Plan Review Stops For Permit 21091458 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-12-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-12-20 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-12-20 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-11-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-11-03 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-11-03 |
Time |
10:14 |
Sent To |
|
|
Notes |
2021-11-03 10:32:02 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10 | | FEET FROM ANY OPENINGS INTO A BUILDING. R303.5.1 INTAKE | | OPENINGS. MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE | | OPENINGS SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 | | MM) FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS | | VENTS, CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, | | PARKING LOTS AND LOADING DOCKS. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-12-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2021-12-30 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-12-30 |
Time |
16:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-11-01 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-11-01 |
Time |
20:12 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-11-01 |
Time |
19:30 |
Sent To |
|
|
Notes |
2021-11-01 20:11:57 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND | | SIGNED/SEALED BY A DESIGN PROFESSIONAL OR SIGNED BY THE | | ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-10-19 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-10-19 |
Time |
10:27 |
Sent To |
|
|
Notes |
2021-10-19 10:33:55 | 10/19/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-12-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2021-12-30 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-12-30 |
Time |
16:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-11-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-11-03 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-10-05 |
Time |
06:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2021-10-19 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-10-19 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-10-19 |
Time |
10:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-12-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-12-20 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-12-20 |
Time |
14:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-11-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-11-03 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-11-03 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-12-08 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2021-12-08 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2021-12-08 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-10-20 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-10-20 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2021-10-20 |
Time |
|
Sent To |
I |
|
Notes |
|
|