Plan Review Details - Permit 21061047
Plan Review Stops For Permit 21061047
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-06-22 Cont ID  
Sent By jwitmer Date 2021-06-22 Time 11:43 Rev Time 0.00
Received By jwitmer Date 2021-06-22 Time 09:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-08-02 Cont ID  
Sent By jleahy Date 2021-08-02 Time 15:10 Rev Time 0.00
Received By jleahy Date 2021-08-02 Time 14:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-07-01 Cont ID  
Sent By jleahy Date 2021-07-01 Time 16:55 Rev Time 0.00
Received By jleahy Date 2021-07-01 Time 16:49 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-06-22 Cont ID  
Sent By pleduc Date 2021-06-22 Time   Rev Time 0.00
Received By pleduc Date 2021-06-22 Time 11:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-08-23 Cont ID  
Sent By medwards Date 2021-08-23 Time 11:19 Rev Time 0.00
Received By medwards Date 2021-08-10 Time 12:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-08-04 Cont ID  
Sent By medwards Date 2021-08-04 Time 09:14 Rev Time 0.00
Received By medwards Date 2021-07-20 Time 13:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-07-06 Time   Rev Time 0.00
Received By lmarchan Date 2021-06-21 Time 09:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-08-23 Cont ID  
Sent By medwards Date 2021-08-23 Time 11:18 Rev Time 0.00
Received By medwards Date 2021-08-23 Time 11:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2021-08-04 Cont ID  
Sent By medwards Date 2021-08-04 Time 09:09 Rev Time 0.00
Received By medwards Date 2021-08-04 Time 09:09 Sent To  
Notes
2021-08-04 09:09:402ND REVIEW FBC-2020 MECHANICAL
 PERMIT
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THE
 PRODUCTION AREA. FBC EC C402
  
 2) PLEASE EXPLAIN THE NEW EXHAUST FANS IN THE CLOUDED
 AREA OF THE WAREHOUSE. THIS WAS NOT IN THE PREVIOUS
 SCOPE OF WORK. IT WAS ? EXISTING BUSINESS WAREHOUSE/
 RECEIVING (NO WORK WITHIN CROSSHATCHED AREA). FBC
 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-06-29 Cont ID  
Sent By medwards Date 2021-06-29 Time 09:33 Rev Time 0.00
Received By medwards Date 2021-06-29 Time 08:52 Sent To  
Notes
2021-06-29 09:34:35 
 1) PLEASE SUPPLY MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC EC C403.2.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-07-28 Cont ID  
Sent By ccole Date 2021-07-28 Time 16:27 Rev Time 0.00
Received By ccole Date 2021-07-28 Time 11:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-07-06 Cont ID  
Sent By ccole Date 2021-07-06 Time 14:34 Rev Time 0.00
Received By ccole Date 2021-07-06 Time 11:27 Sent To  
Notes
2021-07-06 14:34:591ST REVIEW FBC-2017 PLUMBING
 PERMIT REVISON- 21061047
 7/6/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 6TH EDITION 2017
 FBC B- FLORIDA BUILDING CODE 6TH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) AS NOTED IN THE APPROVED PLANS, THE IRRIGATION
 SYSTEM IS BE UNDER A SEPARATE PERMIT, HOWEVER THE PLANS
 APPEAR TO SHOW RUNOFF FROM THE IRRIGATION COLLECTED BY
 FLOOR DRAINS AND DRAINING INTO THE CITY SANITARY SEWER
 SYSTEM. PLEASE REVIEW SECTIONS 90-126 AND 90-203 &
 90-205 WPB CODE OF ORDINANCES. BASED ON THOSE SECTIONS
 IT APPEARS THE IRRIGATION DRAINAGE IS PROHIBITED FROM
 DRAINING INTO THE SANITARY. PLEASE PROVIDE ADDITIONAL
 INFORMATION ABOUT THE IRRIGATION SYSTEM AND WHAT THE
 CONTENT OF THE IRRIGATION WASTEWATER IS. PLEASE SEE
 SEC. 90-126 FOR AN ITEMIZED LIST OF SANITARY SEWER
 PROHIBITIONS, AND ALSO THE COPIED FBC P SECTIONS BELOW.
 701.4 SEWAGE TREATMENT.
 SEWAGE OR OTHER WASTE FROM A PLUMBING SYSTEM THAT IS
 DELETERIOUS TO SURFACE OR SUBSURFACE WATERS SHALL NOT
 BE DISCHARGED INTO THE GROUND OR INTO ANY WATERWAY
 UNLESS IT HAS FIRST BEEN RENDERED INNOCUOUS THROUGH
 SUBJECTION TO AN APPROVED FORM OF TREATMENT.
 701.5 DAMAGE TO DRAINAGE SYSTEM OR PUBLIC SEWER.
 WASTE DETRIMENTAL TO THE PUBLIC SEWER SYSTEM OR TO THE
 FUNCTIONING OF THE SEWAGE-TREATMENT PLANT SHALL BE
 TREATED AND DISPOSED OF IN ACCORDANCE WITH SECTION 1003
 AS DIRECTED BY THE CODE OFFICIAL.
 703.4 EXISTING BUILDING SEWERS AND DRAINS.
 EXISTING BUILDING SEWERS AND DRAINS SHALL CONNECT WITH
 NEW BUILDING SEWER AND DRAINAGE SYSTEMS ONLY WHERE
 FOUND BY EXAMINATION AND TEST TO CONFORM TO THE NEW
 SYSTEM IN QUALITY OF MATERIAL. THE CODE OFFICIAL SHALL
 NOTIFY THE OWNER TO MAKE THE CHANGES NECESSARY TO
 CONFORM TO THIS CODE.
  
 2) SHEET P1: IT APPEARS THE TRENCHING DIAGRAM DOES NOT
 INCLUDE THE EXTENDED TRENCH REQUIRED FOR THE MOST
 UPSTREAM RELOCATED FLOOR DRAIN- SECTION 107.2.1 WPB.
  
 3) P1 & P2: REFER TO TABLE 909.1 FBC P AND INDICATE THE
 DISTANCE FROM THE RELOCATED FLOOR TRAPS TO THE VENTS.
 PLEASE INDICATE THE SIZES OF THE FD FIXTURE DRAINS.
  
 4) P1 & P2: PLEASE SHOW TRAP PRIMER LINE RUNS AND A
 TRAP PRIMER INSTALLATION DETAIL- SECTION 1002.4.1.1 FBC
 P.
  
 5) P2: PLEASE PROVIDE A DEDICATED FULL OPEN SHUT OFF
 VALVE FOR THE POINT OF USE WATER HEATER- SECTIONS 503.1
 & 606.1(8) FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P-IRRIGATE IRRIGATION REVIEW
Rev No 1 Status N Date 2021-07-06 Cont ID  
Sent By ccole Date 2021-07-06 Time 14:37 Rev Time 0.00
Received By ccole Date 2021-07-06 Time 14:37 Sent To  
Notes
2021-07-06 14:39:27A SEPARATE PERMIT AND PLAN SUMBMITTAL IS REQUIRED FOR
 THE IRRIGATION SYSTEM. PLEASE REFER TO PLUMBING COMMENT
 #1 FOR ADDITIONAL INFORMATION.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-08-23 Cont ID  
Sent By medwards Date 2021-08-23 Time 11:19 Rev Time 0.00
Received By medwards Date 2021-08-23 Time 11:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-08-04 Cont ID  
Sent By medwards Date 2021-08-04 Time 09:13 Rev Time 0.00
Received By medwards Date 2021-08-04 Time 09:13 Sent To  
Notes
2021-08-04 09:14:38SHEET M-3: THE DESIGNER NEEDS TO SUBMIT A DIGITALLY
 SIGNED SHEET.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-06-29 Cont ID  
Sent By medwards Date 2021-06-29 Time 10:45 Rev Time 0.00
Received By medwards Date 2021-06-29 Time 10:45 Sent To  
Notes
2021-06-29 10:45:51PLEASE PROVIDE A M-4 SHEET THAT HAS BEEN DIGITALLY
 SIGNED BY THE ENGINEER.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  