THAT | | ARE REQUIRED TO BE INSTALLED. PRODUCT EVALUATION AND | | INSTALLATION SHALL INDICATE COMPLIANCE WITH THE WIND | | CRITERIA REQUIRED FOR THE SPECIFIC SITE. | | | | 8B) DEFERRED SUBMITTALS. FOR CONCRETE OR CLAY TILE | | ROOFING THE 2020 FBC-BUILDING CODE SECTION 1507.3.8 | | RECOGNIZES 6TH EDITION OF THE FRSA FLORIDA HIGH WIND | | CONCRETE AND CLAY TILE MANUAL AND REQUIREMENTS WITHIN, | | INCLUDING UNDERLAYMENT REQUIREMENTS, FLASHINGS, BATTEN | | INSTALLATION, RIDGE AND HIP ATTACHMENT METHODS | | MECHANICAL, ADHESIVE SET OR MORTAR SET ATTACHMENT | | METHODS. | | | | 9) DEFERRED SUBMITTALS. FOR LOADING FOR THE TRUSSES, | | UPLIFT LOADS, PARALLEL LOADS NOR GRAVITY LOADS. | | | | 10A) SHEET A-7 WALL DETAIL 1 INDICATES THE USE OF SPRAY | | FOAM INSULATION W/ FIRE BARRIER ABOVE THE CEILING. | | PLEASE PROVIDE THE MANUFACTURES REPORT (ICC ER OR ERS | | REPORT) WITH LIMITATIONS. NOTE PLEASE CIRCLE WHICH | | SYSTEM WILL BE USED IN THE SPRAY FOAM INSTALLATION. | | | | 10B) PLEASE BE AWARE OF THE REQUIREMENT IN THE 2020 | | FBC-B FOR AN IGNITION BARRIER IN COMPLIANCE WITH | | SECTION 2603.4.1.6. | | | | 11) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | WORKING FROM CITY HALL. | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-10-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-10-20 |
Time |
08:00 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-10-20 08:00:48 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21100610 | | ADD: 8851 IBIS BLVD./ GUARDHOUSE RENOVATION | | CONT: ANDERSON-MOORE CONSTRUCTION GROUP | | TEL: 561-348-4805 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: WED. OCT. 20/2021 | | ACTION: DENIED | | | | 1) SHEET A-2 THE FLOOR PLAN DOES NOT APPEAR TO TAKE | | INTO CONSIDERATION FOR UPGRADING THE GUARDHOUSE FOR | | ACCESSIBILITY. | | 2020 FLORIDA ACCESSIBILITY CODE SECTION: | | DISPROPORTIONATE COST 202.4.1. PLEASE REVIEW HOW YOU | | ARE TO MEET DISPROPORTIONATE COST. EITHER THE | | CONTRACTOR OR THE DESIGNER OF RECORD ON THEIR | | LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO SPEND UP | | TO THE 20% DISPROPORTIONATE FUNDS LISTED FOR EACH | | ELEMENT WHERE THE FUNDS ARE BEING SPENT AND IN THE | | ORDER LISTED IN SECTION 202.4.1 DISPROPORTIONATE COST | | OF THE 2020 ACCESSIBILITY CODE. $265,000.00 X 0.20 = | | $53,000.00 DOLLARS. | | | | 202.4.2 ACCESSIBILITY FEATURES IN THE EVENT OF | | DISPROPORTIONALITY. WHEN THE COST OF THE ALTERATIONS | | NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED | | AREAS FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST | | OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE | | MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE | | ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COST. IN | | CHOOSING WHICH ELEMENTS TO PROVIDE, PRIORITY SHOULD BE | | GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE GREATEST | | ACCESS, IN THE FOLLOWING ORDER: (I) AN ACCESSIBLE | | ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE ALTERED AREA; | | (III) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR | | A SINGLE UNISEX RESTROOM; (IV) ACCESSIBLE TELEPHONES: | | (V) ACCESSIBLE DRINKING FOUNTAINS; AND (VI) WHEN | | POSSIBLE, ADDITIONAL ACCESSIBLE ELEMENTS SUCH AS | | PARKING, STORAGE, AND ALARMS. | | | | 1A) THE FLOOR PLAN DOES NOT INDICATE WHICH ENTRANCE | | WILL SHOW COMPLIANCE FOR AN ACCESSIBLE ENTRANCE2020 | | FBC-ACCESS. CODE CHANGES IN LEVEL 303.2 AND 303.3. | | WHERE CHANGES IN LEVEL ARE PERMITTED IN THE FLOOR OR | | GROUND SURFACES, THEY SHALL COMPLY WITH SECTION 303. | | SEE 303.1 & 303.2. | | | | 