Plan Review Stops For Permit 21050968 |
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
P |
Date |
2021-05-20 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-05-20 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-05-20 |
Time |
15:56 |
Sent To |
|
|
Notes |
2021-05-20 15:57:52 | WORK TO BE DONE ON BOTH BUILDINGS, BUILDER PLAN | | REVIEWER MAY REQUIRE SEPARATE PERMITS. HALF ADDRESS HAS | | BEEN READDRESSED. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2021-05-19 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-05-19 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-05-19 |
Time |
14:49 |
Sent To |
|
|
Notes |
2021-05-19 14:50:33 | NOTES FROM CONTRACTOR: | | ANSWER: THE WORK WILL TAKE PLACE IN THE SOUTH BUILDING | | AND THE NORTH BUILDING ALIKE. THE BUILDING PLANS HAVE | | BEEN UPLOADED TO THE PORTAL FOR REVIEW. THE OWNER WILL | | BE IN CONTACT REGARDING THE "READDRESSING". |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2021-05-19 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-05-19 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-05-19 |
Time |
10:41 |
Sent To |
|
|
Notes |
2021-05-19 10:43:12 | TWO PROPERTIES ON PARCEL, WILL THE WORK BE ON THE NORTH | | OR SOUTH BLDG? NORTH BUILDING HAS A HALF ADDRESS WHICH | | WILL NEED TO BE READDRESSED, PLEASE HAVE OWNERS CONTACT | | [email protected] TO DISCUSS ADDRESSING OPTIONS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2021-10-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-10-14 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-10-14 |
Time |
09:28 |
Sent To |
|
|
Notes |
2021-10-14 08:51:44 | BUILDING PROVISOS | | | | 1) THE GARAGE APARTMENT IS LOCATED IN A SPECIAL FLOOD | | HAZARD AREA (AE, BFE 6' NAVD 88). ACCORDING TO THE | | APPRAISAL, THE DEPRECIATED VALUE FOR THE GARAGE | | APARTMENT (GARAGE/GUEST HOUSE) IS $124,872.00. FIFTY | | PERCENT OF THAT IS $62,436.00. THE CUMULATIVE TOTAL OF | | WORK ON THE GARAGE APARTMENT OVER THE LAST FIVE YEARS | | IS $22,357.00. FIFTY PERCENT OF THE APPRAISED VALUE | | ($62,436.00) MINUS THE PREVIOUS WORK FOR THE FIVE | | PREVIOUS YEARS ($22,357.00) IS $40,079.00. IN ORDER FOR | | THIS TO NOT BE CONSIDERED A SUBSTANTIAL IMPROVEMENT, | | THE TOTAL COST OF IMPROVEMENTS TO THE GARAGE APARTMENT | | IS REQUIRED TO BE LESS THAN $40,079.00. THE PROPOSED | | COST OF IMPROVEMENTS TO THE GARAGE APARTMENT IS | | $19,057.50. THEREFORE, THIS PROJECT IS NOT CONSIDERED A | | SUBSTANTIAL IMPROVEMENT. ANY ADDITIONAL IMPROVEMENT | | COSTS THAT MAY BE INCURRED DURING THE REMODELING OF THE | | GARAGE APARTMENT WILL BE COUNTED TOWARDS THE | | SUBSTANTIAL IMPROVEMENT LIMIT. | | | | 2) PROVISO. SUBMIT AN ELEVATION CERTIFICATE FOR THE | | DETACHED GARAGE APARTMENT THAT IS LOCATED IN THE | | SPECIAL FLOOD HAZARD AREA. | | | | 3) PROVISO. [PRODUCT APPROVALS WILL BE DEFERRED. THE | | PRODUCT APPROVALS ARE REQUIRED TO BE SUBMITTED AND | | APPROVED BY THE BUILDING DEPARTMENT BEFORE THEY ARE | | INSTALLED.] (PREVIOUS COMMENT) SUBMIT PRODUCT APPROVALS | | FOR THE TRANSOM WINDOWS AND FRENCH DOORS THAT HAVE BEEN | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. FBC | | AMEND. 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | ROOFING MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL | | MULLIONS AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE | | DEFERRED IF REQUESTED, HOWEVER, THE DOCUMENTS MUST BE | | SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT | | BEFORE THEY CAN BE INSTALLED. ONLY ONE SET IS REQUIRED | | TO BE UPLOADED FOR ELECTRONICALLY SUBMITTED DOCUMENTS. | | | | 4) PROVISO. FENCES AND GATES ARE REQUIRED TO HAVE A | | SEPARATE PERMIT. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2021-10-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-10-04 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-10-04 |
Time |
10:33 |
Sent To |
|
|
Notes |
2021-10-04 11:03:16 | THE SECOND REVIEW WAS ACCIDENTALLY LOCKED. | | | | PLAN REVIEW COMMENTS | | | | 3RD REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO, CFM | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE APPRAISAL THAT WAS SUBMITTED DOES NOT SEPARATE | | THE IMPROVEMENT VALUE OF THE DETACHED GARAGE APARTMENT | | FROM THE MAIN HOUSE. THEY WILL NEED TO BE SEPARATED IN | | ORDER TO DOCUMENT THAT THE IMPROVEMENTS TO THE GARAGE | | APARTMENT ARE A SUBSTANTIAL IMPROVEMENT OR NOT. | | (PREVIOUS COMMENT.) A PORTION OF THE PROPERTY IS | | LOCATED IN A SPECIAL FLOOD HAZARD AREA. THE FLOOD MAPS | | INDICATE THIS AS AN "AE" FLOOD ZONE WITH A 6' BFE. IF | | THIS IS A SUBSTANTIAL IMPROVEMENT THE STRUCTURE WILL BE | | REQUIRED TO BE BROUGHT INTO COMPLIANCE WITH THE CITY OF | | WEST PALM BEACH'S FLOOD ORDINANCE. A SUBSTANTIAL | | IMPROVEMENT IS ANY IMPROVEMENTS OR REPAIRS TO A | | BUILDING OR STRUCTURE FOR WHICH THE CUMULATIVE COST IN | | ANY FIVE YEAR PERIOD EQUALS OR EXCEEDS 50 PERCENT OF | | THE MARKET VALUE OF THE BUILDING OR STRUCTURE AT THE | | END OF THE FIVE YEAR PERIOD AND BEFORE THE IMPROVEMENTS | | OR REPAIRS ARE STARTED. THE PROPERTY HAS THE | | IMPROVEMENT VALUE AS $706,079.00. FIFTY PERCENT OF THIS | | IS $393,039.50. THE CUMULATIVE TOTAL FOR WORK OVER THE | | PAST FIVE YEARS IS $114,296.00 AND THE VALUE SPECIFIED | | FOR THE PROPOSED WORK IS $100,000.00 WHICH TOTALS | | $214,296.00 WHICH IS LESS THAN THE FIFTY PERCENT | | NUMBER. HOWEVER, I SEE THAT YOU DO NOT HAVE A | | CONTRACTOR AT THIS TIME AND I WILL NEED A FIRM NUMBER | | FOR THE COST OF THE PROPOSED WORK BEFORE I CAN APPROVE | | THE PROJECT. | | | | 2) THE COST ESTIMATE FROM THE CONTRACTOR FOR THE GARAGE | | APARTMENT IS MISSING THE WORK FOR THE PROPOSED | | CANTILEVER BALCONY. FBC AMENDMENTS 107.2.1 | | | | 3) THE COST ESTIMATE FROM THE CONTRACTOR FOR THE GARAGE | | APARTMENT IS NOT SIGNED BY THE CONTRACTOR. FBC | | AMENDMENTS 107.2.1 | | | | 4) SUBMIT AN ELEVATION CERTIFICATE FOR THE DETACHED | | GARAGE APARTMENT THAT IS LOCATED IN THE SPECIAL FLOOD | | HAZARD AREA. | | | | 5) PROVISO. [PRODUCT APPROVALS WILL BE DEFERRED. THE | | PRODUCT APPROVALS ARE REQUIRED TO BE SUBMITTED AND | | APPROVED BY THE BUILDING DEPARTMENT BEFORE THEY ARE | | INSTALLED.] (PREVIOUS COMMENT) SUBMIT PRODUCT APPROVALS | | FOR THE TRANSOM WINDOWS AND FRENCH DOORS THAT HAVE BEEN | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. FBC | | AMEND. 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | ROOFING MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL | | MULLIONS AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE | | DEFERRED IF REQUESTED, HOWEVER, THE DOCUMENTS MUST BE | | SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT | | BEFORE THEY CAN BE INSTALLED. ONLY ONE SET IS REQUIRED | | TO BE UPLOADED FOR ELECTRONICALLY SUBMITTED DOCUMENTS. | | | | 6) PROVISO. (NEW COMMENT). FENCES AND GATES ARE | | REQUIRED TO HAVE A SEPARATE PERMIT. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-08-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-08-17 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-08-17 |
Time |
17:10 |
Sent To |
|
|
Notes |
2021-08-17 16:39:27 | THE SECOND REVIEW WAS ACCIDENTALLY LOCKED. | | | | PLAN REVIEW COMMENTS | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO, CFM | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) [THESE BUILDING ARE CONTRIBUTING HISTORIC | | STRUCTURES. THE ARCHITECT'S RESPONSE STATES THAT THIS | | PROJECT IS EXEMPT FROM FLOOD REQUIREMENTS BECAUSE IT IS | | HISTORIC. IF YOU WISH TO PURSUE THIS OPTION YOU WILL BE | | REQUIRED TO APPLY FOR A VARIANCE. CITY ORDINANCE NO. | | 4729-17 SEC.18-286 REQUIRES A VARIANCE FROM THE | | CONSTRUCTION BOARD OF ADJUSTMENTS AND APPEALS IN ORDER | | TO DETERMINE THAT THE REPAIR, IMPROVEMENT OR | | REHABILITATION OF A HISTORIC BUILDING IS ELIGIBLE FOR | | THE EXCEPTION TO THE FLOOD RESISTANT CONSTRUCTION | | REQUIREMENTS OF THE FLORIDA BUILDING CODE, EXISTING | | BUILDING, CHAPTER 12. | | 1201.3 FLOOD HAZARD AREAS. | | IN FLOOD HAZARD AREAS, IF ALL PROPOSED WORK, INCLUDING | | REPAIRS, WORK REQUIRED BECAUSE OF A CHANGE OF | | OCCUPANCY, AND ALTERATIONS, CONSTITUTES SUBSTANTIAL | | IMPROVEMENT, THEN THE BUILDING SHALL COMPLY WITH | | SECTION 1612 OF THE FLORIDA BUILDING CODE, BUILDING, OR | | SECTION R322 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, | | AS APPLICABLE. | | EXCEPTION: IF THE PROGRAM THAT DESIGNATED THE BUILDING | | AS HISTORIC DETERMINES THAT IT WILL CONTINUE TO BE AN | | HISTORIC BUILDING AFTER THE PROPOSED WORK IS COMPLETED, | | THEN THE PROPOSED WORK IS NOT CONSIDERED TO BE | | SUBSTANTIAL IMPROVEMENT. FOR THE PURPOSES OF THIS | | EXCEPTION, AN HISTORIC BUILDING IS: | | 1.INDIVIDUALLY LISTED IN THE NATIONAL REGISTER OF | | HISTORIC PLACES; OR | | 2.A CONTRIBUTING RESOURCE WITHIN A NATIONAL REGISTER OF | | HISTORIC PLACES LISTED DISTRICT; OR | | 3.DESIGNATED AS HISTORIC PROPERTY UNDER AN OFFICIAL | | MUNICIPAL, COUNTY, SPECIAL DISTRICT OR STATE | | DESIGNATION, LAW, ORDINANCE OR RESOLUTION EITHER | | INDIVIDUALLY OR AS A CONTRIBUTING PROPERTY IN A | | DISTRICT, PROVIDED THE LOCAL PROGRAM MAKING THE | | DESIGNATION IS APPROVED BY THE DEPARTMENT OF THE | | INTERIOR (THE FLORIDA STATE HISTORIC PRESERVATION | | OFFICER MAINTAINS A LIST OF APPROVED LOCAL PROGRAMS); | | OR | | 4.DETERMINED ELIGIBLE BY THE FLORIDA STATE HISTORIC | | PRESERVATION OFFICER FOR LISTING IN THE NATIONAL | | REGISTER OF HISTORIC PLACES, EITHER INDIVIDUALLY OR AS | | A CONTRIBUTING PROPERTY IN A DISTRICT.] | | | | (PREVIOUS COMMENT.) A PORTION OF THE PROPERTY IS | | LOCATED IN A SPECIAL FLOOD HAZARD AREA. THE FLOOD MAPS | | INDICATE THIS AS AN "AE" FLOOD ZONE WITH A 6' BFE. IF | | THIS IS A SUBSTANTIAL IMPROVEMENT THE STRUCTURE WILL BE | | REQUIRED TO BE BROUGHT INTO COMPLIANCE WITH THE CITY OF | | WEST PALM BEACH'S FLOOD ORDINANCE. A SUBSTANTIAL | | IMPROVEMENT IS ANY IMPROVEMENTS OR REPAIRS TO A | | BUILDING OR STRUCTURE FOR WHICH THE CUMULATIVE COST IN | | ANY FIVE YEAR PERIOD EQUALS OR EXCEEDS 50 PERCENT OF | | THE MARKET VALUE OF THE BUILDING OR STRUCTURE AT THE | | END OF THE FIVE YEAR PERIOD AND BEFORE THE IMPROVEMENTS | | OR REPAIRS ARE STARTED. THE PROPERTY HAS THE | | IMPROVEMENT VALUE AS $706,079.00. FIFTY PERCENT OF THIS | | IS $393,039.50. THE CUMULATIVE TOTAL FOR WORK OVER THE | | PAST FIVE YEARS IS $114,296.00 AND THE VALUE SPECIFIED | | FOR THE PROPOSED WORK IS $100,000.00 WHICH TOTALS | | $214,296.00 WHICH IS LESS THAN THE FIFTY PERCENT | | NUMBER. HOWEVER, I SEE THAT YOU DO NOT HAVE A | | CONTRACTOR AT THIS TIME AND I WILL NEED A FIRM NUMBER | | FOR THE COST OF THE PROPOSED WORK BEFORE I CAN APPROVE | | THE PROJECT. | | | | 2) [PRODUCT APPROVALS WILL BE DEFERRED. THE PRODUCT | | APPROVALS ARE REQUIRED TO BE SUBMITTED AND APPROVED BY | | THE BUILDING DEPARTMENT BEFORE THEY ARE INSTALLED.] | | (PREVIOUS COMMENT) SUBMIT PRODUCT APPROVALS FOR THE | | TRANSOM WINDOWS AND FRENCH DOORS THAT HAVE BEEN | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. FBC | | AMEND. 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | ROOFING MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL | | MULLIONS AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE | | DEFERRED IF REQUESTED, HOWEVER, THE DOCUMENTS MUST BE | | SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT | | BEFORE THEY CAN BE INSTALLED. ONLY ONE SET IS REQUIRED | | TO BE UPLOADED FOR ELECTRONICALLY SUBMITTED DOCUMENTS. | | | | 3) (PREVIOUS COMMENT) THE PLANS INDICATE THAT THE | | EXISTING GARAGE DOOR IS BEING REPLACED WITH FRENCH | | DOORS. IT APPEARS THAT THE EXISTING GARAGE IS BEING | | CONVERTED INTO AN AIR-CONDITIONED WORK SHOP. THIS WILL | | NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR IMPACT | | FEES. | | | | 4) (NEW COMMENT). FENCES AND GATES ARE REQUIRED TO HAVE | | A SEPARATE PERMIT. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-08-16 |
Time |
16:52 |
Sent To |
|
|
Notes |
2021-08-16 17:05:01 | 1) THESE BUILDING ARE CONTRIBUTING HISTORIC STRUCTURES. | | FENCES AND GATES ARE REQUIRED TO HAVE A SEPARATE | | PERMIT. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-07-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-02 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-02 |
Time |
14:28 |
Sent To |
|
|
Notes |
2021-07-02 15:34:15 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO, CFM | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) A PORTION OF THE PROPERTY IS LOCATED IN A SPECIAL | | FLOOD HAZARD AREA. THE FLOOD MAPS INDICATE THIS AS AN | | "AE" FLOOD ZONE WITH A 6' BFE. IF THIS IS A SUBSTANTIAL | | IMPROVEMENT THE STRUCTURE WILL BE REQUIRED TO BE | | BROUGHT INTO COMPLIANCE WITH THE CITY OF WEST PALM | | BEACH'S FLOOD ORDINANCE. A SUSTANTIAL IMPROVEMENT IS | | ANY IMPROVEMENTS OR REPAIRS TO A BUILDING OR STRUCTURE | | FOR WHICH THE CUMULATIVE COST IN ANY FIVE YEAR PERIOD | | EQUALS OR EXCEEDS 50 PERCENT OF THE MARKET VALUE OF THE | | BUILDING OR STRUCTURE AT THE END OF THE FIVE YEAR | | PERIOD AND BEFORE THE IMPROVEMENTS OR REPAIRS ARE | | STARTED. THE PROPERTY HAS THE IMPROVEMENT VALUE AS | | $706,079.00. FIFTY PERCENT OF THIS IS $393,039.50. THE | | CUMULATIVE TOTAL FOR WORK OVER THE PAST FIVE YEARS IS | | $114,296.00 AND THE VALUE SPECIFIED FOR THE PROPOSED | | WORK IS $100,000.00 WHICH TOTALS $214,296.00 WHICH IS | | LESS THAN THE FIFTY PERCENT NUMBER. HOWEVER, I SEE THAT | | YOU DO NOT HAVE A CONTRACTOR AT THIS TIME AND I WILL | | NEED A FIRM NUMBER FOR THE COST OF THE PROPOSED WORK | | BEFORE I CAN APPROVE THE PROJECT. | | | | 2) SUBMIT PRODUCT APPROVALS FOR THE TRANSOM WINDOWS AND | | FRENCH DOORS THAT HAVE BEEN APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. FBC AMEND. 107.3.4 - PROVIDE TWO | | SETS OF PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE | | REGULATED BY FAC 61G20-3.001 PER FLORIDA STATUTE | | 553.842 (5) THAT HAVE BEEN REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD. PROVIDE TWO COMPLETE | | PRODUCT APPROVALS WITH FL OR NOA NUMBERS INCLUDING | | INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES | | FOR EACH OF THE DIFFERENT ROOFING MATERIALS, WINDOW | | (GLASS TYPES), STRUCTURAL MULLIONS AND EXTERIOR DOOR | | TYPES. THESE ITEMS CAN BE DEFERRED IF REQUESTED, | | HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND APPROVED | | BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE | | INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR | | ELECTRONICALLY SUBMITTED DOCUMENTS. | | | | 3) THE PLANS INDICATE THAT THE EXISTING GARAGE DOOR IS | | BEING REPLACED WITH FRENCH DOORS. IT APPEARS THAT THE | | EXISTING GARAGE IS BEING CONVERTED INTO AN | | AIR-CONDITIONED WORK SHOP. THIS WILL NEED TO BE | | REVIEWED BY PALM BEACH COUNTY FOR IMPACT FEES. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-07-29 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-07-29 |
Time |
19:16 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-07-29 |
Time |
18:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-06-09 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-06-09 |
Time |
23:17 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-06-09 |
Time |
22:24 |
Sent To |
|
|
Notes |
2021-06-09 23:17:13 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ELECTRICAL PLAN LABELED AS "MECHANICAL PLAN". | | PROVIDE CORRECTION. FBC 107.2.1 | | | | 2. ELECTRICAL PLAN NOT CLEARLY LABELED. LABEL 1ST | | FLOOR, 2ND FLOOR ETC. FBC 107.2.1 | | | | 3. SEPARATE GARAGE STRUCTURE REQUIRES SEPARATE PERMIT. | | FBC 105.1 FBC 107.2.1 | | | | 4. SERVICE NOT SHOWN ON GARAGE STRUCTURE. PROVIDE | | CORRECTION. FBC 107.2.1 | | | | 5. NOTE ON PLAN CALLS FOR "ARC FAULT RECEPTACLES". NEC | | 210.12 STATES ELECTRICAL OUTLETS. PLEASE SEE DEFINTION | | ON OUTLET AND PROVIDE CORRECTION. ALL 15 AND 20AMP | | OUTLETS SPECIFIED IN NEC 210.12, WHICH INCLUDES | | LIGHTING MUST BE AFCI PROTECTED. | | | | 6. PROVIDE LOAD CALCULATION TO INCLUDE BOTH NEW AND | | EXISTING LOADS. NEC 220 FBC 107.2.1 | | | | 7. DISHWASHER TO BE GFCI PROTECTED PER NEC 210.8D | | | | 8. NO SMOKE/CO ALARMS SHOWN ON PLANS. PROVIDE | | CORRECTION FBC-RE 314 AND 315 | | | | 9. RECEPTACLES IN WORKSHOP TO BE GFCI PROTECTED PER NEC | | 210.8 | | | | 10. NO RECEPTACLES SHOWN ON KITCHEN ISLANDS PER NEC | | 210.52 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2021-06-11 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-06-11 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-06-11 |
Time |
16:42 |
Sent To |
|
|
Notes |
2021-06-11 16:42:51 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | SEC. 105.1. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-10-15 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-10-15 |
Time |
08:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2021-07-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-07-14 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-07-14 |
Time |
08:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-10-15 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-09-22 |
Time |
09:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-08-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-08-30 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-07-28 |
Time |
06:59 |
Sent To |
|
|
Notes |
2021-08-30 14:45:25 | HISTORIC/ZONING WILL BE REVIEWED NEXT ROUND | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-07-14 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-07-14 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-06-03 |
Time |
05:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-10-09 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-10-09 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-10-01 |
Time |
11:52 |
Sent To |
|
|
Notes |
2021-10-09 16:27:23 | NO IMPACT FEES DUE. LEM | 2021-10-01 11:54:33 | 10/01/21 EMAILED IMPACT FOR REVIEW-AO | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-07-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-02 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-02 |
Time |
17:04 |
Sent To |
|
|
Notes |
2021-07-02 17:07:24 | THE CONVERSION OF THE GARAGE TO AN AIR CONDITIONED WORK | | SHOP WILL NEED TO BE REVIEWED BY THE COUNTY. PLANS WILL | | BE REVIEWED BY THE PBC IMPACT FEE OFFICE DIGITALLY VIA | | PROJECTDOX UPON NOTIFICATION BY THIS OFFICE. | | NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST FINAL | | FORM. YOU MAY COORDINATE WITH THE IMPACT FEE OFFICE AT | | (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL IMPACT | | FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME THE | | FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM CAN | | BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT | | ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2021-06-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-11 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-06-11 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
