Plan Review Details - Permit 21091113
Plan Review Stops For Permit 21091113
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-03-14 Cont ID  
Sent By rmcphers Date 2022-03-14 Time 12:51 Rev Time 0.00
Received By rmcphers Date 2022-03-14 Time 12:51 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-01-21 Cont ID  
Sent By rmcphers Date 2022-01-21 Time 09:15 Rev Time 0.00
Received By rmcphers Date 2022-01-21 Time 09:15 Sent To  
Notes
2022-01-21 09:15:28PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-11-10 Cont ID  
Sent By rmcphers Date 2021-11-10 Time 09:01 Rev Time 0.00
Received By rmcphers Date 2021-11-09 Time 16:25 Sent To  
Notes
2021-11-10 09:02:21PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-03-14 Cont ID  
Sent By rmcphers Date 2022-03-14 Time 12:52 Rev Time 0.00
Received By rmcphers Date 2022-03-14 Time 12:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-01-21 Cont ID  
Sent By rmcphers Date 2022-01-21 Time 09:14 Rev Time 0.00
Received By rmcphers Date 2022-01-21 Time 09:08 Sent To  
Notes
2022-01-21 09:14:19RESTROOM ALTERATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE PRODUCT APPROVAL SHOWING THAT THE
 DENSGLASS AND STUCCO EXTERIOR CLADDING SYSTEM IS TESTED
 PER FBC 1405.1 GENERAL.
 EXTERIOR WALL COVERINGS SHALL BE DESIGNED AND
 CONSTRUCTED IN ACCORDANCE WITH THE APPLICABLE
 PROVISIONS OF THIS SECTION AND TAS 202
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-11-10 Cont ID  
Sent By rmcphers Date 2021-11-10 Time 09:02 Rev Time 0.00
Received By rmcphers Date 2021-11-09 Time 16:25 Sent To  
Notes
2021-11-10 09:28:45REST ROOM ALTERATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) PLEASE SHOW BUILDING CONSTRUCTION TYPE - FBC 602.1
  
 2) PLEASE SHOW THE WIND DESIGN DATA - FBC 1603.1.4
  
 3) PLEASE SHOW THE EXTERIOR DOOR OPENING REQUIRED WIND
 DESIGN PRESSURES - FBC 1603.1.4
  
 4) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVAL - ALL PRODUCT APPROVALS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE DESIGNER OF RECORD
 - FBC WPB 107.3.4
  
 5) PLEASE SHOW THE EXTERIOR WALL MOISTURE BARRIER - FBC
 1403.2
  
 6) PLEASE SHOW THE WALL FINISH AT THE MOP SINK TO
 COMPLY WITH FBC 1210.2.2 WALLS AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR
 STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS
 SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY
 MOISTURE. (DRYWALL IS NOT CONSIDERED A HARD SURFACE)
  
 7) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET REAR
 GRAB BAR LOCATION DIMENSIONS FROM THE CENTER LINE OF
 THE TOILET - 604.5.2 REAR WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.
  
 8) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET PAPER
 HOLDER LOCATION DIMENSION FROM THE FACE OF THE TOILET
 TO COMPLY WITH FBC 604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-11-12 Cont ID  
Sent By fgiaquin Date 2021-11-12 Time 22:23 Rev Time 0.00
Received By fgiaquin Date 2021-11-12 Time 21:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-01-04 Cont ID  
Sent By pleduc Date 2022-01-04 Time   Rev Time 0.00
Received By pleduc Date 2022-01-04 Time 10:31 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-09-30 Cont ID  
Sent By pleduc Date 2021-09-30 Time   Rev Time 0.00
Received By pleduc Date 2021-09-30 Time 16:41 Sent To  
Notes
2021-09-30 16:55:13THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE IS NO CLEAR INDICATION OF THE DOOR # ON THE
 FLOOR PLAN SHEETS OF THE BATHROOM DOORS THAT EQQUAL THE
 DOOR # ON THE DOOR SCHEDULE SO THE LOCKING AND DOOR
 HARDWARE CAN BE CONFIRMED/VERIFIED FOR BATHROOM USE.
  
 PLEASE REVIEW AND PROVIDE DOOR NUMBERS ON THE FLOOR
 PLAN THAT CORRESPONDES WITH THE DOOR SCHEDULE OR BETTER
 CLARIFY WHERE I CAN LOCATE THAT INFORMATION.
  
 2) THERE IS NO INDICATION OF FIRE SPRINKLER OR FIRE
 ALARM WORK.
  
 BOTH OF THESE LIFE SAFETY SYSTEMS AND/OR
 EQUIPMNET/DEVICES MAY BE IMPACTED BY THIS PROPOSED
 WORK.
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ALL FIRE SPRINKLER & FIRE ALARM WORK. INCLUDING DEMO,
 SHALL BE DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWEDGEMENT.
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-03-24 Cont ID  
Sent By cthroop Date 2022-03-24 Time 09:18 Rev Time 0.00
Received By cthroop Date 2022-03-23 Time 12:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-14 Cont ID  
Sent By rmcphers Date 2022-03-14 Time 12:52 Rev Time 0.00
Received By rmcphers Date 2022-02-22 Time 06:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-01-21 Cont ID  
Sent By rmcphers Date 2022-01-21 Time 09:28 Rev Time 0.00
Received By rmcphers Date 2022-01-03 Time 12:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-12 Cont ID  
Sent By fgiaquin Date 2021-11-12 Time 22:23 Rev Time 0.00
Received By fgiaquin Date 2021-09-28 Time 08:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-01-13 Cont ID  
Sent By medwards Date 2022-01-13 Time 10:15 Rev Time 0.00
Received By medwards Date 2022-01-13 Time 10:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-10-20 Cont ID  
Sent By medwards Date 2021-10-20 Time 13:57 Rev Time 0.00
Received By medwards Date 2021-10-20 Time 13:57 Sent To  
Notes
2021-10-20 14:03:561) PLEASE PROVIDE THE SPECIFICATIONS FOR THE EXHAUST
 FANS ON THE MECHANICAL DRAWINGS. PLEASE SHOW THE
 REQUIRED CFM OF EXHAUST PER WATER CLOSET PER FBC M
 TABLE 403.3.1.1
 2) PLEASE SHOW THAT THE NEW BATH EXHAUST FANS
 TERMINATION LOCATION MEETS THE 3 FT. FROM OPERABLE
 OPENINGS INTO THE BUILDING PER FBC M 501.3.1-3
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-03-01 Cont ID  
Sent By jesmith Date 2022-03-01 Time 15:15 Rev Time 0.00
Received By jesmith Date 2022-03-01 Time 08:37 Sent To  
Notes
2022-03-01 15:14:5421091113 807 N FLAGLER DR
  
 PLUMBING COMMENTS: APPROVED
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 PROVISO: PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1,
 PROVIDE AS DEFERRED SUBMITTALS, ROSARIAN ACADEMY
 RENOVATIONS TO RESTROOM-LEWIS HALL EAST SPECIFICATIONS
 22 07 00 AND 22 11 16 FOR PLUMBING PIPING INSULATION
 AND PLUMBING PIPING SYSTEMS AS INDICATED ON PLAN SHEET
 P2.01/GENERAL NOTES F AND G. SUBMITTAL SHALL BE
 SUBMITTED, APPROVED AND ON SITE PRIOR TO FINAL
 INSPECTION. PROCEED AT YOUR OWN RISK.
  
 NOTE: PER ARCHITECT RESPONSE DATED 12/20/2021,
 ADDITIONAL DRINKING FOUNTAINS ARE WITHIN 300 FEET OF
 EXISTING DRINKING FOUNTAIN
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-01-11 Cont ID  
Sent By jesmith Date 2022-01-11 Time 16:38 Rev Time 0.00
Received By jesmith Date 2022-01-11 Time 16:35 Sent To  
Notes
2022-01-11 16:36:09CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21091113 807 N FLAGLER DR
  
 2ND REVIEW
  
 PLUMBING COMMENTS: DENIED
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 2A) SECOND REQUEST: THE WATER CLOSET SHALL BE
 POSITIONED WITH A WALL OR PARTITION TO THE REAR AND TO
 ONE SIDE. THE CENTERLINE OF THE WATER CLOSET SHALL BE
 16 INCHES MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE
 WALL OR PARTITION PER FBC ACC 604.2.
 TO BE CLEAR, SHOW THE CENTERLINE OF THE WATER CLOSET
 FROM THE SIDE WALL.
  
 2B) CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND
 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR
 WALL PER FBC ACC 604.3.1
 SECOND REQUEST: PROVIDE DIMENSIONS ON THE PLAN AND SHOW
 CLEARANCE IN GIRLS RR.
  
 2C) THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG
 MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE
 REAR WALL TO CENTER OF WALL ATTACHMENT (SEE FBC ACC
 FIGURE 604.5.1) AND
 SECOND REQUEST SHOW GRAB BAR EXTENDING 54 INCHES
 MINIMUM FROM THE REAR WALL PER FBC ACC 604.5.1
  
 4. MINIMUM FACILITIES; PER WPB FBC 107.2.1, PROVIDE THE
 FOLLOWING:
 NEW COMMENT: RESPONSE NOTED ON PLUMBING COMMENTS. PER
 WPB FBC 107.2.1, NOTE THE OCCUPANCY/OCCUPANCY LOAD AND
 MINIMUM FACILITY PLUMBING SCHEDULE ON THE PLANS.
  
 5. PER WPB FBC 107.2.1, REVISE FINISH WALL SCHEDULE FOR
 CUSTODIAL ROOM. REFER TO FBC PL 310.3 AND FBC 1210.2.2.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR
 STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS
 SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY
 MOISTURE. PLEASE NOTE THAT FBC 1210.2.2 STIPULATES THAT
 THE MATERIAL BE "HARD." THE INTENT OF THIS SECTION IS
 THAT THE SURROUNDING MATERIAL SHOULD NOT BE OF A TYPE
 THAT IS EASILY DAMAGED SUCH THAT THE MATERIAL COULD
 BECOME ABSORBENT AND THUS, NOT READILY CLEANABLE AND
 SANITIZED. PAINTED DRYWALL, EVEN WHERE COATED WITH
 HIGHLY DURABLE PAINTS, DOES NOT MEET THE INTENT OF
 SECTION 1210.2.2. THE TYPICAL MATERIALS USED FOR THIS
 APPLICATION ARE CERAMIC TILE, FIBERGLASS REINFORCED
 PLASTIC (FRP) PANELS, PHENOLIC PANELS, LAMINATED
 PLASTIC PANELS, PAINTED STEEL AND STAINLESS STEEL.
 NEW COMMENT: DEFER TO BUILDING PLANS EXAMINER
  
 7. P-6.01PER FBC PL 914.2, A CIRCUIT VENT CONNECTION
 SHALL BE LOCATED BETWEEN THE TWO MOST UPSTREAM (CIRCUIT
 VENTED) FIXTURE DRAINS (FLOOR DRAINS IN THIS CASE) ON
 THE BRANCH SERVICING THE BOYS AND GIRLS RESTROOMS.
 SECOND REQUEST: PROVIDE CIRCUIT VENT CONNECTION BETWEEN
 THE TWO UPSTREAM FLOOR DRAINS. TO BE CLEAR, THIS CANNOT
 BE ACCOMPLISHED BY USING A DOUBLE WYE OR COMBINATION
 WYE AND EIGHTH BEND. A WYE DOWNSTREAM FOR ONE FLOOR
 DRAIN, THEN A COMBO ON ITS BACK FOR THE VENT THEN A
 COMBO UPSTREAM FOR THE SECOND FLOOR DRAIN PROVIDES THE
 NECESSARY CONFIGURATION.
  
