Plan Review Stops For Permit 21090372 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-22 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-22 |
Time |
09:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2021-10-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-05 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-05 |
Time |
11:16 |
Sent To |
|
|
Notes |
2021-10-05 11:18:16 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-11-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-02 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-02 |
Time |
13:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-10-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-22 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-22 |
Time |
09:38 |
Sent To |
|
|
Notes |
2021-10-22 09:43:10 | CONDO REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | I CANNOT ACCEPT A FIELD TEST FROM A DIFFERENT BUILDING. | | AN ACOUSTICAL LABORATORY TEST IS REQUIRED - SEE BELOW | | | | THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED: | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.. | | PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING | | SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY | | DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP | | CEILING DESCRIPTION) | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP | | CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING | | ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED | | DROP CEILING DESCRIPTION) | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS | | ATTACHED TO THE FLOORING) | | | | YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO VERIFY | | THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING TO | | PROJECTDOX ( [email protected] ) | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-10-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-05 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-05 |
Time |
11:18 |
Sent To |
|
|
Notes |
2021-10-05 11:21:16 | CONDO REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | 1) PLEASE PROVIDE A WRITTEN SCOPE OF WORK ON THE | | DRAWINGS. | | | | IF YOU ARE REPLACING FLOORING - | | THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED: | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.. | | PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING | | SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY | | DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP | | CEILING DESCRIPTION) | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP | | CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING | | ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED | | DROP CEILING DESCRIPTION) | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS | | ATTACHED TO THE FLOORING) | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2021-10-05 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-10-05 |
Time |
22:19 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-10-05 |
Time |
21:35 |
Sent To |
|
|
Notes |
2021-10-05 22:19:31 | NO ELECTRICAL REVIEWED OR APPROVED. | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2021-09-10 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2021-09-10 |
Time |
|
Rev Time |
|
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-11-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-02 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-29 |
Time |
08:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-10-26 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-10-14 |
Time |
09:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-10-05 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-10-05 |
Time |
22:20 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-09-09 |
Time |
10:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2021-09-21 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-09-21 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-09-21 |
Time |
16:54 |
Sent To |
|
|
Notes |
2021-09-21 16:55:06 | APPEARS TO BE A KITCHEN CABINET REMODEL. NO MECHANICAL | | WORK SHOWN. ME |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-10-26 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-10-26 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-10-26 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-09-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-09-27 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-09-27 |
Time |
10:21 |
Sent To |
|
|
Notes |
2021-09-27 10:56:24 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 21090372 | | 9/27/21 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE PLUMBING PLANS INCLUDING A SCOPE OF WORK | | OUTLINE WITH CORRESPONDING DRAWINGS AND DETAILS- | | SECTION 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2021-10-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-05 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-05 |
Time |
11:22 |
Sent To |
|
|
Notes |
|
|