Plan Review Details - Permit 21060576
Plan Review Stops For Permit 21060576
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-07-06 Cont ID  
Sent By rmcdouga Date 2021-07-06 Time 10:33 Rev Time 0.00
Received By rmcdouga Date 2021-07-06 Time 10:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-07-26 Cont ID  
Sent By fgiaquin Date 2021-07-26 Time 22:56 Rev Time 0.00
Received By fgiaquin Date 2021-07-26 Time 21:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-06-16 Cont ID  
Sent By ppetty Date 2021-06-16 Time 11:42 Rev Time 0.00
Received By ppetty Date 2021-06-16 Time 10:53 Sent To  
Notes
2021-06-16 11:42:31CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1.PROVISO 680.9-(A) PROVIDE OVERHEAD CLEARANCE OR
 LETTER FRON FPL.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 SINCERELY,
  
 PHIL PETTY
 CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER
  
 561-805-6742
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-26 Cont ID  
Sent By fgiaquin Date 2021-07-26 Time 22:56 Rev Time 0.00
Received By fgiaquin Date 2021-07-20 Time 09:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-06 Cont ID  
Sent By rmcdouga Date 2021-07-06 Time 10:34 Rev Time 0.00
Received By rmcdouga Date 2021-06-10 Time 11:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-07-26 Cont ID  
Sent By lcrespo Date 2021-07-26 Time 12:22 Rev Time 0.00
Received By lcrespo Date 2021-07-26 Time 12:22 Sent To  
Notes
2021-07-26 12:23:2007/26/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-25 Cont ID  
Sent By ccole Date 2021-06-25 Time 16:27 Rev Time 0.00
Received By ccole Date 2021-06-25 Time 15:10 Sent To  
Notes
2021-06-25 16:28:141ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 21060576
 6/25/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS 1 & 3: NO CHLORINATOR IS SPECIFIED HOWEVER
 FRICTION LOSS FOR CHLORINATOR IS INCLUDED IN THE TDH
 CALCULATIONS. PLEASE REVISE THE SCHEDULE OR THE
 CALCULATIONS- ANSI/APSP/ICC 7- 2013 SECS 4.4.9,
 4.4.9.1.
  
 2) SHEET 3: PLEASE PROVIDE THE POOL PUMP CURVE ON THE
 PLAN AND IDENTIFY ON THE POOL PUMP CURVE WHICH CURVE
 KEY IS SPECIFIC TO THE PUMP BEING INSTALLED ON THE
 POOL- ANSI/APSP/ICC 7- 2013 SECS 4.4.9, 4.4.9.1.
  
 3) SHEET 3: PROVIDE A MAIN DRAIN PIPING DETAIL THAT
 INDICATES THE MAKES AND MODELS OF THE DRAINS AND DRAIN
 COVERS AND THE FLOW RATES THROUGH THE COVERS, DRAIN
 PORTS AND THE BRANCH PIPES- ANSI/APSP/ICC 7. PLACE A
 NOTE TO INDICATE THE DRAIN COVERS SHALL CONFORM TO
 ASME/ANSI A112.19.8.
  
 4) SHEET 3: INDICATE HOW THE POOL WILL BE FILLED.
 CLARIFY IF TO IT WILL BE FILLED FROM A HOSE BIB OR
 CONNECTION TO THE MAIN POTABLE WATER SERVICE- SECTION
 R4501.9 FBC RES. PLEASE NOTE THAT BACKFLOW PREVENTERS
 INSTALLED UNDER SEPARATE PERMIT WILL BE REQUIRED FOR
 CONNECTION TO THE POTABLE WATER SERVICE- SECTION
 P2902.1 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-07-26 Cont ID  
Sent By lcrespo Date 2021-07-26 Time 12:23 Rev Time 0.00
Received By lcrespo Date 2021-07-26 Time 12:22 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-07-06 Cont ID  
Sent By rmcdouga Date 2021-07-06 Time 10:34 Rev Time 0.00
Received By rmcdouga Date 2021-07-06 Time 10:15 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-07-01 Cont ID  
Sent By kalexand Date 2021-07-01 Time 10:24 Rev Time 0.00
Received By kalexand Date 2021-07-01 Time 10:24 Sent To I
Notes
***NONE***