P |
Date |
2021-10-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-10-14 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-10-14 |
Time |
09:07 |
Sent To |
|
|
Notes |
2021-10-14 09:13:52 | THE GARAGE APARTMENT IS LOCATED IN A SPECIAL FLOOD | | HAZARD AREA (AE, BFE 6' NAVD 88). ACCORDING TO THE | | APPRAISAL, THE DEPRECIATED VALUE FOR THE GARAGE | | APARTMENT (GARAGE/GUEST HOUSE) IS $124,872.00. FIFTY | | PERCENT OF THAT IS $62,436.00. THE CUMULATIVE TOTAL OF | | WORK ON THE GARAGE APARTMENT OVER THE LAST FIVE YEARS | | IS $22,357.00. FIFTY PERCENT OF THE APPRAISED VALUE | | ($62,436.00) MINUS THE PREVIOUS WORK FOR THE FIVE | | PREVIOUS YEARS ($22,357.00) IS $40,079.00. IN ORDER FOR | | THIS TO NOT BE CONSIDERED A SUBSTANTIAL IMPROVEMENT, | | THE TOTAL COST OF IMPROVEMENTS TO THE GARAGE APARTMENT | | IS REQUIRED TO BE LESS THAN $40,079.00. THE PROPOSED | | COST OF IMPROVEMENTS TO THE GARAGE APARTMENT IS | | $19,057.50. THEREFORE, THIS PROJECT IS NOT CONSIDERED A | | SUBSTANTIAL IMPROVEMENT. ANY ADDITIONAL IMPROVEMENT | | COSTS THAT MAY BE INCURRED DURING THE REMODELING OF THE | | GARAGE APARTMENT WILL BE COUNTED TOWARDS THE | | SUBSTANTIAL IMPROVEMENT LIMIT. | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2021-10-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-10-04 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-10-04 |
Time |
10:33 |
Sent To |
|
|
Notes |
2021-10-04 10:53:48 | THE EXISTING GARAGE APARTMENT IS LOCATED IN A SPECIAL | | FLOOD HAZARD AREA. DOCUMENTATION TO SHOW THIS IS NOT A | | SUBSTANTIAL IMPROVEMENT IS REQUIRED. OTHERWISE, THE | | PROJECT WILL BE REQUIRED TO SHOW COMPLIANCE WITH | | FBC-R322 AND THE CITY OF WEST PALM BEACH FLOOD | | ORDINANCE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-12-16 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-06-11 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-06-11 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
P |
Date |
2021-10-20 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2021-10-20 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2021-10-20 |
Time |
17:39 |
Sent To |
|
|
Notes |
2021-10-20 17:40:29 | PRIVATE PROVIDER INSPECTIONS ONLY APPROVED | | TEW & TAYLOR | | RICHARD GATHRIGHT |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-08-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-08-16 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-08-16 |
Time |
16:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-07-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-07-02 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-07-02 |
Time |
15:21 |
Sent To |
|
|
Notes |
2021-07-02 15:24:36 | THE STRUCTURAL SHEETS ARE MISSING THE DESIGN | | PROFESSIONAL'S DIGITAL SIGNATURES. ELECTRONICALLY | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT | | OR ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | ARCHITECT OR ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE | | AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. NO | | PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE | | ACCEPTABLE. FS 481 & 61G1 OR FS 471 & 61G15 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-10-15 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-10-15 |
Time |
08:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-07-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-07-14 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-07-14 |
Time |
08:18 |
Sent To |
|
|
Notes |
|
|