Plan Review Details - Permit 21070873
Plan Review Stops For Permit 21070873 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-08-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-08-10 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-08-10 |
Time |
15:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-07-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-07-22 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-07-21 |
Time |
16:02 |
Sent To |
|
|
Notes |
2021-07-22 12:09:50 | 1ST REVIEW FBC-2020 RES. BUILDING. | | PERMIT- 21070873 | | 7/23/21 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SEE LIMITATIONS NOTE 5.7.2 ON PAGE 4 OF THE | | EVALUATION REPORT REPORT FOR THE ROOFING SYSTEM. THE | | SELECTED W-1 SYSTEM SHOWS AN MDP OF -52.5 PSF WHICH | | APPEARS TO BE INADEQUATE BASED ON THE ENGINEERED WIND | | PRESSURE CALCULATIONS FOR THE BUILDING THAT ARE SHOWN | | ON SHEET S4.2 OF THE APPROVED PLANS UNDER PERMIT | | 2101099. USING THE 10 SQ. FT. EFFECTIVE WIND AREA AS | | PROVIDED IN THE CALCULATION TABLE, PRIME ZONE 1 IS | | INDICATED TO BE -57.0 PSF. PLEASE SELECT A SYSTEM | | DESIGN THAT MEETS COMPLIANCE AND RESUBMIT THE COMPLETE | | PRODUCT APPROVAL OR NOA. | | | | 2) REFER TO SECTIONS 107.3.4 AND 107.3.4.1 WPB | | AMENDMENTS TO THE FBC. AS STATED IN THE SECTIONS, THE | | DEFERRED ROOFING SYSTEM SUBMITTALS SHALL BE REVIEWED | | AND NOTED, OR STAMPED AS APPROVED BY THE DESIGN | | PROFESSIONAL IN RESPONSIBLE CHARGE OF THE MAIN BUILDING | | PROJECT. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | BUILDING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-08-10 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-07-28 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-07-22 |
Time |
|
Rev Time |
0.00 |
Received By |
cdecoeur |
Date |
2021-07-20 |
Time |
14:59 |
Sent To |
|
|
Notes |
|
|
|