|
 |
 |
 |
 |
 |
Plan Review Details - Permit 21090695
Plan Review Stops For Permit 21090695 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-11-29 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-11-29 |
Time |
15:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-11-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-11-08 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-11-08 |
Time |
12:52 |
Sent To |
|
|
Notes |
2021-11-08 13:59:44 | BUILDING PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | 3RD REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. THE FLOOR PLAN AND FLOOR PLAN SCHEDULE DO NOT MATCH | | THE SHUTTER SCHEDULE OPENING NUMBERS. (LOCATION AND | | SIZE) | | SHUTTER SCHEDULE INDICATES 7 OPENINGS. FLOOR PLAN | | SCHEDULE INDICATES 6 OPENINGS AND THE FLOOR PLAN ONLY | | SHOWS 5 OPENINGS. | | PLEASE CLARIFY AND RE-SUBMIT. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-11-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-11-01 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-11-01 |
Time |
14:25 |
Sent To |
|
|
Notes |
2021-11-01 14:28:04 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. THE EDGE DISTANCE WAS CHANGED TO 3 1/2", SO THE | | FACTOR IS NO LONGER REQUIRED BUT THE INSTALLATION | | SCHEDULE STILL STATES THAT THERE IS A .9 FACTOR. PLEASE | | REMOVE THIS LANGUAGE OR CLARIFY WHY THE LANGUAGE IS | | THERE. | | | | 2. OPENINGS 6 AND 7 HAVE DESIGN PRESSURES OVER 40PSF, | | BUT 40PSF ANCHOR SPACING IS PROPOSED, SEE PAGE 12. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-10-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-10-16 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-10-16 |
Time |
13:20 |
Sent To |
|
|
Notes |
2021-10-16 13:21:43 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. SEE PAGE 13, A FACTOR OF .9 REQUIRED FOR 3" EDGE | | DISTANCE. 12" IS PROPOSED BUT STATES THAT IT HAS A | | FACTOR OF .9. THE FACTOR IS REQUIRED BUT NOT APPLIED. | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-11-29 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-11-09 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-11-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-11-08 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-11-04 |
Time |
15:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-11-01 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-10-22 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-10-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-10-16 |
Time |
13:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-09-16 |
Time |
06:09 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |