Plan Review Stops For Permit 21071298 |
Review Stop |
AD |
ADDRESSING |
Rev No |
5 |
Status |
P |
Date |
2021-11-22 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-11-22 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-11-22 |
Time |
13:50 |
Sent To |
|
|
Notes |
2021-11-22 13:53:24 | PARCEL MERGED PCN 74434322360044040 AND | | 74434322360044050 TO CREATE A SINGLE PCN | | 74434322360044040, UNIT 404 WILL BE RETIRED AND UNIT | | 405 WILL REMAIN AS THE SOLE UNIT NUMBER FOR THE MERGED | | PARCEL.. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
4 |
Status |
F |
Date |
2021-11-01 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-11-01 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-11-01 |
Time |
09:56 |
Sent To |
|
|
Notes |
2021-11-01 09:56:49 | THANK YOU FOR UPLOADING THE UNITY OF TITLE, YOU NEXT | | STEPS ARE TO CONTACT THE PROPERTY APPRAISERS AND | | REQUEST A UNIFIED PARCEL CONTROL NUMBER FOR THE UNITS. | | ONCE THIS IS DONE, PLEASE CONATCT ME [email protected] OR | | CALL 561-805-6659 TO BE ISSUED A SINGLE ADDRESS. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
F |
Date |
2021-10-14 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-10-14 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-10-14 |
Time |
09:04 |
Sent To |
|
|
Notes |
2021-10-14 09:05:56 | THANK YOU FOR UPLOADING THE UNITY OF TITLE, YOU NEXT | | STEPS ARE TO CONTACT THE PROPERTY APPRAISERS AND | | REQUEST A UNIFIED PARCEL CONTROL NUMBER FOR THE UNITS. | | ONCE THIS IS DONE, PLEASE CONATCT ME [email protected] OR | | CALL 561-805-6659 TO BE ISSUED A SINGLE ADDRESS. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2021-09-13 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-09-13 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-09-13 |
Time |
17:17 |
Sent To |
|
|
Notes |
2021-09-13 17:17:32 | PREVIOUS COMMENTS NOT ADDRESSED: TWO UNITS ARE TO BE | | COMBINED 404 & 405 ARE TO BE COMBINED, YOU WILL NEED TO | | CONTACT VINCE NOEL [email protected] OR CALL 561-494-1040 | | TO START THE UNITY OF TITLE PROCEDURE. CURRENTLY THERE | | ARE TWO SEPARATE PCNS FOR THE TWO UNITS, A SINGLE PCN | | MUST BE ISSUED BY THE COUNTY. ONCE YOU HAVE RECEIVED | | THE SINGLE PCN AFTER DOING THE UNITY OF TITLE AND THEN | | CONTACTING THE PROPERTY APPRAISERS AND ISSUED A SINGLE | | PROPERTY CONTROL NUMBER (PCN) PLEASE CONTACT | | [email protected] OR CALL 561-805-6659 TO BE ISSUED AN | | ADDRESS. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2021-08-31 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-08-31 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-08-31 |
Time |
17:05 |
Sent To |
|
|
Notes |
2021-08-31 17:05:41 | TWO UNITS ARE TO BE COMBINED 404 & 405 ARE TO BE | | COMBINED, YOU WILL NEED TO CONTACT VINCE NOEL | | [email protected] OR CALL 561-494-1040 TO START THE UNITY | | OF TITLE PROCEDURE. CURRENTLY THERE ARE TWO SEPARATE | | PCNS FOR THE TWO UNITS, A SINGLE PCN MUST BE ISSUED BY | | THE COUNTY. ONCE YOU HAVE RECEIVED THE SINGLE PCN AFTER | | DOING THE UNITY OF TITLE AND THEN CONTACTING THE | | PROPERTY APPRAISERS AND ISSUED A SINGLE PROPERTY | | CONTROL NUMBER (PCN) PLEASE CONTACT [email protected] OR | | CALL 561-805-6659 TO BE ISSUED AN ADDRESS. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
4 |
Status |
P |
Date |
2021-11-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-02 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-02 |
Time |
14:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
F |
Date |
2021-10-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-22 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-22 |
Time |
10:21 |
Sent To |
|
|
Notes |
2021-10-22 10:22:26 | ASBESTOS LETTER ADDED TO PROJECTDOX NEEDS TO BE SIGNED | | BY THE CONTRACTOR - | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2021-09-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-09-23 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-09-23 |
Time |
08:45 |
Sent To |
|
|
Notes |
2021-09-23 08:46:06 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2021-08-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-11 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-08-11 |
Time |
13:03 |
Sent To |
|
|
Notes |
2021-08-11 15:11:09 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2021-11-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-22 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-22 |
Time |
11:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2021-11-03 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-02 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-02 |
Time |
16:49 |
Sent To |
|
|
Notes |
2021-11-03 13:27:54 | CONDO ALTERATION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | 1) NEED UNITY OF TITLE |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-22 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-22 |
Time |
10:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-09-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-09-22 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-09-22 |
Time |
15:23 |
Sent To |
|
|
Notes |
2021-09-22 15:31:52 | ALTERATION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | 1) PLEASE SHOW THE INTERIOR STOREFRONT GLAZING WHICH IS | | TO BE USED AS A GUARD RAIL (2ND FLOOR) TO BE LAMINATED | | FBC 1015.2.1 GLAZING. | | WHERE GLASS IS USED TO PROVIDE A GUARD OR AS A PORTION | | OF THE GUARD SYSTEM, THE GUARD SHALL COMPLY WITH | | SECTION 2407. WHERE THE GLAZING PROVIDED DOES NOT MEET | | THE STRENGTH AND ATTACHMENT REQUIREMENTS OF SECTION | | 1607.8, COMPLYING GUARDS SHALL BE LOCATED ALONG GLAZED | | SIDES OF OPEN-SIDED WALKING SURFACES. FBC 2407.1 | | MATERIALS. | | GLASS USED IN A HANDRAIL, GUARDRAIL OR GUARD SECTION | | SHALL BE LAMINATED GLASS CONSTRUCTED OF FULLY TEMPERED | | OR HEAT-STRENGTHENED GLASS AND SHALL COMPLY WITH | | CATEGORY II OR CPSC 16 CFR PART 1201 OR CLASS A OF ANSI | | Z97.1. | | | | 2) EXIT DOORS FOR OTHER UNITS HAVE BEEN REMOVED - TO | | ALLOW THE UNIT TO HAVE ONE EXIT DOOR PLEASE PROVIDE THE | | FOLLOWING INFORMATION - PLEASE SHOW THE EXIT ACCESS ( | | DISTANCE FROM THE MOST REMOTE PLACE IN THE UNIT TO THE | | UNIT EXIT DOOR) TRAVEL DISTANCE1017.3 MEASUREMENT. EXIT | | ACCESS TRAVEL DISTANCE SHALL BE MEASURED FROM THE MOST | | REMOTE POINT OF EACH ROOM, AREA OR SPACE ALONG THE | | NATURAL AND UNOBSTRUCTED PATH OF HORIZONTAL AND | | VERTICAL EGRESS TRAVEL TO THE ENTRANCE TO AN EXIT. - | | PLEASE SEE FBC TABLE 1006.2.1SPACES WITH ONE EXIT OR | | EXIT ACCESS DOORWAY | | | | 3) PLEASE SHOW THE MEZZANINE AREA TO COMPLY WITH FBC | | 505.2.1 OR SHOW THE 2ND FLOOR (5TH FLOOR) EXIT PER FBC | | TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO | | EXITS PER STORY | | | | 4TH FLOOR UNIT WILL REQUIRE THE FOLLOWING. | | THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED: | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.. | | PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING | | SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY | | DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP | | CEILING DESCRIPTION) | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP | | CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING | | ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED | | DROP CEILING DESCRIPTION) | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS | | ATTACHED TO THE FLOORING) | | | | 4). YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO | | VERIFY THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING | | TO PROJECTDOX ( [email protected] ) | | | | 5) A UNITY OF TITLE IS REQUIRED. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-08-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-11 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-08-11 |
Time |
13:03 |
Sent To |
|
|
Notes |
2021-08-11 15:13:00 | ALTERATION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | 1) PLEASE SHOW THE INTERIOR STOREFRONT GLAZING TO BE | | SAFETY GLAZING PER FBC 2406.4 | | 2) THE FLOOR PLANS AND THE LIFE SAFETY PLANS SHOW | | "GROUND FLOOR" AND "2ND FLOOR" - PLEASE CLEARIFY - IS | | THIS A GROUND FLOOR UNIT? OR 4TH FLOOR UNIT? | | | | 4TH FLOOR UNIT WILL REQUIRE THE FOLLOWING. | | THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED: | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.. | | PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING | | SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY | | DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP | | CEILING DESCRIPTION) | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP | | CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING | | ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED | | DROP CEILING DESCRIPTION) | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS | | ATTACHED TO THE FLOORING) | | | | 3). YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO | | VERIFY THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING | | TO PROJECTDOX ( [email protected] ) | | | | 4) A UNITY OF TITLE IS REQUIRED. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2021-11-20 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-11-20 |
Time |
19:46 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-11-20 |
Time |
18:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-10-05 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-10-05 |
Time |
21:34 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-10-05 |
Time |
20:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-08-09 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-08-09 |
Time |
22:29 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-08-09 |
Time |
20:33 |
Sent To |
|
|
Notes |
2021-08-09 22:29:23 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. SMOKE ALARMS SHOWN ON SEPARATE CIRCUITS. SMOKE | | ALARMS MUST BE TIED INTO LOCAL LIGHTING CIRCUIT PER FBC | | APENDIX J | | | | 2. PANEL B HAS 125AMP MAIN BREAKER WITH LOAD OF 128 | | AMPS. NEC 240 NEC 215 | | | | 3. PROVIDE CUT SHEETS FOR PRODUCT APPROVAL OF TANKLESS | | WATER HEATER. WATER HEATER SHOWN AS 4KW ONLY. NEC | | 110.3B NEC 220 | | | | 4. SMOKE ALARMS OUTSIDE BEDROOMS MUST BE SMOKE/CARBON | | COMBOS. FBC 314 AND 315. | | | | 5. AFCI PROTECTION REQUIRED PER NEC 210.12A 210.12B | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2021-11-04 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-11-04 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-11-04 |
Time |
09:45 |
Sent To |
|
|
Notes |
2021-11-04 09:45:51 | FIRE PROVISO: | | | | ANY WORK ON THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS, | | INCLUDING | | DEMO SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP | | DRAWINGS | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-10-15 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-10-15 |
Time |
11:52 |
Sent To |
|
|
Notes |
2021-10-15 11:52:55 | FIRE PROVISO: | | | | ANY WORK ON THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS, | | INCLUDING | | DEMO SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP | | DRAWINGS | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2021-07-30 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-07-30 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-07-30 |
Time |
13:37 |
Sent To |
|
|
Notes |
2021-07-30 13:39:01 | FIRE PROVISO: | | | | ANY WORK ON THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS, | | INCLUDING | | DEMO SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP | | DRAWINGS | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-11-20 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-11-20 |
