Plan Review Details - Permit 21061742
Plan Review Stops For Permit 21061742
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-07-09 Cont ID  
Sent By jbrooks Date 2021-07-09 Time 13:32 Rev Time 0.00
Received By jbrooks Date 2021-07-09 Time 07:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-01 Cont ID  
Sent By jbrooks Date 2021-07-01 Time 08:21 Rev Time 0.00
Received By jbrooks Date 2021-07-01 Time 07:35 Sent To  
Notes
2021-07-01 08:22:24JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. SUBMITTED PRODUCT APPROVAL FL5259-R32 HAS BEEN
 REVISED TO FL5259-R33. PLEASE PROVIDE A COMPLETE SET.
 ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER
 RULE 61G20-3.
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL10497-R8 SELECTED SYSTEM NO. W-104 DO NOT
 MEET THE EXPOSURE CATEGORY C; ZONE 3 MINIMUM DESIGN
 PRESSURE REQUIREMENT OF -108.17. PLEASE SELECT SYSTEM
 NO. THAT MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE
 SIGNED AND SEALED ENGINEERED NAILING CALCULATION FOR
 ZONE 3. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE
 CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN
 PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 3. WPB A 109.3 BUILDING PERMIT VALUATIONS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS.
 VALUE TO INCLUDE LABOR AND MATERIALS, ARCHITECTURAL AND
 DESIGN FEES, OVERHEAD AND PROFIT. ATTACH SIGNED
 CONTRACT.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-09 Cont ID  
Sent By jbrooks Date 2021-07-09 Time 13:32 Rev Time 0.00
Received By jbrooks Date 2021-07-06 Time 10:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-01 Cont ID  
Sent By jbrooks Date 2021-07-01 Time 08:22 Rev Time 0.00
Received By jbrooks Date 2021-06-30 Time 10:54 Sent To  
Notes
***NONE***