Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-11-05 Cont ID  
Sent By rmcphers Date 2021-11-05 Time 13:51 Rev Time 0.00
Received By rmcphers Date 2021-11-05 Time 13:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-10-22 Cont ID  
Sent By shill Date 2021-10-22 Time 17:04 Rev Time 0.00
Received By shill Date 2021-10-22 Time 17:04 Sent To  
Notes
2021-10-22 17:04:25****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. SEE TABLE 3A OF THE MULLION PRODUCT APPROVAL. 50" IS
 CIRCLED. IT APPEARS THAT THE OPENING WIDTH IS 72".
 PROPOSED INSTALLATION AND COMPLIANCE WITH WIND
 RESISTANCE IS NOT CLEAR, FBC B 1609. CALCLUATIONS ARE
 REQUIRED, SEE SHEETS 1 (INSTRUCTIONS) AND 24
 (EXAMPLES). EITHER PROVIDE THE CALCULATIONS,
 CORRELATING WITH CIRCLED DETAILS ON THE PRODUCT
 APPROVAL, OR PROVIDE ENOUGH INFORMATION FOR ME TO DO
 THE CALCULATIONS FOR YOU.
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-11-05 Cont ID  
Sent By rmcphers Date 2021-11-05 Time 13:51 Rev Time 0.00
Received By rmcphers Date 2021-10-27 Time 09:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-10-22 Cont ID  
Sent By shill Date 2021-10-22 Time 17:04 Rev Time 0.00
Received By shill Date 2021-10-04 Time 11:38 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-10-13 Cont ID  
Sent By mpeterso Date 2021-10-13 Time 13:07 Rev Time 0.00
Received By mpeterso Date 2021-10-13 Time 13:07 Sent To  
Notes
***NONE***