|
 |
 |
 |
 |
 |
Plan Review Details - Permit 21061694
Plan Review Stops For Permit 21061694 |
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2021-07-19 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2021-07-19 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2021-07-19 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-08-04 |
Time |
|
Rev Time |
0.00 |
Received By |
bdolan |
Date |
2021-08-04 |
Time |
13:58 |
Sent To |
|
|
Notes |
2021-08-04 13:58:41 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | INSPECTIONS AND APPROVAL. | | THIS PLAN WAS REVIEWED AND APPROVED BY THE FIRE | | DEPARTMENT, WITH THE FOLLOWING COMMENTS: | | | | | | HYDROSTATIC TESTS. ALL PIPING AND ATTACHED | | APPURTENANCES SUBJECTED TO SYSTEM WORKING PRESSURE | | SHALL BE HYDROSTATICALLY TESTED AT 200 PSI (13.8 BAR) | | AND SHALL MAINTAIN THAT PRESSURE WITHOUT LOSS FOR 2 | | HOURS. | | | | DO NOT COVER/BURY FIRE LINE PIPING OR PAINT BOLTS PRIOR | | TO INSPECTIONS. | | | | LT. BRIAN DOLAN | | DIVISION OF FIRE PREVENTION | | 561-804-4752 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2021-07-06 |
|
|
Cont ID |
|
Sent By |
|
Date |
2021-07-06 |
Time |
|
Rev Time |
0.00 |
Received By |
bdolan |
Date |
2021-07-06 |
Time |
12:16 |
Sent To |
|
|
Notes |
2021-07-06 12:25:53 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | INSPECTIONS AND APPROVAL. | | THIS PLAN WAS REVIEWED AND APPROVED BY THE FIRE | | DEPARTMENT, WITH THE FOLLOWING COMMENTS: | | | | | | HYDROSTATIC TESTS. ALL PIPING AND ATTACHED | | APPURTENANCES SUBJECTED TO SYSTEM WORKING PRESSURE | | SHALL BE HYDROSTATICALLY TESTED AT 200 PSI (13.8 BAR) | | AND SHALL MAINTAIN THAT PRESSURE WITHOUT LOSS FOR 2 | | HOURS. | | | | DO NOT COVER/BURY FIRE LINE PIPING OR PAINT BOLTS PRIOR | | TO INSPECTIONS. | | | | LT. BRIAN DOLAN | | DIVISION OF FIRE PREVENTION | | 561-804-4752 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-08-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-08-06 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-07-20 |
Time |
13:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-07-20 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-07-20 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-06-30 |
Time |
10:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-08-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-02 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-02 |
Time |
09:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-07-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-07-19 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-07-19 |
Time |
08:17 |
Sent To |
|
|
Notes |
2021-07-19 10:08:40 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-21061694 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET FP 1 OF 1: UNDERGROUND SYMBOLS LEGEND IS | | INDICATING AN EXISTING 4 INCH BACKFLOW PREVENTER BUT | | THE DRAWING SHOWS THE SAME SYMBOL AS A NEW 4 INCH DDCV. | | FBC 107.2.1 | | | | 2) IN THE MATERIALS & ABBREVIATIONS CHART IT SHOWS A | | 6-INCH UNDERGROUND D.I.P. BUT THE DRAWING SHOWS IT TO | | BE A 4-INCH. PLEASE MAKE THE DRAWINGS CONSISTENT. FBC | | 107.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2021-08-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-02 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-02 |
Time |
09:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-07-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-07-19 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-07-19 |
Time |
08:56 |
Sent To |
|
|
Notes |
2021-07-19 08:58:48 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC 107, BACKFLOW SPECS WERE SUBMITTED. BACKFLOW | | REQUIRES A SEPARATE PERMIT. | | | | EMAIL A PERMIT APPLICATION FOR A BACKFLOW TO | | [email protected] AND SUBMIT FOR PLAN REVIEW (PAY | | FEES, UPLOAD SPECS). | | | | WHEN YOU EMAIL [email protected], REQUEST THAT | | THEY PASS THIS REVIEW. IF ALL OTHER REVIEWS HAVE | | PASSED, THE PERMIT WILL THEN BE ISSUED. | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |