Plan Review Details - Permit 21061805
Plan Review Stops For Permit 21061805
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-08-21 Cont ID  
Sent By shill Date 2021-08-21 Time 07:01 Rev Time 0.00
Received By shill Date 2021-08-21 Time 07:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-21 Cont ID  
Sent By shill Date 2021-07-21 Time 07:33 Rev Time 0.00
Received By shill Date 2021-07-21 Time 07:33 Sent To  
Notes
2021-07-21 07:37:31****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. DEMO PLAN SHOWS THAT TILE WILL BE REMOVED FRO BATH
 #1, NO INFORMATION REGARDING REPLACEMENT FLOORING OR
 UNDERLAYMENT (SEE OTHER COMMENTS). FBC 107, REVISE PLAN
 TO SHOW FLOORING PROPOSED.
  
 2. SCOPE OF WORK ITEM 1 STATES THAT THIS WILL BE
 REMODEL OF MASTER BATH AND WALK IN CLOSET, PLAN SHOWS
 NO WORK IN THE CLOSET. FBC 107 PLEASE CORRELATE.
  
 3. SCOPE NOT CLEAR (SEE COMMENT 1). IF NEW FLOORING IS
 PROPOSED, PROVIDE THE FOLLOWING TEST REPORTS FOR THE
 UNDERLAYMENT:
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-08-24 Cont ID  
Sent By jleahy Date 2021-08-24 Time 14:26 Rev Time 0.00
Received By jleahy Date 2021-08-24 Time 14:25 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-07-14 Cont ID  
Sent By jleahy Date 2021-07-14 Time 09:08 Rev Time 0.00
Received By jleahy Date 2021-07-14 Time 09:05 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-08-10 Cont ID  
Sent By cwalker Date 2021-08-10 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-07-01 Cont ID  
Sent By cwalker Date 2021-07-01 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-08-24 Cont ID  
Sent By lcrespo Date 2021-08-24 Time 17:01 Rev Time 0.00
Received By lcrespo Date 2021-08-09 Time 09:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-21 Cont ID  
Sent By shill Date 2021-07-21 Time 07:37 Rev Time 0.00
Received By shill Date 2021-06-30 Time 14:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-08-24 Cont ID  
Sent By lcrespo Date 2021-08-24 Time 17:01 Rev Time 0.00
Received By lcrespo Date 2021-08-24 Time 17:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-07-14 Cont ID  
Sent By ccole Date 2021-07-14 Time 13:10 Rev Time 0.00
Received By ccole Date 2021-07-14 Time 12:54 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-08-24 Cont ID  
Sent By lcrespo Date 2021-08-24 Time 17:00 Rev Time 0.00
Received By lcrespo Date 2021-08-24 Time 16:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-07-01 Cont ID  
Sent By medwards Date 2021-07-01 Time 15:14 Rev Time 0.00
Received By medwards Date 2021-07-01 Time 15:14 Sent To  
Notes
2021-07-01 15:16:35ENGINEER NEEDS TO SIGN HIS SEAL ON THE PAPER DRAWINGS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  