Plan Review Details - Permit 21090393
Plan Review Stops For Permit 21090393
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-09-22 Cont ID  
Sent By cpuell Date 2021-09-22 Time 12:58 Rev Time 0.00
Received By cpuell Date 2021-09-22 Time 12:58 Sent To  
Notes
2021-09-22 12:58:29APPLICANT REACHED OUT CONFIRMED THAT THE WORK WAS TO BE
 DONE ON 871 VILLAGE BLVD # 601, UPDATED PERMIT

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-09-16 Cont ID  
Sent By cpuell Date 2021-09-16 Time 15:45 Rev Time 0.00
Received By cpuell Date 2021-09-16 Time 15:45 Sent To  
Notes
2021-09-16 15:46:57THERE IS NO SUITE 601 ON 851 VILLAGE BLVD, SUITE 601
 HAS AN ADDRESS OF 871 VILLAGE BLVD # 601, PLEASE
 CONFIRM TO [email protected] OR CALL 561-805-6659

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 4 Status F Date 2022-04-27 Cont ID  
Sent By rmcphers Date 2022-04-27 Time 12:44 Rev Time 0.00
Received By rmcphers Date 2022-04-27 Time 12:44 Sent To  
Notes
2022-04-27 12:45:04PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status F Date 2021-12-09 Cont ID  
Sent By lmarchan Date 2021-12-09 Time 07:57 Rev Time 0.00
Received By lmarchan Date 2021-12-09 Time 07:57 Sent To  
Notes
2021-12-09 07:57:40PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-11-15 Cont ID  
Sent By rmcphers Date 2021-11-15 Time 13:29 Rev Time 0.00
Received By rmcphers Date 2021-11-15 Time 13:29 Sent To  
Notes
2021-11-15 13:31:09PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-10-20 Cont ID  
Sent By rmcphers Date 2021-10-20 Time 14:32 Rev Time 0.00
Received By rmcphers Date 2021-10-20 Time 14:32 Sent To  
Notes
2021-10-20 14:32:38PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-04-27 Cont ID  
Sent By rmcphers Date 2022-04-27 Time 12:42 Rev Time 0.00
Received By rmcphers Date 2022-04-27 Time 12:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-11-15 Cont ID  
Sent By rmcphers Date 2021-11-15 Time 13:27 Rev Time 0.00
Received By rmcphers Date 2021-11-15 Time 13:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-10-20 Cont ID  
Sent By rmcphers Date 2021-10-20 Time 14:51 Rev Time 0.00
Received By rmcphers Date 2021-10-20 Time 14:32 Sent To  
Notes
2021-10-20 14:38:13INTERIOR ALTERATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) PLEASE SHOW THE BUILDING CONSTRUCTION TYPE - FBC
 602.1
 2) ADDRESS SHOWN ON THE PLANS SHOULD MATCH THE ADDRESS
 SHOWN ON THE BUILDING PERMIT APPLICATION.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-05-17 Cont ID  
Sent By jleahy Date 2022-05-17 Time 07:15 Rev Time 0.00
Received By jleahy Date 2022-05-16 Time 16:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-10-14 Cont ID  
Sent By jleahy Date 2021-10-14 Time 13:05 Rev Time 0.00
Received By jleahy Date 2021-10-01 Time 10:07 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-05-17 Cont ID  
Sent By jleahy Date 2022-05-17 Time 07:15 Rev Time 0.00
Received By jleahy Date 2022-05-17 Time 07:15 Sent To  
Notes
2022-05-17 07:16:25VOICE DATA AND TV JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-04-26 Cont ID  
Sent By cwalker Date 2022-04-26 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-11-12 Cont ID  
Sent By cwalker Date 2021-11-12 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-10-06 Cont ID  
Sent By cwalker Date 2021-10-06 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-05-17 Cont ID  
Sent By jleahy Date 2022-05-17 Time 07:34 Rev Time 0.00
Received By jleahy Date 2022-04-25 Time 07:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-12-09 Cont ID  
Sent By rmcphers Date 2021-12-09 Time 10:23 Rev Time 0.00
Received By rmcphers Date 2021-12-08 Time 11:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-11-17 Cont ID  
Sent By lcrespo Date 2021-11-17 Time 15:33 Rev Time 0.00
Received By lcrespo Date 2021-11-10 Time 16:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-10-21 Cont ID  
Sent By lcrespo Date 2021-10-21 Time 08:10 Rev Time 0.00
Received By lcrespo Date 2021-10-05 Time 08:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-11-12 Cont ID  
Sent By medwards Date 2021-11-12 Time 09:17 Rev Time 0.00
Received By medwards Date 2021-11-12 Time 09:04 Sent To  
Notes
2021-11-12 09:19:14APPROVED WITH PROVISO:
 THE SAUNA INSTALLATION INSTRUCTIONS SHALL BE PRESENTED
 AT THE JOB SITE TO THE INSPECTOR ONCE CHOSEN PER THE
 RESPONSE LETTER FROM THE DESIGNER. ME
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-10-21 Cont ID  
Sent By hmoser Date 2021-10-06 Time 13:39 Rev Time 0.00
Received By hmoser Date 2021-10-06 Time 12:25 Sent To  
Notes
2021-10-21 07:05:01PLAN DENIED
 PLEASE PROVIDE MANUFACTURE INSTALLATION INSTRUCTIONS ON
 SAUNA.
 SECTION 107 FBC 2020
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-04-27 Cont ID  
Sent By lcrespo Date 2022-04-27 Time 10:34 Rev Time 0.00
Received By lcrespo Date 2022-04-27 Time 10:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-11-17 Cont ID  
Sent By lcrespo Date 2021-11-17 Time 15:33 Rev Time 0.00
Received By lcrespo Date 2021-11-17 Time 10:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-10-21 Cont ID  
Sent By lcrespo Date 2021-10-21 Time 08:09 Rev Time 0.00
Received By lcrespo Date 2021-10-20 Time 11:19 Sent To  
Notes
2021-10-21 08:09:2410/21/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON SHEET A1.0
  
 A. IN THE BREAK ROOM 111 AND THE GALLERY AREA 115 SHOWS
 A SINK, WOULD YOU PLEASE GIVE THE DIMESONS 30 INCHES BY
 48 INCHES PER THE 2020 FBC ACC SEC. 305 CLEAR FLOOR OR
 GROUND SPACE.
  
 B. THERE IS AN ELEVATION OF THE BREAK ROOM 110 A-1, BUT
 THE ELEVATION SHOWS THE COUNTER TO AT THREE FEET INCHES
 MAXIMUM AND IT NEEDS TO BE AT 2 FEET 10 INCHES PER THE
 2020 FBC ACC SEC. 606.3.
  
 C. THE SINK IN THE GALLERY SHOWS A CLEAR FLOOR SPACE
 BUT NO DETAIL FOR THE COUNTER HEIGHT; THIS SHOULD BE AT
 34 INCHES MAXIMUM PER THE 2020 FBC ACC SEC. 606.3.
 WOULD YOU PLEASE PROVIDE DETAIL ON THIS PAGE OR GIVE A
 REFERENCE PER THE WPB AMENDMENTS TO THE FBC SEC.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 D. THERE IS A SAUNA IN ROOM 110, AND MECHANICAL IS
 REQUESTING MANUFACTURERS SPECIFICATION. PLEASE PROVIDE
 INFORMATION IF IT IS A STEAM UNIT AND NEEDS HOT WATER
 OR A DRAIN PER THE WPB AMENDMENTS TO THE FBC SEC
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
  
 2. ON SHEET P01;
  
 A. IT SHOWS SANITARY ON THE FLOOR. WOULD YOU PLEASE
 SUBMIT A SLAB REPAIR DETAIL FOR REVIEW? SHOW THE WIDTH
 OF THE REPAIR, THE MINIMUM THICKNESS OF THE CONCRETE TO
 BE REPLACED, AND THE PSI OF THE CONCRETE. SHOW THE SIZE
 AND LENGTH OF THE DOWELS, THE MINIMUM EMBEDMENT DEPTH
 INTO THE EXISTING SLAB, AND THE SPACING OF THE DOWELS
 IN THE CENTER. THE REPAIR MAY ALSO INCLUDE TERMITE
 TREATMENT OF THE SOIL AND THE REQUIRED VAPOR BARRIER
 OVER THE EARTH. A COPY OF THE TERMITE CERTIFICATE SHALL
 BE ONSITE FOR A FINAL INSPECTION IF APPLICABLE.
  
 B. IT SHOWS A WASHING MACHINE THAT WILL REQUIRE A LINT
 TRAP; PLEASE SUPPLY DETAILS OR NOTES PER THE 2020 FBC
 SEC. 1003.6. A MODEL HLT-1176 IS USED A LOT IN OUR
 MUNICIPALITY, AND YOU ARE WELCOME TO USE THIS ONE OR
 ONE SIMILAR. HTTPS://STRIEMCO.COM/WP-CONTENT/UPLOADS/20
 20/03/6010-6025-001-01-HLT-HLB.PDF .
  
 C. THE SERVICE SINK (MOP SINK) SURROUNDING THE WALL
 SHALL BE A NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE
 2020 FBC BUILDING SEC. 1210.2.2 AND 2020 FBC SEC. P
 310.3. WOULD YOU PLEASE MAKE A NOTE ON THIS SHEET?
  
 3. ON SHEET P02;
  
 A. WOULD YOU PLEASE SHOW THE COLD WATER FOR THE
 RESTROOMS AND THE WATER FOUNTAIN PER THE WPB AMENDMENTS
 TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. IF COLD WATER EXISTS, PLEASE SHOW AND LABEL
 IT.
  
 B. WOULD YOU PLEASE SHOW THE HAMMER ARRESTORS ON THE
 WASHING MACHINE PER THE 2020 FBC P 604.9.
  
 C. WOULD YOU PLEASE PUT A NOTE NEXT TO THE WATER HEATER
 FOR DETAIL ON SHEET P-4 PER THE WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 D. THERE ARE HOT WATER LINES IN THE GROUND AND NOT IN
 CONDITION SPACE, SO THEY NEED TO BE INSULATED WITH A
 MINIMUM R-3 PER THE 2020 FBC SEC. RE 403.5.3.
  
 E. THE WATER LINES TO THE SINK IN THE GALLERY FOR THE
 RECIRCULATING MANIFOLD OF THE HOT WATER LINES SHALL BE
 SUPPLIED TO THE SOURCE; PLEASE REFER TO THE 2020 FBC
 ENERGY CODE TABLE C404.5.1. MAXIMUM ALLOWABLE PIPE
 LENGTH METHOD.
  
 F. RECIRCULATING SYSTEM, THE PIPING SHALL BE INSULATED
 IN ITS ENTIRETY, INCLUDING THE SUPPLY AND RETURN PIPING
 OF A CIRCULATING WITH A MIN 1-INCH-THICK PER C404.4 (A)
 INSULATION OF PIPING.
  
 G. ON A GENERAL NOTE, # 3 REFERS TO MIAMI DADE. WOULD
 YOU PLEASE DELETE PER THE WPB AMENDMENTS TO THE FBC
 SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS?
  
 H. WOULD YOU, PLEASE SHOW THE SOURCE LOCATION OF THE
 WATER SERVICE WITH A FULL OPEN VALVE AND A BACKFLOW
 DEVICE INTO THE BUILDING AS REQUIRED PER THE 2020 FBC
 SEC. 606.1 (2) LOCATION OF FULL-OPEN VALVES AND 608.1
 GENERAL.
  
 4. ON SHEET P04;
  
 A. FOR DETAIL P13, WOULD YOU PLEASE SHOW THE RELIEF
 LINE DUMPING NOT MORE THAN 6 INCHES ABOVE AND NOT LESS
 THAN TWO TIMES THE DISCHARGE PIPE DIAMETER ABOVE THE
 FLOOR OR FLOOD LEVEL RIM OF THE WASTE RECEPTOR OR INTO
 THE DRAIN PAN SERVING TANK PER THE 2020 FBC SEC P
 504.6.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-04-27 Cont ID  
Sent By rmcphers Date 2022-04-27 Time 12:40 Rev Time 0.00
Received By rmcphers Date 2022-04-27 Time 12:40 Sent To  
Notes
2022-04-27 12:42:17SIGNATURE REVIEW
  
 DRAWINGS IN THE SIGNATURES FOLDER IN PROJECTDOX A-2.0,
 A-2.1, A-30, AD-1, E01, E02, E03, E04, FP01, FP02, M01,
 M02, M03, P01, P03 DO NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-12-09 Cont ID  
Sent By rmcphers Date 2021-12-09 Time 10:19 Rev Time 0.00
Received By rmcphers Date 2021-12-09 Time 10:19 Sent To  
Notes
2021-12-09 10:23:17SIGNATURE REVIEW
  
 DRAWINGS A-2.0, A-2.1, A-30, AD-1, E01, E02, E03, E04,
 FP01, FP02, M01, M02, M03, P01, P03 DO NOT SHOW AS
 DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-11-15 Cont ID  
Sent By rmcphers Date 2021-11-15 Time 13:26 Rev Time 0.00
Received By rmcphers Date 2021-11-15 Time 13:26 Sent To  
Notes
2021-11-15 13:27:02SIGNATURE REVIEW
  
 ALL OF THE DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-10-20 Cont ID  
Sent By rmcphers Date 2021-10-20 Time 14:51 Rev Time 0.00
Received By rmcphers Date 2021-10-20 Time 14:51 Sent To  
Notes
2021-10-20 14:53:23SIGNATURE REVIEW
  
 ALL OF THE DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX
 NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE
 ENGINEER OR ARCHITECT TO BE USED IN ELECTRONIC PLAN
 REVIEW. (A CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN
 JUST CALLED A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  