Plan Review Stops For Permit 21071094 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2022-01-24 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-01-24 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-01-24 |
Time |
08:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2022-01-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-01-13 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-01-13 |
Time |
12:15 |
Sent To |
|
|
Notes |
2022-01-13 13:43:00 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL2533-R26 SELECTED SYSTEM NO. W-67 DO NOT | | MEET THE EXPOSURE CATEGORY C; ZONE 3 MINIMUM DESIGN | | PRESSURE REQUIREMENT OF -108.17. PLEASE SELECT SYSTEM | | NO. THAT MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE | | SIGNED AND SEALED ENGINEERED NAILING CALCULATION FOR | | ZONE 3. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE | | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN | | PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | OF PROVIDING POSITIVE DRAINAGE. SHOW LOCATION OF | | EXISTING SCUPPERS, SIZE OF SCUPPERS AND HEIGHT ABOVE | | ROOF DECK. SECOND REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2021-12-27 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-12-27 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-12-27 |
Time |
07:47 |
Sent To |
|
|
Notes |
2021-12-27 10:52:35 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | FL2533-R6 IS INCOMPLETE, PROVIDE THE FOLLOWING | | ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-4 TO | | INCLUDE LIMITATIONS PAGE(S). THE EVALUATION REPORTS CAN | | BE PRINTED FROM THE SUMMARY OF PRODUCTS LOCATED AT THE | | BOTTOM OF THE COVER PAGE. PRINT PAGES 1-5 ONLY. SECOND | | REQUEST | | 2. FBC EB 706.6 PROVIDE A FLASHING DETAIL DRAWING FOR | | THE EXISTING PARAPET WALLS TO INCLUDE PARAPET WALL | | HEIGHT(S). SECOND REQUEST. | | 3. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | OF PROVIDING POSITIVE DRAINAGE. SECOND REQUEST. | | 4. FBC B 107.2.1 PROVIDE A ROOF DRAINAGE PLAN THAT | | COMPLIES WITH SECTION 903.4 OF THE 2020 FBC-RESIDENTIAL | | AND CHAPTER 11 OF THE 2020 FBC-PLUMBING. SECOND | | REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-12-02 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-12-02 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-12-02 |
Time |
07:59 |
Sent To |
|
|
Notes |
2021-12-02 12:32:20 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | FL2533 R-26 IS INCOMPLETE, PROVIDE THE FOLLOWING | | ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-5 TO | | INCLUDE LIMITATIONS PAGE(S). | | 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL2533-R26 COVERS MULTIPLE ROOF SYSTEMS FOR | | WOOD DECKS; SYSTEM TYPE A1-F NO. W-1 THRU W-103. | | SELECTED SYSTEM TO BE USED. ALL APPLICABLE DETAILS AND | | ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT | | APPROVAL DRAWINGS. | | 3. FBC EB 706.6 PROVIDE A FLASHING DETAIL FOR THE | | EXISTING PARAPET WALLS TO INCLUDE PARAPET WALL | | HEIGHT(S). | | 4. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | OF PROVIDING POSITIVE DRAINAGE. | | 5. FBC B 107.2.1 PROVIDE A SIGN AND SEALED ROOF | | DRAINAGE PLAN THAT COMPLIES WITH SECTION 903.4 OF THE | | 2020 FBC-RESIDENTIAL AND CHAPTER 11 OF THE 2020 | | FBC-PLUMBING | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-09-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-09-23 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-09-23 |
Time |
11:52 |
Sent To |
|
|
Notes |
2021-09-23 13:13:35 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE PROVIDE A PRODUCT APPROVAL FOR THE FLAT | | ROOFING SYSTEM - PRODUCT APPROVAL FOR THE FLAT DECK | | ROOFING = NEED TO CHOOSE A ROOFING SYSTEM IN THE | | PRODUCT APPROVAL THAT SHOWS THE REQUIRED WIND DESIGN | | PRESSURE - PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED | | IN THE PRODUCT APPROVAL - IF NEEDED PLEASE PROVIDE | | ADDITIONAL ATTACHMENT DETAILS FROM AN ARCHITECT OR | | ENGINEER FOR THE ROOF ZONES 2 AND 3 WHICH MAY REQUIRE A | | HIGHER WIND PRESSURE THEN THE CHOSEN ROOFING SYSTEM - | | SEE NOTES ON THE PRODUCT APPROVAL. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-09-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-09-14 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-09-14 |
Time |
14:58 |
Sent To |
|
|
Notes |
2021-09-14 15:58:36 | PLAN REVIEW ROOFING | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE A SITE PLAN OR ROOF SKETCH OF STRUCTURE. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | | | 2. IDENTIFY TYPE OF UNDERLAYMENT FOR PROPOSED ROOFING. | | R905.1.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2022-01-24 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-01-24 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-01-18 |
Time |
17:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2022-01-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-01-13 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-01-11 |
Time |
08:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-12-27 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-12-27 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-12-17 |
Time |
07:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-12-02 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-12-02 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-12-01 |
Time |
07:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-09-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-09-23 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-09-23 |
Time |
08:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-09-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-09-14 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-09-07 |
Time |
10:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
5 |
Status |
P |
Date |
2022-01-24 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-01-24 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-01-24 |
Time |
08:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
F |
Date |
2022-01-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-01-13 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-01-13 |
Time |
12:15 |
Sent To |
|
|
Notes |
2022-01-13 13:43:22 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL2533-R26 SELECTED SYSTEM NO. W-67 DO NOT | | MEET THE EXPOSURE CATEGORY C; ZONE 3 MINIMUM DESIGN | | PRESSURE REQUIREMENT OF -108.17. PLEASE SELECT SYSTEM | | NO. THAT MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE | | SIGNED AND SEALED ENGINEERED NAILING CALCULATION FOR | | ZONE 3. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE | | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN | | PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | OF PROVIDING POSITIVE DRAINAGE. SHOW LOCATION OF | | EXISTING SCUPPERS, SIZE OF SCUPPERS AND HEIGHT ABOVE | | ROOF DECK. SECOND REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
F |
Date |
2021-12-27 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-12-27 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-12-27 |
Time |
07:47 |
Sent To |
|
|
Notes |
2021-12-27 10:52:11 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | FL2533-R6 IS INCOMPLETE, PROVIDE THE FOLLOWING | | ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-4 TO | | INCLUDE LIMITATIONS PAGE(S). THE EVALUATION REPORTS CAN | | BE PRINTED FROM THE SUMMARY OF PRODUCTS LOCATED AT THE | | BOTTOM OF THE COVER PAGE. PRINT PAGES 1-5 ONLY. SECOND | | REQUEST | | 2. FBC EB 706.6 PROVIDE A FLASHING DETAIL DRAWING FOR | | THE EXISTING PARAPET WALLS TO INCLUDE PARAPET WALL | | HEIGHT(S). SECOND REQUEST. | | 3. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | OF PROVIDING POSITIVE DRAINAGE. SECOND REQUEST. | | 4. FBC B 107.2.1 PROVIDE A ROOF DRAINAGE PLAN THAT | | COMPLIES WITH SECTION 903.4 OF THE 2020 FBC-RESIDENTIAL | | AND CHAPTER 11 OF THE 2020 FBC-PLUMBING. SECOND | | REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2021-12-02 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-12-02 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-12-02 |
Time |
07:59 |
Sent To |
|
|
Notes |
2021-12-02 12:32:57 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | FL2533 R-26 IS INCOMPLETE, PROVIDE THE FOLLOWING | | ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-5 TO | | INCLUDE LIMITATIONS PAGE(S). | | 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL2533-R26 COVERS MULTIPLE ROOF SYSTEMS FOR | | WOOD DECKS; SYSTEM TYPE A1-F NO. W-1 THRU W-103. | | SELECTED SYSTEM TO BE USED. ALL APPLICABLE DETAILS AND | | ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT | | APPROVAL DRAWINGS. | | 3. FBC EB 706.6 PROVIDE A FLASHING DETAIL FOR THE | | EXISTING PARAPET WALLS TO INCLUDE PARAPET WALL | | HEIGHT(S). | | 4. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | OF PROVIDING POSITIVE DRAINAGE. | | 5. FBC B 107.2.1 PROVIDE A SIGN AND SEALED ROOF | | DRAINAGE PLAN THAT COMPLIES WITH SECTION 903.4 OF THE | | 2020 FBC-RESIDENTIAL AND CHAPTER 11 OF THE 2020 | | FBC-PLUMBING | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-09-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-09-23 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-09-23 |
Time |
12:36 |
Sent To |
|
|
Notes |
2021-09-23 12:38:14 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE PROVIDE A PRODUCT APPROVAL FOR THE FLAT | | ROOFING SYSTEM - PRODUCT APPROVAL FOR THE FLAT DECK | | ROOFING = NEED TO CHOOSE A ROOFING SYSTEM IN THE | | PRODUCT APPROVAL THAT SHOWS THE REQUIRED WIND DESIGN | | PRESSURE - PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED | | IN THE PRODUCT APPROVAL - IF NEEDED PLEASE PROVIDE | | ADDITIONAL ATTACHMENT DETAILS FROM AN ARCHITECT OR | | ENGINEER FOR THE ROOF ZONES 2 AND 3 WHICH MAY REQUIRE A | | HIGHER WIND PRESSURE THEN THE CHOSEN ROOFING SYSTEM - | | SEE NOTES ON THE PRODUCT APPROVAL. | | |
|
|