Plan Review Details - Permit 21080597
Plan Review Stops For Permit 21080597 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2021-08-26 |
|
|
Cont ID |
|
Sent By |
|
Date |
2021-08-26 |
Time |
|
Rev Time |
0.00 |
Received By |
bdolan |
Date |
2021-08-26 |
Time |
14:05 |
Sent To |
|
|
Notes |
2021-08-26 14:07:35 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | INSPECTIONS AND APPROVAL. | | | | THIS PLAN WAS REVIEWED AND APPROVED BY THE FIRE | | DEPARTMENT, WITH THE FOLLOWING COMMENTS: | | | | HYDROSTATIC TESTS. ALL PIPING AND ATTACHED | | APPURTENANCES SUBJECTED TO SYSTEM WORKING PRESSURE | | SHALL BE HYDROSTATICALLY TESTED AT 200 PSI (13.8 BAR) | | AND SHALL MAINTAIN THAT PRESSURE WITHOUT LOSS FOR 2 | | HOURS. | | | | LT. BRIAN DOLAN | | DIVISION OF FIRE PREVENTION | | 561-804-4752 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2021-08-16 |
|
|
Cont ID |
|
Sent By |
|
Date |
2021-08-16 |
Time |
|
Rev Time |
0.00 |
Received By |
bdolan |
Date |
2021-08-16 |
Time |
10:55 |
Sent To |
|
|
Notes |
2021-08-16 10:57:08 | PLAN SHEET IS TITLED "FIRE ALARM DEMOLITION". | | | | PERMIT IS LISTED AS SPRINKLER PLAN. | | | | PLEASE SUBMIT CORRECT SHEET WITH PERMIT. | | | | LT. BRIAN DOLAN | | DIVISION OF FIRE PREVENTION | | 561-804-4752 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-09-07 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-09-03 |
Time |
16:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-08-27 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-08-27 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-19 |
Time |
15:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-08-27 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-08-27 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-12 |
Time |
13:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2021-08-23 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2021-08-23 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2021-08-23 |
Time |
13:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-09-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-09-07 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-09-07 |
Time |
10:54 |
Sent To |
|
|
Notes |
2021-09-07 18:34:39 | | | REVIEW OF SIGNATURE AND SEAL ON PAPER PLANS AND/OR | | DOCUMENTS APPROVED AND PLANS ROUTED TO STORAGE. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-08-27 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-08-27 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-27 |
Time |
09:54 |
Sent To |
|
|
Notes |
2021-08-27 09:55:42 | PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN | | PROFESSIONAL OR THE CONTRACTOR QUALIFIER. FS | | 471.003(2)(H); 471.025; FBC 107.2.1 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2021-08-19 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2021-08-19 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2021-08-19 |
Time |
15:47 |
Sent To |
|
|
Notes |
|
|
|