Plan Review Stops For Permit 21100054 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2021-10-05 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-10-05 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-10-05 |
Time |
16:49 |
Sent To |
|
|
Notes |
2021-10-05 16:49:29 | ADDRESS PREVIOUSLY AGREED UPON |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
N |
Date |
2021-11-10 |
|
|
Cont ID |
|
Sent By |
scwelter |
Date |
2021-11-10 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
scwelter |
Date |
2021-11-10 |
Time |
15:02 |
Sent To |
|
|
Notes |
2021-11-10 15:02:15 | NOT REQUIRED FOR THIS PERMIT, HOWEVER DEVELOPMENT | | SUBJECT TO PUBLIC ART REQUIREMENT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-06 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-06 |
Time |
10:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-03-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-03-22 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-22 |
Time |
14:16 |
Sent To |
|
|
Notes |
2022-03-22 14:28:34 | NEW GATEHOUSE | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE CANOPY ATTACHMENT DETAILS FBC WPB | | 107.2.1 | | | | 2) PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE | | PROVIDED PRODUCT APPROVAL THAT MEETS OR EXCEEDS THE | | REQUIRED WIND PRESSURES SHOWN ON DRAWING S100. | | | | 3) ACCESSIBLE RESTROOM - RESTROOM ENTRY DOOR CANNOT | | SWING INTO THE FIXTURE CLEAR FLOOR SPACE - UNLESS YOU | | SHOW THE CLEAR FLOOR SPACE PER THE EXCEPTION - FBC A | | 603.2.3 DOOR SWING. | | DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR | | CLEARANCE REQUIRED FOR ANY FIXTURE. EXCEPTIONS: 2.WHERE | | THE TOILET ROOM OR BATHING ROOM IS FOR INDIVIDUAL USE | | AND A CLEAR FLOOR SPACE COMPLYING WITH 305.3 IS | | PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR | | SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE CLEAR | | FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. | | | | 4) ACCESSIBLE RESTROOM - PLEASE SHOW THE DOOR | | MANEUVERING CLEARANCE (18" BESIDE THE LATCH SIDE) TO | | EXIT THE RESTROOM FBC 404.2.3 | | | | 5) CANOPY SHOP DRAWINGS MAY BE DEFERRED SUBMITTALS BY | | LISTING ITEMS TO BE DEFERRED ON THE CONSTRUCTION | | DOCUMENTS - 107.3.4.1 DEFERRED SUBMITTALS. FOR THE | | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE | | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-11-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-18 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-17 |
Time |
16:50 |
Sent To |
|
|
Notes |
2021-11-18 08:54:27 | NEW GATEHOUSE | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE CANOPY ATTACHMENT DETAILS FBC WPB | | 107.2.1 | | | | 2) SIDING IS SUBJECT TO WIND LOADS - PLEASE SHOW ALL | | ATTACHMENTS FOR THE FIBER CEMENT SIDING OR PROVIDE A | | PRODUCT APPROVAL FBC 1609.1 | | | | 3) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS AND | | ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE | | REVIEWED AND MARKED APPROVED BY THE DESIGNER OF RECORD | | FBC WPB 107.3.4 | | | | 4) DRAWING S101 SHOWS TRUSS STRAPPING AS "DETAIL 20" - | | PLEASE CLARIFY. | | | | 5) IF THE RESTROOM IS TO BE ACCESSIBLE - PLEASE SHOW | | ALL COMPONENTS ON THE FLOOR PLAN - GRAB BARS, FIXTURE | | CLEAR FLOOR SPACES, A CLEAR DOOR OPENING OF 32" (2/8 | | DOOR DOES NOT PROVIDE A CLEAR 32" CLEAR OPENING) ETC. | | PER FBC ACCESSIBILITY | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-04-07 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-04-07 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-04-07 |
Time |
08:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-11-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-11-18 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-11-18 |
Time |
15:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2022-09-21 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-09-21 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2022-09-21 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
F |
Date |
2022-05-23 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-05-23 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2022-05-23 |
Time |
|
Sent To |
|
|
Notes |
2022-05-23 12:07:09 | UNDER FORMAL ENGINEERING SUBMITTAL REVIEW. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2022-03-14 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-03-14 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2022-03-14 |
Time |
|
Sent To |
|
|
Notes |
2022-03-14 12:01:08 | UNDER REVIEW AS FORMAL ENGINEERING SUBMITTAL E21090038. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2021-10-15 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2021-10-15 |
Time |
|
Sent To |
|
|
Notes |
2021-10-15 09:12:07 | UNDER REVIEW AS FORMAL ENGINEERING SUBMITTAL E21090038. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-03-08 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-03-08 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2021-10-08 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-10-08 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-10-08 |
Time |
13:13 |
Sent To |
|
|
Notes |
2021-10-08 13:28:24 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS AN INDICATION OF A 12' WIDE EXIT ROADWAY AT | | THE GATE HOUSE. | | | | THIS 12' WIDTH IS TOO NARROW/SMALL FOR A FIRE APPARATUS | | TO USE AND COULD CAUSE DAMAGE TO THE APPARATUS AND/OR | | PROPERTY. | | | | THE MINIMUM WIDTH FOR A FIRE LANE IS 20' | | | | PLEASE REVIEW AND CORRECT OR PROVIDE FOR ALTERNATIVES | | FOR EXITING FD APPARATUS. | | | | | | 2) PROVIDE FOR THE LOCATION OF A FIRE EXTINGUISHERS AT | | THE GATE HOUSE. | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-06-23 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-05-11 |
Time |
09:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-04-07 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-04-07 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-03-07 |
Time |
08:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-01-18 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-01-18 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-10-08 |
Time |
05:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2022-09-27 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-09-27 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-06-08 |
Time |
09:34 |
Sent To |
|
|
Notes |
2022-08-19 10:21:58 | RECEIPT MU-2022-026593 - $2009.24 PAID | 2022-06-08 09:35:21 | 6/8/22 EMAILED IMPACT FOR REVIEW PER SH'SS EMAIL -AO |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-11-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-18 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-18 |
Time |
08:55 |
Sent To |
|
|
Notes |
2021-11-18 08:55:50 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-03-28 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-03-28 |
Time |
06:12 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-03-28 |
Time |
06:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-11-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-11-01 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-11-01 |
Time |
15:25 |
Sent To |
|
|
Notes |
2021-11-02 06:16:47 | 1) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. FBC EC 403.2.1 | | | | 2) PLEASE SHOW THAT THE CONDENSATE DRAIN IS TERMINATED | | TO THE OUTDOORS AND NOT INTO THE BATHROOM LAVITORY. WPB | | CODE OF ORDINANCES CHAPTER 90 SEC. 90- 126 NUMBER 5. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2022-05-21 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-05-21 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-05-21 |
Time |
11:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2022-03-22 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2022-03-09 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2022-03-08 |
Time |
15:55 |
Sent To |
|
|
Notes |
