Plan Review Stops For Permit 21050951 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2021-08-18 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-08-18 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-08-18 |
Time |
07:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2021-08-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-08-16 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-08-16 |
Time |
07:44 |
Sent To |
|
|
Notes |
2021-08-16 13:44:20 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC B 107.2.1. PLEASE REVISE SUBMITTED FASTENER | | DENSITY CALCULATIONS PREPARED, SIGNED AND SEALED BY A | | FLORIDA REGISTERED PROFESSIONAL ENGINEER; TO CORRECT | | PRODUCT APPROVAL. FLORIDA DBPR PRODUCT APPROVAL | | FL16709-R6 IS THE 2017 CODE VERSION AND IS NO LONGER | | VALID. PLEASE PROVIDE A COMPLETE SET OF 2020 CODE | | VERSION (FL16709-R8) PRODUCT APPROVALS/NOA?S FOR THE | | PROPOSED FLAT ROOF SYSTEM TO BE USED. INCLUDE COVER | | PAGE, EVALUATION REPORTS AND INSTALLATION INSTRUCTIONS | | FOR SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | DRAWINGS. REVISE ENGINEER CALCULATIONS TO CORRESPOND | | WITH 2020 CODE VERSION PRODUCT APPROVALS. | | 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | HIP & RIDGE TILE ADHESIVE TO BE USED. FOURTH REQUEST. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2021-07-28 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-28 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-28 |
Time |
07:50 |
Sent To |
|
|
Notes |
2021-07-28 11:37:51 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL5680-R30 SELECTED SYSTEM NO. W-59 DO NOT | | MEET THE EXPOSURE CATEGORY D; ZONE 3 MINIMUM DESIGN | | PRESSURE REQUIREMENT. PLEASE SELECT SYSTEM NO. THAT | | MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE SIGNED AND | | SEALED ENGINEERED NAILING CALCULATIONS FOR ZONE 3. ALL | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. THE | | CORRECT EXPOSURE FOR THIS ADDRESS IS EXPOSURE D | | (-131.42). | | 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | HIP & RIDGE TILE ADHESIVE TO BE USED. THIRD REQUEST. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-07-19 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-19 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-19 |
Time |
08:06 |
Sent To |
|
|
Notes |
2021-07-19 14:06:27 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL16709-R8 SELECTED OPTION FOR SYSTEM NO W-5; | | EXPOSURE (D). THE CORRECT EXPOSURE FOR THE LISTED | | ADDRESS IS EXPOSURE D. PRODUCT APPROVAL FL16709-R8 WILL | | NOT SATISFY EXPOSURE CATEGORY D ENCLOSED AREAS WITHOUT | | USING INSULATION OR PROVIDING ENGINEERED ENHANCED | | NAILING. ANOTHER OPTION FL14672-R6. | | 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | HIP & RIDGE TILE ADHESIVE TO BE USED. SECOND REQUEST. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-07-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-13 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-13 |
Time |
07:43 |
Sent To |
|
|
Notes |
2021-07-13 09:21:55 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL16709-R8 SELECTED OPTION FOR SYSTEM NO W-5; | | EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (H<15); | | ULTIMATE WIND SPEED (170), IS NOT CORRECT. THE CORRECT | | EXPOSURE FOR THE LISTED ADDRESS IS EXPOSURE D. PLEASE | | SELECT THE CORRECT SYSTEM/OPTIONS/PRODUCT APPROVAL. | | 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | HIP & RIDGE TILE ADHESIVE TO BE USED. SECOND REQUEST. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-05-21 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-05-21 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-05-21 |
Time |
07:39 |
Sent To |
|
|
Notes |
2021-05-21 09:41:58 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | HIP & RIDGE METAL TO BE USED. | | 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | HIP & RIDGE TILE ADHESIVE TO BE USED. | | 3. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL2533-R24 SELECTED SYSTEM NO. W-84 DO NOT | | MEET THE EXPOSURE CATEGORY D; ZONE 3 MINIMUM DESIGN | | PRESSURE REQUIREMENT OF -131.42. PLEASE SELECT SYSTEM | | NO. THAT MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE | | SIGNED AND SEALED ENGINEERED NAILING CALCULATION FOR | | ZONE 3. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE | | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN | | PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-07-01 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-07-01 |
Time |
13:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2021-08-18 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-08-18 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-08-17 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2021-08-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-08-16 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-08-13 |
Time |
10:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-07-28 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-28 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-27 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-07-19 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-19 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-16 |
Time |
12:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-07-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-13 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-09 |
Time |
11:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-01 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-05-20 |
Time |
10:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2021-07-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-07-13 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-07-13 |
Time |
07:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-05-21 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2021-05-21 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2021-05-21 |
Time |
07:39 |
Sent To |
|
|
Notes |
2021-05-21 09:43:37 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | PETER VALENTI | | BUILDING PLANS EXAMINER II | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6673. | | |
|
|