Plan Review Details - Permit 21071046
Plan Review Stops For Permit 21071046
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-08-26 Cont ID  
Sent By rmcphers Date 2021-08-26 Time 11:51 Rev Time 0.00
Received By rmcphers Date 2021-08-26 Time 11:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-08-03 Cont ID  
Sent By rmcphers Date 2021-08-03 Time 12:56 Rev Time 0.00
Received By rmcphers Date 2021-08-03 Time 12:55 Sent To  
Notes
2021-08-03 12:59:41AWNING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) PLEASE PROVIDE A SITE PLAN SHOWING THE LOCATION OF
 THE AWNING.
 2) PLEASE SHOW THE HEIGHT FROM GRADE TO THE BOTTOM OF
 THE AWNING FBC 3105.3.1

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-08-19 Cont ID  
Sent By pleduc Date 2021-08-19 Time   Rev Time 0.00
Received By pleduc Date 2021-08-19 Time 11:04 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-07-23 Cont ID  
Sent By pleduc Date 2021-07-23 Time   Rev Time 0.00
Received By pleduc Date 2021-07-23 Time 14:37 Sent To  
Notes
2021-07-23 14:39:30THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THE IS NO SITE PLAN NOR BUILDING PLAN/SKETCH
 INDICATING WHERE THE AWNING WILL BE INSTALLED AND A
 WHAT HEIGHT
  
 PLEASE PROVIDE DETAILS.
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-08-16 Cont ID  
Sent By fmittner Date 2021-08-16 Time 14:21 Rev Time 0.00
Received By fmittner Date 2021-08-16 Time 14:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-08-26 Cont ID  
Sent By rmcphers Date 2021-08-26 Time 11:51 Rev Time 0.00
Received By rmcphers Date 2021-08-18 Time 06:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-08-17 Cont ID  
Sent By rmcdouga Date 2021-08-17 Time 08:11 Rev Time 0.00
Received By rmcdouga Date 2021-07-22 Time 09:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-08-26 Cont ID  
Sent By rmcphers Date 2021-08-26 Time 11:51 Rev Time 0.00
Received By rmcphers Date 2021-08-26 Time 11:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-08-03 Cont ID  
Sent By rmcphers Date 2021-08-03 Time 12:59 Rev Time 0.00
Received By rmcphers Date 2021-08-03 Time 12:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-08-23 Cont ID  
Sent By llouie Date 2021-08-23 Time   Rev Time 0.00
Received By llouie Date 2021-08-23 Time   Sent To  
Notes
2021-08-23 08:48:54* SEE PLAN MARK-UPS.

Review Stop Z ZONING
Rev No 1 Status F Date 2021-08-13 Cont ID  
Sent By llouie Date 2021-08-13 Time   Rev Time  
Received By llouie Date 2021-08-13 Time   Sent To  
Notes
2021-08-13 11:17:36** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) PROVIDE AN UPDATED SIGNED AND SEALED SURVEY.
  
 2.) SHOW THE LOCATION OF THE PROPOSED AWNING IN A SITE
 PLAN. THE PERMIT PLANS DO NOT SHOW THE LOCATION OF THE
 PROPOSED AWNING.
  
 3.) MINIMUM VERTICAL CLEARANCE OF 8 FT. IS REQUIRED.
 THIS MUST BE NOTED IN THE PERMIT PLAN. [ZLDR S.94-209,
 TABLE VII-1, PROJECTIONS AND ENCROACHMENTS]
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: NMUD-TRANSITION
  