Plan Review Stops For Permit 21081271 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2021-09-27 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-09-27 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-09-27 |
Time |
15:39 |
Sent To |
|
|
Notes |
2021-09-27 15:41:00 | WORK TO BE DONE ON THE FRONT HOUSE ONLY - 317 VALLETTE | | WAY. TWO ADDITIONAL ADDRESSES ADDED TO THE ACCESSORY | | BUILDINGS 317 & 319 VALLETTE WAY |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2021-09-27 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-09-27 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-09-27 |
Time |
11:40 |
Sent To |
|
|
Notes |
2021-09-27 11:41:47 | PLEASE COORDINATE WITH [email protected] FOR THE LIVABLE | | SPACES TO BE GIVEN AN ADDRESS. ALL ACCESSORY | | RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER HABITABLE | | STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY ADDRESS | | NUMBER PER CITY'S ADDRESSING POLICY. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-10-15 |
Time |
19:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-10-15 |
Time |
19:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-09-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-09-24 |
Time |
19:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-09-24 |
Time |
19:23 |
Sent To |
|
|
Notes |
2021-09-24 19:27:42 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC 107 IT APPEARS THAT MORE THAN ONE STRUCTURE IS | | AFFECTED BY THE PROPOSED WORK. A SEPARATE PERMIT IS | | REQUIRED FOR EACH STRUCTURE. EMAIL THE PERMIT | | APPLICATION TO [email protected] IF MORE THAN ONE | | STRUCTURE IS AFFECTED. IF ONLY ONE STRUCTURE IS | | INCLUDED IN THE SCOPE OF WORK, REVISE THE SITE PLAN TO | | CLARIFY. | | | | THE PLANS WILL BE STAMPED WITH BOTH PERMIT NUMBERS; NO | | NEED TO UPLOAD ADDITIONAL PLANS. THE VALUE, HOWEVER, | | DOES NEED TO BE ASSIGNED TO EACH PERMIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-10-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-21 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-21 |
Time |
15:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-09-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-09-25 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-09-25 |
Time |
05:37 |
Sent To |
|
|
Notes |
2021-09-25 07:46:42 | PLAN REVIEW / ELECTRICAL | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE: WORK APPEARS TO BE FOR 2-STORY PRIMARY | | STRUCTURE. IDENTIFY STRUCTURE ON SITE PLAN. | | | | 1. PROVIDE AN UPDATED PANEL SCHEDULE. | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | 2. PROVIDE A GFCI PROTECTED OUTLET FOR DISPOSAL. | | E3902.10 | | | | 3. PROVIDE A GFCI PROTECTED OUTLET FOR 1ST FLOOR POWDER | | ROOM. | | E3901.6 | | | | 4. PROVIDE WALL OUTLET IN RE-LOCATED LAUNDRY ROOM. | | E3901.2.1 | | | | 5. OUTLET AT 2ND FLOOR SINK SHALL BE GFCI PROTECTED. | | E3902.6 | | | | 6. INSTALL WALL OUTLET AT KITCHEN CORNER (24 INCHES)) | | E3901.2.2 | | | | 7. KITCHEN COUNTER RECEPTACLES SHALL COMPLY WITH | | E3901.4. | | FIGURE E3901.4 | | | | 8. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | FBC EC C405.1, R404.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2021-09-16 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-09-16 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-09-16 |
Time |
09:16 |
Sent To |
|
|
Notes |
2021-09-16 09:17:26 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | SEC. 105.1. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-10-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-21 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-13 |
Time |
06:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-09-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-09-25 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-09-07 |
Time |
12:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-10-14 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-10-14 |
Time |
08:06 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-10-14 |
Time |
08:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-09-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-09-08 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-09-08 |
Time |
10:00 |
Sent To |
|
|
Notes |
2021-09-08 10:12:53 | PLEASE PROVIDE A MECHANICAL SCOPE OF WORK FOR THIS | | PROJECT. PLEASE PROVIDE THE HOOD DETAILS, WHAT ARE THE | | CFM'S OF REQUIRED EXHAUST. IS MAKE UP AIR REQUIRED? FBC | | 107.2.1 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-10-19 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-10-19 |
Time |
15:43 |
Sent To |
|
|
Notes |
2021-10-19 15:48:36 | 10/19/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-09-16 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-09-16 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-09-16 |
Time |
08:51 |
Sent To |
|
|
Notes |
2021-09-16 09:16:41 | 09/16/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-10-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-10-21 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-10-21 |
Time |
15:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-09-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-09-08 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-09-08 |
Time |
10:13 |
Sent To |
|
|
Notes |
|
|