Plan Review Details - Permit 21071163
Plan Review Stops For Permit 21071163
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-08-16 Cont ID  
Sent By cthroop Date 2021-08-16 Time 17:42 Rev Time 0.00
Received By cthroop Date 2021-08-14 Time 08:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-08-04 Cont ID  
Sent By fgiaquin Date 2021-08-04 Time 20:48 Rev Time 0.00
Received By fgiaquin Date 2021-08-02 Time 22:34 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-08-26 Cont ID  
Sent By lcrespo Date 2021-08-26 Time 16:51 Rev Time 0.00
Received By lcrespo Date 2021-08-26 Time 16:51 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-08-04 Cont ID  
Sent By lcrespo Date 2021-08-04 Time 10:01 Rev Time 0.00
Received By lcrespo Date 2021-08-03 Time 12:48 Sent To  
Notes
2021-08-04 10:00:5608/04/21 1ST GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
 1. THE EXISTING SYSTEM HAS 97 FEET TO THE LONGEST RUN
 IN CITY RECORDS. IN THE ISOMETRIC SUBMITTED, THERE ARE
 20 FEET OF 3/4 INCHES GALVANIZED AND AN EXISTING OF 85
 FEET ON A TEE; IT HAS A TOTAL OF 105 FEET. THE 20 FEET
 3/4 INCH TO THE METER WHICH HAS A 12-INCH WATER COLUMN
 MARKED ON IT. IF THIS IS A 2 PSI METER UPGRADE, PLEASE
 NOTE ON PLANS. THERE SHOULD BE A REGULATOR IN THE
 EXISTING SYSTEM SHOWN. THE GENERATOR IS AT 1 1/4
 INCHES, BUT IT MAY NEED TO BE RESIZED ACCORDING TO THE
 LONGEST RUN. WOULD YOU PLEASE CLARIFY AND CORRECT PET
 THE PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
 2. WHERE REGULATORS ARE INSTALLED, WOULD YOU PLEASE
 SUBMIT THE MANUFACTURER?S SPECIFICATIONS FOR THE
 PRESSURE REGULATORS. REGULATORS INSTALLED ON THE
 EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR
 INSTALLATION PER THE 2020 FBC RES. SEC. G2421.1.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION,
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-08-26 Cont ID  
Sent By lcrespo Date 2021-08-26 Time 16:51 Rev Time 0.00
Received By lcrespo Date 2021-08-18 Time 07:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-08-16 Cont ID  
Sent By cthroop Date 2021-08-16 Time 17:42 Rev Time 0.00
Received By cthroop Date 2021-07-22 Time 14:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2021-08-26 Cont ID  
Sent By lcrespo Date 2021-08-26 Time 16:51 Rev Time 0.00
Received By lcrespo Date 2021-08-26 Time 16:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-08-04 Cont ID  
Sent By lcrespo Date 2021-08-04 Time 09:59 Rev Time 0.00
Received By lcrespo Date 2021-08-03 Time 12:47 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-08-16 Cont ID  
Sent By cthroop Date 2021-08-16 Time 17:42 Rev Time 0.00
Received By cthroop Date 2021-08-14 Time 08:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-08-06 Cont ID  
Sent By kalexand Date 2021-08-06 Time 14:22 Rev Time 0.00
Received By kalexand Date 2021-08-06 Time 14:22 Sent To  
Notes
2021-08-06 14:23:48AS STAMPED ON PLANS THE GENERATOR EQUIPMENT MUST BE A
 MINIMUM OF 4 FT FROM THE SIDE PROPERTY LINE.