Plan Review Stops For Permit 21071336 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-22 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-22 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2021-10-07 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-07 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-07 |
Time |
13:49 |
Sent To |
|
|
Notes |
2021-10-07 13:50:00 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2021-08-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-10 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-08-10 |
Time |
14:27 |
Sent To |
|
|
Notes |
2021-08-10 14:28:29 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-22 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-22 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-10-07 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-07 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-07 |
Time |
13:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-08-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-10 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-08-10 |
Time |
14:27 |
Sent To |
|
|
Notes |
2021-08-10 14:36:21 | CONDO REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - | | | | 1) THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED: | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.. | | PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING | | SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY | | DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP | | CEILING DESCRIPTION) | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP | | CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING | | ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED | | DROP CEILING DESCRIPTION) | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS | | ATTACHED TO THE FLOORING) | | | | 2). YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO | | VERIFY THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING | | TO PROJECTDOX ( [email protected] ) | | 3) PLEASE SHOW THE FLOORING TYPE TO BE USED ON THE | | FLOOR PLAN (WOOD, TILE ETC.). | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2021-11-02 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-11-02 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-11-02 |
Time |
16:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-10-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-10-13 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-10-13 |
Time |
14:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-08-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-08-09 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-09 |
Time |
15:48 |
Sent To |
|
|
Notes |
2021-08-09 15:53:24 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | NO ELECTRICAL WORK SHOWN. PLEASE INDICATE ON PLANS ANY | | ELECTRICAL WORK TO BE DONE OR PLACE A NOTE ON PLANS | | STATING "NO ELECTRCIAL WORK TO BE DONE." |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2021-10-15 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2021-10-01 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2021-10-01 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2021-08-05 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2021-08-05 |
Time |
|
Rev Time |
|
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-11-02 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-11-02 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-10-14 |
Time |
09:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-10-13 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-09-29 |
Time |
09:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-08-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-10 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-08-02 |
Time |
13:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
N |
Date |
2021-10-20 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-10-20 |
Time |
06:26 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-10-20 |
Time |
06:26 |
Sent To |
|
|
Notes |
2021-10-20 06:27:02 | THERE IS NO MECHANICAL WORK SHOWN ON THE PLANS FOR THIS | | PROJECT. ME |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2021-10-05 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-10-05 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-10-05 |
Time |
16:06 |
Sent To |
|
|
Notes |
2021-10-05 16:13:21 | THE MEP SHEET HAS A SECTION HEADED AS AIR CONDITIONING | | NOTES THAT INDICATES THAT THE MECHANICAL CONTRACTOR | | WILL INSTALL A COMPLETE AND OPERATING A/C SYSTEM BUT | | THE NOTE AT THE BOTTOM LEFT OF THE SHEET IS REVISED TO | | INDICATE THE MECHANICAL SCOPE OF WORK IS TO REPLACE | | EXISTING EXHAUST FANS AS PER PLANS. PLEASE CLEAR THIS | | UP, IS THERE GOING TO BE NEW MECHANICAL SYSTEMS | | INSTALLED? IF SO PLEASE PROVIDE THE MECHANICAL | | EQUIPMENT SIZING CALCULATIONS. IF NOT PLEASE REMOVE THE | | AIR CONDITIONING NOTES SECTION. PROVIDE A COMPLETE | | SCOPE OF WORK FOR THE MECHANICAL AND A MECHANICAL | | SUBPERMIT WILL BE REQUIRED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-08-09 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-09 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-09 |
Time |
11:01 |
Sent To |
|
|
Notes |
2021-08-09 11:03:44 | NOTE 20 IN THE GENERAL NOTES INDICATES MECHANICAL WORK | | BEING DONE FOR THIS PROJECT. PLEASE PROVIDE A COMPLETE | | SCOPE OF WORK FOR ALL OF THE MECHANICAL WORK BEING | | INSTALLED FOR THIS PROJECT. FBC 107.2.1 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2021-10-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-10-27 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-10-26 |
Time |
14:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-10-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-10-13 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-10-13 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-08-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-08-09 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-08-09 |
Time |
10:46 |
Sent To |
|
|
Notes |
2021-08-09 10:59:48 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 21071336 | | 8/9/21 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET CVR: THE INDEX SHOWS MISSING PLAN SHEETS A3 | | AND MEP-1 NOT UPLOADED FOR REVIEW. PLAN SHEET A1 | | REFERENCES SHEET P1 NOT UPLOADED FOR REVIEW. PLEASE | | PROVIDE THE MISSING SHEETS- SECTION 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
P |
Date |
2021-08-04 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2021-08-04 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2021-08-04 |
Time |
15:55 |
Sent To |
|
|
Notes |
2021-08-04 15:56:50 | PRIVATE PROVIDER INSPECTIONS ONLY APPROVED | | RICHARD GATHRIGHT |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-22 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-22 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-10-07 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-07 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-07 |
Time |
13:52 |
Sent To |
|
|
Notes |
2021-10-07 13:53:22 | SIGNATURE REVIEW | | | | DRAWINGS NEED TO BE SIGNED AND SEALED BY THE DESIGNER. | | FBC WPB 107.1 | | | | DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER | | OR ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR | | - IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN | | ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL. | | | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-08-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-10 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-08-10 |
Time |
14:36 |
Sent To |
|
|
Notes |
2021-08-10 14:40:06 | SIGNATURE REVIEW | | | | DRAWINGS NEED TO BE SIGNED AND SEALED BY THE DESIGNER. | | FBC WPB 107.1 | | | | DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER | | OR ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR | | - IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN | | ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL. | | |
|
|