Plan Review Details - Permit 21090861
Plan Review Stops For Permit 21090861
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2022-02-15 Cont ID  
Sent By cpuell Date 2022-02-15 Time 08:27 Rev Time 0.00
Received By cpuell Date 2022-02-15 Time 08:27 Sent To  
Notes
2022-02-15 08:28:15ADDRESS UPDATED TO 579 W EXECUTIVE CENTER DR WITH PCN
 74434319260010000

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-02-14 Cont ID  
Sent By cpuell Date 2022-02-14 Time 14:34 Rev Time 0.00
Received By cpuell Date 2022-02-14 Time 14:34 Sent To  
Notes
2022-02-14 14:34:57PER PERMIT 21081263 ADDRESS NEEDS TO BE ESTABLISHED FOR
 GAS STATION, PLEASE CONTACT [email protected] OR CALL
 561-805-6659

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-09-07 Cont ID  
Sent By rmcphers Date 2022-09-07 Time 16:47 Rev Time 0.00
Received By rmcphers Date 2022-09-07 Time 16:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-03-23 Cont ID  
Sent By rmcphers Date 2022-03-23 Time 13:04 Rev Time 0.00
Received By rmcphers Date 2022-03-23 Time 12:53 Sent To  
Notes
2022-03-23 13:04:20CANOPY
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE THE SOIL REPORT AS REFERENCED ON
 DRAWING F1.
  
 2) WIND DESIGN DATA SHOWN ON THE DRAWINGS AND THE
 CALCULATIONS SHOWS - RISK CATEGORY II WITH A WIND SPEED
 OF 168 - MINIMUM WIND SPEED FOR A RISK CATEGORY II IS
 170MPH PER FBC WPB SECTION 120.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-12-27 Cont ID  
Sent By rmcphers Date 2021-12-27 Time 08:40 Rev Time 0.00
Received By rmcphers Date 2021-12-27 Time 08:28 Sent To  
Notes
2021-12-27 08:40:26CANOPY
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING F1 - THE SOIL CAPACITY NOTES HAVE BLANK
 SPACES - PLEASE REVISE TO SHOW THE REQUIRED SOIL
 BEARING CAPACITY FBC 1808.2 DESIGN FOR CAPACITY AND
 SETTLEMENT.
 FOUNDATIONS SHALL BE SO DESIGNED THAT THE ALLOWABLE
 BEARING CAPACITY OF THE SOIL IS NOT EXCEEDED, AND THAT
 DIFFERENTIAL SETTLEMENT IS MINIMIZED.
  
