Plan Review Details - Permit 21081414
Plan Review Stops For Permit 21081414 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2021-12-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-12-03 |
Time |
06:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-12-03 |
Time |
06:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-10-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-10-03 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-10-03 |
Time |
08:33 |
Sent To |
|
|
Notes |
2021-10-03 08:41:31 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | BECAUSE IT APPEARS THAT THE APPLICANT BELIEVES THAT ONE | | OF THE SINGLE HUNG WINDOWS SHOULD HAVE DESIGN PRESSURES | | FOR OPENING 3 (AS WELL AS THE SLIDING GLASS DOOR), | | PROVIDE A FLOOR PLAN PREPARED BY THE ENGINEER WHICH | | TIES THE OPENINGS TO THE DESIGN PRESSURES SPECIFIED. | | | | FROM PREVIOUS LISTS, NO NEW DOCUMENTS UPLOADED FOR 3RD | | SUBMITTAL EXCEPT FOR A FLOOR PLAN WHICH STILL HAS TWO | | OPENINGS MARKED #3. | | | | SEE THE ENGINEERING; YOU HAVE WHAT THE ENGINEER REFERS | | TO AS "MARK 1-2, 4-5" AND ALSO "MARK 3". MARKS 1-2 AND | | 4-5 REQUIRE DESIGN PRESSURES OF +62.7/-62.7. SUBMIT A | | FLOOR PLAN PREPARED BY THE ENGINEER THAT CLEARLY SHOWS | | WHICH OPENINGS CORRELATE WITH THE DESIGN PRESSURES. | | | | THE FLOOR PLAN PREPARED BY THE CONTRACTOR HAS TWO | | OPENINGS LABELED AS #3, AND THE PRODUCT APPROVAL OPTION | | FOR -60/+80 MARKED ON PAGE 2 OF THE SINGLE HUNG PRODUCT | | APPROVAL. THIS IS THE 3RD REVIEW OF THE SAME DOCMENTS. | | | | REVISE THE SINGLE HUNG PRODUCT APPROVAL ON DRAWING PAGE | | 2 SO THAT YOU INDICATE THAT +80/-80 OPTION IS PROPOSED, | | OR HAVE THE ENGINEER REDUCE THE REQUIRED PRESSURES. THE | | PRODUCT APPROVAL PROPOSES THE STANDARD SILL, BUT THE | | STANDARD SILL HAS A LIMITATION OF -60/+80. THE HI-RISE | | FRAME SILL HAS A DESIGN PRESSURE LIMITATION OF -80/+80. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-09-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-09-21 |
Time |
17:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-09-21 |
Time |
17:09 |
Sent To |
|
|
Notes |
2021-09-21 17:12:26 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | FROM PREVIOUS LIST, NO NEW DOCUMENTS UPLOADED. THE S&S | | ENGINEERING WAS UPLOADED TO THE SIGNATURE FOLDER, BUT | | THIS WAS ALREADY REVIEWED IN THE SUPPORTING DOCS FOLDER | | WITH NO ISSUES. THE ISSUE IS THAT THE FLOOR PLAN HAS | | TWO OPENINGS LABELED AS #3, AND THE PRODUCT APPROVAL | | OPTION FOR -60/+80 MARKED ON PAGE 2 OF THE SINGLE HUNG | | PRODUCT APPROVAL. | | | | WHEN RESUBMITTING, REVISE THE FLOOR PLAN SO THERE IS | | ONLY ONE OPENING LABELED #3. | | | | REVISE THE SINGLE HUNG PRODUCT APPROVAL ON PAGE 2 SO | | THAT YOU INDICATE THAT +80/-80 OPTION IS PROPOSED. | | | | COMMENTS FROM PREVIOUS LIST: | | | | 1. FBC B 1609, SEE THE SINGLE HUNG WINDOW PRODUCT | | APPROVAL, PAGE 2. MAX DESIGN PRESSURE +60/-80 IS | | MARKED. THAT DOES NOT MEET THE MINIMUM SPECIFIED BY THE | | ENGINEER (+-62.7), ALSO IS NOT CONSISTENT WITH THE | | WINDOW SCHEDULE. | | | | 2. THE FLOOR PLAN HAS TWO OPENINGS MARKED AS #3, FBC | | 107 PLEASE REVISE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-09-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-09-10 |
Time |
17:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-09-10 |
Time |
17:24 |
Sent To |
|
|
Notes |
2021-09-10 17:30:16 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC B 1609, SEE THE SINGLE HUNG WINDOW PRODUCT | | APPROVAL, PAGE 2. MAX DESIGN PRESSURE +60/-80 IS | | MARKED. THAT DOES NOT MEET THE MINIMUM SPECIFIED BY THE | | ENGINEER (+-62.7), ALSO IS NOT CONSISTENT WITH THE | | WINDOW SCHEDULE. | | | | 2. THE FLOOR PLAN HAS TWO OPENINGS MARKED AS #3, FBC | | 107 PLEASE REVISE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-12-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-12-03 |
Time |
06:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-11-09 |
Time |
08:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-10-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-10-03 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-09-28 |
Time |
08:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-09-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-09-21 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-09-17 |
Time |
12:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-09-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-09-10 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-08-31 |
Time |
13:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-09-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-09-10 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-09-10 |
Time |
17:30 |
Sent To |
|
|
Notes |
|
|
|