Plan Review Details - Permit 21071298
Plan Review Stops For Permit 21071298
Review Stop AD ADDRESSING
Rev No 5 Status P Date 2021-11-22 Cont ID  
Sent By cpuell Date 2021-11-22 Time 13:50 Rev Time 0.00
Received By cpuell Date 2021-11-22 Time 13:50 Sent To  
Notes
2021-11-22 13:53:24PARCEL MERGED PCN 74434322360044040 AND
 74434322360044050 TO CREATE A SINGLE PCN
 74434322360044040, UNIT 404 WILL BE RETIRED AND UNIT
 405 WILL REMAIN AS THE SOLE UNIT NUMBER FOR THE MERGED
 PARCEL..

Review Stop AD ADDRESSING
Rev No 4 Status F Date 2021-11-01 Cont ID  
Sent By cpuell Date 2021-11-01 Time 09:56 Rev Time 0.00
Received By cpuell Date 2021-11-01 Time 09:56 Sent To  
Notes
2021-11-01 09:56:49THANK YOU FOR UPLOADING THE UNITY OF TITLE, YOU NEXT
 STEPS ARE TO CONTACT THE PROPERTY APPRAISERS AND
 REQUEST A UNIFIED PARCEL CONTROL NUMBER FOR THE UNITS.
 ONCE THIS IS DONE, PLEASE CONATCT ME [email protected] OR
 CALL 561-805-6659 TO BE ISSUED A SINGLE ADDRESS.

Review Stop AD ADDRESSING
Rev No 3 Status F Date 2021-10-14 Cont ID  
Sent By cpuell Date 2021-10-14 Time 09:04 Rev Time 0.00
Received By cpuell Date 2021-10-14 Time 09:04 Sent To  
Notes
2021-10-14 09:05:56THANK YOU FOR UPLOADING THE UNITY OF TITLE, YOU NEXT
 STEPS ARE TO CONTACT THE PROPERTY APPRAISERS AND
 REQUEST A UNIFIED PARCEL CONTROL NUMBER FOR THE UNITS.
 ONCE THIS IS DONE, PLEASE CONATCT ME [email protected] OR
 CALL 561-805-6659 TO BE ISSUED A SINGLE ADDRESS.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2021-09-13 Cont ID  
Sent By cpuell Date 2021-09-13 Time 17:17 Rev Time 0.00
Received By cpuell Date 2021-09-13 Time 17:17 Sent To  
Notes
2021-09-13 17:17:32PREVIOUS COMMENTS NOT ADDRESSED: TWO UNITS ARE TO BE
 COMBINED 404 & 405 ARE TO BE COMBINED, YOU WILL NEED TO
 CONTACT VINCE NOEL [email protected] OR CALL 561-494-1040
 TO START THE UNITY OF TITLE PROCEDURE. CURRENTLY THERE
 ARE TWO SEPARATE PCNS FOR THE TWO UNITS, A SINGLE PCN
 MUST BE ISSUED BY THE COUNTY. ONCE YOU HAVE RECEIVED
 THE SINGLE PCN AFTER DOING THE UNITY OF TITLE AND THEN
 CONTACTING THE PROPERTY APPRAISERS AND ISSUED A SINGLE
 PROPERTY CONTROL NUMBER (PCN) PLEASE CONTACT
 [email protected] OR CALL 561-805-6659 TO BE ISSUED AN
 ADDRESS.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-08-31 Cont ID  
Sent By cpuell Date 2021-08-31 Time 17:05 Rev Time 0.00
Received By cpuell Date 2021-08-31 Time 17:05 Sent To  
Notes
2021-08-31 17:05:41TWO UNITS ARE TO BE COMBINED 404 & 405 ARE TO BE
 COMBINED, YOU WILL NEED TO CONTACT VINCE NOEL
 [email protected] OR CALL 561-494-1040 TO START THE UNITY
 OF TITLE PROCEDURE. CURRENTLY THERE ARE TWO SEPARATE
 PCNS FOR THE TWO UNITS, A SINGLE PCN MUST BE ISSUED BY
 THE COUNTY. ONCE YOU HAVE RECEIVED THE SINGLE PCN AFTER
 DOING THE UNITY OF TITLE AND THEN CONTACTING THE
 PROPERTY APPRAISERS AND ISSUED A SINGLE PROPERTY
 CONTROL NUMBER (PCN) PLEASE CONTACT [email protected] OR
 CALL 561-805-6659 TO BE ISSUED AN ADDRESS.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 4 Status P Date 2021-11-02 Cont ID  
Sent By rmcphers Date 2021-11-02 Time 14:26 Rev Time 0.00
Received By rmcphers Date 2021-11-02 Time 14:26 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status F Date 2021-10-22 Cont ID  
Sent By rmcphers Date 2021-10-22 Time 10:21 Rev Time 0.00
Received By rmcphers Date 2021-10-22 Time 10:21 Sent To  
Notes
2021-10-22 10:22:26ASBESTOS LETTER ADDED TO PROJECTDOX NEEDS TO BE SIGNED
 BY THE CONTRACTOR -
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-09-23 Cont ID  
Sent By rmcphers Date 2021-09-23 Time 08:45 Rev Time 0.00
Received By rmcphers Date 2021-09-23 Time 08:45 Sent To  
Notes
2021-09-23 08:46:06PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-08-11 Cont ID  
Sent By rmcphers Date 2021-08-11 Time 14:32 Rev Time 0.00
Received By rmcphers Date 2021-08-11 Time 13:03 Sent To  
Notes
2021-08-11 15:11:09PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2021-11-22 Cont ID  
Sent By rmcphers Date 2021-11-22 Time 11:39 Rev Time 0.00
Received By rmcphers Date 2021-11-22 Time 11:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2021-11-03 Cont ID  
Sent By rmcphers Date 2021-11-02 Time 16:49 Rev Time 0.00
Received By rmcphers Date 2021-11-02 Time 16:49 Sent To  
Notes
2021-11-03 13:27:54CONDO ALTERATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) NEED UNITY OF TITLE

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-10-22 Cont ID  
Sent By rmcphers Date 2021-10-22 Time 10:45 Rev Time 0.00
Received By rmcphers Date 2021-10-22 Time 10:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-09-22 Cont ID  
Sent By rmcphers Date 2021-09-22 Time 15:52 Rev Time 0.00
Received By rmcphers Date 2021-09-22 Time 15:23 Sent To  
Notes
2021-09-22 15:31:52ALTERATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) PLEASE SHOW THE INTERIOR STOREFRONT GLAZING WHICH IS
 TO BE USED AS A GUARD RAIL (2ND FLOOR) TO BE LAMINATED
 FBC 1015.2.1 GLAZING.
 WHERE GLASS IS USED TO PROVIDE A GUARD OR AS A PORTION
 OF THE GUARD SYSTEM, THE GUARD SHALL COMPLY WITH
 SECTION 2407. WHERE THE GLAZING PROVIDED DOES NOT MEET
 THE STRENGTH AND ATTACHMENT REQUIREMENTS OF SECTION
 1607.8, COMPLYING GUARDS SHALL BE LOCATED ALONG GLAZED
 SIDES OF OPEN-SIDED WALKING SURFACES. FBC 2407.1
 MATERIALS.
 GLASS USED IN A HANDRAIL, GUARDRAIL OR GUARD SECTION
 SHALL BE LAMINATED GLASS CONSTRUCTED OF FULLY TEMPERED
 OR HEAT-STRENGTHENED GLASS AND SHALL COMPLY WITH
 CATEGORY II OR CPSC 16 CFR PART 1201 OR CLASS A OF ANSI
 Z97.1.
  
