Plan Review Details - Permit 21051622
Plan Review Stops For Permit 21051622
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-07-19 Cont ID  
Sent By rmcdouga Date 2021-07-19 Time 15:02 Rev Time 0.00
Received By rmcdouga Date 2021-07-19 Time 15:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-13 Cont ID  
Sent By rmcdouga Date 2021-07-13 Time 14:39 Rev Time 0.00
Received By rmcdouga Date 2021-07-13 Time 14:39 Sent To  
Notes
2021-07-13 14:41:13PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT A SURVEY THAT SHOWS THE PROPOSED LOCATION OF
 THE POOL AND EQUIPMENT. FBC 107.2.1
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-07-26 Cont ID  
Sent By ppetty Date 2021-07-26 Time 08:35 Rev Time 0.00
Received By ppetty Date 2021-07-26 Time 08:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-06-21 Cont ID  
Sent By ppetty Date 2021-06-21 Time 14:31 Rev Time 0.00
Received By ppetty Date 2021-06-21 Time 14:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-26 Cont ID  
Sent By ppetty Date 2021-07-26 Time 08:36 Rev Time 0.00
Received By ppetty Date 2021-07-15 Time 08:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-13 Cont ID  
Sent By rmcdouga Date 2021-07-13 Time 14:41 Rev Time 0.00
Received By rmcdouga Date 2021-06-15 Time 07:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-07-16 Cont ID  
Sent By lcrespo Date 2021-07-16 Time 13:12 Rev Time 0.00
Received By lcrespo Date 2021-07-16 Time 13:12 Sent To  
Notes
2021-07-16 13:13:0107/16/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-30 Cont ID  
Sent By lcrespo Date 2021-06-30 Time 13:26 Rev Time 0.00
Received By lcrespo Date 2021-06-30 Time 13:25 Sent To  
Notes
2021-06-30 13:53:4106/30/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE SHOW ON THE POOL PUMP CURVE. THIS IS NEEDED
 TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE TDH
 CALCULATIONS PER THE ANSI/APSP/ICC 7 - 2013 SECS.
 4.4.9, 4.4.9.1. INDICATE ON THE PUMP CURVE WHICH CURVE
 KEY IS FOR THE PUMP BEING INSTALLED ON THIS SYSTEM PER
 THE WPB AMEND. TO FBC SEC. 107.2.1.
  
 2. PLEASE SUBMIT THE MANUFACTURER'S SPECIFICATIONS FOR
 THE PUMP, HEAT PUMP, FILTER AND CHLORINATOR IF USED PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 3. ON-PAGE 3-3, THE EQUIPMENT LAYOUT HAS THREE F'S AND
 THERE IS NO G OR H. PLEASE CLARIFY PER THE WPB
 AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 4. HEAT PUMP POOL HEATERS SHALL HAVE A MINIMUM COP OF
 4.0 WHEN TESTED IN ACCORDANCE WITH AHRI 1160, TABLE 2,
 STANDARD RATING CONDITIONS ? LOW AIR TEMPERATURE. A
 TEST REPORT FROM AN INDEPENDENT LABORATORY IS REQUIRED
 TO VERIFY PROCEDURE COMPLIANCE PER THE 2020 FBC-ENERGY
 SEC. R 403.10.5. PLEASE PROVIDE DOCUMENTATION.
  
 5. A CONTAINMENT REDUCED PRINCIPAL ZONE BACKFLOW DEVICE
 WILL BE REQUIRED AT THE WATER METER BY A LICENSED
 CONTRACTOR WITH A SEPARATE PERMIT AND CERTIFIED BY THE
 CITY OF WEST PALM BEACH UTILITY DEPARTMENT PER THE
 CROSS CONNECTION CONTROL MANUAL PAGE 11 (C). THIS IS
 DUE TO THE AUTOFILL ON THE POOL, WHICH WILL REQUIRE A
 BACKFLOW DEVICE (P.V.B. ISOLATION), AND IT WILL BE
 REQUIRED TO BE CERTIFIED BY A LICENSED BACKFLOW
 CONTRACTOR. A REPORT MUST BE FILLED OUT FOR THE P.V.B.
 AND WILL NEED TO BE WITH THE PERMIT AT THE FINAL. THE
 INSPECTOR WILL TAKE THE CERTIFICATION FOR CITY RECORDS.
 THESE TWO BACKFLOWS CAN BE COMBINED IN THE SAME PERMIT.
  
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-07-26 Cont ID  
Sent By ppetty Date 2021-07-26 Time 08:35 Rev Time 0.00
Received By ppetty Date 2021-07-26 Time 08:35 Sent To  
Notes
2021-07-19 15:42:09DIGITALLY SIGNED FILES UNDER SIGNATURES FOLDER

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-06-16 Cont ID  
Sent By medwards Date 2021-06-16 Time 15:17 Rev Time 0.00
Received By medwards Date 2021-06-16 Time 15:16 Sent To  
Notes
2021-06-16 15:18:28ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO
 STORAGE.ME

Review Stop Z ZONING
Rev No 2 Status P Date 2021-07-23 Cont ID  
Sent By jroach Date 2021-07-23 Time 12:04 Rev Time 0.00
Received By jroach Date 2021-07-23 Time 12:04 Sent To  
Notes
2021-07-23 12:04:41PROVISOS:
  
 1. ALL POOL EQUIPMENT SHALL BE A MINIMUM OF ONE (1)
 FOOT FROM THE SIDE PROPERTY LINE.
  
 2. POOL SHALL BE ENCLOSED BY A PERMANENT FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE
 RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED
 (?BABY FENCE? DOES NOT MEET THIS REQUIREMENT). BARRIERS
 OR FENCES SHALL BE AT LEAST 4 FEET IN HEIGHT ABOVE
 GRADE.
  
 3. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH
 A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING
 GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES
 PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE.
  
 4. PATIO OR PAVED AREA ADJACENT TO OR SURROUNDING THE
 POOL SHALL BE DESIGNED TO DRAIN AWAY FROM THE POOL, BUT
 NOT ONTO ADJACENT PROPERTIES.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG

Review Stop Z ZONING
Rev No 1 Status F Date 2021-07-03 Cont ID  
Sent By jroach Date 2021-07-03 Time 12:55 Rev Time 0.00
Received By jroach Date 2021-07-03 Time 12:55 Sent To  
Notes
2021-07-03 12:56:03ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 07.03.2021
 PERMIT NO.: 21051622
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. A SURVEY SHALL BE PROVIDED FOR THE SUBJECT PROPERTY
 AND SHALL INDICATION THE LOCATION OF THE POOL AND ALL
 EQUIPMENT. DIMENSIONS SHALL BE PROVIDED FROM ALL
 IMPROVEMENTS TO THE SURROUNDING PROPERTY LINES.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved