Plan Review Details - Permit 21090534
Plan Review Stops For Permit 21090534 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-20 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-20 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-10-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-10-10 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-10-10 |
Time |
08:55 |
Sent To |
|
|
Notes |
2021-10-10 08:56:37 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. REVISE THE PLAN TO SHOW THAT DOOR #4 (ELECTRIC ROOM) | | IS NOT REQUIRED TO HAVE PANIC DEVICES, FBC B 1010.1.10, | | OR REVISE SUBMITTAL TO PROPOSE PANIC DEVICES ON THIS | | PAIR OF DOORS: | | | | ELECTRICAL ROOMS WITH EQUIPMENT RATED 1,200 AMPERES OR | | MORE AND OVER 6 FEET (1829 MM) WIDE, AND THAT CONTAIN | | OVERCURRENT DEVICES, SWITCHING DEVICES OR CONTROL | | DEVICES WITH EXIT OR EXIT ACCESS DOORS, SHALL BE | | EQUIPPED WITH PANIC HARDWARE OR FIRE EXIT HARDWARE. THE | | DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL. | | | | 2. FOR DOORS 2, 5, AND 6 - REVISE PLAN TO CLARIFY THAT | | THESE DOORS ARE NOT PART OF THE MEANS OF EGRESS FOR | | ASSEMBLY OCCUPANCY WITH AN OCCUPANT LOAD OF 50 OR MORE, | | FBC B 1010.1.10, OR REVISE SUBMITTAL TO PROPOSE PANIC | | HARDWARE: | | | | SWINGING DOORS SERVING . . . ROOMS OR SPACES WITH AN | | OCCUPANT LOAD OF 50 OR MORE IN A GROUP A ... OCCUPANCY | | SHALL NOT BE PROVIDED WITH A LATCH OR LOCK OTHER THAN | | PANIC HARDWARE OR FIRE EXIT HARDWARE. | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2021-10-12 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-20 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-18 |
Time |
13:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-10-13 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-10-13 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-09-17 |
Time |
10:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-20 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-20 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-10-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-10-10 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-10-10 |
Time |
08:49 |
Sent To |
|
|
Notes |
2021-10-10 08:52:28 | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED, SEALED, DATED ORIGINALS. A SCAN OF A SIGNED | | PLAN IS NOT CONSIDERED AN ORIGINAL. | | | | THE WIND LOAD ENGINEERING PREPARED BY SPENCER LEDGARD, | | PE IS NOT DIGITALLY SIGNED; IT APPEARS TO BE A SCAN OF | | A (HAND) SIGNED AND SEALED DOCUMENT. | | | | EITHER UPLOAD DIGITALLY OR ELECTRONICALLY SIGNED | | ENGINEERINGG WITH YOUR RESUBMITTAL (IF APPLICABLE) AND | | COMPLETE THE UPLOAD TASK IN PROJECTDOX, OR YOU CAN | | SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER ORIGINAL | | WITH A WET SIGNATURE TO THE BUILDING DIVISION. | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | DOCUMENTS ARE PREFERRED. | | | | |
|
|
|