Plan Review Details - Permit 21070146
Plan Review Stops For Permit 21070146
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2021-10-13 Cont ID  
Sent By rmcphers Date 2021-10-13 Time 09:29 Rev Time 0.00
Received By rmcphers Date 2021-10-13 Time 09:29 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-09-15 Cont ID  
Sent By rmcphers Date 2021-09-15 Time 12:44 Rev Time 0.00
Received By rmcphers Date 2021-09-15 Time 12:44 Sent To  
Notes
2021-09-15 12:45:28PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-08-09 Cont ID  
Sent By rmcphers Date 2021-08-09 Time 14:25 Rev Time 0.00
Received By rmcphers Date 2021-08-09 Time 14:24 Sent To  
Notes
2021-08-09 14:25:47PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-10-13 Cont ID  
Sent By rmcphers Date 2021-10-13 Time 09:30 Rev Time 0.00
Received By rmcphers Date 2021-10-13 Time 09:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-09-15 Cont ID  
Sent By rmcphers Date 2021-09-15 Time 12:35 Rev Time 0.00
Received By rmcphers Date 2021-09-15 Time 12:35 Sent To  
Notes
2021-09-15 12:37:18OFFICE ALT.
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 LOCATION OF GRAB BAR BACKING SHOULD ALSO BE SHOWN FOR
 THE SHOWER WALLS - FBC A 608.3 GRAB BARS.
 GRAB BARS SHALL COMPLY WITH 609 AND SHALL BE PROVIDED
 IN ACCORDANCE WITH 608.3. WHERE MULTIPLE GRAB BARS ARE
 USED, REQUIRED HORIZONTAL GRAB BARS SHALL BE INSTALLED
 AT THE SAME HEIGHT ABOVE THE FINISH FLOOR.
 EXCEPTIONS:
 1.GRAB BARS SHALL NOT BE REQUIRED TO BE INSTALLED IN A
 SHOWER LOCATED IN A BATHING FACILITY FOR A SINGLE
 OCCUPANT ACCESSED ONLY THROUGH A PRIVATE OFFICE, AND
 NOT FOR COMMON USE OR PUBLIC USE PROVIDED THAT
 REINFORCEMENT HAS BEEN INSTALLED IN WALLS AND LOCATED
 SO AS TO PERMIT THE INSTALLATION OF GRAB BARS COMPLYING
 WITH 608.3.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-08-09 Cont ID  
Sent By rmcphers Date 2021-08-09 Time 14:36 Rev Time 0.00
Received By rmcphers Date 2021-08-09 Time 12:39 Sent To  
Notes
2021-08-09 14:36:38OFFICE ALT.
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) DRAWING A3.2 SHOWS THE LENGTH OF THE REAR GRAB BAR
 BACKING INCORRECTLY (NOT LONG ENOUGH) - PLEASE SHOW THE
 LENGTH OF THE BACKING TO COVER THE GRAB BAR AREA PER
 FBC 604.5.2
 2) PLEASE PROVIDE A GRAB BAR BACKING DETAIL FBC 609.8
 STRUCTURAL STRENGTH.
 ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS
 USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS
 (1112 N) IS APPLIED AT ANY POINT ON THE GRAB BAR,
 FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE.
 3) ROOMS 101, 102, AND 111 - A SWING DOOR IS REQUIRED
 FOR EGRESS PER FBC 1010.1.2 DOOR SWING.
 EGRESS DOORS SHALL BE OF THE PIVOTED OR SIDE-HINGED
 SWINGING TYPE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-08-04 Cont ID  
Sent By jleahy Date 2021-08-04 Time 09:47 Rev Time 0.00
Received By jleahy Date 2021-08-03 Time 16:09 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-01-24 Cont ID  
Sent By jleahy Date 2022-01-24 Time 15:35 Rev Time 0.00
Received By jleahy Date 2022-01-24 Time 15:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-08-17 Cont ID  
Sent By pleduc Date 2021-08-17 Time   Rev Time 0.00
Received By pleduc Date 2021-08-17 Time 09:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-07-09 Cont ID  
Sent By pleduc Date 2021-07-09 Time   Rev Time 0.00
Received By pleduc Date 2021-07-09 Time 15:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-10-22 Cont ID  
Sent By lcrespo Date 2021-10-22 Time 15:00 Rev Time 0.00
Received By lcrespo Date 2021-09-21 Time 10:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-15 Cont ID  
Sent By rmcphers Date 2021-09-15 Time 12:46 Rev Time 0.00
Received By rmcphers Date 2021-08-16 Time 10:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-08-09 Cont ID  
Sent By rmcphers Date 2021-08-09 Time 14:36 Rev Time 0.00
Received By rmcphers Date 2021-07-07 Time 12:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-08-05 Cont ID  
Sent By medwards Date 2021-08-05 Time 10:46 Rev Time 0.00
Received By medwards Date 2021-08-05 Time 10:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-10-22 Cont ID  
Sent By lcrespo Date 2021-10-22 Time 15:00 Rev Time 0.00
Received By lcrespo Date 2021-10-22 Time 15:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-09-14 Cont ID  
Sent By ccole Date 2021-09-14 Time 16:19 Rev Time 0.00
Received By ccole Date 2021-09-14 Time 14:59 Sent To  
Notes
2021-09-14 16:19:492ND REVIEW FBC-2020 PLUMBING
 PERMIT- 21070146
 9/14/21
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHT. A3.2: GRAB BAR REINFORCEMENT DETAILS FOR THE
 SHOWER NOT PROVIDED- SECTION 608.3 EXCEPTION 2 FBC ACC.
 PLEASE SEE SECTION AND FIGURE 608.3.2 AND 609.4.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-07-28 Cont ID  
Sent By tklarge Date 2021-07-28 Time 13:11 Rev Time 0.00
Received By tklarge Date 2021-07-28 Time 05:14 Sent To  
Notes
2021-07-28 13:04:411) SHT. A3.2 - THE SHOWER WIDTH IS SHOWN AS 2'-6" AND
 ALSO AS 36 INCHES ON THE PLAN. WHICH IS IT? CLARIFY.
 2) SHT. A3.2 - DETAIL #1 - SHOW THE DIMENSIONS OF THE
 BLOCKING AND THE TYPE OF MATERIAL USED FOR THE
 REINFORCEMENT OF THE FUTURE GRAB BARS.WPB AMEND. TO FBC
 SEC. 107.2.1.
 3) SHT. A5.1 - DETAIL #11 - THE SHOWER FLOOR SHALL
 SLOPE A MINIMUM OF 1/4 INCH PER FOOT TO THE DRAIN, NOT
 1/8 OF AN INCH. FBC-PLUMBING SEC. 421.5.2.
 4) SUBMIT FIRESTOPPING DETAILS FOR ANY FLOOR
 PENETRATIONS THAT MAY OCCUR. WPB AMEND. TO FBC SEC.
 107.3.5.1.1(4).
 5) SHT. ALS 1.1 - THE LIFESAFETY PLAN SHOWS AN
 OBJECTNEXT TO THE WATER CLOSET IN THEE PRIVATE TOILET
 ROOM #113 AND ON SHT. A1.5. IDENTIFY THIS OBJECT.IT MAY
 NOT BE PERMITTED TO ENCROACH INTO THE CLEAR FLOOR SPACE
 FOR THE WATER CLOSET.
 6) A BACKFLOW PREVENTION DEVICE IS REQUIRED ON THE
 CCOFFEE MAKER, DISHWASHER, ICEMAKER AND
 REFRIGERATOR.FBC-PLUMBING SEC.608.2, 608.17.1.2.
 7) SHT. P3.1 APPEARS TO SHOW THE TANKLESS WATER HEATER
 IN THE SHOWER. CLARIFY. THE IWH SHALL BE INSTALLED IN A
 LOCATION THAT ALLOWS ACCESS FOR MAINTENANCE AND
 REPLACEMENT.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-10-13 Cont ID  
Sent By rmcphers Date 2021-10-13 Time 09:30 Rev Time 0.00
Received By rmcphers Date 2021-10-13 Time 09:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-09-15 Cont ID  
Sent By rmcphers Date 2021-09-15 Time 12:38 Rev Time 0.00
Received By rmcphers Date 2021-09-15 Time 12:38 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-08-05 Cont ID  
Sent By medwards Date 2021-08-05 Time 12:46 Rev Time 0.00
Received By medwards Date 2021-08-05 Time 12:45 Sent To  
Notes
***NONE***