Plan Review Details - Permit 21061341
Plan Review Stops For Permit 21061341 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2021-07-08 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-07-08 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-07-08 |
Time |
09:50 |
Sent To |
|
|
Notes |
2021-07-08 09:59:11 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1) THERE IS NO SITE PLAN INDICATING THE LOCATION OF THE | | FENCE, HEIGHT OF FENCE, TYPE OF FENCE, NOR ANY PROPOSED | | GATE LOCATIONS AND WIDTHS. | | | | EMERGENCY VEHICLE ACCESS WIDTHS (FIRE LANE) IS 20'. | | | | PLEASE PROVIDE DETAILS AND DIMENSIONS. | | | | 2) KNOX PADLOCKS ARE RECOMMENDED, NO REQUIRED, AT EACH | | GATE FOR FD EMEGENCY ACCESS AND SITE ACCESS. | | | | PLEASE PROVIDE AN APPLICABLE NOTE INDICATING KNOX | | PADLOCKS USE OR NOT. | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-07-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-07-21 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-06-30 |
Time |
17:09 |
Sent To |
|
|
Notes |
2021-07-21 17:00:44 | INITIALLY ROUTED IN ERROR. PLANS NEED TO BE UPLOADED, | | FEES PAID, PRIOR TO ROUTING TO REVIEW | | | | | 2021-06-23 10:26:17 | PLANS UNDER 20120712. CC |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-07-19 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2021-07-19 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2021-07-19 |
Time |
13:35 |
Sent To |
|
|
Notes |
2021-07-19 13:36:22 | PROVISOS: | | 1. LIGHTING POLES ALONG ROSEMAY AVENUE SHALL MATCH THE | | DOUBLE HEAD POLES BEING INSTALLED BY THE CITY ON EAST | | SIDE OF ROSEMARY, AND THE POLES AND FIXTURES ALONG 2ND | | AND 3RD SHALL MATCH THE DMP CITY STANDARD. SPECS BEING | | PROVIDED TO APPLICANT. | | 2. CONFIRM THE SIDEWALK ELEVATION IS MAINTAINED ACROSS | | THE PARKING GARAGE ENTRANCE. | | 3.PLEASE DISCUSS WITH ENG. DEPARTMENT THE POSIBILITY TO | | REGRADE ON-STREET PARKING TO DRAIN TOWARDS THE CENTER | | OR ROAD, AND RELOCATE THE GUTTER BETWEEN ON-STREET | | PARKING AND ROAD. THE GOAL IS TO ALLOW THE BULB OUTS AS | | A CONTINUOUS CURB. | | 4. DOG PARK FENCE SHALL BE MAX 4 FEET IN HEIGHT WHEN | | ALONG STREET FRONTAGE. | | 5. PRIVET TREES LOCATED NORTH OF THE SIDEWALK ON 2ND | | STREET SHALL BE REPLACED FOR LARGER SHADE TREES | | APROPRIATE FOR THE LOCATION. | | 6. PARAPET WALL SHALL FULLY SCREEN ANY ROOF TOP | | MECHANICAL EQUIPMENT. |
|
|
|