 17. PER WPB FBC 107.2.1, PROVIDE SPECIFICATION FOR HOT
 WATER PIPING INSULATION COMPLYING WITH FBC EC TABLE
 C403.2.10.
 NEW COMMENT: PROVIDE IN SUPPORTING DOCUMENTS DEDICATED
 "ROSARIAN ACADEMY RENOVATIONS TO RESTROOM-LEWIS HALL
 EAST SPECIFICATION 22 07 00 PLUMBING INSULATION"
 NEW COMMENT: PROVIDE NOTE "PROVIDE INSULATION OF
 PLUMBING PIPING SYSTEMS IN ACCORDANCE WITH ROSARIAN
 ACADEMY RENOVATIONS TO RESTROOM-LEWIS HALL EAST
 SPECIFICATION 22 07 00"
  
  
 19. PER WPB FBC 107.2.1, PROVIDE MATERIAL SPECIFICATION
 FOR PLUMBING PIPING SYSTEMS. SUPPORTING DOCUMENT SGM
 MEP IS INCOMPLETE.
 NEW COMMENT: PROVIDE IN SUPPORTING DOCUMENTS DEDICATED
 "ROSARIAN ACADEMY RENOVATIONS TO RESTROOM-LEWIS HALL
 EAST SPECIFICATION 22 11 16 DOMESTIC WATER PIPING"
 NEW COMMENT: PROVIDE NOTE "PROVIDE PIPING SYSTEMS IN
 ACCORDANCE WITH ROSARIAN ACADEMY RENOVATIONS TO
 RESTROOM-LEWIS HALL EAST SPECIFICATION 22 11 16
 DOMESTIC WATER PIPING"
  
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-11-04 Cont ID  
Sent By ccole Date 2021-11-04 Time 13:59 Rev Time 0.00
Received By jesmith Date 2022-02-01 Time 13:27 Sent To  
Notes
2021-11-04 14:00:00CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21091113 807 N FLAGLER DR
  
 1ST REVIEW
  
 PLUMBING COMMENTS: DENIED
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1.PER FBC ACC 202.4.1 AND 202.4.2, PROVIDE
 CONSIDERATION FOR UPGRADING DRINKING FOUNTAIN TO A
 BI-LEVEL TO COMPLY WITH FBC ACC 602.4, 602.7 AND 307.2.
 202.4.1DISPROPORTIONATE COST.
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
 202.4.2ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
 WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH
 OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE
 ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE
 ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE
 FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST
 ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX
 RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE
 DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
 202.4.3SERIES OF SMALLER ALTERATIONS.
 THE OBLIGATION TO PROVIDE AN ACCESSIBLE PATH OF TRAVEL
 MAY NOT BE EVADED BY PERFORMING A SERIES OF SMALL
 ALTERATIONS TO THE AREA SERVED BY A SINGLE PATH OF
 TRAVEL IF THOSE ALTERATIONS COULD HAVE BEEN PERFORMED
 AS A SINGLE UNDERTAKING.
 202.4.3.1
 IF AN AREA CONTAINING A PRIMARY FUNCTION HAS BEEN
 ALTERED WITHOUT PROVIDING AN ACCESSIBLE PATH OF TRAVEL
 TO THAT AREA, AND SUBSEQUENT ALTERATIONS OF THAT AREA,
 OR A DIFFERENT AREA ON THE SAME PATH OF TRAVEL, ARE
 UNDERTAKEN WITHIN THREE YEARS OF THE ORIGINAL
 ALTERATION, THE TOTAL COST OF ALTERATIONS TO THE
 PRIMARY FUNCTION AREAS ON THAT PATH OF TRAVEL DURING
 THE PRECEDING THREE YEAR PERIOD SHALL BE CONSIDERED IN
 DETERMINING WHETHER THE COST OF MAKING THAT PATH OF
 TRAVEL ACCESSIBLE IS DISPROPORTIONATE.
  
 2.PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC
 CHAPTERS 2, 3 AND 6, PLAN AND ELEVATION DETAILS FOR NEW
 TOILET ROOM(S) SHALL CLEARLY INDICATE THE FOLLOWING:
 ?A) THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUM TO 18
 INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION PER FBC
 ACC 604.2
 ?B) CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND
 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR
 WALL PER FBC ACC 604.3.1
 ?C) THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG
 MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE
 REAR WALL TO CENTER OF WALL ATTACHMENT (SEE FBC ACC
 FIGURE 604.5.1) AND EXTENDING 54 INCHES MINIMUM FROM
 THE REAR WALL PER FBC ACC 604.5.1
 ?D) THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES
 MINIMUM ON THE OTHER SIDE PER FBC ACC 604.5.2
 ?E) FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC.
 HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH 309.
 FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE
 WATER CLOSET PER FBC ACC 604.6
 ?F) TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15
 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS PER FBC
 ACC 604.8.
 ?G) PER FBC ACC 609.4, GRAB BARS SHALL BE INSTALLED IN
 A HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP (NOT
 THE CENTER) OF THE GRIPPING SURFACE,
 ?H) SHOW TOE AND KNEE CLEARANCE FOR LAVATORY AS
 REQUIRED BY FBC ACC 306.2 AND 306.3
 ?I) PROVIDE NOTE ?PER FBC 606.5 EXPOSED PIPES AND
 SURFACES. WATER SUPPLY & DRAINPIPES UNDER LAVATORIES
 AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO
 PROTECT AGAINST CONTACT.
 ?J) MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS
 SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE
 REFLECTING SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE
 THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE
 LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
 BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES (890
 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC
 ACC 603.3.
  
 3. PER WPB FBC 107.2.1, PROVIDE FINISH DIMENSIONS FOR
 THE TOILET ROOMS
  
 4. MINIMUM FACILITIES; PER WPB FBC 107.2.1, PROVIDE THE
 FOLLOWING:
 ?A) THE OCCUPANCY AND OCCUPANCY LOAD FOR THE BUILDING
 ?B) A MINIMUM FACILITY PLUMBING SCHEDULE SHOWING
 COMPLIANCE WITH FBC PL TABLE 403.1; INDICATE MINIMUM
 FIXTURES REQUIRED FOR THE STATED OCCUPANCY AND OCCUPANT
 LOAD AND THE ACTUAL SUPPLIED AFTER COMPLETION OF NEW
 WORK.
  
 5. PER WPB FBC 107.2.1, REVISE FINISH WALL SCHEDULE FOR
 CUSTODIAL ROOM. REFER TO FBC PL 310.3 AND FBC 1210.2.2.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR
 STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS
 SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY
 MOISTURE. PLEASE NOTE THAT FBC 1210.2.2 STIPULATES THAT
 THE MATERIAL BE "HARD." THE INTENT OF THIS SECTION IS
 THAT THE SURROUNDING MATERIAL SHOULD NOT BE OF A TYPE
 THAT IS EASILY DAMAGED SUCH THAT THE MATERIAL COULD
 BECOME ABSORBENT AND THUS, NOT READILY CLEANABLE AND
 SANITIZED. PAINTED DRYWALL, EVEN WHERE COATED WITH
 HIGHLY DURABLE PAINTS, DOES NOT MEET THE INTENT OF
 SECTION 1210.2.2. THE TYPICAL MATERIALS USED FOR THIS
 APPLICATION ARE CERAMIC TILE, FIBERGLASS REINFORCED
 PLASTIC (FRP) PANELS, PHENOLIC PANELS, LAMINATED
 PLASTIC PANELS, PAINTED STEEL AND STAINLESS STEEL.
  
 6. P-7.01: PLUMBING FIXTURE SCHEDULE; SEE THE FOLLOWING
 ?A) REGARDING PLUMBING FIXTURE NOTE E; FLORIDA BUILDING
 CODE 423.4.4 DOES NOT EXIST. SECTION 423 REFERS TO
 CHILDRENS PLAY STRUCTURES, NOT PLUMBING FIXTURES. PER
 WPB FBC 107.2.1, CLARIFY.
 ?B) L-2 ADD TO REMARK ?PER FLORIDA ACCESSIBILITY CODE
 606.4, HAND-OPERATED METERING FAUCETS SHALL REMAIN OPEN
 FOR 10 SECONDS MINIMUM?
  
 7. PER FBC PL 914.2, A CIRCUIT VENT CONNECTION SHALL BE
 LOCATED BETWEEN THE TWO MOST UPSTREAM (CIRCUIT VENTED)
 FIXTURE DRAINS (FLOOR DRAINS IN THIS CASE) ON THE
 BRANCH SERVICING THE BOYS AND GIRLS RESTROOMS.
  
 8. PER FBC PL 914.4, 914.4.1, PROVIDE A RELIEF VENT
 DOWNSTREAM (DOWNSTREAM FROM WC-1 IN THE GIRLS RESTROOM)
 OF THE CIRCUIT VENTED FIXTURES.
  
 9. PER WPB FBC 107.2.1, SHOW TRAPS FOR FLOOR DRAINS ON
 THE SANITARY RISER TO SHOW COMPLIANCE WITH FBC PL
 1002.1,
  
 10. P-701, PRIMARY AND SECONDARY TRAP SEAL PROTECTION
 DEVICE SCHEDULES; SECONDARY PROTECTION IS TO BE APPLIED
 TO ALL FLOOR DRAINS EXISTING AND NEW AND IN ADDITION,
 PRIMARY PROTECTION IS REQUIRED ON NEW FLOOR DRAINS. PER
 WPB FBC 107.2.1, INDICATE ON P-801/DETAIL 2 AND 5, THE
 SECONDARY DEVICE.
  
 11. P-701, PRIMARY TRAP SEAL PROTECTION DEVICE SCHEDULE
 AND P-801/DETAIL 5 PROVIDE CONFLICTING DEVICES TO BE
 USED. PER WPB FBC 107.2.1, CLARIFY.
  
 12. P-601 WATER RISER SHOWS ONE (1) WH-1 WALL HYDRANT
 ON THE COLD WATER DISTRIBUTION. P-801/DETAIL 3
 INDICATES HOT WATER. PER WPB FBC 107.2.1, CLARIFY.
  
 13. THE WATER DISTRIBUTION SEEMS TO BE UNDER SIZED FOR
 ACCOMMODATION OF FLUSHOMETER VALVES. PER WPB FBC
 107.2.1, PROVIDE CALCULATIONS FOR SIZING OF THE WATER
 DISTRIBUTION AND SIZE ACCORDINGLY. PLEASE NOTE THAT
 CALCULATIONS IN ACCORDANCE WITH FBC PL APPENDIX E USING
 TABLE 103.3(3) TABLE FOR ESTIMATING DEMAND-SUPPLY
 SYSTEMS PREDOMINANTLY FOR FLUSHOMETER VALVES, TABLE
 E103.3(2) LOAD VALUES ASSIGNED TO FIXTURES AND FIGURE
 E103.3(3) FRICTION LOSS IN SMOOTH PIPE (TYPE L, ASTM
 B88 COPPER TUBING) AND TABLE E103.3(6) ARE AN
 ACCEPTABLE METHOD (SEE FBC PL 604.1).
  
 14. PER WPB FBC 107.2.1, SIZE ALL SEGMENTS OF THE WATER
 DISTRIBUTION ON P-601 WATER RISER.
  
 15. P-801/DETAIL 4: PER WPB FBC 107.2.1, PROVIDE ON
 PIPE HANGER DETAIL A NOTE STATING, "HORIZONTAL PIPE
 SHALL BE SUPPORTED IN ACCORDANCE WITH FBC PL TABLE
 308.5." AND REMOVE REFERENCES TO UL/FM AND FIRE
 SPRINKLER PIPE. PROVIDE HANGERS COMPATIBLE WITH THE
 PLUMBING SYSTEMS.
  
 16. PER WPB FBC 107.2.1, NOTE THE DEVELOPED LENGTH OF
 THE HOT WATER FROM THE SOURCE OF THE HOT WATER TO MS-1.
 PLEASE SEE FBC PL 607.2.
 THE DEVELOPED LENGTH OF HOT OR TEMPERED WATER PIPING,
 FROM THE SOURCE OF HOT WATER TO THE FIXTURES THAT
 REQUIRE HOT OR TEMPERED WATER, SHALL NOT EXCEED 50 FEET
 (15 240 MM). RECIRCULATING SYSTEM PIPING AND
 HEAT-TRACED PIPING SHALL BE CONSIDERED TO BE SOURCES OF
 HOT OR TEMPERED WATER.?
  
 17. PER WPB FBC 107.2.1, PROVIDE SPECIFICATION FOR HOT
 WATER PIPING INSULATION COMPLYING WITH FBC EC TABLE
 C403.2.10.
  
 18. PER WPB FBC 107.2.1, SHOW ON P-601 WATER RISER
 DIAGRAM, LOCATIONS AND PDI SIZES OF WATER HAMMER
 ARRESTORS.
  
 19. PER WPB FBC 107.2.1, PROVIDE MATERIAL SPECIFICATION
 FOR PLUMBING PIPING SYSTEMS. SUPPORTING DOCUMENT SGM
 MEP IS INCOMPLETE.
  
 20. PLEASE NOTE, ALL COMPONENTS IN THE DOMESTIC WATER
 SYSTEM SHALL BE LEAD FREE IN ACCORDANCE WITH FBC PL
 605.2 AND 605.2.1. PER WPB FBC 107.2.1, PROVIDE NOTE ON
 PLANS STATING THE SAME.
  
 21. THE PLUMBING RISER DIAGRAMS INDICATE THE PROJECT IS
 ON AN ELEVATED FLOOR. PER WPB FBC 107.2.1, STATE THE
 FLOOR LEVEL ON THE PLANS.
  
 22. PER WPB FBC 107.2.1, INDICATE ANY FIRE RATED
 STRUCTURE THE PIPING WILL BE PASSING THROUGH (FLOOR OR
 WALL) AND PROVIDE FIRE RATED ASSEMBLIES COMPLYING WITH
 FBC CHAPTER 7.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-03-24 Cont ID  
Sent By cthroop Date 2022-03-24 Time 09:18 Rev Time 0.00
Received By cthroop Date 2022-03-24 Time 09:04 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-03-14 Cont ID  
Sent By rmcphers Date 2022-03-14 Time 12:51 Rev Time 0.00
Received By rmcphers Date 2022-03-14 Time 12:51 Sent To  
Notes
2022-03-14 12:51:51SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWING S-1 DOES NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-01-21 Cont ID  
Sent By rmcphers Date 2022-01-21 Time 09:21 Rev Time 0.00
Received By rmcphers Date 2022-01-21 Time 09:21 Sent To  
Notes
2022-01-21 09:27:12SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWING S-1 DOES NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-11-10 Cont ID  
Sent By rmcphers Date 2021-11-10 Time 09:49 Rev Time 0.00
Received By rmcphers Date 2021-11-10 Time 09:49 Sent To  
Notes
***NONE***