Plan Review Stops For Permit 21100601 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2021-11-04 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-11-04 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-11-04 |
Time |
14:08 |
Sent To |
|
|
Notes |
2021-11-04 14:09:14 | ADDRESS APPROVED FOR PROJECT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-05-02 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-05-02 |
Time |
09:25 |
Sent To |
|
|
Notes |
2022-05-02 09:25:44 | PRIVATE PROVIDER BUILDING AUDIT APPROVED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-03-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-03-25 |
Time |
18:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-03-25 |
Time |
16:58 |
Sent To |
|
|
Notes |
2022-03-25 18:19:19 | 2ND PRIVATE PROVIDER AUDIT FBC-2020 RESIDENTIAL | | PERMIT-21100601 | | | | | | BUILDING AUDIT RESULTS: DENIED. | | | | 1) COMPLIED. | | | | 2) WILL COMPLY. SEPARATE PERMITS ARE REQUIRED FOR THE | | GENERATOR, DRIVEWAY, LANDSCAPING, ELEVATOR, LAWN | | SPRINKLERS, POOLS, SITE WALLS AND FENCES. | | | | 3) COMPLIED. | | | | 4) NOT COMPLIED. [THE MAXIMUM DESIGN PRESSURES IN NEW | | NOA NO. 20-1015.18 ARE +48 PSF AND -52 PSF. THIS DOES | | NOT MEET THE -61.1 PSF REQUIRED NEGATIVE PRESSURE FOR | | THE OPENING.]THE WIND PRESSURES FOR THE 9' GARAGE DOOR | | ARE SPECIFIED ON SHEET S5.00 AS +47.2 PSF, -61.1 PSF. | | THE MAXIMUM NEGATIVE PRESSURE ON THE PRODUCT APPROVAL | | FOR THE GARAGE DOORS IS -60.3 PSF, WHICH IS LESS THAN | | THE ENGINEER HAS SPECIFIED FOR THAT OPENING. FBC | | 107.3.4 | | | | 5) COMPLIED. | | | | 6) COMPLIED. | | | | 7) NOT COMPLIED. [ THE WALL SECTION STILL SHOWS SOFFIT | | VENTS AND THE INSULATION IS SHOWN AT THE CEILING AND | | NOT UNDERNEATH THE ROOF SHEATHING. ] ON SHEET A3.2, THE | | WALL SECTION SHOWS SPRAY FOAM INSULATION ON THE BOTTOM | | CORD OF THE TRUSSES AND SOFFIT VENTS FOR THE ATTIC | | SPACE. THE ENERGY EFFICIENCY FORM SPECIFIES AN UNVENTED | | ATTIC. PLEASE CORRECT. FBC 107.2.1 | | | | 8) COMPLIED. | | | | 9) COMPLIED. | | | | 10) COMPLIED. | | | | 11) NOT COMPLIED. [ I DID NOT SEE THAT THE WINDOW | | SCHEDULE WAS CHANGED TO SPECIFY FIXED RATHER THAN | | CASEMENT WINDOWS.] THE PRODUCT APPROVAL THAT WAS | | SUBMITTED FOR THE KOLBE CASEMENT WINDOWS HAS A MAXIMUM | | FRAME HEIGHT OF 72 INCHES (6 FT.) FOR THE HALF-ROUND | | WINDOWS. THE WINDOW SCHEDULE ON SHEET A-3.3 HAS SOME | | WINDOWS THAT ARE 108 INCHES (9 FT.) IN HEIGHT. SUBMIT | | PRODUCT APPROVALS FOR THE 9 FT TALL KOLBE WINDOWS. FBC | | 107.3.4 | | | | 12) NOT COMPLIED. [ I DID NOT SEE THAT THE WINDOW | | SCHEDULE WAS CHANGED TO SPECIFY FIXED RATHER THAN | | CASEMENT WINDOWS.] SUBMIT PRODUCT APPROVALS FOR THE | | SIGNATURE BRAND 9 FT TALL "CEDAR" CASEMENT WINDOWS. FBC | | 107.3.4 | | | | 13) COMPLIED. | | | | 14) COMPLIED. | | | | 15) PARTIALLY COMPLIED. [ I DID NOT SEE THE NOTE FOR | | THE WATERPROOFING IN SECTION 3.2/S-1 ON SHEET A-3.2. ] | | SPECIFY HOW THE FLOOR OF THE FRONT AND REAR BALCONIES | | WILL BE WATERPROOFED. FBC 107.2.1 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-02-25 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-02-25 |
Time |
14:50 |
Sent To |
|
|
Notes |
