Plan Review Stops For Permit 21060968 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-07-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-07-30 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-07-30 |
Time |
16:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-06-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-06-26 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-06-26 |
Time |
08:00 |
Sent To |
|
|
Notes |
2021-06-26 08:10:18 | PLAN REVIEW BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: GENERATOR LOCATION | | | | 1) SURVEY: CORRECT THE 5 FT. GENERATOR EXHAUST | | CLEARANCE TO OPENINGS INTO THE BUILDING. | | 2) A 10 FT. CLEARANCE IS REQUIRED TO MECHANICAL AND | | GRAVITY AIR INTAKES INTO THE BUILDING PER SECTION | | R303.5.1 FBC RES. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-06-25 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-06-25 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-06-25 |
Time |
14:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-07-01 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-07-01 |
Time |
13:01 |
Sent To |
|
|
Notes |
2021-07-01 13:01:46 | 07/01/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-08-19 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-08-19 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-07-19 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-07-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-07-09 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-06-17 |
Time |
09:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-07-01 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-07-01 |
Time |
13:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-07-19 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2021-07-19 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2021-07-19 |
Time |
11:13 |
Sent To |
|
|
Notes |
2021-07-19 11:13:33 | NEW DOCUMENT UPLOADED AND VERIFIED. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-06-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-06-26 |
Time |
08:06 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-06-26 |
Time |
08:00 |
Sent To |
|
|
Notes |
2021-06-26 08:07:50 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC2017 | | | | 1ST REVIEW | | RESULTS: DENIED | | | | RE: GENERATOR PAD ENGINEERING | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-08-18 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-08-18 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-08-18 |
Time |
17:46 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-07-08 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-07-08 |
Time |
19:12 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-07-08 |
Time |
19:12 |
Sent To |
I |
|
Notes |
|
|