Plan Review Details - Permit 21070939
Plan Review Stops For Permit 21070939
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-09-15 Cont ID  
Sent By rmcdouga Date 2021-09-15 Time 12:53 Rev Time 0.00
Received By rmcdouga Date 2021-09-15 Time 12:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-08-20 Cont ID  
Sent By rmcdouga Date 2021-08-20 Time 13:17 Rev Time 0.00
Received By rmcdouga Date 2021-08-20 Time 11:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-09-15 Cont ID  
Sent By ppetty Date 2021-09-15 Time 08:55 Rev Time 0.00
Received By ppetty Date 2021-09-15 Time 08:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-07-28 Cont ID  
Sent By ppetty Date 2021-07-28 Time 09:18 Rev Time 0.00
Received By ppetty Date 2021-07-28 Time 09:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-09-15 Cont ID  
Sent By lmarchan Date 2021-09-15 Time 09:25 Rev Time 0.00
Received By lmarchan Date 2021-09-14 Time 15:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-08 Cont ID  
Sent By lmarchan Date 2021-09-08 Time 09:50 Rev Time 0.00
Received By lmarchan Date 2021-08-25 Time 16:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-08-20 Cont ID  
Sent By rmcdouga Date 2021-08-20 Time 13:17 Rev Time 0.00
Received By rmcdouga Date 2021-07-20 Time 12:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-07-21 Cont ID  
Sent By lcrespo Date 2021-07-21 Time 14:04 Rev Time 0.00
Received By lcrespo Date 2021-07-21 Time 14:04 Sent To  
Notes
2021-07-21 14:05:3307/21/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-09-15 Cont ID  
Sent By rmcdouga Date 2021-09-15 Time 12:54 Rev Time 0.00
Received By rmcdouga Date 2021-09-15 Time 12:54 Sent To  
Notes
2021-09-15 12:56:41THE NEW PLANS THAT WERE UPLOADED ON 9/14/2021 HAVE NOT
 BEEN DIGITALLY SIGNED. ELECTRONICALLY SUBMITTED
 DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT OR
 ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE
 OPTION TO SUBMIT THE SIGNED AND SEALED PAPER VERSION OF
 DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE BEEN
 APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER
 DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE
 ARCHITECT OR ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE
 AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. NO
 PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE
 ACCEPTABLE. FS 487 & 61G1 OR FS 471 & 61G15

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-07-20 Cont ID  
Sent By medwards Date 2021-07-20 Time 16:39 Rev Time 0.00
Received By medwards Date 2021-07-20 Time 16:37 Sent To  
Notes
2021-07-20 16:39:44ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO
 STORAGE.ME

Review Stop Z ZONING
Rev No 3 Status P Date 2021-09-14 Cont ID  
Sent By jroach Date 2021-09-14 Time 15:53 Rev Time 0.00
Received By jroach Date 2021-09-14 Time 15:52 Sent To  
Notes
2021-09-14 15:54:15PROVISOS:
  
 1. ALL POOL EQUIPMENT SHALL BE A MINIMUM OF ONE (1)
 FOOT FROM THE SIDE PROPERTY LINE.
  
 2. POOL SHALL BE ENCLOSED BY A PERMANENT FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE
 RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED
 (?BABY FENCE? DOES NOT MEET THIS REQUIREMENT). BARRIERS
 OR FENCES SHALL BE AT LEAST 4 FEET IN HEIGHT ABOVE
 GRADE.
  
 3. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH
 A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING
 GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES
 PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE.
  
 4. PATIO OR PAVED AREA ADJACENT TO OR SURROUNDING THE
 POOL SHALL BE DESIGNED TO DRAIN AWAY FROM THE POOL, BUT
 NOT ONTO ADJACENT PROPERTIES.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG

Review Stop Z ZONING
Rev No 2 Status F Date 2021-09-07 Cont ID  
Sent By jroach Date 2021-09-07 Time 16:58 Rev Time 0.00
Received By jroach Date 2021-09-07 Time 16:58 Sent To  
Notes
2021-09-07 17:08:45ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 09.07.2021
 PERMIT NO.: 21070939
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. [ PARTIALLY SATISFIED ] - A CURRENT AND ACCURATE
 SURVEY OF THE PROPERTY SHALL BE PROVIDED.
  
 1.1 [ NEW COMMENT ] - THE IMPROVEMENTS SHOWN ON THE
 SURVEY ARE ILLEGIBLE. THEY APPEAR TO ALSO SHOW
 IMPROVEMENTS BEYOND JUST THE POOL (ASTRO TURF, ETC.).
  
 2. [ NOT SATISFIED ] - THE POOL PLAN SHOWING THE
 PROPOSED IMPROVEMENTS IS NOT LEGIBLE. PLEASE PROVIDE A
 PLAN THAT CLEARLY IDENTIFY ALL ELEMENTS OF THE PROPOSED
 IMPROVEMENTS.
  
 3. [ NOT SATISFIED ] - THE PLAN MENTIONS WHAT APPEARS
 TO BE ARTIFICIAL TURF PROPOSED IN THE SIDES AND REAR OF
 THE PROPERTY. PURSUANT TO THE CITY?S ZLDRS A SEPARATE
 PERMIT SHALL BE OBTAINED. PLEASE SUBMIT A PERMIT
 APPLICATION FOR THE ARTIFICIAL TURF, WITH ALL REQUIRED
 DOCUMENTATION, TO THE CITY?S BUILDING DIVISION.
  
 4. [ SATISFIED ] - THE SETBACK FROM THE PROPERTY LINE
 TO THE POOL EQUIPMENT SHALL BE PROVIDED.
  
 5. [ PARTIALLY SATISFIED ] - THE SETBACKS FROM ALL
 PROPERTY LINES TO THE WATERS EDGE SHALL BE PROVIDED.
  
 5.1 [ NEW COMMENT ] - THE LOCATION OF THE DIMENSION
 PROVIDED (7 FT) DOES NOT APPEAR TO BE THE POINT WHERE
 THE WATER IS CLOSEST TO THE PROPERTY LINE. THE SETBACK
 IS TO BE MEASURED AT THE SHORTEST DIMENSION.
  
 6. [ NOT SATISFIED ] - THE SETBACKS FROM ALL PROPERTY
 LINES TO THE POOL DECK SHALL BE PROVIDED.
  
 6.1 [ NEW COMMENT ] - THE LOCATION OF THE DIMENSION
 PROVIDED (7 FT) DOES NOT APPEAR TO BE THE POINT WHERE
 THE WATER IS CLOSEST TO THE PROPERTY LINE. THE SETBACK
 IS TO BE MEASURED AT THE SHORTEST DIMENSION.
  
 7. [ PARTIALLY SATISFIED ] - POOL SHALL BE ENCLOSED BY
 A PERMANENT FENCE OR SIMILAR STRUCTURE WHICH IS
 INSTALLED TO OBSTRUCT ACCESS BY PERSONS OTHER THAN THE
 OWNERS OR OCCUPANTS OF THE RESIDENCE WITHIN WHICH A
 SWIMMING POOL IS LOCATED (?BABY FENCE? DOES NOT MEET
 THIS REQUIREMENT). BARRIERS OR FENCES SHALL BE AT LEAST
 4 FEET IN HEIGHT ABOVE GRADE. ACCESS TO AN ACCESSORY
 SWIMMING POOL MUST BE THROUGH A BUILDING OR THROUGH A
 SELF-CLOSING AND SELF-LATCHING GATE OR THROUGH A SCREEN
 ENCLOSURE DOOR WITH LATCHES PLACED AT LEAST 54 INCHES
 ABOVE BOTTOM OF GATE. PLEASE CLEARLY INDICATE THE
 LOCATION OF THE FENCE; AND A SEPARATE PERMIT WILL BE
 REQUIRED.
  
 7.1 [ NEW COMMENT ] - A FENCE IS SHOWN ON THE PLAN BUT
 NO DETAILS WERE PROVIDED. IS THE FENCE A PART OF THE
 SCOPE OF THIS PERMIT, OR IS A SEPARATE PERMIT BEING
 APPLIED FOR?
  
 8. [ NEW COMMENT ] - WRITTEN RESPONSES TO PREVIOUS
 COMMENTS WERE NOT PROVIDED.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 2021-08-13 Cont ID  
Sent By jroach Date 2021-08-13 Time 15:09 Rev Time 0.00
Received By jroach Date 2021-08-13 Time 15:08 Sent To  
Notes
2021-08-13 15:09:11ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 08.13.2021
 PERMIT NO.: 21070939
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. A CURRENT AND ACCURATE SURVEY OF THE PROPERTY SHALL
 BE PROVIDED.
  
 2. THE POOL PLAN SHOWING THE PROPOSED IMPROVEMENTS IS
 NOT LEGIBLE. PLEASE PROVIDE A PLAN THAT CLEARLY
 IDENTIFY ALL ELEMENTS OF THE PROPOSED IMPROVEMENTS.
  
 3. THE PLAN MENTIONS WHAT APPEARS TO BE ARTIFICIAL TURF
 PROPOSED IN THE SIDES AND REAR OF THE PROPERTY.
 PURSUANT TO THE CITY?S ZLDRS A SEPARATE PERMIT SHALL BE
 OBTAINED. PLEASE SUBMIT A PERMIT APPLICATION FOR THE
 ARTIFICIAL TURF, WITH ALL REQUIRED DOCUMENTATION, TO
 THE CITY?S BUILDING DIVISION.
  
 4. THE SETBACK FROM THE PROPERTY LINE TO THE POOL
 EQUIPMENT SHALL BE PROVIDED.
  
 5. THE SETBACKS FROM ALL PROPERTY LINES TO THE WATERS
 EDGE SHALL BE PROVIDED.
  
 6. THE SETBACKS FROM ALL PROPERTY LINES TO THE POOL
 DECK SHALL BE PROVIDED.
  
 7. POOL SHALL BE ENCLOSED BY A PERMANENT FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE
 RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED
 (?BABY FENCE? DOES NOT MEET THIS REQUIREMENT). BARRIERS
 OR FENCES SHALL BE AT LEAST 4 FEET IN HEIGHT ABOVE
 GRADE. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE
 THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND
 SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR
 WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF
 GATE. PLEASE CLEARLY INDICATE THE LOCATION OF THE
 FENCE; AND A SEPARATE PERMIT WILL BE REQUIRED.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved