Plan Review Details - Permit 21060073
Plan Review Stops For Permit 21060073
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-06-23 Cont ID  
Sent By rmcphers Date 2021-06-23 Time 13:02 Rev Time 0.00
Received By rmcphers Date 2021-06-23 Time 13:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-08-02 Cont ID  
Sent By jleahy Date 2021-08-02 Time 12:27 Rev Time 0.00
Received By jleahy Date 2021-08-02 Time 11:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-06-21 Cont ID  
Sent By jleahy Date 2021-06-21 Time 12:22 Rev Time 0.00
Received By jleahy Date 2021-06-21 Time 12:11 Sent To  
Notes
2021-06-21 13:03:12ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 PANEL IN CABANA IS IN A CLOSET. NOT IN VICINITY OF
 EASILY IGNITIBLE MATERIAL. OVERCURRENT DEVICES S HALL
 NOT BE LOCATED IN THE VICINITY OF EASILY IGNITIBLE
 MATERIAL, SUCH AS IN CLOTHES CLOSETS 240.24(D)
  
 PANEL IN CABANA NEEDS A GROUNDING ELECTRODE SYSTEM
 250.32
  
 PANEL "P" NEEDS A MAIN BREAKER PER 225.33 NO MORE THAN
 6 SETS OF BREAKERS IN A PANEL REMOTE FROM BUILDING.
  
 225.33 MAXIMUM NUMBER OF DISCONNECTS (A) GENERAL. TH E
 DISCONNECTING MEANS FOR EACH SUPPLY PERMITTED BY 225.30
 SHALL CONSIST OF NOT MORE THAN SIX SWITCHES OR SIX
 CIRCUIT BREAKERS MOUNTED IN A SINGLE ENCLOSURE, IN A
 GROUP OF SEPARATE ENCLOSURES, OR IN OR ON A SWITCHBOARD
 OR SWITCHGEAR. THERE SHALL BE NO MORE THAN SIX
 DISCONNECTS PER SUPPLY GROUPED IN ANY ONE LOCATION

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2021-07-09 Cont ID  
Sent By jleahy Date 2021-07-09 Time 15:01 Rev Time 0.00
Received By jleahy Date 2021-07-09 Time 15:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-08-02 Cont ID  
Sent By jleahy Date 2021-08-02 Time 12:27 Rev Time 0.00
Received By jleahy Date 2021-07-27 Time 10:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-09 Cont ID  
Sent By jleahy Date 2021-07-09 Time 15:02 Rev Time 0.00
Received By jleahy Date 2021-06-11 Time 07:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-06-18 Cont ID  
Sent By medwards Date 2021-06-18 Time 15:08 Rev Time 0.00
Received By hmoser Date 2021-06-18 Time 14:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-06-24 Cont ID  
Sent By lcrespo Date 2021-06-24 Time 09:06 Rev Time 0.00
Received By lcrespo Date 2021-06-24 Time 08:53 Sent To  
Notes
2021-06-24 12:05:4106/24/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-08-02 Cont ID  
Sent By jleahy Date 2021-08-02 Time 12:27 Rev Time 0.00
Received By jleahy Date 2021-08-02 Time 12:27 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-06-23 Cont ID  
Sent By rmcphers Date 2021-06-23 Time 13:07 Rev Time 0.00
Received By rmcphers Date 2021-06-23 Time 13:07 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-07-06 Cont ID  
Sent By awooten Date 2021-07-06 Time   Rev Time  
Received By awooten Date 2021-07-06 Time   Sent To  
Notes
***NONE***