Time |
19:46 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-11-01 |
Time |
08:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-10-26 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-10-14 |
Time |
06:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-10-05 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-10-05 |
Time |
21:34 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-09-13 |
Time |
16:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-08-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-11 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-07-28 |
Time |
16:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-11-05 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-11-05 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-11-05 |
Time |
09:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2021-08-10 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-10 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-10 |
Time |
08:23 |
Sent To |
|
|
Notes |
2021-08-10 08:23:42 | MECHANICAL SUB-PERMIT IS REQUIRED. ME |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2021-11-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-11-08 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-11-08 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2021-10-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-10-28 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-10-28 |
Time |
13:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2021-10-26 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-10-26 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-10-26 |
Time |
08:48 |
Sent To |
|
|
Notes |
2021-10-26 09:57:31 | 3RD REVIEW FBC-2020 PLUMBING | | PERMIT- 21071298 | | 10/26/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PALN REVIEW RESULTS: DENIED. | | | | 1) SHEET A2-01: SHOW THE REQUIRED 30X48 CLEAR FLOOR | | SPACE DIAGRAMS AND THE DOUBLE BOWL LAVATORY CABINET AND | | AT THE LAUNDRY APPLIANCES- PAGES 7.5 & 7.19 FAIR | | HOUSING DESIGN ACT MANUAL. | | | | 2) A2.01 & A8.03: BASED ON THE PLAN SHEET NOTE PLEASE | | PROVIDE THE REMOVABLE SINK CABINET DETAIL- PAGES 7.11 & | | 7.12 FAIR HOUSING DESIGN ACT MANUAL. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2021-09-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-09-27 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-09-27 |
Time |
08:41 |
Sent To |
|
|
Notes |
2021-09-27 10:03:01 | 2ND REVIEW FBC-2020 PLUMBING | | PERMIT- 21071298 | | 9/27/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. COMMENTS #1 & 6 FROM THE | | 1ST REVIEW PRINTED BELOW STILL EXISTS. PLEASE NOTE THAT | | SHEET A8.04 IS REFERENCED ON SHEET A2-01 FOR LOCATION | | OF ACCESSIBILITY ACCESSORY REINFORCEMENT?. | | | | 1) FAIR HOUSING ACT COMPLIANCE: PLEASE REFER TO PAGE 7 | | OF THE INTRODUCTION TO THE FAIR HOUSING DESIGN ACT | | MANUAL- IF THE CONDOMINIUMS AT 101 N. CLEMATIS (THE | | LOFT) WERE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH | | THE FAIR HOUSING ACT DESIGN GUIDELINES, THEN THE | | PROPOSED ALTERATIONS TO UNIT 405 SHALL ALSO BE IN | | COMPLIANCE WITH THE GUIDELINES. THE FAIR HOUSING | | ACCESSIBILITY GUIDELINES ARE INCLUDED IN THE FLORIDA | | ACCESSIBILITY CODE- 2020 7TH EDITION AND THE FAIR | | HOUSING DESIGN ACT MANUAL. IF APPLICABLE PLEASE INCLUDE | | THE FAIR HOUSING COMPLIANCE INFORMATION IN THE | | APPLICABLE CODE LIST ON G-01, AND REVISE THE PLANS IN | | ACCORDANCE WITH THE NOTES BELOW: | | A) THE DESIGN PROFESSIONAL OF RECORD SHALL INDICATE ON | | THE PLANS WHICH OF THE TWO BATHROOM TYPES IS THE BASIS | | OF DESIGN- SPECIFICATION TYPE A OR B ON THE PLANS. | | PLEASE REFER TO PAGES 7.34- 7.39 OF THE DESIGN MANUAL | | FOR EXPLANATORY INFORMATION ON SPECIFICATION A & B AND | | SHOW COMPLIANCE. | | B) REFER TO CHAPTER 7 (REQUIREMENT 7 USABLE KITCHENS & | | USABLE BATHROOMS) AND PROVIDE ENLARGED BATHROOM AND | | KITCHEN DRAWINGS AND DETAILS. THE SECTIONS LISTED BELOW | | MAY BE APPLICABLE BASED ON THE CHOSEN DESIGN | | SPECIFICATION. | | PAGES 7.1- 7.6 CLEAR FLOOR SPACES FOR SINKS AND | | APPLIANCES | | PAGES 7.7- 7.11 CLEARANCES BETWEEN KITCHEN COUNTERS AND | | ALL OPPOSING ELEMENTS. | | PAGES 7.12- 7.16 REMOVABLE SINK AND APPLIANCE CABINET | | DOORS INCLUDING KNEE SPACES. | | PAGES 7.40-7.46 WATER CLOSET CLEAR FLOOR SPACES. | | PAGES 7.47- 7.52: LAVATORY AND VANITY CLEAR FLOOR AND | | KNEE AND TOE CLEARANCES. | | PAGES 7.53- 7.55: BATHTUB CLEAR FLOOR SPACE AND CONTROL | | LOCATIONS | | C) REFER TO CHAPTER 6 (REINFORCED WALLS FOR GRAB BARS). | | BASED ON CHAPTER 7 COMPLIANCES LISTED ABOVE, PLEASE | | PROVIDE DRAWINGS AND DETAILS SHOWING GRAB BAR | | REINFORCEMENT LOCATIONS AND INSTALLATION DETAILS. | | PAGES 6.3- 6.8- WATER CLOSETS. | | PAGES 6.8- 6.11 BATHTUBS | | PAGES 6.14- 6.16 REINFORCEMENT METHODS. | | | | 6) FAILED. PLEASE NOTE THAT THE FIXTURE DRAIN FOR A | | WASHING MACHINE STANDPIPE SHALL CONNECT TO A 3-INCH OR | | LARGER DIAMETER BRANCH OR STACK- SECTION 406.2 FBC P. | | PLEASE LABEL THE 3-INCH FIXTURE DRAIN ON SHEET | | P-03/DETAIL-1. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-08-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-08-11 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-08-09 |
Time |
16:51 |
Sent To |
|
|
Notes |
2021-08-11 14:19:53 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 21071298 | | 8/11/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) FAIR HOUSING ACT COMPLIANCE: PLEASE REFER TO PAGE 7 | | OF THE INTRODUCTION TO THE FAIR HOUSING DESIGN ACT | | MANUAL- IF THE CONDOMINIUMS AT 101 N. CLEMATIS (THE | | LOFT) WERE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH | | THE FAIR HOUSING ACT DESIGN GUIDELINES, THEN THE | | PROPOSED ALTERATIONS TO UNIT 405 SHALL ALSO BE IN | | COMPLIANCE WITH THE GUIDELINES. THE FAIR HOUSING | | ACCESSIBILITY GUIDELINES ARE INCLUDED IN THE FLORIDA | | ACCESSIBILITY CODE- 2020 7TH EDITION AND THE FAIR | | HOUSING DESIGN ACT MANUAL. IF APPLICABLE PLEASE INCLUDE | | THE FAIR HOUSING COMPLIANCE INFORMATION IN THE | | APPLICABLE CODE LIST ON G-01, AND REVISE THE PLANS IN | | ACCORDANCE WITH THE NOTES BELOW: | | A) THE DESIGN PROFESSIONAL OF RECORD SHALL INDICATE ON | | THE PLANS WHICH OF THE TWO BATHROOM TYPES IS THE BASIS | | OF DESIGN- SPECIFICATION TYPE A OR B ON THE PLANS. | | PLEASE REFER TO PAGES 7.34- 7.39 OF THE DESIGN MANUAL | | FOR EXPLANATORY INFORMATION ON SPECIFICATION A & B AND | | SHOW COMPLIANCE. | | B) REFER TO CHAPTER 7 (REQUIREMENT 7 USABLE KITCHENS & | | USABLE BATHROOMS) AND PROVIDE ENLARGED BATHROOM AND | | KITCHEN DRAWINGS AND DETAILS. THE SECTIONS LISTED BELOW | | MAY BE APPLICABLE BASED ON THE CHOSEN DESIGN | | SPECIFICATION. | | PAGES 7.1- 7.6 CLEAR FLOOR SPACES FOR SINKS AND | | APPLIANCES | | PAGES 7.7- 7.11 CLEARANCES BETWEEN KITCHEN COUNTERS AND | | ALL OPPOSING ELEMENTS. | | PAGES 7.12- 7.16 REMOVABLE SINK AND APPLIANCE CABINET | | DOORS INCLUDING KNEE SPACES. | | PAGES 7.40-7.46 WATER CLOSET CLEAR FLOOR SPACES. | | PAGES 7.47- 7.52: LAVATORY AND VANITY CLEAR FLOOR AND | | KNEE AND TOE CLEARANCES. | | PAGES 7.53- 7.55: BATHTUB CLEAR FLOOR SPACE AND CONTROL | | LOCATIONS | | C) REFER TO CHAPTER 6 (REINFORCED WALLS FOR GRAB BARS). | | BASED ON CHAPTER 7 COMPLIANCES LISTED ABOVE, PLEASE | | PROVIDE DRAWINGS AND DETAILS SHOWING GRAB BAR | | REINFORCEMENT LOCATIONS AND INSTALLATION DETAILS. | | PAGES 6.3- 6.8- WATER CLOSETS. | | PAGES 6.8- 6.11 BATHTUBS | | PAGES 6.14- 6.16 REINFORCEMENT METHODS. | | | | 2) SHEETS P0.1 & P0.2: PLEASE SHOW THE NEW WATER HEATER | | LOCATION- SECTION 502.1 FBC P. | | | | 3) P0.2 & A2.01: THE RISERS ARE LABELED AS SECTION A ON | | P0.2. PLEASE SHOW THE LOCATION OF SECTION A ON A2.01 OR | | PROVIDE A PLUMBING FLOOR PLAN SHOWING THE SECTION | | LOCATIONS- SECTION 107.2.1 WPB. | | | | A) P0.2, P0.3, P.04 & A2.01: THE FIXTURE LABELS IN THE | | ISOMETRICS DO NOT MATCH THE FIXTURE LABELS IN THE | | SCHEDULE I.E. (P6) IS CALLED OUT AS A TOILET IN THE | | SCHEDULE- SECTION 107.2.1 WPB. IS THERE A DIFFERENT | | FIXTURE SCHEDULE THAT CORRELATES WITH THE LABELS IN THE | | ISOMETRICS? PLEASE NOTE THAT MANY OF THE FIXTURE IN THE | | SCHEDULE HAVE A & B DESIGNATIONS. A COMPLETE REVIEW OF | | THE ISOMETRICS CANNOT BE ACCOMPLISHED AT THIS TIME. | | | | 4) P0.3 & A9.01: THE RISERS ARE LABELED AS SECTION B, C | | & D ON P.03. PLEASE SHOW THE LOCATIONS OF THE SECTIONS | | ON A2.01 OR PROVIDE A SEPARATE PLUMBING FLOOR PLAN | | SHOWING THE SECTION LOCATIONS- SECTION 107.2.1 WPB. | | | | 5) P0.4 & A9.01: THE RISERS ARE LABELED AS SECTION E1 & | | E2 ON P.03. PLEASE SHOW THE LOCATIONS OF THE SECTIONS | | ON A2.01 OR PROVIDE A SEPARATE PLUMBING FLOOR PLAN | | SHOWING THE SECTION LOCATIONS- SECTION 107.2.1 WPB. IT | | APPEARS THAT P11 IN SECTION E2 IS NOT BEING VENTED | | BECAUSE THE VENT APPEARS TO BE AT THE CLEANOUT | | LOCATION- SECTION 901.2.1 & 910.1 FBC P. | | | | 6) PLEASE NOTE THAT THE FIXTURE DRAIN FOR A WASHING | | MACHINE STANDPIPE SHALL CONNECT TO A 3-INCH OR LARGER | | DIAMETER BRANCH OR STACK- SECTION 406.2 FBC P. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-11-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-02 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-02 |
Time |
16:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2021-10-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-22 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-22 |
Time |
11:03 |
Sent To |
|
|
Notes |
2021-10-22 11:02:57 | SIGNATURE REVIEW | | | | THE FOLLOWING DRAWINGS AS LABELED IN PROJECTDOX NEED TO | | BE SIGNED AND SEALED BY THE DESIGNER FBC WPB 107.1 | | | | 003-LS-01 EXITING LIFE SAFETY FLOOR PLANS.PDF | | 006-A3-01 REFLECTED CEILING PLAN.PDF | | 007-A7-01 INTERIOR ELEVATION.PDF | | 008-A8-01 LIFE SAFETY DETAILS.PDF | | 009-A8-02 DETAILS.PDF | | 010-A9-01 SCHEDULES.PDF | | 011-M-01 PROPOSED MECHANICAL PLAN.PDF | | 018-S-01 PROPOSED STRUCTURAL PLANS.PDF | | 019-S-02 STAIR SECTIONS AND STRUCTURAL DETAILS.PDF | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | DIVISION AT THE CITY HALL. | | | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-09-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-09-23 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-09-23 |
Time |
08:48 |
Sent To |
|
|
Notes |
2021-09-23 08:51:24 | SIGNATURE REVIEW | | | | THE FOLLOWING DRAWINGS AS LABELED IN PROJECTDOX NEED TO | | BE SIGNED AND SEALED BY THE DESIGNER FBC WPB 107.1 | | 003-LS-01 EXITING LIFE SAFETY FLOOR PLANS.PDF | | 004-LS-02 PROPOSED LIFE SAFETY FLOOR PLANS.PDF | | 006-A3-01 REFLECTED CEILING PLAN.PDF | | 007-A7-01 INTERIOR ELEVATION.PDF | | 008-A8-01 LIFE SAFETY DETAILS.PDF | | 009-A8-02 DETAILS.PDF | | 010-A9-01 SCHEDULES.PDF | | 011-M-01 PROPOSED MECHANICAL PLAN.PDF | | 018-S-01 PROPOSED STRUCTURAL PLANS.PDF | | 019-S-02 STAIR SECTIONS AND STRUCTURAL DETAILS.PDF | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | DIVISION AT THE CITY HALL. | | | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-08-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-08-11 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-08-11 |
Time |
15:20 |
Sent To |
|
|
Notes |
2021-08-11 15:23:40 | SIGNATURE REVIEW | | | | DRAWINGS NEED TO BE SIGNED BY THE DESIGNER FBC WPB | | 107.1 | | | | DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER | | OR ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR | | - IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN | | ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL. | | |
|
|