Plan Review Stops For Permit 21081626 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-11-29 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-11-29 |
Time |
15:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-09-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-09-27 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-09-27 |
Time |
16:51 |
Sent To |
|
|
Notes |
2021-09-27 16:52:10 | CONTRACTOR CLARIFIED THAT THE 2' RAISED WALL IS | | EXISTING. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-09-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-09-24 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-09-24 |
Time |
08:08 |
Sent To |
|
|
Notes |
2021-09-24 08:18:19 | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT STRUCTURAL DETAILS TO SHOW HOW THE POOL WALL | | WILL BE RAISED 24". SPECIFY THE REINFORCING AND | | DOWELING INTO THE EXISTING POOL WALL. FBC AMENDMENTS | | 107.2.1 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2021-11-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-11-14 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-11-14 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-09-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-09-08 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-09-08 |
Time |
13:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-09-07 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-09-07 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-09-07 |
Time |
15:50 |
Sent To |
|
|
Notes |
2021-09-07 15:56:47 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | STAND LIGHTS NOT LISTED FOR USE IN POOLS. SEE SPEC | | SHEET. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2021-09-16 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-09-16 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-09-16 |
Time |
09:47 |
Sent To |
|
|
Notes |
2021-09-16 09:47:06 | PER CONTRACTOR THEY SAYS LIKE FOR LIKE BUT NO | | INFORMATION FOUND IN CITY RECORD FOR A GAS HEATER. | | FIELD INSPECTOR MAY FIND THAT THE GAS IS NOT UP TO CODE | | AND A PERMIT FOR GAS MAY BE REQUIRED PER THE WPB | | AMENDMENTS TO THE FBC SEC. 105.1. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-11-29 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-11-03 |
Time |
16:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-09-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-09-27 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-09-27 |
Time |
16:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-09-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-09-24 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-09-03 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-11-04 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-11-04 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-11-04 |
Time |
11:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-09-14 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-09-13 |
Time |
20:43 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-09-13 |
Time |
20:43 |
Sent To |
|
|
Notes |
2021-09-13 20:43:50 | 09/13/21 1ST POOL REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. WOULD YOU PLEASE SUBMIT TOTAL DYNAMIC HEAD | | CALCULATIONS FOR THE MAXIMUM SYSTEM FLOW COMPONENTS? IT | | REQUIRES THAT THE MAXIMUM SYSTEM FLOW RATE DOES NOT | | EXCEED THE LISTED MAXIMUM FLOW RATE OF THE SUCTION | | OUTLET FITTING ASSEMBLY (DRAIN COVER). THE TDH | | CALCULATIONS MUST INCLUDE ALL THE SYSTEM COMPONENTS | | INCLUDING SUCTION AND RETURN PIPING, FITTINGS, VALVES, | | HEATER, FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS | | EXCEPT THE PUMP PER THE ANSI/APSP/ICC 7 - 2015 SECS. | | 4.4.9, 4.4.9.1 MAXIMUM SYSTEM FLOW RATE?UNSECURED | | CONTROL SYSTEMS. | | | | 2. WOULD YOU PLEASE SUBMIT A COPY OF THE POOL PUMP | | CURVE. IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS | | SPECIFIC TO THE PUMP BEING INSTALLED ON THIS POOL. THIS | | IS NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE | | TDH CALCULATIONS PER THE ANSI/APSP/ICC 7 - 2015 SECS. | | 4.4.9, 4.4.9.1. | | | | 3. THE POOL HEATER IS NEW AND IT NEEDS TO BE IN THE TDH | | CALCULATION. | | | | 4. WOULD YOU PLEASE PROVIDE THE MANUFACTURES | | SPECIFICATIONS FOR THE POOL HEATER AND CHLORINATOR? | | | | 5. A SUB GAS PERMIT IS REQUIRED BY A LICENSED | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | TO THE FBC SEC. 105.1. | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-11-29 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-11-29 |
Time |
15:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-09-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-09-24 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-09-24 |
Time |
08:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2021-09-17 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2021-09-17 |
Time |
|
Sent To |
|
|
Notes |
2021-09-17 13:49:34 | * SEPARATE PERMIT REQUIRED FOR THE PROPOSED FOUNTAIN AT | | THE NORTH END OF THE PROPERTY. |
|
|