 2) EXIT DOORS FOR OTHER UNITS HAVE BEEN REMOVED - TO
 ALLOW THE UNIT TO HAVE ONE EXIT DOOR PLEASE PROVIDE THE
 FOLLOWING INFORMATION - PLEASE SHOW THE EXIT ACCESS (
 DISTANCE FROM THE MOST REMOTE PLACE IN THE UNIT TO THE
 UNIT EXIT DOOR) TRAVEL DISTANCE1017.3 MEASUREMENT. EXIT
 ACCESS TRAVEL DISTANCE SHALL BE MEASURED FROM THE MOST
 REMOTE POINT OF EACH ROOM, AREA OR SPACE ALONG THE
 NATURAL AND UNOBSTRUCTED PATH OF HORIZONTAL AND
 VERTICAL EGRESS TRAVEL TO THE ENTRANCE TO AN EXIT. -
 PLEASE SEE FBC TABLE 1006.2.1SPACES WITH ONE EXIT OR
 EXIT ACCESS DOORWAY
  
 3) PLEASE SHOW THE MEZZANINE AREA TO COMPLY WITH FBC
 505.2.1 OR SHOW THE 2ND FLOOR (5TH FLOOR) EXIT PER FBC
 TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO
 EXITS PER STORY
  
 4TH FLOOR UNIT WILL REQUIRE THE FOLLOWING.
 THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 4). YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO
 VERIFY THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING
 TO PROJECTDOX ( [email protected] )
  
 5) A UNITY OF TITLE IS REQUIRED.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-08-11 Cont ID  
Sent By rmcphers Date 2021-08-11 Time 15:14 Rev Time 0.00
Received By rmcphers Date 2021-08-11 Time 13:03 Sent To  
Notes
2021-08-11 15:13:00ALTERATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) PLEASE SHOW THE INTERIOR STOREFRONT GLAZING TO BE
 SAFETY GLAZING PER FBC 2406.4
 2) THE FLOOR PLANS AND THE LIFE SAFETY PLANS SHOW
 "GROUND FLOOR" AND "2ND FLOOR" - PLEASE CLEARIFY - IS
 THIS A GROUND FLOOR UNIT? OR 4TH FLOOR UNIT?
  
 4TH FLOOR UNIT WILL REQUIRE THE FOLLOWING.
 THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 3). YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO
 VERIFY THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING
 TO PROJECTDOX ( [email protected] )
  
 4) A UNITY OF TITLE IS REQUIRED.
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-11-20 Cont ID  
Sent By fgiaquin Date 2021-11-20 Time 19:46 Rev Time 0.00
Received By fgiaquin Date 2021-11-20 Time 18:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-10-05 Cont ID  
Sent By fgiaquin Date 2021-10-05 Time 21:34 Rev Time 0.00
Received By fgiaquin Date 2021-10-05 Time 20:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-08-09 Cont ID  
Sent By fgiaquin Date 2021-08-09 Time 22:29 Rev Time 0.00
Received By fgiaquin Date 2021-08-09 Time 20:33 Sent To  
Notes
2021-08-09 22:29:23ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. SMOKE ALARMS SHOWN ON SEPARATE CIRCUITS. SMOKE
 ALARMS MUST BE TIED INTO LOCAL LIGHTING CIRCUIT PER FBC
 APENDIX J
  
 2. PANEL B HAS 125AMP MAIN BREAKER WITH LOAD OF 128
 AMPS. NEC 240 NEC 215
  
 3. PROVIDE CUT SHEETS FOR PRODUCT APPROVAL OF TANKLESS
 WATER HEATER. WATER HEATER SHOWN AS 4KW ONLY. NEC
 110.3B NEC 220
  
 4. SMOKE ALARMS OUTSIDE BEDROOMS MUST BE SMOKE/CARBON
 COMBOS. FBC 314 AND 315.
  
 5. AFCI PROTECTION REQUIRED PER NEC 210.12A 210.12B
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-11-04 Cont ID  
Sent By pleduc Date 2021-11-04 Time   Rev Time 0.00
Received By pleduc Date 2021-11-04 Time 09:45 Sent To  
Notes
2021-11-04 09:45:51FIRE PROVISO:
  
 ANY WORK ON THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS,
 INCLUDING
 DEMO SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-10-15 Cont ID  
Sent By pleduc Date 2021-10-15 Time   Rev Time 0.00
Received By pleduc Date 2021-10-15 Time 11:52 Sent To  
Notes
2021-10-15 11:52:55FIRE PROVISO:
  
 ANY WORK ON THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS,
 INCLUDING
 DEMO SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-07-30 Cont ID  
Sent By pleduc Date 2021-07-30 Time   Rev Time 0.00
Received By pleduc Date 2021-07-30 Time 13:37 Sent To  
Notes
2021-07-30 13:39:01FIRE PROVISO:
  
 ANY WORK ON THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS,
 INCLUDING
 DEMO SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-11-20 Cont ID  
Sent By fgiaquin Date 2021-11-20 Time 19:46 Rev Time 0.00
Received By fgiaquin Date 2021-11-01 Time 08:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2021-10-26 Time   Rev Time 0.00
Received By aoliver Date 2021-10-14 Time 06:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-05 Cont ID  
Sent By fgiaquin Date 2021-10-05 Time 21:34 Rev Time 0.00
Received By fgiaquin Date 2021-09-13 Time 16:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-08-11 Cont ID  
Sent By rmcphers Date 2021-08-11 Time 15:25 Rev Time 0.00
Received By rmcphers Date 2021-07-28 Time 16:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-11-05 Cont ID  
Sent By medwards Date 2021-11-05 Time 09:01 Rev Time 0.00
Received By medwards Date 2021-11-05 Time 09:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-08-10 Cont ID  
Sent By medwards Date 2021-08-10 Time 08:23 Rev Time 0.00
Received By medwards Date 2021-08-10 Time 08:23 Sent To  
Notes
2021-08-10 08:23:42MECHANICAL SUB-PERMIT IS REQUIRED. ME

Review Stop P PLUMBING
Rev No 5 Status P Date 2021-11-08 Cont ID  
Sent By ccole Date 2021-11-08 Time 15:54 Rev Time 0.00
Received By ccole Date 2021-11-08 Time 15:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2021-10-28 Cont ID  
Sent By ccole Date 2021-10-28 Time 13:12 Rev Time 0.00
Received By ccole Date 2021-10-28 Time 13:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2021-10-26 Cont ID  
Sent By ccole Date 2021-10-26 Time 09:56 Rev Time 0.00
Received By ccole Date 2021-10-26 Time 08:48 Sent To  
Notes
2021-10-26 09:57:313RD REVIEW FBC-2020 PLUMBING
 PERMIT- 21071298
 10/26/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PALN REVIEW RESULTS: DENIED.
  
 1) SHEET A2-01: SHOW THE REQUIRED 30X48 CLEAR FLOOR
 SPACE DIAGRAMS AND THE DOUBLE BOWL LAVATORY CABINET AND
 AT THE LAUNDRY APPLIANCES- PAGES 7.5 & 7.19 FAIR
 HOUSING DESIGN ACT MANUAL.
  
 2) A2.01 & A8.03: BASED ON THE PLAN SHEET NOTE PLEASE
 PROVIDE THE REMOVABLE SINK CABINET DETAIL- PAGES 7.11 &
 7.12 FAIR HOUSING DESIGN ACT MANUAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-09-27 Cont ID  
Sent By ccole Date 2021-09-27 Time 10:02 Rev Time 0.00
Received By ccole Date 2021-09-27 Time 08:41 Sent To  
Notes
2021-09-27 10:03:012ND REVIEW FBC-2020 PLUMBING
 PERMIT- 21071298
 9/27/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. COMMENTS #1 & 6 FROM THE
 1ST REVIEW PRINTED BELOW STILL EXISTS. PLEASE NOTE THAT
 SHEET A8.04 IS REFERENCED ON SHEET A2-01 FOR LOCATION
 OF ACCESSIBILITY ACCESSORY REINFORCEMENT?.
  
 1) FAIR HOUSING ACT COMPLIANCE: PLEASE REFER TO PAGE 7
 OF THE INTRODUCTION TO THE FAIR HOUSING DESIGN ACT
 MANUAL- IF THE CONDOMINIUMS AT 101 N. CLEMATIS (THE
 LOFT) WERE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH
 THE FAIR HOUSING ACT DESIGN GUIDELINES, THEN THE
 PROPOSED ALTERATIONS TO UNIT 405 SHALL ALSO BE IN
 COMPLIANCE WITH THE GUIDELINES. THE FAIR HOUSING
 ACCESSIBILITY GUIDELINES ARE INCLUDED IN THE FLORIDA
 ACCESSIBILITY CODE- 2020 7TH EDITION AND THE FAIR
 HOUSING DESIGN ACT MANUAL. IF APPLICABLE PLEASE INCLUDE
 THE FAIR HOUSING COMPLIANCE INFORMATION IN THE
 APPLICABLE CODE LIST ON G-01, AND REVISE THE PLANS IN
 ACCORDANCE WITH THE NOTES BELOW:
 A) THE DESIGN PROFESSIONAL OF RECORD SHALL INDICATE ON
 THE PLANS WHICH OF THE TWO BATHROOM TYPES IS THE BASIS
 OF DESIGN- SPECIFICATION TYPE A OR B ON THE PLANS.
 PLEASE REFER TO PAGES 7.34- 7.39 OF THE DESIGN MANUAL
 FOR EXPLANATORY INFORMATION ON SPECIFICATION A & B AND
 SHOW COMPLIANCE.
 B) REFER TO CHAPTER 7 (REQUIREMENT 7 USABLE KITCHENS &
 USABLE BATHROOMS) AND PROVIDE ENLARGED BATHROOM AND
 KITCHEN DRAWINGS AND DETAILS. THE SECTIONS LISTED BELOW
 MAY BE APPLICABLE BASED ON THE CHOSEN DESIGN
 SPECIFICATION.
 PAGES 7.1- 7.6 CLEAR FLOOR SPACES FOR SINKS AND
 APPLIANCES
 PAGES 7.7- 7.11 CLEARANCES BETWEEN KITCHEN COUNTERS AND
 ALL OPPOSING ELEMENTS.
 PAGES 7.12- 7.16 REMOVABLE SINK AND APPLIANCE CABINET
 DOORS INCLUDING KNEE SPACES.
 PAGES 7.40-7.46 WATER CLOSET CLEAR FLOOR SPACES.
 PAGES 7.47- 7.52: LAVATORY AND VANITY CLEAR FLOOR AND
 KNEE AND TOE CLEARANCES.
 PAGES 7.53- 7.55: BATHTUB CLEAR FLOOR SPACE AND CONTROL
 LOCATIONS
 C) REFER TO CHAPTER 6 (REINFORCED WALLS FOR GRAB BARS).
 BASED ON CHAPTER 7 COMPLIANCES LISTED ABOVE, PLEASE
 PROVIDE DRAWINGS AND DETAILS SHOWING GRAB BAR
 REINFORCEMENT LOCATIONS AND INSTALLATION DETAILS.
 PAGES 6.3- 6.8- WATER CLOSETS.
 PAGES 6.8- 6.11 BATHTUBS
 PAGES 6.14- 6.16 REINFORCEMENT METHODS.
  
 6) FAILED. PLEASE NOTE THAT THE FIXTURE DRAIN FOR A
 WASHING MACHINE STANDPIPE SHALL CONNECT TO A 3-INCH OR
 LARGER DIAMETER BRANCH OR STACK- SECTION 406.2 FBC P.
 PLEASE LABEL THE 3-INCH FIXTURE DRAIN ON SHEET
 P-03/DETAIL-1.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-08-11 Cont ID  
Sent By ccole Date 2021-08-11 Time 14:19 Rev Time 0.00
Received By ccole Date 2021-08-09 Time 16:51 Sent To  
Notes
2021-08-11 14:19:531ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21071298
 8/11/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) FAIR HOUSING ACT COMPLIANCE: PLEASE REFER TO PAGE 7
 OF THE INTRODUCTION TO THE FAIR HOUSING DESIGN ACT
 MANUAL- IF THE CONDOMINIUMS AT 101 N. CLEMATIS (THE
 LOFT) WERE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH
 THE FAIR HOUSING ACT DESIGN GUIDELINES, THEN THE
 PROPOSED ALTERATIONS TO UNIT 405 SHALL ALSO BE IN
 COMPLIANCE WITH THE GUIDELINES. THE FAIR HOUSING
 ACCESSIBILITY GUIDELINES ARE INCLUDED IN THE FLORIDA
 ACCESSIBILITY CODE- 2020 7TH EDITION AND THE FAIR
 HOUSING DESIGN ACT MANUAL. IF APPLICABLE PLEASE INCLUDE
 THE FAIR HOUSING COMPLIANCE INFORMATION IN THE
 APPLICABLE CODE LIST ON G-01, AND REVISE THE PLANS IN
 ACCORDANCE WITH THE NOTES BELOW:
 A) THE DESIGN PROFESSIONAL OF RECORD SHALL INDICATE ON
 THE PLANS WHICH OF THE TWO BATHROOM TYPES IS THE BASIS
 OF DESIGN- SPECIFICATION TYPE A OR B ON THE PLANS.
 PLEASE REFER TO PAGES 7.34- 7.39 OF THE DESIGN MANUAL
 FOR EXPLANATORY INFORMATION ON SPECIFICATION A & B AND
 SHOW COMPLIANCE.
 B) REFER TO CHAPTER 7 (REQUIREMENT 7 USABLE KITCHENS &
 USABLE BATHROOMS) AND PROVIDE ENLARGED BATHROOM AND
 KITCHEN DRAWINGS AND DETAILS. THE SECTIONS LISTED BELOW
 MAY BE APPLICABLE BASED ON THE CHOSEN DESIGN
 SPECIFICATION.
 PAGES 7.1- 7.6 CLEAR FLOOR SPACES FOR SINKS AND
 APPLIANCES
 PAGES 7.7- 7.11 CLEARANCES BETWEEN KITCHEN COUNTERS AND
 ALL OPPOSING ELEMENTS.
 PAGES 7.12- 7.16 REMOVABLE SINK AND APPLIANCE CABINET
 DOORS INCLUDING KNEE SPACES.
 PAGES 7.40-7.46 WATER CLOSET CLEAR FLOOR SPACES.
 PAGES 7.47- 7.52: LAVATORY AND VANITY CLEAR FLOOR AND
 KNEE AND TOE CLEARANCES.
 PAGES 7.53- 7.55: BATHTUB CLEAR FLOOR SPACE AND CONTROL
 LOCATIONS
 C) REFER TO CHAPTER 6 (REINFORCED WALLS FOR GRAB BARS).
 BASED ON CHAPTER 7 COMPLIANCES LISTED ABOVE, PLEASE
 PROVIDE DRAWINGS AND DETAILS SHOWING GRAB BAR
 REINFORCEMENT LOCATIONS AND INSTALLATION DETAILS.
 PAGES 6.3- 6.8- WATER CLOSETS.
 PAGES 6.8- 6.11 BATHTUBS
 PAGES 6.14- 6.16 REINFORCEMENT METHODS.
  
 2) SHEETS P0.1 & P0.2: PLEASE SHOW THE NEW WATER HEATER
 LOCATION- SECTION 502.1 FBC P.
  
 3) P0.2 & A2.01: THE RISERS ARE LABELED AS SECTION A ON
 P0.2. PLEASE SHOW THE LOCATION OF SECTION A ON A2.01 OR
 PROVIDE A PLUMBING FLOOR PLAN SHOWING THE SECTION
 LOCATIONS- SECTION 107.2.1 WPB.
  
 A) P0.2, P0.3, P.04 & A2.01: THE FIXTURE LABELS IN THE
 ISOMETRICS DO NOT MATCH THE FIXTURE LABELS IN THE
 SCHEDULE I.E. (P6) IS CALLED OUT AS A TOILET IN THE
 SCHEDULE- SECTION 107.2.1 WPB. IS THERE A DIFFERENT
 FIXTURE SCHEDULE THAT CORRELATES WITH THE LABELS IN THE
 ISOMETRICS? PLEASE NOTE THAT MANY OF THE FIXTURE IN THE
 SCHEDULE HAVE A & B DESIGNATIONS. A COMPLETE REVIEW OF
 THE ISOMETRICS CANNOT BE ACCOMPLISHED AT THIS TIME.
  
 4) P0.3 & A9.01: THE RISERS ARE LABELED AS SECTION B, C
 & D ON P.03. PLEASE SHOW THE LOCATIONS OF THE SECTIONS
 ON A2.01 OR PROVIDE A SEPARATE PLUMBING FLOOR PLAN
 SHOWING THE SECTION LOCATIONS- SECTION 107.2.1 WPB.
  
 5) P0.4 & A9.01: THE RISERS ARE LABELED AS SECTION E1 &
 E2 ON P.03. PLEASE SHOW THE LOCATIONS OF THE SECTIONS
 ON A2.01 OR PROVIDE A SEPARATE PLUMBING FLOOR PLAN
 SHOWING THE SECTION LOCATIONS- SECTION 107.2.1 WPB. IT
 APPEARS THAT P11 IN SECTION E2 IS NOT BEING VENTED
 BECAUSE THE VENT APPEARS TO BE AT THE CLEANOUT
 LOCATION- SECTION 901.2.1 & 910.1 FBC P.
  
 6) PLEASE NOTE THAT THE FIXTURE DRAIN FOR A WASHING
 MACHINE STANDPIPE SHALL CONNECT TO A 3-INCH OR LARGER
 DIAMETER BRANCH OR STACK- SECTION 406.2 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-11-02 Cont ID  
Sent By rmcphers Date 2021-11-02 Time 16:49 Rev Time 0.00
Received By rmcphers Date 2021-11-02 Time 16:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-10-22 Cont ID  
Sent By rmcphers Date 2021-10-22 Time 11:03 Rev Time 0.00
Received By rmcphers Date 2021-10-22 Time 11:03 Sent To  
Notes
2021-10-22 11:02:57SIGNATURE REVIEW
  
 THE FOLLOWING DRAWINGS AS LABELED IN PROJECTDOX NEED TO
 BE SIGNED AND SEALED BY THE DESIGNER FBC WPB 107.1
  
 003-LS-01 EXITING LIFE SAFETY FLOOR PLANS.PDF
 006-A3-01 REFLECTED CEILING PLAN.PDF
 007-A7-01 INTERIOR ELEVATION.PDF
 008-A8-01 LIFE SAFETY DETAILS.PDF
 009-A8-02 DETAILS.PDF
 010-A9-01 SCHEDULES.PDF
 011-M-01 PROPOSED MECHANICAL PLAN.PDF
 018-S-01 PROPOSED STRUCTURAL PLANS.PDF
 019-S-02 STAIR SECTIONS AND STRUCTURAL DETAILS.PDF
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-09-23 Cont ID  
Sent By rmcphers Date 2021-09-23 Time 08:48 Rev Time 0.00
Received By rmcphers Date 2021-09-23 Time 08:48 Sent To  
Notes
2021-09-23 08:51:24SIGNATURE REVIEW
  
 THE FOLLOWING DRAWINGS AS LABELED IN PROJECTDOX NEED TO
 BE SIGNED AND SEALED BY THE DESIGNER FBC WPB 107.1
 003-LS-01 EXITING LIFE SAFETY FLOOR PLANS.PDF
 004-LS-02 PROPOSED LIFE SAFETY FLOOR PLANS.PDF
 006-A3-01 REFLECTED CEILING PLAN.PDF
 007-A7-01 INTERIOR ELEVATION.PDF
 008-A8-01 LIFE SAFETY DETAILS.PDF
 009-A8-02 DETAILS.PDF
 010-A9-01 SCHEDULES.PDF
 011-M-01 PROPOSED MECHANICAL PLAN.PDF
 018-S-01 PROPOSED STRUCTURAL PLANS.PDF
 019-S-02 STAIR SECTIONS AND STRUCTURAL DETAILS.PDF
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-08-11 Cont ID  
Sent By rmcphers Date 2021-08-11 Time 15:21 Rev Time 0.00
Received By rmcphers Date 2021-08-11 Time 15:20 Sent To  
Notes
2021-08-11 15:23:40SIGNATURE REVIEW
  
 DRAWINGS NEED TO BE SIGNED BY THE DESIGNER FBC WPB
 107.1
  
 DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE
 READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED
 TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER
 OR ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR
 - IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN
 ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE
 FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL.
  