2022-03-09 08:21:08 | 03/09/22 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1) DONE. | | | | 2) DONE. | | | | 3) SHOW ON THE PLAN ALL DIMENSIONS FOR THE RESTROOM AND | | ALL CLEAR FLOOR SPACE FOR THE PLUMBING FIXTURES PER FBC | | ACC SEC. 604.8.1.6. | | | | THE CLEAR FLOOR SPACE FOR THE TURNING RADIUS HAS THE | | DOOR SWINGING INTO IT. PLEASE SHOW THAT A 30? X 40? | | WILL NOT INTERFERE WITH THE DOOR'S SWING OR HAVE THE | | DOOR SWING OUT PER THE 2020 FBC ACC. SEC. 603.2.3DOOR | | SWING. | | | | 4) THE BACKFLOWS FOR THE IRRIGATION AND DOMESTIC WATER | | SYSTEMS WILL REQUIRE A SEPARATE PERMIT. THE | | MANUFACTURER'S SPECIFICATIONS AND A SEPARATE PLUMBING | | PERMIT SHALL BE SUBMITTED BEFORE INSTALLING THESE | | DEVICES. THE DEVICES MUST BE INSTALLED BY A LICENSED | | PLUMBING CONTRACTOR.F.S.489.103. | | | | SHEET C 007 IS NOT AVAILABLE ON THE SET OF PLANS | | SUBMITTED. WOULD YOU PLEASE PROVIDE PER THE WPB | | AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS? | | | | 5) DONE. | | | | 6) WHERE IS THE LOCATION OF THE WATER SOURCE? A | | BACKFLOW PREVENTION DEVICE WILL BE REQUIRED WHEN | | HOOKING TO THE WATER SERVICE. 602.2 POTABLE WATER | | REQUIRED. 608.13 BACKFLOW PROTECTION. MEANS OF | | PROTECTION AGAINST BACKFLOW SHALL BE PROVIDED IN | | ACCORDANCE WITH SECTIONS 608.13.1 THROUGH 608.13.10. | | | | THE SHEET IN RESPONSE IS NOT AVAILABLE ON THE SET OF | | PLANS SUBMITTED. WOULD YOU PLEASE PROVIDE PER THE WPB | | AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS? | | | | 7) DONE. | | | | 8) DONE. | | | | 9) DONE. | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-11-04 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-11-04 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-11-04 |
Time |
06:07 |
Sent To |
|
|
Notes |
2021-11-04 07:16:22 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT-21100054 | | 11/4/2021 | | | | CODES IN EFFECT: | | | | FBC P- FLORIDA PLUMBING CODE SEVENTH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SEVENTH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE SEVENTH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE SEVENTH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE SEVENTH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SEVENTH | | EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE SEVENTH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SEVENTH | | EDITION 2020 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHOW THE LOCATION OF THE DRINKING FOUNTAINS ON THE | | ARCHITECTURAL FLOOR PLAN AND THE PLUMBING FLOOR PLAN. | | WPB AMEND. TO FBC SEC. 107.2.1. | | 2) A MINIMUM OF TWO DRINKING FOUNTAINS ARE REQUIRED PER | | FBCACCESS. SEC. 211.2 & FBC-PLUMBING SEC. 410.3. | | 3) SHOW ON THE PLAN ALL DIMENSIONS FOR THE RESTROOM AND | | ALL CLEAR FLOOR SPACE FOR THE PLUMBING FIXTURES PER FBC | | ACC SEC. 604.8.1.6 | | 4) THE BACKFLOWS FOR THE IRRIGATION SYSTEM AND THE | | DOMESTIC WATER SYSTEM WILL REQUIRE A SEPARATE PERMIT. | | MANUFACTURER'S SPECIFICATIONS AND A SEPARATE PLUMBING | | PERMIT SHALL BE SUBMITTED PRIOR TO THE INSTALLATION OF | | THESE DEVICES. THE DEVICES MUST BE INSTALLED BY A | | LICENSED PLUMBING CONTRACTOR.F.S.489.103. | | 5) ALL BACKFLOW DEVICES MUST BE LEAD-FREE. LEAD-FREE | | (LF) SHALL BE INCLUDED IN THE SERIAL NUMBER OR STAMPED | | ON THE BODY OF THE DEVICE. ANY DEVICE THAT HAS BEEN | | ALTERED AFTER BEING ASSEMBLED BY THE MANUFACTURER WILL | | NOT BE APPROVED. | | 6) WHERE IS THE LOCATION OF THE WATER SOURCE? WHEN | | HOOKING TO THE WATER SERVICE A BACKFLOW PREVENTION | | DEVICE WILL BE REQUIRED. 602.2 POTABLE WATER REQUIRED. | | 608.13 BACKFLOW PROTECTION. MEANS OF PROTECTION AGAINST | | BACKFLOW SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS | | 608.13.1 THROUGH 608.13.10. | | 7) THE CURRENT CODE CYCLE IS FLORIDA BUILDING CODE 2020 | | 7TH EDITION. PLEASE REMOVE AND UPDATE THE PLANS TO | | REFLECT THE CURRENT CODE CYCLE WPB AMENDMENTS TO THE | | FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | 8) SEPERATE PERMIT AND PLANS ARE REQUIRED FOR | | IRRIGATION WPB AMENDMENTS TO THE FBC SEC. 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | 9) A SERVICE SINK IS REQUIRED, PLEASE INDICATE WHERE | | ONE WILL BE LOCATED ON THE PLANS WPB AMENDMENTS TO THE | | FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | ATELYO BELISLE | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6695 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-06 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-06 |
Time |
10:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2022-03-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-03-22 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-22 |
Time |
14:41 |
Sent To |
|
|
Notes |
2022-03-22 14:42:11 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-11-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-18 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-18 |
Time |
08:55 |
Sent To |
|
|
Notes |
2021-11-18 08:56:54 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-06 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-06 |
Time |
10:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-03-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-03-22 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-22 |
Time |
14:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-11-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-18 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-18 |
Time |
09:10 |
Sent To |
|
|
Notes |
2021-11-18 09:14:02 | SIGNATURE REVIEW | | | | DRAWINGS M0-00, M0-01, M0-02, M0-03, M1-01 DO NOT SHOW | | AS DIGITALLY SIGNED IN ADOBE READER - | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | DIVISION AT THE CITY HALL. | | | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-06-22 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2022-06-22 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2022-06-21 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2022-03-18 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2022-03-18 |
Time |
12:22 |
Sent To |
|
|
Notes |
2022-03-18 12:25:51 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 03.18.2022 | | PERMIT NO.: 21100054 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. [ PARTIALLY SATISFIED ] - PLEASE CLARIFY THE | | AUTOTURN THAT IS SHOWN ON THE ELECTRICAL SITE PLAN ? IT | | IS SHOWING THE VEHICLE TURNING THROUGH THE PROPOSED | | GUARD HOUSE. THE AUTOTURN SHOULD CORRECTLY SHOW THE | | ABILITY FOR VEHICLES TO TURN AROUND BEFORE THE GATE IF | | ENTRY INTO THE DEVELOPMENT IS DENIED. | | | | 1.1 [ NEW COMMENT ] - THE NEW AUTOTURN ANALYSIS SHOWS | | VEHICLES HAVING TO MAKE A 3-POINT TURN TO TURN AROUND, | | AS WELL AS DRIVING OVER THE GRASS AREA. | | | | 2. [ SATISFIED ] - IS THE LIGHTING ALONG THE NORTH SIDE | | OF THE ROADWAY PROPOSED/NEW? LIGHTING SHOULD BE | | SHIELDED AWAY FROM ADJACENT RESIDENTIAL PROPERTIES, | | PREFERABLY NOT EXCEEDING 0.5 FOOTCANDLES WHEN MEASURED | | AT THE RESIDENTIAL PROPERTY LINE. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-01-18 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2022-01-18 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2022-01-18 |
Time |
12:01 |
Sent To |
|
|
Notes |
2022-01-18 12:04:46 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 01.18.2022 | | PERMIT NO.: 21100054 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PLEASE CLARIFY THE AUTOTURN THAT IS SHOWN ON THE | | ELECTRICAL SITE PLAN ? IT IS SHOWING THE VEHICLE | | TURNING THROUGH THE PROPOSED GUARD HOUSE. THE AUTOTURN | | SHOULD CORRECTLY SHOW THE ABILITY FOR VEHICLES TO TURN | | AROUND BEFORE THE GATE IF ENTRY INTO THE DEVELOPMENT IS | | DENIED. | | | | 2. IS THE LIGHTING ALONG THE NORTH SIDE OF THE ROADWAY | | PROPOSED/NEW? LIGHTING SHOULD BE SHIELDED AWAY FROM | | ADJACENT RESIDENTIAL PROPERTIES, PREFERABLY NOT | | EXCEEDING 0.5 FOOTCANDLES WHEN MEASURED AT THE | | RESIDENTIAL PROPERTY LINE. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|