2022-02-25 11:00:55 | 1ST PRIVATE PROVIDER AUDIT FBC-2020 RESIDENTIAL | | PERMIT-21100601 | | | | | | BUILDING AUDIT RESULTS: DENIED. | | | | 1) IN THE SUPPORTING DOCUMENTS THERE IS A BLANK | | CONDITIONAL APPROVAL FORM FOR LANDSCAPE AND LAWN | | SPRINKLER. PLEASE COMPLETE THE FORM OR REMOVE IT. FBC | | 107.2.1 | | | | 2) SEPARATE PERMITS ARE REQUIRED FOR THE GENERATOR, | | DRIVEWAY, LANDSCAPING, ELEVATOR, LAWN SPRINKLERS, | | POOLS, SITE WALLS AND FENCES. | | | | 3) THE PRODUCT APPROVAL FOR THE TU PLUS ROOF TILE | | UNDERLAYMENT EXPIRED ON 9/13/2021. SUBMIT A CURRENT | | PRODUCT APPROVAL. FBC 107.3.4 | | | | 4) THE WIND PRESSURES FOR THE 9' GARAGE DOOR ARE | | SPECIFIED ON SHEET S5.00 AS +47.2 PSF, -61.1 PSF. THE | | MAXIMUM NEGATIVE PRESSURE ON THE PRODUCT APPROVAL FOR | | THE GARAGE DOORS IS -60.3 PSF, WHICH IS LESS THAN THE | | ENGINEER HAS SPECIFIED FOR THAT OPENING. FBC 107.3.4 | | | | 5) ON SHEET A-0.00, GENERAL NOTE #1 STATES THAT THE | | CONSTRUCTION IS TO FOLLOW THE TOWN OF PALM BEACH | | AMENDMENTS AND THIS PROJECT IS LOCATED IN THE CITY OF | | WEST PALM BEACH. PLEASE CORRECT. FBC 107.2.1 | | | | 6) THE DRAINAGE PLAN DOES NOT HAVE THE ELEVATIONS OF | | THE RIGHT OF WAY AT THE FRONT OF THE HOUSE OR THE | | ADJACENT PROPERTIES. FBC 107.2.1 | | | | 7) ON SHEET A3.2, THE WALL SECTION SHOWS SPRAY FOAM | | INSULATION ON THE BOTTOM CORD OF THE TRUSSES AND SOFFIT | | VENTS FOR THE ATTIC SPACE. THE ENERGY EFFICIENCY FORM | | SPECIFIES AN UNVENTED ATTIC. PLEASE CORRECT. FBC | | 107.2.1 | | | | 8) SHOW COMPLIANCE WITH FBC-R807.1 FOR REQUIRED ATTIC | | SPACE. | | | | 9) THE ROOF SHEATHING NAILING SCHEDULE SPECIFIES 10D | | COMMON NAILS AT 6"OC. FBC-R803.2.3.1 AND TABLE R803.2.1 | | REQUIRES THE ROOF SHEATHING TO BE NAILED 4" OC WITH | | RING SHANK NAILS MEETING THE SPECIFICATIONS IN ASTM | | F1667. FOOTNOTE A ALLOWS SHEATHING LOCATED A MINIMUM OF | | 4 FEET FROM THE PERIMETER EDGE OF THE ROOF, INCLUDING 4 | | FEET ON EACH SIDE OF RIDGES AND HIPS TO BE NAILED AT 6 | | INCHES O.C. PLEASE REVISE THE PLANS OR SUBMIT | | CALCULATIONS THAT SHOW THE NAILING THAT IS SPECIFIED ON | | THE PLANS EQUIVALENT OR BETTER. | | | | 10) SHOW COMPLIANCE WITH FBC-R 312.1 FOR THE BALCONY | | GUARDS. | | | | 11) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE | | KOLBE CASEMENT WINDOWS HAS A MAXIMUM FRAME HEIGHT OF 72 | | INCHES (6 FT.) FOR THE HALF-ROUND WINDOWS. THE WINDOW | | SCHEDULE ON SHEET A-3.3 HAS SOME WINDOWS THAT ARE 108 | | INCHES (9 FT.) IN HEIGHT. SUBMIT PRODUCT APPROVALS FOR | | THE 9 FT TALL KOLBE WINDOWS. FBC 107.3.4 | | | | 12) SUBMIT PRODUCT APPROVALS FOR THE SIGNATURE BRAND 9 | | FT TALL "CEDAR" CASEMENT WINDOWS. FBC 107.3.4 | | | | 13) SUBMIT PRODUCT APPROVALS FOR THE SIGNATURE BRAND 9 | | FT TALL X 3 FT- 7 IN "CEDAR" FRONT DOOR. FBC 107.3.4 | | | | 14) THE FIRST FLOOR PLAN APPEARS TO SHOW A FIREPLACE AT | | THE COVERED LOGGIA. THERE ARE NO OTHER DETAILS | | PROVIDED. PLEASE CLARIFY. FBC 107.2.1 | | | | 15) SPECIFY HOW THE FLOOR OF THE FRONT AND REAR | | BALCONIES WILL BE WATERPROOFED. FBC 107.2.1 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2022-05-05 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-05-05 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-05-05 |
Time |
07:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2022-03-31 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-03-31 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-03-31 |
Time |
09:50 |
Sent To |
|
|
Notes |
2022-03-31 09:53:21 | ELECTRIC REVIEW AUDIT FAILED | | 1) 2ND FLOOR REFLECTED CEILING PLAN DETAILS ALL LIGHTS | | BUT DOES NOT DETAIL ANY SWITCHES TO CONTROL THE LIGHTS. | | FBC 107.2 | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-02-22 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-02-22 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-02-22 |
Time |
09:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2022-03-28 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2022-03-28 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2022-03-28 |
Time |
08:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2022-02-22 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2022-02-22 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2022-02-22 |
Time |
12:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2022-05-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-05-05 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-04-27 |
Time |
14:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2022-04-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-04-27 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-04-26 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-04-26 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-04-19 |
Time |
15:14 |
Sent To |
|
|
Notes |
2022-04-21 10:11:05 | ROUTED TO ZONING, NEW BUILDING SECTION UPLOADED WHICH | | SHOWS BUILDING HEIGHT. | | NEEDS BEM | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2022-04-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-04-08 |
Time |
06:55 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-04-04 |
Time |
10:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2022-03-31 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-03-31 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-03-18 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2022-03-18 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-03-18 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-03-14 |
Time |
15:13 |
Sent To |
|
|
Notes |
2022-03-15 09:08:41 | NEW SITE PLAN, ELEVATIONS, UPLOADED 3/8, ROUTED TO | | ZONING | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-03-10 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-03-09 |
Time |
09:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-02-25 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-02-08 |
Time |
09:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-02-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-02-08 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-01-28 |
Time |
08:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-01-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-01-25 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-01-10 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-12-21 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2021-12-21 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2021-11-03 |
Time |
08:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2022-05-11 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-05-11 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-03-22 |
Time |
17:00 |
Sent To |
|
|
Notes |
2022-05-10 15:03:13 | RECEIPT MU-2022-021019 - $459.33 PAID | 2022-03-22 17:01:02 | 3/22/22 PER SH, SENT TO IMPACT EARLY. EMAILED IMPACT | | FOR REVIEW-AO |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-11-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-11-03 |
Time |
18:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-11-03 |
Time |
18:06 |
Sent To |
|
|
Notes |
2021-11-03 18:06:52 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION WILL OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-05-02 |
Time |
06:12 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-05-02 |
Time |
06:12 |
Sent To |
|
|
Notes |
2022-05-02 06:13:06 | MECHANICAL AUDIT ONLY. APPROVED ME |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-03-31 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-03-31 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-03-31 |
Time |
11:49 |
Sent To |
|
|
Notes |
2022-03-31 11:59:45 | PRIVATE PROVIDER MECHANICAL AUDIT APPROVED ME |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2022-02-23 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-02-23 |
Time |
06:37 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-02-23 |
Time |
06:37 |
Sent To |
|
|
Notes |
2022-02-23 06:40:39 | 1ST PRIVATE PROVIDER AUDIT FBC-2020 MECHANICAL | | PERMIT-21100601 | | | | | | MECHANICAL AUDIT RESULTS: DENIED. | | | | 1) THE DRYER VENT TERMINATIONS CANNOT HAVE AN INSECT | | SCREEN. FBC RES M1502.3 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-03-28 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2022-03-28 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2022-03-28 |
Time |
08:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2022-02-22 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2022-02-22 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2022-02-22 |
Time |
12:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
7 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-04-29 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2022-04-29 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
6 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-04-27 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2022-04-27 |
Time |
|
Sent To |
|
|
Notes |
2022-04-27 09:41:40 | PRIVATE PROVIDER AFFIDAVIT AUDIT | | | | 1) THE LATEST ENERGY SUBMITTAL IS DATED 04/18/2022. THE | | PRIVATE PROVIDER AFFIDAVIT HAS THE DATE AS 12/01/2021. |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
5 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-04-08 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2022-04-08 |
Time |
|
Sent To |
|
|
Notes |
2022-04-08 06:54:54 | PRIVATE PROVIDER AFFIDAVIT AUDIT | | | | 1) THERE ARE 2 ENERGY CALCULATIONS SUBMITTED, ONE HAS | | THE OWNER AGENT AS FRITZ VAN DER GRIFT. IT HAS THE | | FOLLOWING ISSUES: THE ENERGY CALCULATIONS DATED | | 12/01/2021 HAS AN ADDRESS OF 288 CHURCHILL RD. THE | | PERMIT APPLICATION HAS THE ADDRESS AS 228 CHURCHILL RD. | | THE PRIVATE PROVIDER AFFIDAVIT ALSO HAS AN ADDRESS OF | | 228 CHURCHILL RD. THE ENERGY CALCULATIONS WILL NEED TO | | BE CORRECTED. THE ENERGY CALCULATIONS SUBMITTED AND | | SIGNED BY BENJAMIN J JADOS ALSO HAS THE 288 CHURCHILL | | RD ADDRESS ON THE ACTUAL ENERGY CALCULATIONS ( NOT THE | | COVER SHEET) | | | | 2) THE AFFIDAVIT HAS A NOA NUMBER: 20-2103.04, THERE IS | | NO SUCH NOA SUBMITTED IN THE SUPPORTING DOCUMENTS. | | THERE IS A NOA IN THE SUPPORTING DOCUMENTS THAT IS NOT | | ON THE AFFIDAVIT: 21-0323.04 | | | | 3) THE AFFIDAVIT LISTS ISP ADHESIVE AH 160_20112407, | | THIS IS NOT IN THE SUPPORTING DOCUMENTS. THERE IS A NOA | | 21-1124.07 FOR ICP ADHESIVES AND SEALANTS, INC IN THE | | SUPPORTING DOCUMENTS THAT IS NOT ON THE AFFIDAVIT. | | | | 4) THE FOLLOWING SHEETS HAVE BEEN SUBMITTED TWICE IN | | THE DRAWINGS FOLDER. THE LATEST SHEETS ONLY SHOULD BE | | SUBMITTED. I.E. ALL UNCHANGED DRAWINGS AND ALL REVISED | | DRAWINGS. ANY DRAWINGS THAT HAVE BEEN REVISED WOULD | | MEAN THE ORIGINAL IS NO LONGER RELEVANT AND SHOULD NOT | | BE INCLUDED. A3.2, A3.3, A3.4. | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
4 |
Status |
F |
Date |
2022-03-31 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-03-31 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-03-21 |
Time |
08:44 |
Sent To |
|
|
Notes |
2022-03-31 14:06:15 | PRIVATE PROVIDER PER SEC. 553.791 F.S. | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | BU1635 BN4338 | | ASFPM CFM US-21-11935 | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | 4TH REVIEW | | | | AFFIDAVIT REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | THE FOLLOWING DOCUMENTS ARE LISTED ON THE AFFIDAVIT BUT | | ARE NOT SUBMITTED FOR REVIEW: | | | | 1.NOA 20-2103.04 | | | | THE FOLLOWING DOCUMENTS ARE SUBMITTED FOR REVIEW BUT | | NOT LISTED ON THE AFFIDAVIT: | | | | 1.NOA 17-0614.22 | | 2.NOA 20-1015.27 | | 3.FL 34545 | | | | VERIFY ALL SHEETS AND SUBMITTALS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
3 |
Status |
F |
Date |
2022-03-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-03-10 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-03-10 |
Time |
13:36 |
Sent To |
|
|
Notes |
2022-03-10 17:08:48 | 553.791, F.S. PRIVATE PROVIDER PLAN REVIEW COMPLIANCE | | AFFIDAVIT. | | PERMIT # 21100601 | | 3/10/2022 | | | | RESULTS. | | | | 1) FL #15002 WAS NOT UPLOADED INTO THE SUPPORTING | | DOCUMENTS FILE. | | | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
2 |
Status |
P |
Date |
2022-02-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-02-10 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-02-10 |
Time |
10:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2021-11-02 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2021-11-02 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2021-11-02 |
Time |
13:18 |
Sent To |
|
|
Notes |
2021-11-02 13:23:35 | QUALIFICATIONS - OK | | 553.791, F.S. PRIVATE PROVIDER PLAN REVIEW COMPLIANCE | | AFFIDAVIT. | | - PLEASE PROVIDE PLAN REVIEW COMPLIANCE AFFIDAVIT. | | UPLOAD INTO SUPPORTING DOCUMENTS IN PROJECTDOX UPON | | OTHER AGENCY APPROVAL. | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2022-03-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-03-25 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-03-25 |
Time |
17:25 |
Sent To |
|
|
Notes |
2022-03-25 17:27:24 | - NOA NO. 21-0602.14 TU PLUS | | - NOA NO. 17-0322.03 ICP AH-160 | | - NOA NO. 21-0323.04 BORAL BERMUDA CONCRETE FLAT ROOF | | TILE | | | | - NOA NO. 18-1109.01 BITUTHENE WATERPROOFING MEMBRANE | | SYSTEM = BALCONY WATERPROOFING |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-02-25 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-02-25 |
Time |
09:32 |
Sent To |
|
|
Notes |
2022-02-25 09:37:25 | - NOA NO. 17-0614.22 TU PLUS EXPIRED ON 9/13/2021. | | - NOA NO. 17-0322.03 ICP AH-160 | | - NOA NO. 21-0323.04 BORAL BERMUDA CONCRETE FLAT ROOF | | TILE |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-03-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-03-25 |
Time |
17:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-03-25 |
Time |
17:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-02-25 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-02-25 |
Time |
09:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2022-04-26 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-04-26 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-04-26 |
Time |
15:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2022-03-18 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-03-18 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-03-18 |
Time |
10:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-02-08 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2022-02-08 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2022-02-08 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-01-20 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2022-01-20 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2022-01-20 |
Time |
15:19 |
Sent To |
|
|
Notes |
2022-01-20 15:29:59 | 1/20/22- FAILED. THE HEIGHT OF THE STRUCTURE IS MEASURE | | FROM THE FINISH GRADE NOT THE FIRST FLOOR GRADE. | | PROVIDE THE HIEGHT OF THE STRUCTURE FROM THE FINISH | | GRADE. | | | | ANGELLA VANN | | 561-822-1441 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-12-21 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2021-12-21 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2021-12-21 |
Time |
14:28 |
Sent To |
|
|
Notes |
|
|