Plan Review Details - Permit 21061213
Plan Review Stops For Permit 21061213 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2021-08-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-08-13 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-08-13 |
Time |
07:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-08-11 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-08-11 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-08-11 |
Time |
11:34 |
Sent To |
|
|
Notes |
2021-08-11 14:12:56 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | FL2533-R25 IS INCOMPLETE, PROVIDE THE FOLLOWING | | ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-5 TO | | INCLUDE LIMITATIONS PAGE(S). | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-07-12 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-12 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-12 |
Time |
08:09 |
Sent To |
|
|
Notes |
2021-07-12 14:01:04 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED MIAMI-DADE COUNTY NOA | | 19-0610.05 IS NOT AN APPROVED ROOFING SYSTEM IT COVERS | | ROOFING MEMBRANE ONLY. PROVIDE A COMPLETE SET OF 2020 | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | FLAT ROOF SYSTEM TO BE USED. INCLUDE COVER PAGE, | | EVALUATION REPORTS AND INSTALLATION INSTRUCTIONS FOR | | SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY | | COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC | | ENGINEERING. SECOND REQUEST. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-07-07 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-07 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-07 |
Time |
07:49 |
Sent To |
|
|
Notes |
2021-07-07 09:35:23 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED FLAT ROOF SYSTEM TO BE | | USED. INCLUDE COVER PAGE, EVALUATION REPORTS AND | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | 2. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | DIAGRAM/SKETCH AND SHOW THE AREAS TO RECEIVE NEW | | ROOFING CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF | | SLOPE(S), ROOF HEIGHT(S). | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-08-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-08-13 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-08-12 |
Time |
08:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-08-11 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-08-11 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-08-09 |
Time |
07:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-07-12 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-12 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-08 |
Time |
11:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-07-07 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-07 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-06 |
Time |
11:31 |
Sent To |
|
|
Notes |
|
|
|