Plan Review Details - Permit 21090512
Plan Review Stops For Permit 21090512 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-15 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-15 |
Time |
13:06 |
Sent To |
|
|
Notes |
2021-10-15 13:13:18 | PROVISO ON PG. A-2. SITE WALL, INCLUDING FOUNDATION | | SHALL NOT ENCROACH ONTO ADJACENT PROPERTY. CT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-11-23 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-11-23 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-10-21 |
Time |
10:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-15 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-09-10 |
Time |
15:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2021-09-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-09-10 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-09-10 |
Time |
16:13 |
Sent To |
|
|
Notes |
2021-09-10 16:18:36 | CORPORATE SEAL. NO ARCHITECT OR ENGINEER. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-11-23 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2021-11-23 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2021-11-23 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-09-25 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2021-09-25 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2021-09-25 |
Time |
14:00 |
Sent To |
|
|
Notes |
2021-09-25 14:03:18 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 09.25.2021 | | PERMIT NO.: 21090512 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PLEASE PROVIDE A CROSS SECTION SHOWING THE PROPOSED | | RETAINING WALL IN RELATION TO THE PROPERTY LINE, AS | | WELL AS THE LOCATION OF THE CHAIN LINK FENCE. IF THE | | FENCE IS ON TOP OF THE WALL, THE COMBINED HEIGHT OF THE | | FENCE AND WALL CANNOT EXCEED 6 FEET AS MEASURED FROM | | THE SIDEWALK. IF THE FENCE IS INSET AND SITTING ON | | GRADE INSIDE OF THE RETAINING WALL, THEN THE COMBINED | | HEIGHT RESTRICTION IS NOT APPLICABLE. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
|