1B) THE FLOOR PLAN WILL NEED TO SHOW HOW THE BATHROOM | | WILL MEET COMPLIANCE WITH THE ACCESSIBILITY CODE | | CHAPTER 6 FOR SECTIONS 603-609. | | | | 1C) THE EMPLOYEES BREAK ROOM AND COMPLIANCE WITH 606 | | LAVATORIES AND SINKS> 2020 FBC-ACCESSIBILITY CODE | | SECTION 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE | | INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR | | COUNTER SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | | | 1D) 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE | | COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH, | | AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE | | PROVIDED, SEE EXCEPTIONS ALSO, BUT SHOW THE REQUIRED | | CLEAR FLOOR SPACE ON THE FLOOR PLAN. | | | | 1E) GUARD HOUSE NOTE D EXISTING CABINETS TO REMAIN NEW | | COUNTER TOPS. 902.1. DINING SURFACES AND WORK SURFACES | | SHALL COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 | | GENERAL. WORK AREA EXAMPLES OF WORK SURFACES INCLUDE | | WRITING SURFACES, STUDY CARRELS, STUDENT LABORATORY | | STATIONS, AND OTHER TABLES OR FIXTURES FOR PERSONAL | | GROOMING, COUPON COUNTERS, AND WHERE COVERED BY THE ADA | | SCOPING PROVISIONS, EMPLOYEE WORKSTATIONS. | | | | 2) SHEET S-3 THE LOAD SCHEDULE UNDER THE HEADING OF | | WIND HAS THE ROOF SLOPE LISTED AT 7:12. SHEETS A-3 & | | A-4 HAVE (2) ROOF SLOPES 6:12 & 12: 12 ROOF SLOPES, | | DISCREPANCY IN THE PLANS. 107.2.1.2. ADDITIONAL | | INFORMATION IS REQUIRED. | | | | 3) SHEET S-3 HAS THE ROOF PRESSURES LISTED FOR ALL ROOF | | ZONES AND OVERHANGS THE PLANS DO NOT INDICATE IF THE | | PRESSURES ARE IN VULT OR VASD, ASSUMED VASD. PLEASE | | INDICATE IF THE PRESSURES ARE ULTIMATE OR WORKING | | PRESSURES(VASD) AS IN THE PRODUCT APPROVALS. THANK YOU. | | | | 4) SHEET S-3 IS MISSING THE WINDOW AND DOOR PRESSURES | | WALL ZONES 4 & 5 IN VASD. 2020 FBC-B 1603.1.4 WIND | | DESIGN DATA. DESIGN WIND PRESSURES TO BE USED FOR | | EXTERIOR COMPONENTS AND CLADDING MATERIALS SPECIFICALLY | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. | | | | 5) 2020 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS, & MULLIONS | | (B) WINDOWS & MULLIONS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES, | | | | 6) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE | | 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP | | DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD | | PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC. | | | | 7) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY IN THE | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | IDENTIFY THE OPENING WIDTH & HEIGHT, SILL HEIGTH, TYPE | | OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR | | REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND | | ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B | | 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE | | INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S | | INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE | | PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED | | BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. | | | | 8A) 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, | | THE CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE | | AND DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS, | | VENTING, FASTENING REQUIREMENTS, FLASHING REQUIREMENTS | | AND WIND RESISTANCE RATING THAT ARE REQUIRED TO BE | | INSTALLED. PRODUCT EVALUATION AND INSTALLATION SHALL | | INDICATE COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR | | THE SPECIFIC SITE. | | | | 8B) FOR CONCRETE OR CLAY TILE ROOFING THE 2020 | | FBC-BUILDING CODE SECTION 1507.3.8 RECOGNIZES 6TH | | EDITION OF THE FRSA FLORIDA HIGH WIND CONCRETE AND CLAY | | TILE MANUAL AND REQUIREMENTS WITHIN, INCLUDING | | UNDERLAYMENT REQUIREMENTS, FLASHINGS, BATTEN | | INSTALLATION, RIDGE AND HIP ATTACHMENT METHODS | | MECHANICAL, ADHESIVE SET OR MORTAR SET ATTACHMENT | | METHODS. | | | | 9) THIS REVIEW CYCLE, NO TRUSS PACKAGE WAS SUBMITTED OR | | LAYOUT SHEET WITH LOADING FOR THE TRUSSES, UPLIFT | | LOADS, PARALLEL LOADS NOR GRAVITY LOADS. UNABLE TO | | VERIFY THE TRUSS CONNECTOR SCHEDULE WITHOUT THE TRUSS | | PACKAGE. 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. | | | | 10A) SHEET A-7 WALL DETAIL 1 INDICATES THE USE OF SPRAY | | FOAM INSULATION W/ FIRE BARRIER ABOVE THE CEILING. | | PLEASE PROVIDE THE MANUFACTURES REPORT (ICC ER OR ERS | | REPORT) WITH LIMITATIONS. NOTE PLEASE CIRCLE WHICH | | SYSTEM WILL BE USED IN THE SPRAY FOAM INSTALLATION. | | | | 10B) PLEASE BE AWARE OF THE REQUIREMENT IN THE 2020 | | FBC-B FOR AN IGNITION BARRIER IN COMPLIANCE WITH | | SECTION 2603.4.1.6. | | | | 11) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | WORKING FROM CITY HALL. | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2022-02-01 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-02-01 |
Time |
22:31 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-02-01 |
Time |
21:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2022-01-06 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-01-06 |
Time |
18:57 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-01-06 |
Time |
18:21 |
Sent To |
|
|
Notes |
2022-01-06 18:57:00 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. NOTES STATE LOAD IS BEING REDUCED. AN ACCURATE LOAD | | CALCULATION MUST BE PROVIDED REGARDLESS THAT LOAD IS | | BEING REDUCED. FBC 107.2.1 NEC 220 | | | | 2. NO INFORMATION SHOWN ON EXISTING SERVICE SIZE??? FBC | | 107.2.1 | | | | 3. NO PANEL SCHEDULES PROVIDED AS PER PREVIOUS PLAN | | REVIEW COMMENTS. FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | | | | 2021-12-08 13:57:05 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21100610 | | ADD: 8851 IBIS BLVD./ GUARDHOUSE RENOVATION | | CONT: ANDERSON-MOORE CONSTRUCTION GROUP | | TEL: 561-348-4805 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: WED. DEC. 08TH/2021 | | ACTION: DENIED | | | | 1) 2ND REQUEST. SHEET A-2 THE FLOOR PLAN DOES NOT | | APPEAR TO TAKE INTO CONSIDERATION FOR UPGRADING THE | | GUARDHOUSE FOR ACCESSIBILITY. | | 2020 FLORIDA ACCESSIBILITY CODE SECTION: | | DISPROPORTIONATE COST 202.4.1. PLEASE REVIEW HOW YOU | | ARE TO MEET DISPROPORTIONATE COST. EITHER THE | | CONTRACTOR OR THE DESIGNER OF RECORD ON THEIR | | LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO SPEND UP | | TO THE 20% DISPROPORTIONATE FUNDS LISTED FOR EACH | | ELEMENT WHERE THE FUNDS ARE BEING SPENT AND IN THE | | ORDER LISTED IN SECTION 202.4.1 DISPROPORTIONATE COST | | OF THE 2020 ACCESSIBILITY CODE. $265,000.00 X 0.20 = | | $53,000.00 DOLLARS. | | | | 202.4.2 ACCESSIBILITY FEATURES IN THE EVENT OF | | DISPROPORTIONALITY. WHEN THE COST OF THE ALTERATIONS | | NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED | | AREAS FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST | | OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE | | MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE | | ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COST. IN | | CHOOSING WHICH ELEMENTS TO PROVIDE, PRIORITY SHOULD BE | | GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE GREATEST | | ACCESS, IN THE FOLLOWING ORDER: (I) AN ACCESSIBLE | | ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE ALTERED AREA; | | (III) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR | | A SINGLE UNISEX RESTROOM; (IV) ACCESSIBLE TELEPHONES: | | (V) ACCESSIBLE DRINKING FOUNTAINS; AND (VI) WHEN | | POSSIBLE, ADDITIONAL ACCESSIBLE ELEMENTS SUCH AS | | PARKING, STORAGE, AND ALARMS. | | | | 1A) 2ND REQUEST. THE FLOOR PLAN DOES NOT INDICATE WHICH | | ENTRANCE WILL SHOW COMPLIANCE FOR AN ACCESSIBLE | | ENTRANCE2020 FBC-ACCESS. CODE CHANGES IN LEVEL 303.2 | | AND 303.3. WHERE CHANGES IN LEVEL ARE PERMITTED IN THE | | FLOOR OR GROUND SURFACES, THEY SHALL COMPLY WITH | | SECTION 303. SEE 303.1 & 303.2. | | | | 1B) 2ND REQUEST. THE FLOOR PLAN WILL NEED TO SHOW HOW | | THE BATHROOM WILL MEET COMPLIANCE WITH THE | | ACCESSIBILITY CODE CHAPTER 6 FOR SECTIONS 603-609. | | 2020 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF | | GRAB BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL | | POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE | | THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING | | SURFACE, NOT CENTERLINE. | | | | 2020 FBC-ACCESSIBILITY CODE 608.2.1 AND FIGURE 608.2.1 | | MISSING THE 36 X 48 SHOWER CLEAR FLOOR SPACE WITH ONE | | FOOT BACK OF THE SEAT WALL. | | | | 1C) 2ND REQUEST NOTE D NOTED, PART OF THE 20 % | | DISPROPORTIONATE COST. THE EMPLOYEES BREAK ROOM AND | | COMPLIANCE WITH 606 LAVATORIES AND SINKS> 2020 | | FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. LAVATORIES | | AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE | | HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES MAXIMUM | | ABOVE THE FINISH FLOOR OR GROUND. | | | | 1D) COMPLIED. | | | | 1E) 2ND REQUEST. PART OF THE 20% DISPROPORTIONATE COST. | | GUARD HOUSE NOTE D EXISTING CABINETS TO REMAIN NEW | | COUNTER TOPS. 902.1. DINING SURFACES AND WORK SURFACES | | SHALL COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 | | GENERAL. WORK AREA EXAMPLES OF WORK SURFACES INCLUDE | | WRITING SURFACES, STUDY CARRELS, STUDENT LABORATORY | | STATIONS, AND OTHER TABLES OR FIXTURES FOR PERSONAL | | GROOMING, COUPON COUNTERS, AND WHERE COVERED BY THE ADA | | SCOPING PROVISIONS, EMPLOYEE WORKSTATIONS. | | | | 2-4) COMPLIED. | | | | 5-8) BUILDING PROVISO/ DEFERRED SUBMITTALS | | 2020 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS, & MULLIONS | | (B) WINDOWS & MULLIONS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES, | | | | 6) DEFERRED SUBMITTALS. W. P. B. 107.3.4. PRODUCT | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY | | FLORIDA ADMINISTRATIVE CODE RULE 61G20 SHALL BE | | REVIEWED AND APPROVED IN WRITING (SHOP DRAWING STAMP OF | | APPROVAL) BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC. | | | | 7) DEFERRED SUBMITTALS. IDENTIFY GLAZING/ MULLIONS. | | PLEASE IDENTIFY IN THE PRODUCT APPROVAL BEFORE | | SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION | | TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH | | GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, | | SILL HEIGTH, TYPE OF GLAZING, MULLION SIZE, LENGTH IF | | UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED, | | ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING | | SIZE. 2020 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND | | DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED | | MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND SPACING | | SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE | | CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN | | THE TESTS. | | | | 8A) DEFERRED SUBMITTALS. 107.2.1.2 FOR ROOF ASSEMBLIES | | REQUIRED BY THE CODE, THE CONSTRUCTION DOCUMENTS SHALL | | ILLUSTRATE, DESCRIBE AND DELINEATE THE TYPE OF ROOFING | | SYSTEM, MATERIALS, VENTING, FASTENING REQUIREMENTS, | | FLASHING REQUIREMENTS AND WIND RESISTANCE RATING THAT | | ARE REQUIRED TO BE INSTALLED. PRODUCT EVALUATION AND | | INSTALLATION SHALL INDICATE COMPLIANCE WITH THE WIND | | CRITERIA REQUIRED FOR THE SPECIFIC SITE. | | | | 8B) DEFERRED SUBMITTALS. FOR CONCRETE OR CLAY TILE | | ROOFING THE 2020 FBC-BUILDING CODE SECTION 1507.3.8 | | RECOGNIZES 6TH EDITION OF THE FRSA FLORIDA HIGH WIND | | CONCRETE AND CLAY TILE MANUAL AND REQUIREMENTS WITHIN, | | INCLUDING UNDERLAYMENT REQUIREMENTS, FLASHINGS, BATTEN | | INSTALLATION, RIDGE AND HIP ATTACHMENT METHODS | | MECHANICAL, ADHESIVE SET OR MORTAR SET ATTACHMENT | | METHODS. | | | | 9) DEFERRED SUBMITTALS. FOR LOADING FOR THE TRUSSES, | | UPLIFT LOADS, PARALLEL LOADS NOR GRAVITY LOADS. | | | | 10A) SHEET A-7 WALL DETAIL 1 INDICATES THE USE OF SPRAY | | FOAM INSULATION W/ FIRE BARRIER ABOVE THE CEILING. | | PLEASE PROVIDE THE MANUFACTURES REPORT (ICC ER OR ERS | | REPORT) WITH LIMITATIONS. NOTE PLEASE CIRCLE WHICH | | SYSTEM WILL BE USED IN THE SPRAY FOAM INSTALLATION. | | | | 10B) PLEASE BE AWARE OF THE REQUIREMENT IN THE 2020 | | FBC-B FOR AN IGNITION BARRIER IN COMPLIANCE WITH | | SECTION 2603.4.1.6. | | | | 11) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | WORKING FROM CITY HALL. | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-11-11 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-11-11 |
Time |
22:05 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-11-11 |
Time |
21:25 |
Sent To |
|
|
Notes |
2021-11-11 22:05:24 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE PANEL SCHEDULE FBC 107.2.1 | | | | 2. PROVIDE LOAD CALCULATION NEC 220. | | | | 3. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY | | THE ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2021-12-20 |
|
|
Cont ID |
|
Sent By |
clfranci |
Date |
2021-12-20 |
Time |
|
Rev Time |
0.00 |
Received By |
clfranci |
Date |
2021-12-20 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2021-10-19 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-10-19 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-10-19 |
Time |
14:27 |
Sent To |
|
|
Notes |
2021-10-19 14:43:10 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE APPEARS TO A 12' WIDTH DIMENSION FOR THE | | ENTRANCE & EXIT. | | | | THE MINIMUM WIDTH FOR A FIRE LANE AND FD ACCESS IS 20'. | | LESSER DIMEENSION MAY BE APPROVED BY THE AHJ. | | | | 12' IS TOO NARROW AND THE RISK OF DAMAGE TO THE | | STRUCTURES & APPARATUS MAY OCCUR AND NEEDS TO BE | | INCREASED. | | | | PLEASE REIVEW AND PROVIDE GREATER DETAIL OF THE | | EXISTING ENTRANCE & EXIT AND HOW THE FD CURRENTLY | | ACCESSES THROUGH. | | | | FOR CLARIFICATION, PLEASE PROVIDE HOW THE PROPOSED IS | | EQUAL OR IMPROVES THE EXISTING SETUP. | | | | | | | | 1A) IS THIS A 24 HOUR ATTENDED SECURITY FOR 24HR FD | | ACCESS OR IS A KNOX KEY SWITCH EXISTING AND WILL BE | | PROVIDE WITH THE PROPOSED? | | | | PLEASE PROVIDE DETAILS. | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-02-16 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-02-16 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-02-11 |
Time |
12:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-02-01 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-02-01 |
Time |
22:33 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-01-21 |
Time |
06:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-01-06 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-01-06 |
Time |
18:57 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-12-07 |
Time |
12:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-11-11 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-11-11 |
Time |
22:09 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-10-15 |
Time |
07:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-12-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-12-08 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-12-08 |
Time |
10:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-10-20 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-10-20 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-10-20 |
Time |
15:31 |
Sent To |
|
|
Notes |
2021-10-20 15:32:55 | PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS FOR TIS PROJECT. FBC EC C403.2.1 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-11-01 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-11-01 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
N |
Date |
2021-12-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-12-08 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-12-08 13:55:54 | ROOFING DEFERRED SUMMITTAL: PRODUCT APPROVA REQUIRED | | FOR ROOFING PERMIT. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-10-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-10-20 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-10-20 08:02:58 | THIS REVIEW NO ROOFING PRODUCT APPROVALS WERE | | SUBMITTED. | | A) 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, | | THE CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE | | AND DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS, | | VENTING, FASTENING REQUIREMENTS, FLASHING REQUIREMENTS | | AND WIND RESISTANCE RATING THAT ARE REQUIRED TO BE | | INSTALLED. PRODUCT EVALUATION AND INSTALLATION SHALL | | INDICATE COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR | | THE SPECIFIC SITE. | | | | B) FOR CONCRETE OR CLAY TILE ROOFING THE 2020 | | FBC-BUILDING CODE SECTION 1507.3.8 RECOGNIZES 6TH | | EDITION OF THE FRSA FLORIDA HIGH WIND CONCRETE AND CLAY | | TILE MANUAL AND REQUIREMENTS WITHIN, INCLUDING | | UNDERLAYMENT REQUIREMENTS, FLASHINGS, BATTEN | | INSTALLATION, RIDGE AND HIP ATTACHMENT METHODS | | MECHANICAL, ADHESIVE SET OR MORTAR SET ATTACHMENT | | METHODS. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2022-02-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-02-16 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-02-01 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-02-01 |
Time |
22:33 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2022-01-06 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-01-06 |
Time |
18:57 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-01-06 |
Time |
18:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-11-11 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-11-11 |
Time |
22:09 |
Rev Time |
|
Received By |
fgiaquin |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-11-11 22:09:32 | SIGNATURE REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PLANS MUST BE DIGITALLY SIGNED BY PE OR AR. PLANS | | SAY THEY ARE DIGITALLY SIGNED BUT THERE IS NO SEAL OR | | 3RD PARTY VERIFICATION OF DIGITAL SIGNATURE. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2021-11-05 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-11-05 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2021-11-05 |
Time |
13:46 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |