Plan Review Details - Permit 21071476
Plan Review Stops For Permit 21071476 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
N |
Date |
2021-08-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-16 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-08-16 |
Time |
14:42 |
Sent To |
|
|
Notes |
2021-08-16 14:43:52 | NO DEMO |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
N |
Date |
2021-08-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-16 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-08-16 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-08-18 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-08-18 |
Time |
19:18 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-08-18 |
Time |
18:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2021-08-05 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-08-05 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-08-05 |
Time |
11:30 |
Sent To |
|
|
Notes |
2021-08-05 11:33:58 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS NO FLOOR PLAN INDICATING THE LOCATION OF | | THE BATHROOM FOR THE PROPOSED WLAK-IN TUB. | | | | PLEASE PROVIDE THAT FLOOR PLAN. | | | | | | 1A) BASED ON THE FLOOR PLAN AND THE LOCATION OF THE | | BATHROOM, IT MAY BE LOCATED ON A TENANT SEPARATION FIRE | | RATED WALL. | | | | PLEASE REVIEW AND ENSURE A NOTE IS PROVIDED INDICATED | | THE FIRE WALL BE BE MAINTAINED OR REPAIRED TO MATCH THE | | REQUIRED RATING. | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-08-20 |
Time |
|
Rev Time |
0.00 |
Received By |
cdecoeur |
Date |
2021-08-02 |
Time |
14:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-08-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-08-20 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-08-17 |
Time |
15:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2021-08-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-16 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-08-16 |
Time |
14:44 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy