Plan Review Details - Permit 21081414
Plan Review Stops For Permit 21081414
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-12-03 Cont ID  
Sent By shill Date 2021-12-03 Time 06:37 Rev Time 0.00
Received By shill Date 2021-12-03 Time 06:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-10-03 Cont ID  
Sent By shill Date 2021-10-03 Time 08:33 Rev Time 0.00
Received By shill Date 2021-10-03 Time 08:33 Sent To  
Notes
2021-10-03 08:41:31****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BECAUSE IT APPEARS THAT THE APPLICANT BELIEVES THAT ONE
 OF THE SINGLE HUNG WINDOWS SHOULD HAVE DESIGN PRESSURES
 FOR OPENING 3 (AS WELL AS THE SLIDING GLASS DOOR),
 PROVIDE A FLOOR PLAN PREPARED BY THE ENGINEER WHICH
 TIES THE OPENINGS TO THE DESIGN PRESSURES SPECIFIED.
  
 FROM PREVIOUS LISTS, NO NEW DOCUMENTS UPLOADED FOR 3RD
 SUBMITTAL EXCEPT FOR A FLOOR PLAN WHICH STILL HAS TWO
 OPENINGS MARKED #3.
  
 SEE THE ENGINEERING; YOU HAVE WHAT THE ENGINEER REFERS
 TO AS "MARK 1-2, 4-5" AND ALSO "MARK 3". MARKS 1-2 AND
 4-5 REQUIRE DESIGN PRESSURES OF +62.7/-62.7. SUBMIT A
 FLOOR PLAN PREPARED BY THE ENGINEER THAT CLEARLY SHOWS
 WHICH OPENINGS CORRELATE WITH THE DESIGN PRESSURES.
  
 THE FLOOR PLAN PREPARED BY THE CONTRACTOR HAS TWO
 OPENINGS LABELED AS #3, AND THE PRODUCT APPROVAL OPTION
 FOR -60/+80 MARKED ON PAGE 2 OF THE SINGLE HUNG PRODUCT
 APPROVAL. THIS IS THE 3RD REVIEW OF THE SAME DOCMENTS.
  
 REVISE THE SINGLE HUNG PRODUCT APPROVAL ON DRAWING PAGE
 2 SO THAT YOU INDICATE THAT +80/-80 OPTION IS PROPOSED,
 OR HAVE THE ENGINEER REDUCE THE REQUIRED PRESSURES. THE
 PRODUCT APPROVAL PROPOSES THE STANDARD SILL, BUT THE
 STANDARD SILL HAS A LIMITATION OF -60/+80. THE HI-RISE
 FRAME SILL HAS A DESIGN PRESSURE LIMITATION OF -80/+80.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-09-21 Cont ID  
Sent By shill Date 2021-09-21 Time 17:09 Rev Time 0.00
Received By shill Date 2021-09-21 Time 17:09 Sent To  
Notes
2021-09-21 17:12:26****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 FROM PREVIOUS LIST, NO NEW DOCUMENTS UPLOADED. THE S&S
 ENGINEERING WAS UPLOADED TO THE SIGNATURE FOLDER, BUT
 THIS WAS ALREADY REVIEWED IN THE SUPPORTING DOCS FOLDER
 WITH NO ISSUES. THE ISSUE IS THAT THE FLOOR PLAN HAS
 TWO OPENINGS LABELED AS #3, AND THE PRODUCT APPROVAL
 OPTION FOR -60/+80 MARKED ON PAGE 2 OF THE SINGLE HUNG
 PRODUCT APPROVAL.
  
 WHEN RESUBMITTING, REVISE THE FLOOR PLAN SO THERE IS
 ONLY ONE OPENING LABELED #3.
  
 REVISE THE SINGLE HUNG PRODUCT APPROVAL ON PAGE 2 SO
 THAT YOU INDICATE THAT +80/-80 OPTION IS PROPOSED.
  
 COMMENTS FROM PREVIOUS LIST:
  
 1. FBC B 1609, SEE THE SINGLE HUNG WINDOW PRODUCT
 APPROVAL, PAGE 2. MAX DESIGN PRESSURE +60/-80 IS
 MARKED. THAT DOES NOT MEET THE MINIMUM SPECIFIED BY THE
 ENGINEER (+-62.7), ALSO IS NOT CONSISTENT WITH THE
 WINDOW SCHEDULE.
  
 2. THE FLOOR PLAN HAS TWO OPENINGS MARKED AS #3, FBC
 107 PLEASE REVISE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-10 Cont ID  
Sent By shill Date 2021-09-10 Time 17:24 Rev Time 0.00
Received By shill Date 2021-09-10 Time 17:24 Sent To  
Notes
2021-09-10 17:30:16****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC B 1609, SEE THE SINGLE HUNG WINDOW PRODUCT
 APPROVAL, PAGE 2. MAX DESIGN PRESSURE +60/-80 IS
 MARKED. THAT DOES NOT MEET THE MINIMUM SPECIFIED BY THE
 ENGINEER (+-62.7), ALSO IS NOT CONSISTENT WITH THE
 WINDOW SCHEDULE.
  
 2. THE FLOOR PLAN HAS TWO OPENINGS MARKED AS #3, FBC
 107 PLEASE REVISE.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-12-03 Cont ID  
Sent By shill Date 2021-12-03 Time 06:37 Rev Time 0.00
Received By shill Date 2021-11-09 Time 08:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-10-03 Cont ID  
Sent By shill Date 2021-10-03 Time 08:48 Rev Time 0.00
Received By shill Date 2021-09-28 Time 08:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-21 Cont ID  
Sent By shill Date 2021-09-21 Time 17:15 Rev Time 0.00
Received By shill Date 2021-09-17 Time 12:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-10 Cont ID  
Sent By shill Date 2021-09-10 Time 17:30 Rev Time 0.00
Received By shill Date 2021-08-31 Time 13:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-09-10 Cont ID  
Sent By shill Date 2021-09-10 Time 17:30 Rev Time 0.00
Received By shill Date 2021-09-10 Time 17:30 Sent To  
Notes
***NONE***