Plan Review Details - Permit 21061027
Plan Review Stops For Permit 21061027
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2021-07-21 Time 09:44 Rev Time 0.00
Received By jwitmer Date 2021-07-21 Time 09:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-03 Cont ID  
Sent By jwitmer Date 2021-07-03 Time 15:15 Rev Time 0.00
Received By jwitmer Date 2021-07-03 Time 14:15 Sent To  
Notes
2021-07-03 15:20:45WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT:21061027
 ADD: 2400 PRESIDENTIAL WAY # 503
 CONT: WINDOW & DOOR DESIGN CENTER
 TEL: 561-348-4805
 E-MAIL: PERMITS@ AANDJPERMITS.COM
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. JULY 03RD/ 2021
 ACTION: DENIED
 1) THE FLOOR PLAN LAYOUT INDICATES THE WORK TO BE
 PREFORMED UNDER THIS PERMIT IS A CORNER UNIT OF A
 HIGHRISE BUILDING. THE WIND LOAD CHART UNDER NOTES
 STATES WHAT IS CONSIDERED AN END ZONE 10% OF THE LEAST
 HORIZONTAL DISTANCE OF THE BUILDING OR 40% OF THE MRH,
 BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DISTANCE
 OR 3 FT. THE CONTRACTOR HAS NOT IDENTIFIED WHAT THE
 LEAST HORIZONTAL DISTANCE IS FOR THE BUILDING. THE
 BUILDING HEIGHT IS APPROXIMATELY 180 FT, MRH. X 0.40=
 72 FEET. THIS WOULD PUT ALL OPENINGS IN WIND ZONE 5.
  
 2) SUBMITTED WIND DESIGN TABLE IS FOR EXPOSURE D. THE
 CORRECT TABLE WOULD BE EXPOSURE C, THIS WOULD DROP BOTH
 THE POSITIVE AND NEGATIVE PRESSURES. THE SILL HEIGHT
 MAYBE ABLE TO BE DROPPED TO 3 ? INCHES (POSITIVE
 PRESSURES FOR SILLS).
  
 3) THE SUBMITTED FLOOR PLAN NEEDS THE CONTRACTOR TO
 TAKE OWNERSHIP OF THE PLAN. CERTIFICATION BY
 CONTRACTOR. 107.3.4.3. THE CONTRACTOR (QUALIFIER) THAT
 CREATED / DREW THE SET OF PLANS WILL NEED TO IDENTIFY
 THEMSELVES AS THE AUTHOR OF THE PLANS. PLEASE PRINT
 YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER FOR THE
 TRADE YOU ARE LICENSED IN AND PLANS DRAWN.
  
 4) THE WIND LOAD CHARTS SUBMITTED APPEAR TO BE PAPER
 AND UPLOADED. THERE IS NO SIGNATURE NOR SEAL ON THE
 WIND LOAD CHART. FLORIDA ADMINISTRATIVE CODE
 61G15-23.005 (3)(C) A DOCUMENT IN THE FILE FOLDER,
 SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE
 OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON
 DIGITALLY SIGNED AND SEALED ENGINEERING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING
 ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES),
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2021-07-21 Time 09:44 Rev Time 0.00
Received By aoliver Date 2021-07-16 Time 12:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-06 Cont ID  
Sent By pvalenti Date 2021-07-06 Time 07:25 Rev Time 0.00
Received By pvalenti Date 2021-06-17 Time 09:54 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2021-07-21 Time 09:44 Rev Time 0.00
Received By jwitmer Date 2021-07-21 Time 09:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2021-07-03 Time 15:15 Rev Time  
Received By   Date 2021-07-03 Time   Sent To  
Notes
2021-07-03 15:19:18THE WIND LOAD CHARTS (ENGINEERING) SUBMITTED APPEAR TO
 BE PAPER AND UPLOADED. THERE IS NO SIGNATURE NOR SEAL
 ON THE WIND LOAD CHART. FLORIDA ADMINISTRATIVE CODE
 61G15-23.005 (3)(C) A DOCUMENT IN THE FILE FOLDER,
 SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE
 OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON
 DIGITALLY SIGNED AND SEALED ENGINEERING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING
 ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES),
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  