Plan Review Details - Permit 21091318
Plan Review Stops For Permit 21091318
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-11-08 Cont ID  
Sent By cthroop Date 2021-11-08 Time 07:57 Rev Time 0.00
Received By cthroop Date 2021-11-08 Time 05:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-10-10 Cont ID  
Sent By shill Date 2021-10-10 Time 15:30 Rev Time 0.00
Received By shill Date 2021-10-10 Time 15:30 Sent To  
Notes
2021-10-10 15:31:43****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC 107, SCOPE NOT CLEAR. REVISE FLOOR PLAN TO
 INDICATE LOCATION OF WORK, WHICH CABINETS WILL BE
 REPLACED, WHERE FLOORING WILL BE REPLACED.
  
 2. FBC ACCESSIBILITY, THIS PROJECT IS COVERED BY FAIR
 HOUSING. REVISE THE PLAN TO STATE THAT CABINETS WILL BE
 INSTALLED IN THE SAME LOCATION, SAME CONFIGURATION, AND
 INCLUDE PROPOSED COUNTER HEIGHTS.
  
 3. PROFLEX MSC IS PROPOSED. PROVIDE THE THREE TEST
 REPORTS REQUIRED, STC, IIC, FLAME SPREAD (SEE SPECIFICS
 BELOW). PLEASE CONTACT SUPPLIER OR MANUFACTURER; THEY
 KNOW WHAT REPORTS ARE REQUIRED.
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-10-27 Cont ID  
Sent By cwalker Date 2021-10-27 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-10-01 Cont ID  
Sent By cwalker Date 2021-10-01 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-11-08 Cont ID  
Sent By cthroop Date 2021-11-08 Time 07:58 Rev Time 0.00
Received By cthroop Date 2021-10-26 Time 12:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2021-10-20 Time   Rev Time 0.00
Received By aoliver Date 2021-09-29 Time 10:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-11-05 Cont ID  
Sent By ccole Date 2021-11-05 Time 12:00 Rev Time 0.00
Received By ccole Date 2021-11-05 Time 10:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-10-20 Cont ID  
Sent By ccole Date 2021-10-20 Time 16:09 Rev Time 0.00
Received By ccole Date 2021-10-20 Time 15:59 Sent To  
Notes
2021-10-20 16:09:571ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21091318
 10/20/21
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE PERMIT APPLICATION INDICATES REMOVAL AND
 REPLACEMENT OF CABINETS. PLEASE CLARIFY IF ANY PLUMBING
 FIXTURES SUCH AS SINKS, DISHWASHER, WATER CLOSETS,
 BATHTUB, OR SHOWER ARE ALSO TO BE REMOVED AND REPLACED
 AND PROVIDE DETAILS- SECTION 107.2.1 WPB.
  
 2) FAIR HOUSING COMPLIANCE: PLEASE NOTE REPLACEMENT OF
 THE CABINETS AND PLUMBING FIXTURES SHALL BE IN
 COMPLAINCE WITH THE FAIR HOUSING DESIGN ACT MANUAL.
 REFER TO CHAPTER 7 OF THE MANUAL AND PROVIDE DRAWINGS
 AND DETAILS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-10-10 Cont ID  
Sent By shill Date 2021-10-10 Time 15:36 Rev Time 0.00
Received By shill Date 2021-10-10 Time 15:36 Sent To  
Notes
***NONE***