 2) PLEASE SHOW THE WIND DESIGN DATA USED FOR THE WIND
 DESIGN FBC 1603.1.4
  
 3) PLEASE PROVIDE A SURVEY/SITE PLAN SHOWING THE
 FOLLOWING INFORMATION 107.2.5 SITE PLAN. THE
 CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION
 FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING
 TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND
 EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT
 LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED
 FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE
 AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND
 DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN
 ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY
 LINE SURVEY.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-08-31 Cont ID  
Sent By   Date 2022-08-31 Time   Rev Time 0.00
Received By bdolan Date 2022-08-31 Time 12:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-03-21 Cont ID  
Sent By   Date 2022-03-21 Time   Rev Time 0.00
Received By bdolan Date 2022-03-21 Time 10:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2021-11-22 Time   Rev Time 0.00
Received By jcclark Date 2021-11-22 Time 13:01 Sent To  
Notes
2021-11-22 13:05:50PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
 JOSEPH CLARK
 OFFICE OF THE FIRE MARSHAL
 561-804-4748
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-03-06 Cont ID  
Sent By rmcdouga Date 2023-03-06 Time 11:21 Rev Time 0.00
Received By rmcdouga Date 2023-02-24 Time 07:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-09-27 Cont ID  
Sent By shill Date 2022-09-27 Time 08:33 Rev Time 0.00
Received By shill Date 2022-08-30 Time 16:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-19 Cont ID  
Sent By lmarchan Date 2022-04-19 Time 15:56 Rev Time 0.00
Received By lmarchan Date 2022-03-18 Time 07:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-18 Cont ID  
Sent By lmarchan Date 2022-01-18 Time 11:59 Rev Time 0.00
Received By lmarchan Date 2021-11-18 Time 08:48 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2023-03-06 Cont ID  
Sent By rmcdouga Date 2023-03-06 Time 11:20 Rev Time 0.00
Received By rmcdouga Date 2023-03-06 Time 11:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-09-07 Cont ID  
Sent By rmcphers Date 2022-09-07 Time 16:48 Rev Time 0.00
Received By rmcphers Date 2022-09-07 Time 16:48 Sent To  
Notes
2022-09-07 16:49:57SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) SOIL REPORT (GEOTECHNICAL REPORT) NEEDS TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER.
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-03-23 Cont ID  
Sent By rmcphers Date 2022-03-23 Time 13:08 Rev Time 0.00
Received By rmcphers Date 2022-03-23 Time 13:08 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-12-27 Cont ID  
Sent By rmcphers Date 2021-12-27 Time 08:43 Rev Time 0.00
Received By rmcphers Date 2021-12-27 Time 08:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2023-03-03 Cont ID  
Sent By eschneid Date 2023-03-03 Time 15:32 Rev Time 0.25
Received By eschneid Date 2023-03-03 Time 15:31 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2022-09-26 Cont ID  
Sent By eschneid Date 2022-09-26 Time 17:24 Rev Time 0.25
Received By eschneid Date 2022-09-26 Time 17:00 Sent To  
Notes
2022-09-26 17:25:17FAILED
  
 THE CANOPY COMPLIES WITH ZONING REQUIREMENTS; HOWEVER,
 THIS PERMIT WILL REMAIN WITH A ZONING "FAIL" UNTIL THE
 RECORDED CROSS ACCESS, PARKING, DRAINAGE, ETC AND
 MAINTENANCE AGREEMENT IS PROVIDED.
  

Review Stop Z ZONING
Rev No 2 Status F Date 2022-04-19 Cont ID  
Sent By eschneid Date 2022-04-19 Time 15:51 Rev Time 0.25
Received By eschneid Date 2022-04-19 Time 15:09 Sent To  
Notes
2022-04-19 15:53:51FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) REPEAT COMMENT: THE PROPERTY WAS RECENTLY SUBDIVIDED
 BY THE RECORDATION OF THE PLAT ENTITLED BRANDSMART
 EXECUTIVE CENTER. PRIOR TO ZONING APPROVAL OF THIS
 BUILDING PERMIT, PROVIDE THE PLANNING DIVISION A COPY
 OF THE RECORDED CROSS ACCESS, PARKING, DRAINAGE, ETC
 AND MAINTENANCE AGREEMENTS FOR THE AREA COVERED BY THE
 PLAT. *** THIS ITEM HAS BEEN DISCUSSED WITH THE BJ'S
 LAND USE ATTORNEY, BUT THE REQUIRED INFORMATION HAS NOT
 YET BEEN SATISFACTORILY ADDRESSED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2022-01-14 Cont ID  
Sent By eschneid Date 2022-01-14 Time 16:06 Rev Time 0.25
Received By eschneid Date 2022-01-14 Time 16:06 Sent To  
Notes
2022-01-14 16:06:56FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) THE PROPERTY WAS RECENTLY SUBDIVIDED BY THE
 RECORDATION OF THE PLAT ENTITLED BRANDSMART EXECUTIVE
 CENTER. PRIOR TO ZONING APPROVAL OF THIS BUILDING
 PERMIT, PROVIDE THE PLANNING DIVISION A COPY OF THE
 RECORDED CROSS ACCESS, PARKING, DRAINAGE, ETC AND
 MAINTENANCE AGREEMENTS FOR THE AREA COVERED BY THE
 PLAT.
  
 2) PROVIDE A SITE PLAN SHOWING THE SETBACKS OF THE
 CANOPY FROM THE PROPERTY LINES.
  
 3) PROVIDE DETAILS TO VERIFY THAT THE UNDER CANOPY
 LIGHTS ARE RECESSED OR FLUSH MOUNTED SO AS NOT TO
 CREATE GLARE TO THE SIDES OF THE CANOPY.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  