Plan Review Details - Permit 21100249
Plan Review Stops For Permit 21100249
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-11-16 Cont ID  
Sent By rmcdouga Date 2021-11-16 Time 17:24 Rev Time 0.00
Received By rmcdouga Date 2021-11-16 Time 17:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-11-08 Cont ID  
Sent By jleahy Date 2021-11-08 Time 09:43 Rev Time 0.00
Received By jleahy Date 2021-11-06 Time 16:46 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-12-12 Cont ID  
Sent By abelisle Date 2021-12-12 Time 15:40 Rev Time 0.00
Received By abelisle Date 2021-12-12 Time 15:19 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-10-20 Cont ID  
Sent By abelisle Date 2021-10-20 Time 06:09 Rev Time 0.00
Received By abelisle Date 2021-10-20 Time 06:01 Sent To  
Notes
2021-10-20 06:09:331ST REVIEW FBC-2020 PLUMBING
 PERMIT-21100249
 10/20/2021
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SEVENTH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE SEVENTH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE SEVENTH EDITION 2020
 FBC B- FLORIDA BUILDING CODE SEVENTH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE SEVENTH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SEVENTH
 EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE SEVENTH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SEVENTH
 EDITION 2020
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 1) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE
 LENGTH OF ALL CUT SECTIONS OF PIPE PER 2020 FBC FUEL
 GAS, SECS. 402.4.1, 402.4.2. OR 2020 FBC FUEL GAS RES
 SECS. G2413.4.1, G2413.4.2.
 2) LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL
 BTU LOAD ON THE SYSTEM. REFER TO THE 2020 FBC FUEL GAS
 SECS. 401.8 THROUGH 402.6.1 AND TABLES 402.4 (1)
 THROUGH 402.4 (37) OR 2020 FBC FUEL GAS RES. SEC.
 G2413.
 3) SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS
 METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER THE 2020 FBC
 FUEL GAS SEC. 402.4.1 OR 2020 FBC FUEL GAS RES. SEC.
 G2413.4.1.
 4) INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM
 ON THE PLAN PER 2020 FBC FUEL GAS SEC. 402.2 OR 2020
 FBC FUEL GAS RES. SEC. G2413.2.
 5) THE PLANS INDICATE AN EXISTING GAS METER. THE BTU
 LOAD OF THE EXISTING GAS SYSTEM MUST BE ADDED INTO THE
 TOTAL BTU LOAD ON THE SYSTEM TO ENSURE THE EXISTING
 SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, THE EXISTING
 SYSTEM MUST BE REDONE TO ENSURE A SAFE OPERATING
 SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM THAT SHOWS
 THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD OF EACH
 APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO EACH
 APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH OF
 PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE
 OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE
 EXISTING SYSTEM IS LESS THAN A 2 PSI SYSTEM AND THE
 SYSTEM PRESSURE IS INCREASED TO 2 PSI, A LINE PRESSURE
 REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES
 2020 FBC FUEL GAS SECS. 401.4, 401.8, 402.1, 402.2,
 402.3 OR 2017 FBC FUEL GAS RES. SECS.G2412.4, G2412.8,
 G2413.1, G2413.2, G2413.3.
  
 ATELYO BELISLE
 PLUMBING PLAN EXAMINER
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6695
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-13 Cont ID  
Sent By lcrespo Date 2021-12-13 Time 15:59 Rev Time 0.00
Received By lcrespo Date 2021-12-10 Time 08:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-16 Cont ID  
Sent By rmcdouga Date 2021-11-16 Time 17:24 Rev Time 0.00
Received By rmcdouga Date 2021-10-08 Time 06:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2021-12-12 Cont ID  
Sent By abelisle Date 2021-12-12 Time 15:40 Rev Time 0.00
Received By abelisle Date 2021-12-12 Time 15:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-10-20 Cont ID  
Sent By abelisle Date 2021-10-20 Time 06:01 Rev Time 0.00
Received By abelisle Date 2021-10-20 Time 05:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2021-12-13 Cont ID  
Sent By lcrespo Date 2021-12-13 Time 15:59 Rev Time 0.00
Received By lcrespo Date 2021-12-13 Time 15:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-11-16 Cont ID  
Sent By rmcdouga Date 2021-11-16 Time 17:24 Rev Time 0.00
Received By rmcdouga Date 2021-11-16 Time 17:24 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-10-28 Cont ID  
Sent By awooten Date 2021-10-28 Time   Rev Time  
Received By awooten Date 2021-10-28 Time   Sent To  
Notes
***NONE***