2021-08-24 10:06:43 | 1ST REVIEW FBC-2020 RES. BUILDING. |
| PERMIT- 21080963 |
| 8/24/2021 |
| |
| CODES IN EFFECT: |
| FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| 2020 |
| FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) THE SUBMITTED MIAMI-DADE NOA FOR THE FLAT ROOF- |
| 18-0919.12 REQUIRES ADDITIONAL ENGINEERING FOR ENHANCED |
| BASE SHEET FASTENING. PLEASE REFER TO NOTE #7 ON PAGE |
| 67 AND PROVIDE ENGINEERED CALCULATIONS FOR INCREASED |
| MECHANICAL FASTENING OF BASE SHEETS AT PERIMETER AND |
| CORNER AREAS OF THE ROOF. THE CALCULATIONS AND |
| FASTENING DETAILS SHALL BE PREPARED BY A FL. REGISTERED |
| DESIGN OR REGISTERED ROOF CONSULTANT. CALCULATIONS AND |
| DETAILS BY FL. LICENSED ENGINEERS OR ARCHITECTS SHALL |
| BEAR THE SEAL AND SIGNATURE OF THE DESIGN PROFESSIONAL. |
| THE ENGINEERING MAY BE SUBMITTED IN DUPLICATE PAPER |
| FORM (TWO COPIES SIGNED AND SEALED) TO WPB BUILDING |
| DEPARTMENT OR CAN BE SENT ELECTRONICALLY WITH THE |
| DIGITAL SIGNATURE AND SEAL OF THE DESIGN PROFESSIONAL- |
| FL. STATUTES 471.025 AND 481.221. |
| |
| 2) MIAMI-DADE NOA 20-0902.02 VEREA ROOF TILE: PLEASE |
| REFER TO PAGE 4- LIMITATIONS 3.4 & 3.5 AND INDICATE |
| WHICH ROOF UNDERLAYMENT SYSTEM WILL BE INSTALLED- |
| SECTION 905.3.3 FBC RES. INSTALLATION OF MANUFACTURED |
| UNDERLAYMENT REQUIRES SUBMITTAL OF A FLORIDA PRODUCT |
| APPROVAL OR MIAMI-DADE NOA. |
| |
| 3) SUBMIT A FLORIDA PRODUCT APPROVAL OR MIAMI-DADE NOA |
| FOR THE TILE RIDGE/HIP METAL CHANNEL- FAC RULE 9N-3. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |