Plan Review Details - Permit 21050837
Plan Review Stops For Permit 21050837 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2021-07-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-07-14 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-07-14 |
Time |
16:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-07-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-07-06 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-07-06 |
Time |
16:55 |
Sent To |
|
|
Notes |
2021-07-06 16:56:34 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | A NEW PRODUCT APPROVAL WAS UPLOADED WITH THE SAME | | DESIGN PRESSURE LIMITATION, SEE PAGE 4 OF 5. | | | | 1. DESIGN PRESSURES REQUIRED FOR 20' MEAN ROOF HEIGHT, | | EXPOSURE C,16' GARAGE DOOR IS +34.1, -37.9. THE | | PROPOSED DOOR HAS DESIGN PRESSURE LIMITATION OF +30.6, | | -34.1. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-06-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-06-21 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-06-21 |
Time |
08:33 |
Sent To |
|
|
Notes |
2021-06-21 08:34:09 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. DESIGN PRESSURES REQUIRED FOR 20' MEAN ROOF HEIGHT, | | EXPOSURE C,16' GARAGE DOOR IS +34.1, -37.9. THE | | PROPOSED DOOR HAS DESIGN PRESSURE LIMITATION OF +30.6, | | -34.1. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-06-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-06-17 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-06-17 |
Time |
12:51 |
Sent To |
|
|
Notes |
2021-06-17 12:53:41 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. DESIGN PRESSURES REQUIRED FOR 20' MEAN ROOF HEIGHT, | | EXPOSURE C,16' GARAGE DOOR IS +34.1, -37.9. THE | | PROPOSED DOOR HAS DESIGN PRESSURE LIMITATION OF +30.6, | | -34.1. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-07-14 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-07-08 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-07-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-07-06 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-06-23 |
Time |
10:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-06-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-06-21 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-06-18 |
Time |
16:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-06-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-06-17 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-06-16 |
Time |
14:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2021-06-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-06-17 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-06-17 |
Time |
12:53 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy