 |
Plan Review Details - Permit 21051188
Plan Review Stops For Permit 21051188 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2021-05-28 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-05-28 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-05-28 |
Time |
10:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
N |
Date |
2021-06-01 |
|
|
Cont ID |
|
Sent By |
scwelter |
Date |
2021-06-01 |
Time |
15:22 |
Rev Time |
|
Received By |
scwelter |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-06-01 15:23:15 | N/A NON-PROFIT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-29 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-29 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-10-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-28 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-28 |
Time |
15:47 |
Sent To |
|
|
Notes |
2021-10-28 16:12:56 | NEW 2 STORY OFFICE/ CAFE BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | | 1) DRAWING A0.01 DOES NOT HAVE A LIST OF DEFERRED ITEMS | | (THE REVISION DATE ON THE DRAWING IS (7/29/21)) - | | PLEASE PROVIDE DETAILS FOR THE ROOF TOP CANOPY, | | ALUMINUM CANOPY, GUARD RAILS, TILT WALL PANELS, FAUX | | WOOD ROOF DECK, SOLAR PANELS, ROOF TOP EQUIPMENT | | SCREENING CLADDING ETC - OR LIST THESE ITEMS ON THE | | DRAWINGS AS TO BE DEFERRED PER 107.3.4.1 | | | | 2) SEPARATE PERMIT WILL BE REQUIRED FOR PARKING LOT, | | DUMPSTER ENCLOSURE, SIGNS, GENERATOR, FENCE. - PLEASE | | ACKNOWLEDGE THIS. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-09-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-09-14 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-09-14 |
Time |
14:15 |
Sent To |
|
|
Notes |
2021-09-14 14:29:58 | NEW 2 STORY OFFICE/ CAFE BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) REVISED DRAWINGS LOADED TO PROJECTDOX SHOULD BE | | NAMED THE SAME IN PROJECTDOX AS THE PREVIOUS DRAWING SO | | THAT THE NEW REVISED DRAWING WILL OVERLAP AND BECOME | | (V2, 3, 4 ETC) - PLEASE CONTACT THE | | [email protected] TO HELP YOU WITH THE CORRECT | | UPLOADING TO PROJECTDOX. SAVES TIME FOR THE PLAN REVIEW | | AND PREVENTS OLD DRAWINGS FROM GETTING APPROVED. | | 2) PLEASE PROVIDE COMPLETE COPIES OF THE PRODUCT | | APPROVALS FOR THE EXTERIOR WINDOWS, DOORS, ROOFING | | SYSTEMS, ETC. - ALL PRODUCT APPROVALS NEED TO BE | | REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER | | OF RECORD OR BE LISTED ON THE DRAWINGS BY THE PRODUCT | | APPROVAL NUMBER. FBC WPB 107.2.1 | | 3) PLEASE SHOW THE RESTROOM WALL FINISH TO COMPLY WITH | | FBC 1210.2.2 (DRYWALL IS NOT CONSIDERED A HARD | | SURFACE). | | 4) PLEASE PROVIDE DETAILS FOR THE ROOF TOP CANOPY, | | ALUMINUM CANOPY, GUARD RAILS, TILT WALL PANELS, FAUX | | WOOD ROOF DECK, SOLAR PANELS, ROOF TOP EQUIPMENT | | SCREENING ETC - PLEASE LIST THESE ITEMS ON THE DRAWINGS | | AS TO BE DEFERRED PER 107.3.4.1 | | 5) SEPARATE PERMIT WILL BE REQUIRED FOR PARKING LOT, | | DUMPSTER ENCLOSURE, SIGNS, GENERATOR, FENCE. - PLEASE | | ACKNOWLEDGE THIS. | | 6) DRAWINGS A4.04 AND A4.03 ACCESSIBLE RESTROOM FLOOR | | PLAN NEEDS TO SHOW THE GRAB BARS. | | 7) 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR | | DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE | | IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. | | THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED | | UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN | | APPROVED BY THE BUILDING OFFICIAL. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-07-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-07-15 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-07-14 |
Time |
12:28 |
Sent To |
|
|
Notes |
2021-07-15 12:18:57 | NEW 2 STORY OFFICE/ CAFE BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) OCCUPANCY CLASSIFICATION SHOULD BE SHOWN AS MIXED | | B/A2 FBC CHAPTER 3 | | 2) PLEASE SHOW THE ACCESSIBLE PATH AND SEATING IN THE | | CAFE AND EXTERIOR GARDEN AREA TO COMPLY WITH FBC | | A206.2.2 AND 226.1 | | 3) PLEASE PROVIDE COMPLETE COPIES OF THE PRODUCT | | APPROVALS FOR THE EXTERIOR WINDOWS, DOORS, ROOFING | | SYSTEMS, ETC. - ALL PRODUCT APPROVALS NEED TO BE | | REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER | | OF RECORD OR BE LISTED ON THE DRAWINGS BY THE PRODUCT | | APPROVAL NUMBER. FBC WPB 107.2.1 | | 4) PLEASE SHOW THE RESTROOM WALL FINISH TO COMPLY WITH | | FBC 1210.2.2 (DRYWALL IS NOT CONSIDERED A HARD | | SURFACE). | | 5) DRAWING A4.04 RESTROOM SHOWS A PARTITION IN FRONT OF | | THE TOILET ROOM AND NO DOOR - PLEASE SHOW DOOR | | LOCATION. | | 6) DRAWING A4.11 - LEVEL 1 ENLARGED PLAN @ WEST STAIR - | | NEEDS TO SHOW HAND RAILS ON BOTH SIDES OF THE STAIRS - | | FBC 1011.11 | | 7) DRAWING A1.01 - SITE DATA - SHOULD SAY 4 ACCESSIBLE | | PARKING SPACES. FBC ACCESSIBILITY TABLE 208.2 | | 8) DRAWING A5.02 - METAL PAN STAIR- SHOULD SHOW THE | | BOTTOM SLOPING HAND RAIL TO CONTINUE 11" PER FBC 1014.6 | | 9) THE LIFE SAFETY PLANS SHOW FIRE WALLS AT STAIRWAYS/ | | ELEVATOR AND "COMMUNITY BOARD RM" THE WALL DESIGNATIONS | | ON THE CONSTRUCTION PLANS DOES NOT SHOW FIRE RATED | | WALLS - PLEASE CLARIFY. | | 10) DRAWING S-0.00 SHOWS WIND DATA - EXPOSURE "C" USED | | - BEING NEAR THE LAKE MANGONIA IT APPEARS THAT EXPOSURE | | "D" SHOULD BE USED PER FBC 1609.4.3 | | 11) PLEASE SHOW THAT TERMITE PROTECTION IS REQUIRED PER | | FBC 1816 | | 12) PLEASE PROVIDE DETAILS FOR THE ROOF TOP CANOPY, | | ALUMINUM CANOPY, GUARD RAILS, TILT WALL PANELS FAUX | | WOOD ROOF DECK. | | 13) SEPARATE PERMIT WILL BE REQUIRED FOR PARKING LOT, | | DUMPSTER ENCLOSURE, SIGNS, GENERATOR, FENCE. | | 14) 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR | | DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE | | IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. | | THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED | | UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN | | APPROVED BY THE BUILDING OFFICIAL. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2021-11-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-11-05 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-11-05 |
Time |
15:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-09-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-09-23 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-09-23 |
Time |
16:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-06-24 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-06-24 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-06-24 |
Time |
16:18 |
Sent To |
|
|
Notes |
2021-06-24 16:52:51 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) FAULT CURRENT CALCULATION REQUIRED FOR SERVICE AND | | PANELS PER 110.9, 110.10, 110.24 | | | | 2) KITCHEN AND CAFE BOTH REQUIRE ALL 15 AND 20 AMPERE | | RECEPTACLES TO BE GFCI PROTECTED 210,8(B)(2) | | | | 210.8(B) OTHER THAN DWELLING UNITS. ALL SINGLE-PHASE | | RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 50 | | AMPERES OR LESS AND THREEPHASE RECEPTACLES RATED 150 | | VOLTS TO GROUND OR LESS, 100 AMPERES OR LESS INSTALLED | | IN THE FOLLOWING LOCATIONS SHALL HAVE GROUND-FAULT | | CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. (2) | | KITCHENS | | | | 3) BOARD ROOM AND EDUCATION/FLEX ROOMS ON SECOND FLOOR | | NEEDS MORE THAN ONE FLOOR OUTLET PER 210.71 | | | | 210.71 MEETING ROOMS. (A) GENERAL. EACH MEETING ROOM OF | | NOT MORE THAN 93 M2 (1000 FT2) IN OTHER THAN DWELLING | | UNITS SHALL HAVE OUTLETS FOR NONLOCKING-TYPE, 125-VOLT, | | 15- OR 20-AMPERE RECEPTACLES. THE OUTLETS SHALL BE | | INSTALLED IN ACCORDANCE WITH 210.71(B). WHERE A ROOM OR | | SPACE IS PROVIDED WITH MOVABLE PARTITION(S), EACH ROOM | | SIZE SHALL BE DETERMINED WITH THE PARTITION IN THE | | POSITION THAT RESULTS IN THE SMALLEST SIZE MEETING | | ROOM. | | | | 4) OUTLETS IN COMMON AREAS SHALL BE TAMPER RESISTANT | | TYPE PER 406.12 | | | | 406.12 TAMPER-RESISTANT RECEPTACLES. ALL 15- AND | | 20-AMPERE, 125- AND 250-VOLT NONLOCKING-TYPE | | RECEPTACLES IN THE AREAS SPECIFIED IN 406.12(1) THROUGH | | (7) SHALL BE LISTED TAMPERRESISTANT RECEPTACLES. (1) | | DWELLING UNITS IN ALL AREAS SPECIFIED IN 210.52 AND | | 550.13 (2) GUEST ROOMS AND GUEST SUITES OF HOTELS AND | | MOTELS (3) CHILD CARE FACILITIES (4) PRESCHOOLS AND | | ELEMENTARY EDUCATION FACILITIES (5) BUSINESS OFFICES, | | CORRIDORS, WAITING ROOMS AND THE LIKE IN CLINICS, | | MEDICAL AND DENTAL OFFICES AND OUTPATIENT FACILITIES | | (6) SUBSET OF ASSEMBLY OCCUPANCIES DESCRIBED IN 518.2 | | TO INCLUDE PLACES OF WAITING TRANSPORTATION, | | GYMNASIUMS, SKATING RINKS, AND AUDITORIUMS (7) | | DORMITORIES |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2021-11-29 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2021-11-29 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
F |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2021-10-15 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2021-10-15 |
Time |
|
Sent To |
|
|
Notes |
2021-10-15 09:06:24 | UNDER REVIEW - FORMAL ENGINEERING SUBMITTAL E21070029. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2021-08-31 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2021-08-31 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2021-08-31 |
Time |
|
Sent To |
|
|
Notes |
2021-08-31 14:10:08 | UNDER REVIEW - FORMAL ENGINEERING SUBMITTAL E21070029. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2021-06-02 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2021-06-02 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2021-06-02 |
Time |
|
Sent To |
|
|
Notes |
2021-06-02 12:53:14 | PLEASE SUBMIT A FORMAL ENGINEERING SUBMITTAL INCLUDING | | COST ESTIMATE AND STORMWATER CALCULATIONS TO: | | | | MANNY GONZALEZ | | SENIOR ENGINEERING PROJECT COORDINATOR | | ENGINEERING SERVICES DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | MOBILE: (561) 644-7301 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2021-11-17 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-11-17 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-11-17 |
Time |
13:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-10-15 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-10-15 |
Time |
10:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2021-08-16 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-08-16 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-08-16 |
Time |
10:33 |
Sent To |
|
|
Notes |
2021-08-16 10:38:14 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) PROVIDING A STATEMENT OF SHOP DRAWINGS WILL BE | | PROVIDED FOR THE FIRE SPRINKLER SYSTEM DOES NOT MEET | | THE REQUIRMENTS OF F.A.C. 61G. | | | | A DETAILED NARRATIVE OR PLAN SET DRAWINGS OF THE FIRE | | SPRINKLER DESIGN SHALL BE SUBMITTED WITH THIS MASTER | | PERMIT. | | | | THE EOR SHALL SUBMIT PER THE REQUIRERMENTS OF THE | | F.A.C. | | | | SHOULD THE EOR DEFER TO A LOCAL CONTRACTOR, THE EOR | | SHALL PROVIDE THE DEFERFAL IN WRITING; HOWEVER, THE | | CONTRATOR SHALL THEN BE RESPOSIBLE TO SUBMIT 61G | | DOCUMENTS WITH THIS MASTER. | | | | SHOP DRAWINGS CAN THEN BE SUBMITTED AT A LATER TIME. | | | | THE REQUIREMENTS ARE AGAIN NOTED BELOW. | | | | 61G15-32.003 COMMON REQUIREMENTS TO ALL FIRE PROTECTION | | ENGINEERING | | DOCUMENTS. | | (1) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | SHALL PROVIDE THE ENGINEERING REQUIREMENTS TO BE USED | | IN THE PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | DOCUMENTS AND TO INDICATE THE NATURE AND SCOPE OF THE | | WORK, AND TO DESCRIBE, DETAIL, DIMENSION, LABEL AND | | DEFINE THE FIRE PROTECTION COMPONENTS, SYSTEM(S), | | MATERIALS, ASSEMBLIES, EQUIPMENT AND ITS STRUCTURAL AND | | UTILITY SUPPORT SYSTEM(S), INSOFAR AS THEY INVOLVE THE | | SAFEGUARDING OF LIFE, HEALTH OR PROPERTY. | | (2) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | SHALL SPECIFY THE APPLICABLE REQUIREMENTS FOR THE | | ACCEPTANCE TESTING OF THE FIRE PROTECTION SYSTEM AND | | COMPONENTS, WHICH SHALL BE BASED UPON APPLICABLE CODES | | AND STANDARDS, WHERE AVAILABLE. | | (3) THE OCCUPANCY OF THE AREA OR DESCRIPTION OF A | | SPECIFIC HAZARD BEING PROTECTED BY THE FIRE PROTECTION | | SYSTEM(S) SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENTS. | | (4) THE APPLICABLE CODE AND STANDARD TO BE USED IN THE | | PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | DOCUMENTS SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENTS. WHEN CODES AND STANDARDS ARE NOT | | AVAILABLE OR APPLICABLE, AND SAID LAYOUT DOCUMENTS ARE | | TO BE BASED ON ENGINEERING JUDGMENT, ANY REASONS AND | | ASSUMPTIONS MADE TO DEVELOP THE FIRE PROTECTION CONCEPT | | SHALL BE IDENTIFIED ON THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENTS. | | (5) STRUCTURAL SUPPORT AND STRUCTURAL OPENINGS REQUIRED | | BY THE FIRE PROTECTION SYSTEM SHALL BE SHOWN ON THE | | FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS AND SHALL | | BE REFERENCED ON STRUCTURAL ENGINEERING DOCUMENTS. | | (6) WHEN LAYOUT DOCUMENTS CONTAIN MATERIAL DEVIATION | | FROM THE ENGINEER OF RECORD'S FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENT, SUCH LAYOUT DOCUMENTS ARE NOT | | COMPLIANT UNLESS THEY ARE ACCOMPANIED BY REVISED | | ENGINEERING DOCUMENTS MADE AND SEALED BY THE ENGINEER | | OF RECORD FOR THE FIRE PROTECTION SYSTEM. | | (7) REQUIREMENTS FOR ACTIVATION CONTROL SYSTEMS, | | SEQUENCE, OPERATING PARAMETERS, INTERLOCKS, SAFETY | | RELATED DEVICES, INDICATORS AND ALARMS, SHALL BE SHOWN | | ON THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS, | | UNLESS SHOWN ON OTHER RELATED DOCUMENTS. | | (8) ANY INFORMATION DEEMED APPROPRIATE BY THE ENGINEER | | OF RECORD TO ASSIST THE AUTHORITY HAVING JURISDICTION | | IN UNDERSTANDING THE OWNER?S INTENDED USE AND PROPOSED | | PROTECTION OF THE BUILDING OR FACILITY AND TO PROVIDE | | SUFFICIENT DIRECTION TO THE INSTALLATION CONTRACTOR OR | | OTHER INTERESTED PARTIES REGARDING THE LAYOUT OF THE | | SYSTEM(S), SHALL BE INCLUDED IN THE FIRE PROTECTION | | SYSTEM ENGINEERING DOCUMENTS. | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.003, AMENDED | | 4-2-2000, 6-26-01 | | | | 61G15-32.004 DESIGN OF WATER BASED FIRE PROTECTION | | SYSTEMS. | | (1) WATER BASED FIRE PROTECTION SYSTEMS INCLUDE, BUT | | ARE NOT LIMITED TO, AUTOMATIC SPRINKLER SYSTEMS OF WET, | | DRY, FINE WATER SPRAY (MIST), MANUAL, AND DELUGE VALVE | | CONTROLLED TYPES, PUMPING SYSTEMS, STANDPIPES, FIRE | | WATER MAINS AND DEDICATED FIRE PROTECTION WATER | | SOURCES. | | (2) TO ENSURE MINIMUM DESIGN QUALITY IN FIRE PROTECTION | | SYSTEM ENGINEERING DOCUMENTS, SAID DOCUMENTS SHALL | | INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION WHEN | | APPLICABLE: | | (A) THE POINT OF SERVICE FOR THE FIRE PROTECTION WATER | | SUPPLY AS DEFINED BY 633.021(18) F.S. | | (B) APPLICABLE NFPA STANDARD TO BE APPLIED, OR IN THE | | CASE WHERE NO SUCH STANDARD EXISTS, THE ENGINEERING | | STUDY, JUDGMENTS, AND/OR PERFORMANCE BASED ANALYSIS AND | | CONCLUSIONS. | | (C) CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | AREA. | | (D) DESIGN APPROACH, WHICH INCLUDES SYSTEM TYPE, | | DENSITIES, DEVICE TEMPERATURE RATING, AND SPACING FOR | | EACH SEPARATE 42 HAZARD OCCUPANCY. | | (E) CHARACTERISTICS OF WATER SUPPLY TO BE USED, SUCH AS | | MAIN SIZE AND LOCATION, WHETHER IT IS DEAD-END OR | | CIRCULATING; AND IF DEAD-END, THE DISTANCE TO THE | | NEAREST CIRCULATING MAIN, AS WELL AS ITS MINIMUM | | DURATION AND RELIABILITY FOR THE MOST HYDRAULICALLY | | DEMANDING DESIGN AREA. | | (F) WHEN PRIVATE OR PUBLIC WATER SUPPLIES ARE USED, THE | | FLOW TEST DATA, INCLUDING DATE AND TIME OF TEST, WHO | | CONDUCTED TEST OR SUPPLIED INFORMATION, TEST ELEVATION, | | STATIC GAUGE PRESSURE AT NO FLOW, FLOW RATE WITH | | RESIDUAL GAUGE PRESSURE, HYDRANT BUTT COEFFICIENT, AND | | LOCATION OF TEST IN RELATION TO THE HYDRAULIC POINT OF | | SERVICE. | | (G) VALVING AND ALARM REQUIREMENTS TO MINIMIZE | | POTENTIAL FOR IMPAIRMENTS AND UNRECOGNIZED FLOW OF | | WATER. | | (H) MICROBIAL INDUCED CORROSION (MIC). THE ENGINEER OF | | RECORD SHALL MAKE REASONABLE EFFORTS TO IDENTIFY WATER | | SUPPLIES THAT COULD LEAD TO MICROBIAL INDUCED CORROSION | | (MIC). SUCH EFFORTS MAY CONSIST OF DISCUSSIONS WITH THE | | LOCAL WATER PURVEYOR AND/OR FIRE OFFICIAL, FAMILIARITY | | WITH CONDITIONS IN THE LOCAL AREA, OR LABORATORY | | TESTING OF WATER SUPPLIES. WHEN CONDITIONS ARE FOUND | | THAT MAY RESULT IN MIC CONTAMINATION OF THE FIRE | | PROTECTION PIPING, THE ENGINEER SHALL DESIGN CORRECTIVE | | MEASURES. | | (I) BACKFLOW PREVENTION AND METERING SPECIFICATIONS AND | | DETAILS TO MEET LOCAL WATER PURVEYOR REQUIREMENTS | | INCLUDING MAXIMUM ALLOWABLE PRESSURE DROP. | | (J) QUALITY AND PERFORMANCE SPECIFICATIONS OF ALL YARD | | AND INTERIOR FIRE PROTECTION COMPONENTS. | | (3) CONTRACTOR SUBMITTALS WHICH DEVIATE FROM THE ABOVE | | MINIMUM DESIGN PARAMETERS SHALL BE CONSIDERED MATERIAL | | DEVIATIONS AND REQUIRE SUPPLEMENTAL ENGINEERING | | APPROVAL AND DOCUMENTATION. | | (4) IN THE EVENT THE ENGINEER OF RECORD PROVIDES MORE | | INFORMATION AND DIRECTION THAN IS ESTABLISHED ABOVE, HE | | OR SHE SHALL BE HELD RESPONSIBLE FOR THE TECHNICAL | | ACCURACY OF THE WORK IN ACCORDANCE WITH APPLICABLE | | CODES, STANDARDS, AND SOUND ENGINEERING PRINCIPLES. | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.004, AMENDED | | 4-2-2000, 6-26-01, 7-12-05 | | FAC 61G15-32.002 DEFINES THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENT (5) AS WELL AS THE FIRE PROTECTION | | SYSTEM LAYOUT DOCUMENT (6). 61G15-32.003 OUTLINES THE | | COMMON REQUIREMENTS TO ALL FIRE PROTECTIONS ENGINEERING | | DOCUMENTS WITH 32.004 (2) (A-J) OUTLINING THE MINIMUM | | INFORMATION TO BE PROVIDED ON FIRE PROTECTION | | ENGINEERING DOCUMENTS FOR WATER BASED SYSTEMS. AS | | STATED IN THE DEFINITIONS, THE CONTRACTOR IS TO DEVELOP | | THE LAYOUT DOCUMENTS BASED ON THE DESIGN CRITERIA | | PROVIDED IN THE FIRE PROTECTION ENGINEERING DOCUMENTS | | BY THE ENGINEER OF RECORD FOR THE FIRE SPRINKLER | | SYSTEM. THE FIRE PROTECTION SYSTEM ENGINEERING | | DOCUMENTS ARE SUBMITTED FOR THE MASTER PERMIT (BUILDING | | PERMIT PER FBC) AND THE LAYOUT DOCUMENTS ARE SUBMITTED | | FOR THE FIRE SPRINKLER INSTALLATION PERMIT. | | | | PLEASE PROVIDE FOR THE REQUIEMENTS EITHER IN DRAWING OR | | NARRATIVE FORM SIGNED AND SEALED WITH THIS MASTER | | PERMIT. | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2021-06-16 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-06-16 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-06-11 |
Time |
15:21 |
Sent To |
|
|
Notes |
2021-06-11 15:25:39 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS AN INDICATION ON THE COVER SHEET THAT THIS | | BUILDING IS FULLY SPRINKLED ; HOWEVER, THERE ARE NO | | REQUIRED DOCUMENTS OF THE FIRE SPRINKLER DESIGN PER | | F.A.C. 61G | | | | 61G15-32.003 COMMON REQUIREMENTS TO ALL FIRE PROTECTION | | ENGINEERING | | DOCUMENTS. | | (1) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | SHALL PROVIDE THE ENGINEERING REQUIREMENTS TO BE USED | | IN THE PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | DOCUMENTS AND TO INDICATE THE NATURE AND SCOPE OF THE | | WORK, AND TO DESCRIBE, DETAIL, DIMENSION, LABEL AND | | DEFINE THE FIRE PROTECTION COMPONENTS, SYSTEM(S), | | MATERIALS, ASSEMBLIES, EQUIPMENT AND ITS STRUCTURAL AND | | UTILITY SUPPORT SYSTEM(S), INSOFAR AS THEY INVOLVE THE | | SAFEGUARDING OF LIFE, HEALTH OR PROPERTY. | | (2) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | SHALL SPECIFY THE APPLICABLE REQUIREMENTS FOR THE | | ACCEPTANCE TESTING OF THE FIRE PROTECTION SYSTEM AND | | COMPONENTS, WHICH SHALL BE BASED UPON APPLICABLE CODES | | AND STANDARDS, WHERE AVAILABLE. | | (3) THE OCCUPANCY OF THE AREA OR DESCRIPTION OF A | | SPECIFIC HAZARD BEING PROTECTED BY THE FIRE PROTECTION | | SYSTEM(S) SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENTS. | | (4) THE APPLICABLE CODE AND STANDARD TO BE USED IN THE | | PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | DOCUMENTS SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENTS. WHEN CODES AND STANDARDS ARE NOT | | AVAILABLE OR APPLICABLE, AND SAID LAYOUT DOCUMENTS ARE | | TO BE BASED ON ENGINEERING JUDGMENT, ANY REASONS AND | | ASSUMPTIONS MADE TO DEVELOP THE FIRE PROTECTION CONCEPT | | SHALL BE IDENTIFIED ON THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENTS. | | (5) STRUCTURAL SUPPORT AND STRUCTURAL OPENINGS REQUIRED | | BY THE FIRE PROTECTION SYSTEM SHALL BE SHOWN ON THE | | FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS AND SHALL | | BE REFERENCED ON STRUCTURAL ENGINEERING DOCUMENTS. | | (6) WHEN LAYOUT DOCUMENTS CONTAIN MATERIAL DEVIATION | | FROM THE ENGINEER OF RECORD'S FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENT, SUCH LAYOUT DOCUMENTS ARE NOT | | COMPLIANT UNLESS THEY ARE ACCOMPANIED BY REVISED | | ENGINEERING DOCUMENTS MADE AND SEALED BY THE ENGINEER | | OF RECORD FOR THE FIRE PROTECTION SYSTEM. | | (7) REQUIREMENTS FOR ACTIVATION CONTROL SYSTEMS, | | SEQUENCE, OPERATING PARAMETERS, INTERLOCKS, SAFETY | | RELATED DEVICES, INDICATORS AND ALARMS, SHALL BE SHOWN | | ON THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS, | | UNLESS SHOWN ON OTHER RELATED DOCUMENTS. | | (8) ANY INFORMATION DEEMED APPROPRIATE BY THE ENGINEER | | OF RECORD TO ASSIST THE AUTHORITY HAVING JURISDICTION | | IN UNDERSTANDING THE OWNER?S INTENDED USE AND PROPOSED | | PROTECTION OF THE BUILDING OR FACILITY AND TO PROVIDE | | SUFFICIENT DIRECTION TO THE INSTALLATION CONTRACTOR OR | | OTHER INTERESTED PARTIES REGARDING THE LAYOUT OF THE | | SYSTEM(S), SHALL BE INCLUDED IN THE FIRE PROTECTION | | SYSTEM ENGINEERING DOCUMENTS. | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.003, AMENDED | | 4-2-2000, 6-26-01 | | | | 61G15-32.004 DESIGN OF WATER BASED FIRE PROTECTION | | SYSTEMS. | | (1) WATER BASED FIRE PROTECTION SYSTEMS INCLUDE, BUT | | ARE NOT LIMITED TO, AUTOMATIC SPRINKLER SYSTEMS OF WET, | | DRY, FINE WATER SPRAY (MIST), MANUAL, AND DELUGE VALVE | | CONTROLLED TYPES, PUMPING SYSTEMS, STANDPIPES, FIRE | | WATER MAINS AND DEDICATED FIRE PROTECTION WATER | | SOURCES. | | (2) TO ENSURE MINIMUM DESIGN QUALITY IN FIRE PROTECTION | | SYSTEM ENGINEERING DOCUMENTS, SAID DOCUMENTS SHALL | | INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION WHEN | | APPLICABLE: | | (A) THE POINT OF SERVICE FOR THE FIRE PROTECTION WATER | | SUPPLY AS DEFINED BY 633.021(18) F.S. | | (B) APPLICABLE NFPA STANDARD TO BE APPLIED, OR IN THE | | CASE WHERE NO SUCH STANDARD EXISTS, THE ENGINEERING | | STUDY, JUDGMENTS, AND/OR PERFORMANCE BASED ANALYSIS AND | | CONCLUSIONS. | | (C) CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | AREA. | | (D) DESIGN APPROACH, WHICH INCLUDES SYSTEM TYPE, | | DENSITIES, DEVICE TEMPERATURE RATING, AND SPACING FOR | | EACH SEPARATE 42 HAZARD OCCUPANCY. | | (E) CHARACTERISTICS OF WATER SUPPLY TO BE USED, SUCH AS | | MAIN SIZE AND LOCATION, WHETHER IT IS DEAD-END OR | | CIRCULATING; AND IF DEAD-END, THE DISTANCE TO THE | | NEAREST CIRCULATING MAIN, AS WELL AS ITS MINIMUM | | DURATION AND RELIABILITY FOR THE MOST HYDRAULICALLY | | DEMANDING DESIGN AREA. | | (F) WHEN PRIVATE OR PUBLIC WATER SUPPLIES ARE USED, THE | | FLOW TEST DATA, INCLUDING DATE AND TIME OF TEST, WHO | | CONDUCTED TEST OR SUPPLIED INFORMATION, TEST ELEVATION, | | STATIC GAUGE PRESSURE AT NO FLOW, FLOW RATE WITH | | RESIDUAL GAUGE PRESSURE, HYDRANT BUTT COEFFICIENT, AND | | LOCATION OF TEST IN RELATION TO THE HYDRAULIC POINT OF | | SERVICE. | | (G) VALVING AND ALARM REQUIREMENTS TO MINIMIZE | | POTENTIAL FOR IMPAIRMENTS AND UNRECOGNIZED FLOW OF | | WATER. | | (H) MICROBIAL INDUCED CORROSION (MIC). THE ENGINEER OF | | RECORD SHALL MAKE REASONABLE EFFORTS TO IDENTIFY WATER | | SUPPLIES THAT COULD LEAD TO MICROBIAL INDUCED CORROSION | | (MIC). SUCH EFFORTS MAY CONSIST OF DISCUSSIONS WITH THE | | LOCAL WATER PURVEYOR AND/OR FIRE OFFICIAL, FAMILIARITY | | WITH CONDITIONS IN THE LOCAL AREA, OR LABORATORY | | TESTING OF WATER SUPPLIES. WHEN CONDITIONS ARE FOUND | | THAT MAY RESULT IN MIC CONTAMINATION OF THE FIRE | | PROTECTION PIPING, THE ENGINEER SHALL DESIGN CORRECTIVE | | MEASURES. | | (I) BACKFLOW PREVENTION AND METERING SPECIFICATIONS AND | | DETAILS TO MEET LOCAL WATER PURVEYOR REQUIREMENTS | | INCLUDING MAXIMUM ALLOWABLE PRESSURE DROP. | | (J) QUALITY AND PERFORMANCE SPECIFICATIONS OF ALL YARD | | AND INTERIOR FIRE PROTECTION COMPONENTS. | | (3) CONTRACTOR SUBMITTALS WHICH DEVIATE FROM THE ABOVE | | MINIMUM DESIGN PARAMETERS SHALL BE CONSIDERED MATERIAL | | DEVIATIONS AND REQUIRE SUPPLEMENTAL ENGINEERING | | APPROVAL AND DOCUMENTATION. | | (4) IN THE EVENT THE ENGINEER OF RECORD PROVIDES MORE | | INFORMATION AND DIRECTION THAN IS ESTABLISHED ABOVE, HE | | OR SHE SHALL BE HELD RESPONSIBLE FOR THE TECHNICAL | | ACCURACY OF THE WORK IN ACCORDANCE WITH APPLICABLE | | CODES, STANDARDS, AND SOUND ENGINEERING PRINCIPLES. | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.004, AMENDED | | 4-2-2000, 6-26-01, 7-12-05 | | FAC 61G15-32.002 DEFINES THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENT (5) AS WELL AS THE FIRE PROTECTION | | SYSTEM LAYOUT DOCUMENT (6). 61G15-32.003 OUTLINES THE | | COMMON REQUIREMENTS TO ALL FIRE PROTECTIONS ENGINEERING | | DOCUMENTS WITH 32.004 (2) (A-J) OUTLINING THE MINIMUM | | INFORMATION TO BE PROVIDED ON FIRE PROTECTION | | ENGINEERING DOCUMENTS FOR WATER BASED SYSTEMS. AS | | STATED IN THE DEFINITIONS, THE CONTRACTOR IS TO DEVELOP | | THE LAYOUT DOCUMENTS BASED ON THE DESIGN CRITERIA | | PROVIDED IN THE FIRE PROTECTION ENGINEERING DOCUMENTS | | BY THE ENGINEER OF RECORD FOR THE FIRE SPRINKLER | | SYSTEM. THE FIRE PROTECTION SYSTEM ENGINEERING | | DOCUMENTS ARE SUBMITTED FOR THE MASTER PERMIT (BUILDING | | PERMIT PER FBC) AND THE LAYOUT DOCUMENTS ARE SUBMITTED | | FOR THE FIRE SPRINKLER INSTALLATION PERMIT. | | | | PLEASE PROVIDE FOR THE REQUIEMENTS EITHER IN DRAWING OR | | NARRATIVE FORM SIGNED AND SEALED WITH THIS MASTER | | PERMIT. | | | | | | | | 2) SHEET FOOD SERVICES EQUIPMENT - THERE ARE | | INDICATIONS OF A HOOD AND SUPPRESSION SYSTEM. | | | | THE HOOD AND SUPPRESSION SYSTEM SHALL BE INSTALLED | | UNDER SEPARATE PERMITS AND SHOP DRAWINGS. THE SHEETS | | WILL BE APPROVED IN CONCEPT ONLY. | | | | ENSURE COMPLIANCE AND PLEASE PROVIDE AN APPLICABLE NOTE | | OF ACKNOWEDGEMENT | | | | | | | | | | | | | | WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET REVISION | | CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE ABOVE. | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-11-29 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-11-29 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2021-11-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-11-01 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-11-01 |
Time |
08:00 |
Sent To |
|
|
Notes |
2021-11-01 11:37:41 | 3RD REVIEW FBC-2020 FUEL GAS | | PERMIT- 21051188 | | 11/1/2021 | | | | CODES IN EFFECT: | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P6.1 REVISED GAS RISER: | | A) THE 2-INCH PIPE FROM THE LOW-PRESSURE REGULATOR TO | | THE FIRST TEE IS UNDERSIZED PER TABLE 402.4(2) FBC FG. | | BASED ON THE NOTES ON THE PLAN A MINIMUM 3-INCH IS | | REQUIRED FOR THE 1,776,000 BTU LOAD AT 132 FT. | | DEVELOPED LENGTH. | | B) THE 1-1/4 INCH HORIZONTAL BRANCH PIPE SUPPLYING THE | | WATER HEATERS IS UNDERSIZED. A MINIMUM 2-INCH PIPE IS | | REQUIRED TO THE 1ST AND 2ND TEES, AND THEN A MINIMUM | | 1-1/2 INCH PIPE TO THE THIRD TEE- TABLE 402.4(2). | | C) PLEASE SHOW THE REQUIRED REGULATORS AT THE COOKING | | APPLIANCES. VERY TYPICALLY THE INPUT PRESSURES FOR THE | | APPLIANCES ARE BELOW 8 IN.W.C.- SECTION 410.2 FBC FG. | | BASED ON THE PLAN NOTE DEFERRED SUBMITTALS ARE ACCEPTED | | FOR THE REGULATORS AND APPLIANCES. | | | | 2) P2.1: AS PREVIOUSLY NOTED THE MANUFACTURER'S | | SPECIFICATIONS AND INSTALLATION MANUALS FOR THE | | TANKLESS WATER HEATERS ARE ACCEPTED AS DEFERRED | | SUBMITTALS HOWEVER PLEASE VERIFY THE WATER HEATERS ARE | | THE NON- CONDENSING TYPE OR PLEASE PROVIDE A CONDENSATE | | DISPOSAL PLAN- SECTION 307.2 FBC FG. | | | | 3) P3.1: PLEASE INDICATE ON WHICH ARCHITECTURAL SHEET | | THE VEHICLE IMPACT PROTECTION IS LOCATED- SECTION | | 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2021-09-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-09-14 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-09-13 |
Time |
13:44 |
Sent To |
|
|
Notes |
2021-09-14 10:24:51 | 2ND REVIEW FBC-2020 FUEL GAS | | PERMIT- 21051188 | | 9/14/2021 | | | | CODES IN EFFECT: | | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | PLAN REVIEW RESULTS: DENIED. | | | | 1) FAILED SHEET P6.1 GAS RISER- FBC FG: THE TOTAL BTU | | LOAD IN THE COMPLETE SYSTEM TABLE OF 1,179,000 BTU DOES | | NOT MATCH THE ISOMETRIC WHICH SHOWS A TOTAL OF 980,000 | | BTU. IT APPEARS THAT THE BRANCH LINE TO THE GWH, AND | | THE GWH BTU LOAD IS NOT INCLUDED IN THE ISOMETRIC | | DRAWING. A) THE ?-INCH PIPE STUB-OUTS ARE UNDERSIZED | | USING TABLE 402.4(2) FOR A SYSTEM AT A TDL OF 44 FT. | | | | E) FAILED. SHOW THE LOCATIONS OF PIPE UNIONS AT MP | | REGULATORS- SECTION 410.2 (7). CORRECT THE NOTE TO | | INDICATE UNIONS INSTALLED WITHIN 1 FT. OF EITHER SIDE | | OF THE REGULATOR, | | | | F) FAILED. PROVIDE REGULATOR INDEPENDENT VENTING | | DETAILS INCLUDING TYPES AND SIZES OF VENT PIPING, | | PIPING RUNS AND TERMINATION LOCATIONS- SECTIONS 410.3 & | | 410.3.1. VENT PIPING DETAILS FOR THE PRIMARY REGULATOR | | NOT PROVIDED, AND NO INFORMATION PROVIDED FOR THE | | COOKING LINE REGULATORS- VENTED OR VENTLESS? | | H) FAILED. PROVIDE THE PIPE SIZING TABLES USED TO | | DESIGN THE SYSTEM- SECTION 402.4. 2-PSI TABLE NOT | | PROVIDED. | | | | 2) FAILED. SHEET P3.1: PROTECTION FROM VEHICLE DAMAGE | | IS REQUIRED FOR THE METER, WATER HEATER AND GAS PIPING- | | SECTION 303.4 FBC FG. NO INFORMATION PROVIDED ON P3.1. | | REVISED SHEET A1.01 INDICATES PROTECTION FOR THE METER | | ONLY. | | | | 6) FAILED. P3.1 & P6.1: PROVIDE COMBUSTION AIR | | CALCULATIONS FOR THE GAS-FIRED APPLIANCES AND INDICATE | | HOW THE AIR WILL BE SUPPLIED- SECTION 304.1 FBC P. THE | | SUBMITTED CALCS ARE USING THE EQUATION FOUND IN SECTION | | 304.5.2 WHICH CAN ONLY BE USED WHEN THERE IS A KNOWN | | AIR INFILTRATION RATE LESS THAN .40 AIR CHANGES PER | | HOUR (ACH). THE CALCULATIONS PROVIDED ARE USING AN ACH | | OF 5.6. THE CALCULATION IS ALSO USING 1835 CFMS OF O/A | | AS THE BASIS OF THE ACH, HOWEVER THE AIR IS BEING | | SUPPLIED MECHANICALLY AS OPPOSED TO INFILTRATION. IF | | USING MECHANICAL AIR PLEASE REFER TO SECTION 304.9 AND | | PROVIDE THE CALCULATION. IF USING INDOOR AIR THEN THE | | REQUIRED VOLUME IS BASED ON 50 CU.FT. PER 1000 BTU OR | | IN THIS CASE- 49,000 CU. FT. PLEASE REVIEW SECTION | | 304.5.1 BELOW: | | THE REQUIRED VOLUME OF INDOOR AIR SHALL BE DETERMINED | | IN ACCORDANCE WITH SECTION 304.5.1 OR 304.5.2, EXCEPT | | THAT WHERE THE AIR INFILTRATION RATE IS KNOWN TO BE | | LESS THAN 0.40 AIR CHANGES PER HOUR (ACH), SECTION | | 304.5.2 SHALL BE USED. THE TOTAL REQUIRED VOLUME SHALL | | BE THE SUM OF THE REQUIRED VOLUME CALCULATED FOR ALL | | APPLIANCES LOCATED WITHIN THE SPACE. ROOMS | | COMMUNICATING DIRECTLY WITH THE SPACE IN WHICH THE | | APPLIANCES ARE INSTALLED THROUGH OPENINGS NOT FURNISHED | | WITH DOORS, AND THROUGH COMBUSTION AIR OPENINGS SIZED | | AND LOCATED IN ACCORDANCE WITH SECTION 304.5.3, ARE | | CONSIDERED TO BE PART OF THE REQUIRED VOLUME. | | | | 7) FAILED. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | GAS-FIRED APPLIANCES- SECTIONS 301.3 & 623.1 FBC FG. | | DEFERRED SUBMITTAL REQUEST IS ACCEPTED HOWEVER PLEASE | | PROVIDE A LIST ON THE PLANS- SECTION 107.4.3.1 WPB. | | | | 9) FAILED. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | REGULATORS AND REGULATOR VENT SYSTEMS- SECTIONS 410.1, | | 410.2, & 410.3 FBC FG. DEFERRED SUBMITTAL REQUEST IS | | ACCEPTED HOWEVER PLEASE PROVIDE A LIST ON THE PLANS- | | SECTION 107.4.3.1 WPB. | | | | 10) FAILED. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR | | THE TANKLESS WATER HEATER AND INDICATE THE MANUFACTURER | | OF THE APPLIANCE IN THE EQUIPMENT SCHEDULE- SECTION | | 624.1 FBC FG. IF THE APPLIANCE PRODUCES CONDENSATION | | PLEASE SHOW HOW THE DRAINAGE WILL BE CONVEYED AWAY FROM | | THE BUILDING TO AN APPROVED PLACE OF DISPOSAL OTHER | | THEN ONTO THE SURFACE OF THE SIDEWALK- SECTIONS 307.2 & | | 307.3 FBC FG. CONDENSATE DISPOSAL PLAN NOT PROVIDED. | | DEFERRED SUBMITTAL REQUEST IS ACCEPTED HOWEVER PLEASE | | PROVIDE A LIST ON THE PLANS- SECTION 107.4.3.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-07-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-07-02 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-06-30 |
Time |
12:42 |
Sent To |
|
|
Notes |
2021-07-02 11:05:51 | 1ST REVIEW FBC-2020 FUEL GAS | | PERMIT- 21051188 | | 7/2/2021 | | | | CODES IN EFFECT: | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P6.1 GAS RISER- FBC FG: | | A) SHOW THE LOCATION OF THE METER AND GAS DELIVERY | | PRESSURE AT THE METER- SECTION 402.1. | | B) PROVIDE THE LENGTH OF THE MAIN SUPPLY PIPE FROM THE | | METER TO THE TEE, AND FROM THE TEE TO THE REGULATORS- | | SECTIONS 402.3 & 402.4.1. | | C) PROVIDE THE TOTAL LENGTHS OF EACH BRANCH PIPING RUN | | FROM THE REGULATORS TO THE MOST REMOTE OUTLETS- | | SECTIONS 402.4.1 & 402.4.2 FBC FG. | | D) SHOW THE LOCATIONS OF APPLIANCE REGULATORS- SECTION | | 410.1. | | E) SHOW THE LOCATIONS OF PIPE UNIONS AT MP REGULATORS- | | SECTION 410.2 (7). | | F) PROVIDE REGULATOR INDEPENDENT VENTING DETAILS | | INCLUDING TYPES AND SIZES OF VENT PIPING, PIPING RUNS | | AND TERMINATION LOCATIONS- SECTIONS 410.3 & 410.3.1. | | G) IF EXCESS FLOW OR PRESSURE REDUCING VALVES ARE TO BE | | INSTALLED, PLEASE SHOW THE LOCATIONS AND PROVIDE | | SPECIFICATIONS- SECTION 410.4. | | H) PROVIDE THE PIPE SIZING TABLES USED TO DESIGN THE | | SYSTEM- SECTION 402.4. | | | | 2) SHEET P3.1: PROTECTION FROM VEHICLE DAMAGE IS | | REQUIRED FOR THE METER, WATER HEATER AND GAS PIPING- | | SECTION 303.4 FBC FG. | | | | 3) P3.1: THE PLAN INDICATES AN EXISTING METER HOWEVER | | THE DEMOLITION PLAN A.100 (CONTAINED IN THIS SUBMITTAL | | AND SUBMITTED UNDER DEMOLITION APPLICATION 21041388) | | AND C-2 SHOW COMPLETE REMOVAL OF THE BUILDING AND | | METER. PLEASE LABEL THE METER AS NEW OR AS | | REINSTALLATION OF REMOVED METER- SECTION 107.2.1 WPB. | | | | 4) C8 & P3.1: REVISE C8 TO SHOW THE CORRECT LOCATION OF | | THE NEW GAS SERVICE LINE TO THE METER- SECTION 107.2.1. | | | | 5) P3.1: A) SHOW TYPES AND SIZES OF GAS PIPING- SECTION | | 402.3 FBC FG | | B) P3.1 & P4.1: LABEL ALL GAS-FIRED APPLIANCES USING | | THE DESIGNATED NUMBERS IN THE EQUIPMENT SCHEDULES- | | SECTION 107.2.1 WPB. | | C) SHOW THE ACCESSIBLE LOCATIONS OF THE MANUAL AND | | AUTOMATIC GAS VALVES- SECTION 409.1.3 FBC FG. | | | | 6) P3.1 & P6.1: PROVIDE COMBUSTION AIR CALCULATIONS FOR | | THE GAS-FIRED APPLIANCES AND INDICATE HOW THE AIR WILL | | BE SUPPLIED- SECTION 304.1 FBC P. | | | | 7) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | GAS-FIRED APPLIANCES- SECTIONS 301.3 & 623.1 FBC FG. | | | | 9) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | REGULATORS AND REGULATOR VENT SYSTEMS- SECTIONS 410.1, | | 410.2, & 410.3 FBC FG. | | | | 10) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | TANKLESS WATER HEATER AND INDICATE THE MANUFACTURER OF | | THE APPLIANCE IN THE EQUIPMENT SCHEDULE- SECTION 624.1 | | FBC FG. IF THE APPLIANCE PRODUCES CONDENSATION PLEASE | | SHOW HOW THE DRAINAGE WILL BE CONVEYED AWAY FROM THE | | BUILDING TO AN APPROVED PLACE OF DISPOSAL OTHER THEN | | ONTO THE SURFACE OF THE SIDEWALK- SECTIONS 307.2 & | | 307.3 FBC FG. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2021-12-02 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-12-02 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-11-10 |
Time |
13:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-11-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-11-12 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-11-12 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-11-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-11-05 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-10-06 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-09-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-09-23 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-08-13 |
Time |
07:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-07-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-07-15 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-05-28 |
Time |
11:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-12-10 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-12-10 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-12-02 |
Time |
09:31 |
Sent To |
|
|
Notes |
2021-12-10 09:55:27 | RECEIPT MU-2021-056963 - $54,698.12 PAID | | | 2021-12-02 09:31:39 | 12/2/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-07-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-07-15 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-07-15 |
Time |
12:19 |
Sent To |
|
|
Notes |
2021-07-15 12:20:56 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2021-10-25 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-10-25 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-10-25 |
Time |
16:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-08-30 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-08-30 |
Time |
06:24 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-08-30 |
Time |
06:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-06-23 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-23 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-06-23 |
Time |
14:17 |
Sent To |
|
|
Notes |
2021-06-23 14:17:52 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-21051188 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET A0.03 INDICATES A 1-HOUR RATED WALL | | SURROUNDING THE COMMUNITY/ BOARD ROOM. PLEASE SHOW THE | | REQUIRED PROTECTION IN THESE WALLS AT ALL DUCT | | PENETRATIONS ON SHEET M2.2. FBC M607 | | | | 2) PLEASE ATTACH A NOTE ON THE DRAWING INDICATING THAT | | THE KITCHEN HOODS WILL REQUIRE SEPARATE SUBMITTAL FOR | | PERMITS AND REVIEWS AND WILL NOT BE REVIEWED ON THIS | | PERMIT. | | | | 3) PLEASE ATTACH A NOTE ON THE DRAWING INDICATING THAT | | THE REFRIGERATION EQUIPMENT WILL REQUIRE SEPARATE | | SUBMITTAL FOR PERMITS AND REVIEWS AND WILL NOT BE | | REVIEWED ON THIS PERMIT. | | | | 4) PLEASE INCLUDE THE KITCHEN WITH THE OUTDOOR AIR | | CALCULATIONS. THE 2020 FBC M NOW IS REQUIRING OUTDOOR | | AIR FOR THE COOKING KITCHEN ALONG WITH THE EXHAUST AIR. | | FBC M TABLE 403.3.1.1 | | | | 5) SHEET M2-1: PLEASE SHOW THE RTU FOR THE 2 12X12 | | DUCTS SUPPLYING AIR TO THE OFFICE AND CAF? JOSHUA, IT | | APPEARS TO BE A BIG HORSESHOE AND DOESN?T SHOW THE RTU. | | FBC 107.2.1 | | | | 6) PLEASE IDENTIFY THE BATHROOM EXHAUST FANS ON THE | | DRAWINGS. FBC 107.2.1 | | | | 7) PLEASE PROVIDE OUTDOOR AIR CALCULATIONS FOR EACH USE | | OF SPACE IN THIS 2 STORY BUILDING INCLUDING STORAGE AND | | CORRIDORS, SMALL CAF? ON SECOND FLOOR. FBC M 403.3.1.1 | | | | 8) PLEASE PROVIDE THE CORRECT OCCUPANCY FROM TABLE | | 403.3.1.1 FOR THE AREA LABELED EDUCATION/FLEX ON SHEET | | M2.2 FBC M TABLE 403.3.1.1. | | | | 9) PLEASE SHOW HOW THE KITCHEN RETURN AIR MEETS THE | | REQUIREMENTS OF SECTION 601.5 (7) FOR RETURN AIR | | OPENINGS. | | | | 10) SHEET M6.1: PLEASE INCLUDE AIR BALANCE REPORT THAT | | INCLUDES ALL BATH EXHAUST AND MEETS THE REQUIREMENTS OF | | FBC M 508.1.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-11-29 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-11-29 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2021-11-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-11-01 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-11-01 |
Time |
08:00 |
Sent To |
|
|
Notes |
2021-11-01 11:39:14 | 3RD REVIEW FBC-2020 PLUMBING | | PERMIIT- 21051188 | | 11/1/21 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS A4.03 & A4.04: PLEASE CORRECT THE HEIGHTS OF | | THE MIRRORS TO INDICATE 40-INCHES FROM THE FINISHED | | FLOORS TO THE BOTTOM EDGES OF THE REFLECTIVE SURFACES- | | SECTION 603.3 FBC ACC. | | | | 2) P2.3: PLEASE SHOW THE CONDENSATE PIPING RUNS TO THE | | ROOF DRAINS AND PROVIDE SUPPORT DETAILS- SECTION | | 314.2.1 & TABLE 308.5 FBC P. | | | | 3) P2.1 & P5.1: PLEASE CORRECT THE ISOMETRIC DRAWINGS | | SHOWING THE 3-INCH DRAIN PIPE FROM THE FLOOR SINK AT | | THE COFFEE STATION CONNECTING TO THE SANITARY SYSTEM- | | SECTION 1003.3.1 FBC P. | | | | 4) 2ND REQUEST FOR A LIST OF SEPARATE PERMITS AND | | DEFERRED SUBMITTALS TO BE PLACED ON THE PLANS- SECTION | | 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2021-09-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-09-14 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-09-13 |
Time |
13:44 |
Sent To |
|
|
Notes |
2021-09-14 09:15:11 | 2ND REVIEW FBC-2020 PLUMBING | | PERMIIT- 21051188 | | 9/14/21 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES IN | | CAPS. TO HELP EXPEDITE FINAL APPROVAL OF THE PLUMBING | | PLANS, PLEASE PROVIDE LISTS OF SEPARATE PERMITS AND | | DEFERRED PLUMBING PRODUCT SUBMITTALS ON THE PLANS- | | SECTIONS 107.2.1 & 107.3.4.1 WPB. | | | | 2) FAILED. SHEETS A0.24 & A0.25: THE FINISH WALL | | SCHEDULE FOR THE MEN'S, WOMEN'S AND FAMILY TOILET | | ROOMS, AND THE UTILITY ROOMS INDICATES NON-COMPLIANT | | PAINTED DRYWALL FOR FINISHED WALL SURROUND MATERIALS AT | | PLUMBING FIXTURE LOCATIONS INCLUDING THE MOP SINKS- SEE | | SECTION 310.3 FBC P AND SECTION 1210.2.2 FBC B AND | | PROVIDE A HARD, NON-ABSORBENT MATERIAL SUCH AS TILE. | | THE FINISH SCHEDULE INDICATES PAINTED DRYWALL AT THE | | MOP SINK IN UTILITY RM 1025. | | | | 17) FAILED A, B, & C. P2.3 ROOF AND STORM DRAIN PLAN: | | | | A) FAILED. PROVIDE DRAINAGE CALCULATIONS IN ACCORDANCE | | WITH SECTION 1106.1 FBC P. SHEET P2.3: THE CALCULATION | | TABLE INDICATES TOTAL 12616 SQ. FT. BUT THE SQUARE FOOT | | AREAS SHOWN ON THE PLAN ADD UP TO 10352 SQ. FT. | | | | B) FAILED. PROVIDE STORM DRAINAGE ISOMETRIC DRAWINGS | | FOR PRIMARY AND SECONDARY ROOF DRAIN SYSTEMS. INDICATE | | THE SIZES OF THE HORIZONTAL AND VERTICAL STORM DRAIN | | PIPES, THE GPM FLOW AT EACH ROOF DRAIN LOCATION, AND | | THE PIPE RUNS AND DISCHARGE LOCATIONS- TABLES 1106.2 & | | 1106.3 FBC P. INDICATE HOW THE RAINWATER FROM THE ROOF | | WILL BE DRAINED AWAY FROM THE BUILDING TO AN APPROVED | | PLACE OF DISPOSAL- SECTION 1101.2 FBC P. SHEET P5.1: | | THE KEYNOTES #3 & #4 NEED TO EXCHANGE LOCATIONS ON THE | | DRAWING. | | | | C) FAILED. VERIFY THE ROOF IS DESIGNED IN COMPLIANCE | | WITH SECTION 1101.7 ROOF DESIGN. | | ROOFS SHALL BE DESIGNED FOR THE MAXIMUM POSSIBLE DEPTH | | OF WATER THAT WILL POND THEREON AS DETERMINED BY THE | | RELATIVE LEVELS OF ROOF DECK AND OVERFLOW WEIRS, | | SCUPPERS, EDGES OR SERVICEABLE DRAINS IN COMBINATION | | WITH THE DEFLECTED STRUCTURAL ELEMENTS. IN DETERMINING | | THE MAXIMUM POSSIBLE DEPTH OF WATER, ALL PRIMARY ROOF | | DRAINAGE MEANS SHALL BE ASSUMED TO BE BLOCKED. THE | | MAXIMUM POSSIBLE DEPTH OF WATER ON THE ROOF SHALL | | INCLUDE THE HEIGHT OF THE WATER REQUIRED ABOVE THE | | INLET OF THE SECONDARY ROOF DRAINAGE MEANS TO ACHIEVE | | THE REQUIRED FLOW RATE OF THE SECONDARY DRAINAGE MEANS | | TO ACCOMMODATE THE DESIGN RAINFALL RATE AS REQUIRED BY | | SECTION 1106. NOT PROVIDED. | | | | 18) FAILED. P2.1, P4.1, P5.1 & K1.0: HAND SINKS 001, | | 504, 505, 506, 507, & 508 SHALL NOT DRAIN INTO THE | | GREASE WASTE LINE AND INTERCEPTOR- SECTION 1003.3.1 FBC | | P. SHEET P5.1: HANDSINK 507 SHALL NOT DRAIN INTO THE | | GREASE WASTE LINE. | | | | 19) FAILED. P2.1, P4.1, P5.1 & K1.0: DRAINAGE FROM THE | | FLOOR SINKS AT THE CONDENSATE HOOD AND BY THE ICE | | MAKER/ICE BIN, AND FROM THE EVAPORATORS AND FLOOR | | DRAINS IN THE WALK-IN BOXES SHALL NOT DRAIN INTO THE | | GREASE WASTE LINE AND INTERCEPTOR- SECTION 1003.3.1 FBC | | P. PLEASE NOTE THAT SEC. 90- 126 PROHIBITS CONDENSATE | | FROM COOLING COILS TO DRAIN INTO THE SANITARY SYSTEM. | | PLEASE CLARIFY THE PURPOSE OF THE TRENCH DRAIN AND WHAT | | TYPE OF WASTE-WATER IT IS CONVEYING- SECTION 1003.3.1 | | FBC P. SHEET P5.1: A) THE FLOOR DRAIN AT FREEZER 300.3 | | SHALL NOT DRAIN INTO THE GREASE WASTE LINE. B) PLEASE | | CLARIFY THE PURPOSE OF THE TRENCH DRAIN AND WHAT TYPE | | OF DRAINAGE IT WILL CONVEY- CLEAR WATER WASTE OR GREASE | | WASTE? C) PLEASE CLARIFY THE PURPOSE OF THE FLOOR SINK | | AT THE COFFEE STATION AND WHAT TYPE OF DRAINAGE WILL IT | | CONVEY- CLEAR WATER WASTE OR GREASE WASTE. PLEASE NOTE | | GREASE WASTE INCLUDES FATS AND OILS FROM MILK AND SYRUP | | PRODUCTS. | | | | 25) FAILED. P0.1, P2.1 & P5.1: INDICATE HOW THE | | EXTERIOR MOP SINK WILL BE PROTECTED FROM VEHICLE | | DAMAGE, STORM WATER AND DETRIMENTAL DRAINAGE INTRUSION- | | SECTIONS 302.1 & 305.7 FBC P. MOP SINK COVER AND | | PARKING STOP NOT SHOWN ON THE PLANS. | | | | 26) FAILED. P0.1: PROVIDE AN INDIRECT WASTE DETAIL FOR | | THE KITCHEN SINKS AND FIXTURES- SECTIONS 802.1 & | | 802.1.1 FBC P. P7.1: PLEASE SHOW A DETAIL FOR THE | | 3-COMPARTMENT SINK IN COMPLIANCE WITH SECTION 802.1.1 | | FBC P. | | | | 34) FAILED. P0.1: PROVIDE THE TYPE AND THICKNESS OF THE | | PIPE INSULATION- SECTION 607.5 FBC P AND TABLE | | C403.2.10 FBC EC. INSULATION THICKNESSES NOT PROVIDED. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-07-01 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-06-30 |
Time |
11:10 |
Sent To |
|
|
Notes |
2021-07-01 09:20:55 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIIT- 21051188 | | 6/30/21 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE NOTE THAT INSTALLATION OF THE IRRIGATION | | SYSTEM AND THE GREASE INTERCEPTOR SHALL BE UNDER | | SEPARATE PERMIT AND WILL REQUIRE SEPARATE PRIMARY | | PERMIT APPLICATIONS AND PLAN SUBMITTALS- SECTION 105.1 | | & 107.2.1. THE CIVIL PLAN C8 SHOWS EXISTING BACKFLOW | | PREVENTERS FOR THE POTABLE WATER SERVICE AND FIRE LINE- | | PLEASE NOTE THAT REPLACEMENT OR RELOCATION OF THE | | DEVICES WILL REQUIRE SEPARATE PRIMARY PERMIT | | APPLICATIONS AND PLAN SUBMITTALS. | | | | 2) SHEETS A0.24 & A0.24: THE FINISH WALL SCHEDULE FOR | | THE MEN'S, WOMEN'S AND FAMILY TOILET ROOMS, AND THE | | UTILITY ROOMS INDICATES NON-COMPLIANT PAINTED DRYWALL | | FOR FINISHED WALL SURROUND MATERIALS AT PLUMBING | | FIXTURE LOCATIONS INCLUDING THE MOP SINKS- SEE SECTION | | 310.3 FBC P AND SECTION 1210.2.2 FBC B AND PROVIDE A | | HARD, NON-ABSORBENT MATERIAL SUCH AS TILE. | | | | 3) A1.31, A1.32, A5.3: PROVIDE ROOF AND OVERFLOW DRAIN | | EQUIPMENT SCHEDULES AND PROVIDE INSTALLATION DETAILS- | | SECTION 1105.1 FBC P. | | | | 4) A4.03: SHOW THE CLEAR FLOOR SPACE DIAGRAM AND | | DIMENSION AT THE ACCESSIBLE URINAL- SECTIONS 213.3.3 & | | 605.3 FBC ACC. | | | | 5) A4.03 & A4.04: PROVIDE THE LENGTH DIMENSIONS OF THE | | STANDARD TOILET STALLS- SECTION 405.3.1 FBC P. | | | | 6) A4.03 & A4.03: PROVIDE TURNING SPACE DIAGRAMS IN THE | | TOILET ROOMS AND COMPARTMENTS- SECTION 603.2.1 FBC ACC. | | | | 7) A4.03 & A4.04: PROVIDE THE CLEAR WIDTH OPENINGS OF | | THE TOILET COMPARTMENT DOORS- SECTION 604.8.1.2 AND | | 404.2.3 FBC ACC. | | | | 8) A4.04: PROVIDE A DOOR FOR THE MEN'S TOILET | | COMPARTMENT- FIGURE 604.8.1.6 FBC ACC. | | | | 8) A4.04: PROVIDE THE MANEUVERING CLEARANCE DIAGRAM AND | | DIMENSIONS FOR THE MEN'S AND WOMEN'S TOILET COMPARTMENT | | DOOR- FIGURE 404.2.4.1(A) FBC ACC. | | | | 9) A4.03 & A4.04: SHOW THE MINIMUM 4-INCH CLEARANCES | | FROM THE DOOR OPENINGS TO THE ADJACENT SIDE WALLS- | | SECTION 604.8.1.6 FBC ACC. | | | | 10) A4.03: THE DOOR IN TOILET ROOM 1023 SHALL NOT SWING | | INTO THE CLEAR FLOOR SPACE OF THE LAVATORY- SECTION | | 603.2.3 FBC ACC. | | | | 11) A4.03 & A4.04: PLEASE PROVIDE ENLARGED DRAWINGS FOR | | ALL TOILET ROOMS SHOWN ON THE 1ST AND 2ND FLOORS | | INCLUDING RMS- 1028, 2042, 2044- SECTIONS 213.1 ? | | 213.3.7 FBC ACC. | | | | 12) A4.03 & A4.04: MISSING ACCESSIBILITY COMPLIANCE | | DETAILS AND DIMENSIONS FOR THE TOILET ROOMS. | | A) CENTERLINES OF THE WATER CLOSET FROM THE SIDE WALLS- | | SECTION 604.2. | | B) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | FLOORS- SECTION 604.4. | | C) HEIGHTS OF THE LAVATORY SINK RIM OR COUNTER SURFACE | | FROM THE FINISHED FLOOR- SECTION 606.3. | | D) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO | | THE REFLECTIVE SURFACES- SECTION 603.3 | | E) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4, | | FIGURES 604. | | F) LOCATION OF THE WATER CLOSET FLUSH CONTROLS - | | SECTION 604.6. | | G) CENTERLINES OF THE TOILET PAPER DISPENSER MEASURED | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | FIGURE 604.7. | | H) KNEE AND TOE CLEARANCES FOR THE LAVATORIES AND OTHER | | ACCESSIBLE SINKS- SECTION 606.2. | | | | 13) A0.6, A1.11, A1.13: SHOW THE CLEAR FLOOR DIAGRAMS | | AND DIMENSIONS FOR THE ACCESSIBLE DRINKING FOUNTAINS- | | SECTION 602.2 FBC ACC. REVISE THE DETAIL TO SHOW THE | | SPOUT HEIGHT FOR THE STANDING PERSONS? DRINKING | | FOUNTAIN- SECTION 602.7. INDICATE HOW THE LOCATIONS OF | | THE FOUNTAINS WILL BE IN COMPLIANCE WITH SECTION 307.2 | | PROTRUSION LIMITS. | | | | 14) A1.11, A1.13, & A4.21: SHOW THE LOCATION OF THE | | ACCESSIBLE SINK SHOWN IN ELEVATION 5, AND PROVIDE THE | | CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR FORWARD OR | | PARALLEL APPROACH- SECTION 305.1 & 606.2 FBC ACC. SHOW | | KNEE AND TOE AND TOE CLEARANCE DIAGRAM AND DIMENSIONS | | FOR FORWARD APPROACHES- FIGURE 306.3 FBC ACC. | | | | 15) A1.11, A1.13, & A4.22: SHOW THE LOCATIONS OF THE | | ACCESSIBLE SINK, APPLIANCES AND COFFEE MAKERS SHOWN IN | | ELEVATION 4 AND PROVIDE THE CLEAR FLOOR SPACE DIAGRAMS | | AND DIMENSIONS FOR FORWARD OR PARALLEL APPROACHES, AND | | THE REACH RANGES TO CONTROLS- SECTIONS 606.2, 305.1, | | 308.1 & 309.1 FBC ACC. | | | | 16) P2.1: NOTE #4 IS BEING USED TWICE TO IDENTIFY | | ELEVATOR SUMPS AND WHAT APPEARS TO BE ROOF DRAIN | | VERTICAL LEADERS. PLEASE CHANGE THE NUMBERED NOTE FOR | | THE LEADER AND PROVIDE COMPLETE INFORMATION ABOUT THE | | LEADERS- SECTION 107.2.1 WPB. | | | | 17) P2.3 ROOF AND STORM DRAIN PLAN: | | A) PROVIDE DRAINAGE CALCULATIONS IN ACCORDANCE WITH | | SECTION1106.1 FBC P. | | B) PROVIDE STORM DRAINAGE ISOMETRIC DRAWINGS FOR | | PRIMARY AND SECONDARY ROOF DRAIN SYSTEMS. INDICATE THE | | SIZES OF THE HORIZONTAL AND VERTICAL STORM DRAIN PIPES, | | THE GPM FLOW AT EACH ROOF DRAIN LOCATION, AND THE PIPE | | RUNS AND DISCHARGE LOCATIONS- TABLES 1106.2 & 1106.3 | | FBC P. INDICATE HOW THE RAINWATER FROM THE ROOF WILL BE | | DRAINED AWAY FROM THE BUILDING TO AN APPROVED PLACE OF | | DISPOSAL- SECTION 1101.2 FBC P. | | C) VERIFY THE ROOF IS DESIGNED IN COMPLIANCE WITH | | SECTION 1101.7 ROOF DESIGN. | | ROOFS SHALL BE DESIGNED FOR THE MAXIMUM POSSIBLE DEPTH | | OF WATER THAT WILL POND THEREON AS DETERMINED BY THE | | RELATIVE LEVELS OF ROOF DECK AND OVERFLOW WEIRS, | | SCUPPERS, EDGES OR SERVICEABLE DRAINS IN COMBINATION | | WITH THE DEFLECTED STRUCTURAL ELEMENTS. IN DETERMINING | | THE MAXIMUM POSSIBLE DEPTH OF WATER, ALL PRIMARY ROOF | | DRAINAGE MEANS SHALL BE ASSUMED TO BE BLOCKED. THE | | MAXIMUM POSSIBLE DEPTH OF WATER ON THE ROOF SHALL | | INCLUDE THE HEIGHT OF THE WATER REQUIRED ABOVE THE | | INLET OF THE SECONDARY ROOF DRAINAGE MEANS TO ACHIEVE | | THE REQUIRED FLOW RATE OF THE SECONDARY DRAINAGE MEANS | | TO ACCOMMODATE THE DESIGN RAINFALL RATE AS REQUIRED BY | | SECTION 1106. | | | | 18) P2.1, P4.1, P5.1 & K1.0: HAND SINKS 001, 504, 505, | | 506, 507, & 508 SHALL NOT DRAIN INTO THE GREASE WASTE | | LINE AND INTERCEPTOR- SECTION 1003.3.1 FBC P. | | | | 19) P2.1, P4.1, P5.1 & K1.0: DRAINAGE FROM THE FLOOR | | SINKS AT THE CONDENSATE HOOD AND BY THE ICE MAKER/ICE | | BIN, AND FROM THE EVAPORATORS AND FLOOR DRAINS IN THE | | WALK-IN BOXES SHALL NOT DRAIN INTO THE GREASE WASTE | | LINE AND INTERCEPTOR- SECTION 1003.3.1 FBC P. PLEASE | | NOTE THAT SEC. 90- 126 PROHIBITS CONDENSATE FROM | | COOLING COILS TO DRAIN INTO THE SANITARY SYSTEM. PLEASE | | CLARIFY THE PURPOSE OF THE TRENCH DRAIN AND WHAT TYPE | | OF WASTE WATER IT IS CONVEYING- SECTION 1003.3.1 FBC P. | | | | 20) P2.1 & P5.1 ELEVATOR SUMPS: | | A) NO SUMP DRAIN IS SHOWN AT ELEV-1- SECTION 712.3.5 | | B) THE 1ST FLOOR SANITARY ISOMETRIC DOES NOT SHOW THE | | SUMP DRAIN CONNECTION- 712.3.5. | | C) PROVIDE A SUMP PIT, AND SUMP PUMP DRAIN DETAIL IN | | ACCORDANCE WITH 712.2, 712.3.2, & 712.5. | | D) PROVIDE AN EQUIPMENT SCHEDULE FOR THE SUMP PUMP- | | 712.3.1, 712.4.2, | | E) PROVIDE AN OIL SEPARATOR UNLESS AN APPROVED ALARM | | SYSTEM IS INSTALLED IN THE SUMP PIT- 1003.4. | | | | 21) P2.1 & P5.1: IT APPEARS THAT THE LOCATIONS OF THE | | FLOOR SINK TRAPS BY THE HOT WELLS (002) AND THE STEAM | | KETTLE (121) ARE EXCEEDING THE MAXIMUM 12 FT. DISTANCE | | TO THE MAIN COMBINATION WASTE AND VENT. | | | | 22) P2.2: THE PLAN APPEARS TO SHOW ROOF DRAINAGE PIPES | | PENETRATING INTO THE INTERIOR EXIT STAIRWAY 008 WHICH | | IS PROHIBITED PER SECTION 1023.5 FBC B. | | | | 23) P0.1 & P2.1: PROVIDE A TRAP PRIMER INSTALLATION | | DETAIL- SECTION 1002.4.1 FBC P. | | | | 24) P0.1, P2.1 & P5.1 GREASE INTERCEPTOR- SECTIONS | | 1003.3.5 & 1003.3.7 FBC P. | | A) PROVIDE SIZING CALCULATIONS. | | B) PROVIDE AN EQUIPMENT SCHEDULE. | | C) SHOW THE LOCATION OF THE SAMPLING PORT AND PROVIDE | | AN INSTALLATION DETAIL. | | D) PROVIDE APPROVED TRAFFIC LID SPECIFICATIONS TO | | PROTECT THE INTERCEPTOR, SAMPLING PORT ACCESS, AND | | CLEANOUT ACCESS FROM VEHICLE DAMAGE. | | | | 25) P0.1, P2.1 & P5.1: INDICATE HOW THE EXTERIOR MOP | | SINK WILL BE PROTECTED FROM VEHICLE DAMAGE, STORM WATER | | AND DETRIMENTAL DRAINAGE INTRUSION- SECTIONS 302.1 & | | 305.7 FBC P. | | | | 26) P0.1: PROVIDE AN INDIRECT WASTE DETAIL FOR THE | | KITCHEN SINKS AND FIXTURES- SECTIONS 802.1 & 802.1.1 | | FBC P. | | | | 27) P0.1, P3.1, P3.2, P6.1: LABEL THE WATER HEATERS AS | | EITHER IWH-1 OR IWH-2 ACCORDING TO THE EQUIPMENT | | SCHEDULE- SECTION 107.2.1 WPB. PLEASE NOTE THAT HOT | | WATER AT 110 DEGREES F OR ABOVE IS REQUIRED FOR MOP | | SINKS AND OTHER SINKS USED FOR CULINARY PURPOSES, | | CLEANSING, LAUNDRY OR BUILDING MAINTENANCE PURPOSES- | | SECTION 607.1 FBC P. | | | | 28) P0.1, P3.1, P3.2, P6.1: IT APPEARS HOT WATER IS | | BEING PROVIDED TO THE LAVATORIES. PLEASE NOTE THAT COLD | | OR TEMPERED WATER IS REQUIRED IN ACCORDANCE WITH | | SECTIONS 419.5 & 607.1.2 FBC P. CLARIFY IF MIXING | | VALVES WILL BE INSTALLED OR IF THE WATER HEATERS | | SERVING THE SINK ARE ASSE 1070 COMPLIANT. | | | | 29) P0.1, P3.1, P3.2, P6.1: SHOW THE LOCATIONS OF | | REQUIRED BACKFLOW PREVENTERS FOR SUPPLY LINES TO | | KITCHEN AND BAR EQUIPMENT- ICE MAKERS, COFFEE MAKERS, | | BEVERAGE DISPENSERS, DISH AND GLASS WARE WASHERS ETC. | | PROVIDE THE TYPES OF DEVICES TO BE INSTALLED AND | | PROVIDE A SCHEDULE ON THE PLANS- SECTION 608.3 FBC P. | | | | 30) P3.1 & P3.2: PLEASE LABEL ALL FIXTURES AND | | APPLIANCES TO BE INSTALLED IN THE SECOND FLOOR CAFE, | | AND ADD THE SANITARY DRAINAGE AND WATER SUPPLY DETAILS | | TO THE PLANS- SECTION 107.2.1 WPB. | | | | 31) P0.1: PROVIDE AN ENLARGED WATER TREATMENT DETAIL. | | SHOW THE PHYSICAL LOCATION OF THE SYSTEM, PIPING | | DETAILS AND PIPING RUNS TO FIXTURES, LOCATIONS OF | | VALVES AND BACKFLOW DEVICES- SECTION 608.4 FBC P. | | | | 32) P3.1 & P6.1: PROVIDE A SHUT OFF VALVE FOR THE WATER | | FEED UP TO THE SECOND FLOOR AND ROOF- SECTION 606.1 (4) | | FBC P. | | | | 33) P0.1: PLEASE ADD THE HOSE BIBS TO THE FIXTURE | | SCHEDULE- SECTION 608.16.4.2 FBC P. | | | | 34) P0.1: PROVIDE THE TYPE AND THICKNESS OF THE PIPE | | INSULATION- SECTION 607.5 FBC P AND TABLE C403.2.10 FBC | | EC. | | | | 35) P0.1: LIST THE MANUFACTURER OF THE WATER HEATER IN | | THE SCHEDULE AND SHOW THE LOCATION OF THE RECIRCULATION | | PUMP IN THE PIPING DETAIL. PROVIDE AN EQUIPMENT | | SCHEDULE FOR THE PUMP- SECTION 607.2 FBC P. | | | | 36) P3.1 & P3.3: NON POTABLE WATER SIGNAGE REQUIRED AT | | HOSE BIB LOCATIONS. REFER TO SECTION 608.9 FBC P AND | | PROVIDE DETAILS. | | | | 37) CLARIFY IF A DRAINAGE SYSTEM CONNECTED TO THE STORM | | DRAINAGE SYSTEM WILL BE INSTALLED IN THE GARDEN CENTER | | AND PROVIDE DRAWINGS AND DETAILS IF APPLICABLE TO THE | | SCOPE OF THE PROJECT- SECTION 107.2.1 WPB. | | | | PLEASE NOTE THAT THE REVIEW OF CORRECTED PLANS MAY | | RESULT WITH ADDITIONAL COMMENTS. WHEN RESUBMITTING, IT | | IS HELPFUL TO PROVIDE A RESPONSE LETTER ADDRESSING EACH | | ITEM ALONG WITH THE CITY RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
Rev No |
1 |
Status |
N |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-11-29 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-11-29 |
Time |
11:19 |
Sent To |
|
|
Notes |
2021-11-29 11:20:29 | A SEPARATE PERMIT IS REQUIRED FOR THE GREASE | | INTERCEPTOR. |
|
|
Review Stop |
P-IRRIGATE |
IRRIGATION REVIEW |
Rev No |
1 |
Status |
N |
Date |
2021-07-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-07-02 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-07-02 |
Time |
11:06 |
Sent To |
|
|
Notes |
2021-07-02 11:12:06 | COMPLETE IRRIGATION PLANS AND SPECIFICATIONS SHALL BE | | SUBMITTED UNDER A SEPARATE PERMIT APPLICATION. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
5 |
Status |
P |
Date |
2021-11-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-30 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-30 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
F |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-29 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-29 |
Time |
08:50 |
Sent To |
|
|
Notes |
2021-11-29 08:56:16 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | 1) IN THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK - | | PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE | | ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE USED ON | | THE PROVIDED PRODUCT APPROVAL MAY REQUIRE ADDITIONAL | | SIGNED AND SEALED ATTACHMENT DETAILS FROM AN ARCHITECT | | OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A | | HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT | | APPROVAL - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE | | PRODUCT APPROVAL. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
F |
Date |
2021-10-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-28 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-28 |
Time |
16:16 |
Sent To |
|
|
Notes |
2021-10-28 16:18:54 | ROOFING REVIEW | | | | PLEASE PROVIDE A COMPLETE (FRONT PAGE AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVAL FOR THE ROOFING SYSTEM. | | | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2021-09-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-09-14 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-09-14 |
Time |
15:26 |
Sent To |
|
|
Notes |
2021-09-14 15:26:34 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2021-07-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-07-15 |
Time |
12:21 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-07-15 |
Time |
12:21 |
Sent To |
|
|
Notes |
2021-07-15 12:21:35 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-11-29 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-11-29 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-11-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-11-12 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-11-12 |
Time |
14:25 |
Sent To |
|
|
Notes |
2021-11-12 14:27:01 | GEOTHERMAL REPORT NOW HAS A DIGITAL SIGNATURE. THE | | SURVEY DRAWINGS WERE ORIGINAL SIGNED AND SEALED PAPER | | DRAWINGS. ME |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2021-10-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-10-28 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-10-28 |
Time |
16:21 |
Sent To |
|
|
Notes |
2021-10-28 16:56:48 | SIGNATURE REVIEW | | | | MOST OF THE DRAWINGS, THE SURVEY AND THE SOIL REPORT DO | | NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | DIVISION AT THE CITY HALL. | | | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-09-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-09-14 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-09-14 |
Time |
15:25 |
Sent To |
|
|
Notes |
2021-08-30 06:27:46 | MECHANICAL DRAWINGS SIGNATURE REVIEW APPROVED. ME |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-06-23 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-23 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-06-23 |
Time |
14:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2021-12-01 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2021-12-01 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
awooten |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2021-10-19 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2021-10-19 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2021-10-19 |
Time |
|
Sent To |
|
|
Notes |
2021-10-19 12:12:05 | *********************************ZONING REVIEW REPEAT | | COMMENTS***************************************** | | | | THIS DEVELOPMENT IS A PART OF AN INFORMAL SITE PLAN | | REVIEW. PLEASE SUBMIT THE SITE PLAN APPROVAL LETTER | | ASSOCIATED WITH THIS DEVELOPMENT. | | | | PLEASE MAKE SURE THE PARKING CALCULATIONS, BUILDING | | HEIGHT AND OTHER SITE DATA IS CONSISTENT ON THE SITE | | PLAN AND THE ARCHITECTUAL SITE PLAN. | | | | THE LANDSCAPE PLANS SHOULD BE SUBMITTED UNDER A | | SEPARATE PERMIT. | | | | PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON THE | | PROPERTY, A TREE ALTERATION PERMIT SHALL BE SUBMITTED, | | REVIEWED, AND APPROVED BY THE DEVELOPMENT SERVICES | | DEPARTMENT, PLANNING DIVISION. PLEASE CONTACT RAY | | CARANCI OR ANDREW BURNETT FOR LANDSCAPE INQUIRIES | | 561-822-1562 | | | | ALANA WOOTEN | | PLANNIG DIVISON | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2021-08-27 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2021-08-27 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2021-08-27 |
Time |
|
Sent To |
|
|
Notes |
2021-08-27 14:00:29 | *********************************ZONING | | REVIEW***************************************** | | | | THIS DEVELOPMENT IS A PART OF AN INFORMAL SITE PLAN | | REVIEW. PLEASE SUBMIT THE SITE PLAN APPROVAL LETTER | | ASSOCIATED WITH THIS DEVELOPMENT. | | | | PLEASE MAKE SURE THE PARKING CALCULATIONS, BUILDING | | HEIGHT AND OTHER SITE DATA IS CONSISTENT ON THE SITE | | PLAN AND THE ARCHITECTUAL SITE PLAN. | | | | THE LANDSCAPE PLANS SHOULD BE SUBMITTED UNDER A | | SEPARATE PERMIT. | | | | ALANA WOOTEN | | PLANNIG DIVISON | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2021-06-21 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2021-06-21 |
Time |
|
Rev Time |
|
Received By |
awooten |
Date |
2021-06-21 |
Time |
|
Sent To |
|
|
Notes |
2021-06-21 12:40:38 | *********************************ZONING | | REVIEW***************************************** | | | | THIS DEVELOPMENT IS A PART OF AN INFORMAL SITE PLAN | | REVIEW. PLEASE SUBMIT THE SITE PLAN APPROVAL LETTER | | ASSOCIATED WITH THIS DEVELOPMENT. | | | | ALANA WOOTEN | | PLANNIG DIVISON | | 561-822-1449 | | [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |