Plan Review Stops For Permit 21070330 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-02-10 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-10 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-10 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-07-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-07-21 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-07-21 |
Time |
12:51 |
Sent To |
|
|
Notes |
2021-07-21 12:57:11 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. SHEET S2 GIVES SPECIFICATION OF FBC 2017, GOVERNING | | CODE IS FBC 2020, CHECK ALL CODE REFERENCES. | | | | 2. SEE S1, S5, IT APPEARS THAT THE ENGINEER IS | | SPECIFYING A MINIMUM FOOTING, BUT PLANS STATE THAT THE | | EXISTING FOOTING WILL BE USED. NO INFORMATION WAS | | PROVIDED ABOUT THE EXISTING FOOTING. PROVIDE A DETAIL | | FOR THE EXISTING FOOTING TO SHOW THAT IT MEETS THE | | ENGINEER'S SPECIFICATION. REVISE PLAN TO CLARIFY THAT | | THE EXISTING FOOTING WILL BE USED, IF THAT IS THE CASE. | | | | REVISE PLAN ACCORDINGLY. THIS INFORMATION IS INCLUDED | | ON PAGE 001 COVERSHEET BUT THAT PAGE IS NOT SIGNED AND | | SEALED, FS471. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-02-03 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-02-03 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-02-03 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-07-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-07-26 |
Time |
07:23 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-07-26 |
Time |
07:14 |
Sent To |
|
|
Notes |
2021-07-26 07:24:53 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | NO ELECTRIC SHOWN, PLEASE SUBMIT A LAYOUT OF THE | | ELECTRIC IN THE SIGN AND TO THE SIGN. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-02-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-02-22 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-02-14 |
Time |
06:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-02-10 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-10 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-20 |
Time |
07:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-07-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-07-26 |
Time |
07:25 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-07-09 |
Time |
09:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-02-03 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-02-03 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-02-03 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-07-13 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-07-13 |
Time |
07:01 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-07-13 |
Time |
07:01 |
Sent To |
|
|
Notes |
2021-07-13 07:04:07 | THE DRAWINGS HAVE A PRINTED COPY OF A DIGITAL | | SIGNATURE. WE CANNOT ACCEPT A COPY OF A DIGITAL | | SIGNATURE. PLEASE UPLOAD THE ORIGINAL DIGITALLY SIGNED | | DRAWINGS INTO YOUR PROJECT PORTAL OR YOU CAN BRING THE | | ORIGINAL SIGNED AND SEALED PAPER DRAWINGS TO OUR | | OFFICE. FS 471. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-02-22 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2022-02-22 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2022-02-22 |
Time |
|
Sent To |
|
|
Notes |
2022-02-22 14:06:41 | * NEW MONUMENT SIGN TO REPLACE EXISTING MONUMENT SIGN | | IN EXACT SAME LOCATION WITH EXACT SAME FOOTPRINT. | | | | * REFERENCE: RESOLUTION NO. 338-20 (HOLIDAY INN EXPRESS | | OCPD) |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-02-02 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2022-02-02 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2022-02-02 |
Time |
|
Sent To |
|
|
Notes |
2022-02-02 09:24:49 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | THE SCOPE OF WORK REQUIRES THE ELIMINATION OF THE | | EXISTING FREESTANDING SIGN STRUCTURE. AS A RESULT, THE | | FOLLOWING INFORMATION SHALL BE REQUIRED: | | | | 1.) UPDATED, SIGNED AND SEALED SURVEY OF THE PROPERTY. | | [7/22/2021 REPEAT COMMENT: NOT PROVIDED IN THE PERMIT | | RESUBMITTAL. SENT DAN MAY OF FERRIN SIGNS A COPY OF THE | | SURVEY TO UPLOAD IN NEXT RESUBMITTAL.] | | | | 2.) PROVIDE A SITE PLAN SHOWING THE EXACT LOCATION OF | | THE PROPOSED SIGN STRUCTURE AND SETBACK DIMENSIONS TO | | THE PROPERTY LINE. IF THE LOCATION OF THE SIGNAGE HAS | | CHANGED, A MINOR AMENDMENT TO THE HOLIDAY INN OFFICE | | COMMERCIAL PLANNED DEVELOPMENT (OCPD) WILL BE REQUIRED. | | [7/22/2021 MODIFIED COMMENT: THE SITE PLAN IN THE | | PERMIT PLANS IS NOT THE APPROVED SITE PLAN FOR THE | | HOLIDAY INN EXPRESS OCPD. SENT DAN MAY OF FERRIN SIGNS | | THE LATEST APPROVED SITE PLAN TO PROVIDE LOCATION AND | | SETBACK DISTANCE FROM THE PROPOSED SIGN TO THE PROPERTY | | LINE(S)]. | | | | | | NOTES: | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: OCPD (HOLIDAY INN EXPRESS) | | | | * LF FRONTAGE = 138.06 FT. (X 0.5 FOR MAX. ALLOWABLE | | SIGN AREA) - PROPOSED SIGN = 44.2 SQ. FT. | | | | * SPOKE TO DAN MAY OF FERRIN SIGNS ON 2/2/22 - PROPOSED | | NEW MONUMENT SIGN LOCATION IS THE SAME AS EXISTING; | | FOOTPRINT AND SIZE OF SIGN WILL BE SMALLER THAN | | EXISTING TO BE REPLACED. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-07-22 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2021-07-22 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2021-07-22 |
Time |
|
Sent To |
|
|
Notes |
2021-07-22 14:33:52 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | THE SCOPE OF WORK REQUIRES THE ELIMINATION OF THE | | EXISTING FREESTANDING SIGN STRUCTURE. AS A RESULT, THE | | FOLLOWING INFORMATION SHALL BE REQUIRED: | | | | 1.) UPDATED, SIGNED AND SEALED SURVEY OF THE PROPERTY. | | | | 2.) PROVIDE A SITE PLAN SHOWING THE EXACT LOCATION OF | | THE PROPOSED SIGN STRUCTURE AND SETBACK DIMENSIONS TO | | THE PROPERTY LINE. IF THE LOCATION OF THE SIGNAGE HAS | | CHANGED, A MINOR AMENDMENT TO THE HOLIDAY INN OFFICE | | COMMERCIAL PLANNED DEVELOPMENT (OCPD) WILL BE REQUIRED. | | | | 3.) MAXIMUM HEIGHT OF THE PROPOSED FREESTANDING SIGN | | CANNOT EXCEED 10 FT. THE PROPOSED SIGN IS 14 FT. TALL | | WHICH EXCEEDS THE MAXIMUM ALLOWABLE HEIGHT. [ZLDR | | S.94-408(A)(2)] | | | | | | NOTES: | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: OCPD (HOLIDAY INN EXPRESS) | | | | * LF FRONTAGE = 138.06 FT. (X 0.5 FOR MAX. ALLOWABLE | | SIGN AREA) | | |
|
|