Plan Review Details - Permit 21050792
Plan Review Stops For Permit 21050792 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
P |
Date |
2021-09-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-09-14 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-09-14 |
Time |
11:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2021-08-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-08-04 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-08-04 16:30:28 | TO THE BUILDING CONTRACTOR: | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected] THE INFORMATION SHOULD BE IN | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | LINE. | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2021-06-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-06-23 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-06-23 |
Time |
11:02 |
Sent To |
|
|
Notes |
2021-06-23 11:21:56 | TO THE BUILDING CONTRACTOR: | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2022-01-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-01-18 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-01-18 14:58:50 | THE DESIGNER OF RECORD HAS DELETED ALL FLOOR WORK. J. | | WITMER |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2021-11-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-11-23 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-11-23 14:23:28 | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21050792 | | ADD: 400 N. FLAGLER DR. # 1705 | | CONT: LARSEN BUILDERS CORP | | TEL: 561-403-5851 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 5TH REVIEW | | DATE: TUES. NOV. 23RD/ 2021 | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | 2) 5TH REQUEST. EITHER THE CONTRACTOR AND OR DESIGN | | PROFESSIONAL NEED TO SUBMIT TEST RESULTS FOR COMMENTS | | 2A, 2B & 2C NOT A SUMMARY SHEET FOR ARMSTRONG RESILIENT | | FLOORING. QUOTING CODE SECTIONS DOES NOT MEET THE CODE | | REQUIREMENTS. | | 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION 107.2.1. W.P.B. | | ADMINISTRATIVE CODE/2020 DRAWINGS & SPECIFICATIONS | | SHALL CONTAIN INFORMATION, IN THE FORM OF NOTES OR | | OTHERWISE, AS TO THE QUALITY OF MATERIALS, WHERE | | QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL | | CODES. SUCH INFORMATION SHALL BE SPECIFIC TO THE | | TECHNICAL CODES "CODE SECTIONS SHALL NOT BE CITED AS A | | WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | THE FLOOR PLAN A-1.0 INDICATES IN THE MASTER BEDROOM, | | BEDROOM 1 & 2 ALL ARE TO RECEIVE NEW MARBLE FLOORS. | | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, | | STONE, MARBLE, VINYL AND WOOD FLOORING ALL NEED TO HAVE | | HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO | | THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH | | CONCRETE FLOOR ASSEMBLY (TEST REPORTS ARE USUALLY 4 | | PAGES FOR EACH REPORT) / NO DROPPED CEILING: | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | 2A) 5TH REQUEST. FBC-B 2020 1207.3 STRUCTURE-BORNE | | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS | | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | 2B) 5TH REQUEST. FBC-B 2020 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 2C) 5TH REQUEST. FLAME SPREAD- FBC-B 2020 603.1. | | EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 3-4) COMPLIED. | | | | 5-8) COMPLIED. WINDOW/ DOOR PERMIT 21050794. | | | | 9) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING | | FROM CITY HALL. | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2021-11-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-11-09 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-11-09 17:19:21 | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21050792 | | ADD: 400 N. FLAGLER DR. # 1705 | | CONT: LARSEN BUILDERS CORP | | TEL: 561-403-5851 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 4THREVIEW | | DATE: TUES. NOV. 09TH/ 2021 | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | 2) THE FLOOR PLAN A-1.0 INDICATES IN THE MASTER | | BEDROOM, BEDROOM 1 & 2 ALL ARE TO RECEIVE NEW MARBLE | | FLOORS. FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR | | TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL NEED | | TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR | | ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE | | QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A | | 6 INCH CONCRETE FLOOR ASSEMBLY (TEST REPORTS ARE | | USUALLY 4 PAGES FOR EACH REPORT) / NO DROPPED CEILING: | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | 2A) 4TH REQUEST. FBC-B 2020 1207.3 STRUCTURE-BORNE | | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS | | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | 2B) 4TH REQUEST. FBC-B 2020 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 2C) 4TH REQUEST. FLAME SPREAD- FBC-B 2020 603.1. | | EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 3-4) COMPLIED. | | | | 5) 4TH ROUND OF COMMENTS. PLEASE, PLEASE SUBMIT THE | | PRODUCT APPROVAL COVERSHEET AND TECHNICAL DRAWINGS IN | | THE SAME FILE FOLDER DO NOT SPLIT THEM UP INTO | | DIFFERENT FILE FOLDERS. IF THEY ARE NOT SUBMITTED | | TOGETHER FLORIDA APPROVALS DO NOT ALWAYS HAVE A | | TRACKING NUMBER ON THE TECHNICAL SHEETS. 107.2.1.2. | | ADDITIONAL INFORMATION REQUIRED. 107.2.1.3. QUALITY OF | | PLANS. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | DEPARTMENT POLICY OTHER STANDARDS FOR THE PLANS AND | | SPECIFICATIONS IN ORDER TO PROVIDE CONFORMITY TO ITS | | RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | OTHER ITEMS RELATED TO RECORD MANAGEMENT. ELECTRONIC | | MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE REQUIREMENTS | | OF FLORIDA STATUTES. | | | | 6) 4TH ROUND OF COMMENTS. IDENTIFY GLAZING/ MULLIONS. | | PLEASE IDENTIFY IN THE PRODUCT APPROVAL BEFORE | | SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION | | TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH | | GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, | | TYPE OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED | | OR REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND | | ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B | | 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE | | INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURERS | | INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE | | PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED | | BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. | | | | 7) 4TH ROUND OF COMMENTS. W. P. B. 107.3.4. PRODUCT | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY | | FLORIDA ADMINISTRATIVE CODE RULE 61G20 SHALL BE | | REVIEWED AND APPROVED IN WRITING (SHOP DRAWING STAMP OF | | APPROVAL) BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 8) COMPLIED. | | | | 9) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | RETIRED. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-09-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-09-14 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-09-14 |
Time |
11:29 |
Sent To |
|
|
Notes |
2021-09-14 13:09:32 | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21050792 | | ADD: 400 N. FLAGLER DR. # 1705 | | CONT: LARSEN BUILDERS CORP | | TEL: 561-403-5851 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: TUES. SEPT. 14TH/ 2021 | | ACTION: DENIED | | | | ***** 4X FEE / NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) | | ***** | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | 1) 2ND REQUEST. SHEET A-1.0 FLORIDA ADMINISTRATIVE CODE | | 61G15-23.005 (3)(C) A DOCUMENT IN THE FILE FOLDER, | | SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE | | OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON | | DIGITALLY SIGNED AND SEALED ENGINEERING PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | 2) THE FLOOR PLAN INDICATES IN THE MASTER BEDROOM, | | BEDROOM 1 & 2 ALL ARE TO RECEIVE NEW MARBLE FLOORS. | | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, | | STONE, MARBLE, VINYL AND WOOD FLOORING ALL NEED TO HAVE | | HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO | | THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | 2A) 2ND REQUEST. FBC-B 2020 1207.3 STRUCTURE-BORNE | | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS | | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | 2B) 2ND REQUEST. FBC-B 2020 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 2C) 2ND REQUEST. FLAME SPREAD- FBC-B 2020 603.1. | | EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 3) NO WIND DESIGN PROVIDED 2ND REVIEW. | | | | 1ST ROUND OF COMMENTS. THE SUBMITTED WIND DESIGN BY | | MANUEL SIQUES P. E. IS NOT SIGNED NOR SEALED. | | 361G15-23.002(2)(B) FL. ADMIN. CODE. A COVER SHEET WITH | | LISTED PAGES OR INDEX SHEET FOR ENGINEERING | | SPECIFICATIONS MAY BE USED AND THAT SHEET MUST BE | | SIGNED IN RESPONSIBLE CHARGE OF THE PRODUCTION & | | PREPARATION OF EACH SECTION OF THE ENGINEERING | | SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER | | SHEET OR INDEX LISTING HOW MANY PAGES ARE COVERED UNDER | | THE COVER SHEET OR INDEX SHEET. . | | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A | | DOCUMENT IN THE FILE FOLDER, SCANNED, FACSIMILE, | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE'S | | SIGNATURE SHALL NOT BE USED ON DIGITALLY SIGNED AND | | SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR | | OTHER DOCUMENTS. | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.) | | | | 4) 2ND ROUND OF COMMENTS. COULD NOT FIND THE COMPUTER | | GENERATED CALCULATIONS. | | | | 1ST ROUND COMMENTS. WITHIN THE COMPUTER-GENERATED | | PROGRAM THE INPUT OF THE EAVE HEIGHT IS GIVEN AT 185 | | FEET. PLEASE NOTE THE 1ST FLOOR AREAS ARE NOT THE | | NORMAL 8-FOOT-HIGH CEILINGS, PLUS THIS BUILDING BEING | | 23 STORIES TALL THE EAVE HEIGHT OF 185 /23 = 8.043 FEET | | TALL OR 8 FEET -0 INCH, NO ROOM FOR THE FLOOR SLABS. I | | BELIEVE THE HEIGHT CALCULATION IS OFF THAT WILL AFFECT | | THE RESULT OF THE +/ - PRESSURES SHOWN IN THE PROGRAM | | AND FLOOR PLAN. 107.2.1.2. ADDITIONAL INFORMATION IS | | REQUIRED. WE USUALLY SEE A HEIGHT OF 220 FT. FOR THIS | | BUILDING. | | | | 5) 2ND ROUND OF COMMENTS. PLEASE, PLEASE SUBMIT THE | | PRODUCT APPROVAL COVERSHEET AND TECHNICAL DRAWINGS IN | | THE SAME FILE FOLDER DO NOT SPLIT THEM UP INTO | | DIFFERENT FILE FOLDERS. IF THEY ARE NOT SUBMITTED | | TOGETHER FLORIDA APPROVALS DO NOT ALWAYS HAVE A | | TRACKING NUMBER ON THE TECHNICAL SHEETS. 107.2.1.2. | | ADDITIONAL INFORMATION REQUIRED. 107.2.1.3. QUALITY OF | | PLANS. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | DEPARTMENT POLICY OTHER STANDARDS FOR THE PLANS AND | | SPECIFICATIONS IN ORDER TO PROVIDE CONFORMITY TO ITS | | RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | OTHER ITEMS RELATED TO RECORD MANAGEMENT. ELECTRONIC | | MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE REQUIREMENTS | | OF FLORIDA STATUTES. | | | | 6) 2ND ROUND OF COMMENTS. IDENTIFY GLAZING/ MULLIONS. | | PLEASE IDENTIFY IN THE PRODUCT APPROVAL BEFORE | | SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION | | TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH | | GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, | | TYPE OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED | | OR REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND | | ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B | | 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE | | INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S | | INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE | | PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED | | BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. | | | | 7) 2ND ROUND OF COMMENTS. W. P. B. 107.3.4. PRODUCT | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY | | FLORIDA ADMINISTRATIVE CODE RULE 61G20 SHALL BE | | REVIEWED AND APPROVED IN WRITING (SHOP DRAWING STAMP OF | | APPROVAL) BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 8) 2ND ROUND OF COMMENTS. THE FLOOR PLAN IN THE | | BATHROOMS STATES NEW FIXTURES. IN BOTH THE GUEST SHOWER | | AND MASTER BATH ARE THE SHOWER WALLS AND SHOWER FLOORS | | BEING REPLACED, THE PLANS ARE NOT CLEAR ON THIS | | SUBJECT. IF SO PLEASE SHOW COMPLIANCE WITH: 2020 FBC-B | | 2509.2 BASE FOR TILE. MATERIALS USED AS A BASE FOR WALL | | TILE IN TUB AND SHOWER AREAS AND WALLS AND CEILING | | PANELS IN SHOWER AREAS SHALL BE OF MATERIALS LISTED IN | | TABLE 2509.2 AND INSTALLED IN ACCORDANCE WITH | | MANUFACTURER?S RECOMMENDATIONS. WATER RESISTANT GYPSUM | | BACKING BOARD SHALL BE USED AS A BASE FOR TILE IN WATER | | CLOSET COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE | | WITH GA-216 OR ASTM C840 AND THE MANUFACTURE?S | | RECOMMENDATIONS. | | | | 9) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | RETIRED. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-08-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-08-04 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-08-04 16:29:15 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21050792 | | ADD: 400 N. FLAGLER DR. # 1705 | | CONT: LARSEN BUILDERS CORP | | TEL: 561-403-5851 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: WED. AUGUST 4, 2021 | | ACTION: DENIED | | 1) FLOOR PLAN A-1 & A-2. FLORIDA ADMINISTRATIVE CODE | | 61G15-23.005 (3)(C) A DOCUMENT IN THE FILE FOLDER, | | SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE | | OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON | | DIGITALLY SIGNED AND SEALED ENGINEERING PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | 2) 2ND REQUEST. THE FLOOR PLAN A-1 INDICATES IN THE | | MASTER BEDROOM, BEDROOM 1 & 2 ALL ARE TO RECEIVE NEW | | MARBLE FLOORS. | | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, | | STONE, MARBLE, VINYL AND WOOD FLOORING ALL NEED TO HAVE | | HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO | | THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | 2A) 2ND REQUEST. FBC-B 2020 1207.3 STRUCTURE-BORNE | | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS | | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | 2B) 2ND REQUEST. FBC-B 2020 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 2C)2ND REQUEST. FLAME SPREAD- FBC-B 2020 603.1. | | EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 3) SEMI-COMPLIED. NEEDS DIGITAL SIGNATURE OR BRING IN | | THE ORIGINAL PAPER ORIGINAL SIGNATURE AND SEAL. | | SUBMITTED WIND DESIGN BY MANUEL SIQUES P. E. IS NOT | | SIGNED NOR SEALED. | | 361G15-23.002(2)(B) FL. ADMIN. CODE. A COVER SHEET WITH | | LISTED PAGES OR INDEX SHEET FOR ENGINEERING | | SPECIFICATIONS MAY BE USED AND THAT SHEET MUST BE | | SIGNED IN RESPONSIBLE CHARGE OF THE PRODUCTION & | | PREPARATION OF EACH SECTION OF THE ENGINEERING | | SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER | | SHEET OR INDEX LISTING HOW MANY PAGES ARE COVERED UNDER | | THE COVER SHEET OR INDEX SHEET. . | | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A | | DOCUMENT IN THE FILE FOLDER, SCANNED, FACSIMILE, | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE?S | | SIGNATURE SHALL NOT BE USED ON DIGITALLY SIGNED AND | | SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR | | OTHER DOCUMENTS. | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.) | | | | 4) COMPLIED. MEAN ROOF HEIGHT OF 220 FT. | | | | 5) COMPLIED. PRODUCT APPROVAL COVERSHEET AND TECHNICAL | | REPORT IN SAME FOLDER. | | | | 6) IDENTIFY GLAZING/ MULLIONS. SEMI-COMPLIED. PLEASE | | REVIEW SHEET A1-0 AND THE ASSOCIATED PRESSURES FOR | | OPENINGS IN WALL ZONE 4 AND WALL ZONE 5. | | | | 6A) FIXED WINDOWS. FL26095-R3 TECH SHEET 4 OF 5 | | HIGHLIGHTED PRESSURES LOW FOR ZONE 4 WHICH NEEDS =/- | | 66.97 AND ZONE 5 +66.97/ -122.79. | | | | 6B) SINGLE HUNG WINDOW FL9064-R10 PRESSURES GOOD. | | | | 6C) SLIDERS FL251-R33 DOOR SIZES AND PRESSURES PAGES | | 14-15 OF 30 NOT HIGHLIGHTED. NOTE PRESSURES ON BOTH | | PAGES ARE ONLY GOOD FOR +60/-60PSF. ZONE 4 -62.18 AND | | ZONE 5 -93.54. SILL HEIGHT MINIMUM 3 ? INCHES TO MEET + | | 59.79 PSF. | | | | 1ST ROUND OF COMMENTS. PLEASE IDENTIFY IN THE PRODUCT | | APPROVAL BEFORE SUBMITTING TO DESIGNER OF RECORD AND | | BEFORE SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL | | PRODUCTS WITH GLAZING, PLEASE IDENTIFY THE OPENING | | WIDTH & HEIGHT, TYPE OF GLAZING, MULLION SIZE, LENGTH | | IF UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED, | | ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING | | SIZE. 2020 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND | | DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED | | MANUFACTURER?S INSTRUCTIONS. FASTENER SIZE AND SPACING | | SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE | | CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN | | THE TESTS. | | | | 7) SEMI-COMPLIED, NEW PRODUCT APPROVALS WILL NEED TO BE | | REVIEWED. W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE | | PRODUCTS WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE | | CODE RULE 61G20 SHALL BE REVIEWED AND APPROVED IN | | WRITING (SHOP DRAWING STAMP OF APPROVAL) BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | 8) COMPLIED. | | | | 9) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | RETIRED. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-06-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-06-23 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-06-23 |
Time |
11:02 |
Sent To |
|
|
Notes |
2021-06-23 12:01:16 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21050792 | | ADD: 400 N. FLAGLER DR. # 1705 | | CONT: LARSEN BUILDERS CORP | | TEL: 561-403-5851 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: WED. JUNE 23RD/ 2021 | | ACTION: DENIED | | 1) FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A | | DOCUMENT IN THE FILE FOLDER, SCANNED, FACSIMILE, | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE?S | | SIGNATURE SHALL NOT BE USED ON DIGITALLY SIGNED AND | | SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR | | OTHER DOCUMENTS. | | | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | 2) THE FLOOR PLAN INDICATES IN THE MASTER BEDROOM, | | BEDROOM 1 & 2 ALL ARE TO RECEIVE NEW MARBLE FLOORS. | | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, | | STONE, MARBLE, VINYL AND WOOD FLOORING ALL NEED TO HAVE | | HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO | | THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | 2A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | 2B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, | | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR | | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E | | 90. | | | | 2C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2. | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 3) THE SUBMITTED WIND DESIGN BY MANUEL SIQUES P. E. IS | | NOT SIGNED NOR SEALED. | | 361G15-23.002(2)(B) FL. ADMIN. CODE. A COVER SHEET WITH | | LISTED PAGES OR INDEX SHEET FOR ENGINEERING | | SPECIFICATIONS MAY BE USED AND THAT SHEET MUST BE | | SIGNED IN RESPONSIBLE CHARGE OF THE PRODUCTION & | | PREPARATION OF EACH SECTION OF THE ENGINEERING | | SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER | | SHEET OR INDEX LISTING HOW MANY PAGES ARE COVERED UNDER | | THE COVER SHEET OR INDEX SHEET. . | | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A | | DOCUMENT IN THE FILE FOLDER, SCANNED, FACSIMILE, | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE?S | | SIGNATURE SHALL NOT BE USED ON DIGITALLY SIGNED AND | | SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR | | OTHER DOCUMENTS. | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.) | | | | 4) WITHIN THE COMPUTER-GENERATED PROGRAM THE INPUT OF | | THE EAVE HEIGHT IS GIVEN AT 185 FEET. PLEASE NOTE THE | | 1ST FLOOR AREAS ARE NOT THE NORMAL 8-FOOT-HIGH | | CEILINGS, PLUS THIS BUILDING BEING 23 STORIES TALL THE | | EAVE HEIGHT OF 185 /23 = 8.043 FEET TALL OR 8 FEET ? | | INCH, NO ROOM FOR THE FLOOR SLABS. I BELIEVE THE HEIGHT | | CALCULATION IS OFF THAT WILL AFFECT THE RESULT OF THE | | +/ - PRESSURES SHOWN IN THE PROGRAM AND FLOOR PLAN. | | 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED. WE | | USUALLY SEE A HEIGHT OF 220 FT. FOR THIS BUILDING. | | | | 5) PLEASE, PLEASE SUBMIT THE PRODUCT APPROVAL | | COVERSHEET AND TECHNICAL DRAWINGS IN THE SAME FILE | | FOLDER DO NOT SPLIT THEM UP INTO DIFFERENT FILE | | FOLDERS. IF THEY ARE NOT SUBMITTED TOGETHER FLORIDA | | APPROVALS DO NOT ALWAYS HAVE A TRACKING NUMBER ON THE | | TECHNICAL SHEETS. 107.2.1.2. ADDITIONAL INFORMATION | | REQUIRED. 107.2.1.3. QUALITY OF PLANS. THE BUILDING | | OFFICIAL MAY ESTABLISH THROUGH DEPARTMENT POLICY OTHER | | STANDARDS FOR THE PLANS AND SPECIFICATIONS IN ORDER TO | | PROVIDE CONFORMITY TO ITS RECORD RETENTION PROGRAM. | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | RECORD MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE | | WITH THE ARCHIVE REQUIREMENTS OF FLORIDA STATUTES. | | | | 6) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY IN THE | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, | | MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED | | INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE | | PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B 1405.13.1 | | INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN | | ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS. | | FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH | | INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM | | LOADS AND SPACING USED IN THE TESTS. | | | | 7) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE | | 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP | | DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD | | PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 8) THE FLOOR PLAN IN THE BATHROOMS STATES NEW FIXTURES. | | IN BOTH THE GUEST SHOWER AND MASTER BATH ARE THE SHOWER | | WALLS AND SHOWER FLOORS BEING REPLACED, THE PLANS ARE | | NOT CLEAR ON THIS SUBJECT. IF SO PLEASE SHOW COMPLIANCE | | WITH: 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED | | AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND | | WALLS AND CEILING PANELS IN SHOWER AREAS SHALL BE OF | | MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN | | ACCORDANCE WITH MANUFACTURER?S RECOMMENDATIONS. WATER | | RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE | | FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN | | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND | | THE MANUFACTURE?S RECOMMENDATIONS. | | | | 9) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | RETIRED. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-06-17 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2021-06-17 |
Time |
19:22 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-06-15 |
Time |
21:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2022-01-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-01-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-01-06 |
Time |
13:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2021-11-22 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-11-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-11-22 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2021-11-03 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-11-03 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-11-03 |
Time |
15:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2021-09-10 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-09-10 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-09-10 |
Time |
10:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2021-06-15 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-06-11 |
Time |
|
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2021-06-11 |
Time |
11:35 |
Sent To |
|
|
Notes |
2021-06-11 11:41:54 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1) THERE ARE INDICATIONS OF CARPET BEING REMOVED AND | | NEW TILE INSTALLED IN THE BEDROOMS; OWEVER, THERE ARE | | NO FLOOR UNDERLAYMENT OR NEW TYPE OF FLOORING | | SPECIFICATIONS SHEETS THAT INDICATE MEETING THE | | REQUIREMENTS PER NFPA' | | | | PER NFPA 101, CH 30 | | | | 30.3.3.3 INTERIOR FLOOR FINISH. | | 30.3.3.3.1 INTERIOR FLOOR FINISH SHALL COMPLY WITH | | SECTION 10.2. | | | | 30.3.3.3.3 INTERIOR FLOOR FINISH SHALL COMPLY WITH | | 10.2.7.1 OR | | 10.2.7.2, AS APPLICABLE | | | | 10.2.1.1 CLASSIFICATION OF INTERIOR FINISH MATERIALS | | SHALL BE IN | | ACCORDANCE WITH TESTS MADE UNDER CONDITIONS SIMULATING | | ACTUAL | | INSTALLATIONS, PROVIDED THAT THE AUTHORITY HAVING | | JURISDICTION IS | | PERMITTED TO ESTABLISH THE CLASSIFICATION OF ANY | | MATERIAL FOR WHICH | | CLASSIFICATION BY A STANDARD TEST IS NOT AVAILABLE, | | UNLESS OTHERWISE | | PROVIDED IN 10.2.1.2 OR 10.2.1.4. | | 10.2.1.2 THE PROVISIONS OF 10.2.1.1 SHALL NOT APPLY TO | | MATERIALS HAVING | | A TOTAL THICKNESS OF LESS THAN 1?28 IN. (0.9 MM) THAT | | ARE APPLIED DIRECTLY | | TO THE SURFACE OF WALLS AND CEILINGS WHERE BOTH OF THE | | FOLLOWING | | CONDITIONS ARE MET: | | (1) THE WALL OR CEILING SURFACE IS A NONCOMBUSTIBLE OR | | LIMITED COMBUSTIBLE | | MATERIAL. | | (2) THE MATERIALS APPLIED MEET THE REQUIREMENTS OF | | CLASS A INTERIOR | | WALL OR CEILING FINISH WHEN TESTED IN ACCORDANCE WITH | | 10.2.3, | | USING FIBER CEMENT BOARD AS THE SUBSTRATE MATERIAL. | | | | 10.2.7* INTERIOR FLOOR FINISH TESTING AND | | CLASSIFICATION. | | 10.2.7.1* CARPET AND CARPET LIKE INTERIOR FLOOR | | FINISHES SHALL | | COMPLY WITH ASTM D 2859, STANDARD TEST METHOD FOR | | IGNITION | | CHARACTERISTICS OF FINISHED TEXTILE FLOOR COVERING | | MATERIALS. | | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH | | 10.2.2.2 | | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL | | HAVE A | | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. | | | | 10.2.7.4 INTERIOR FLOOR FINISHES SHALL BE GROUPED IN | | THE CLASSES SPECIFIED | | IN 10.2.7.4.1 AND 10.2.7.4.2 IN ACCORDANCE WITH THE | | CRITICAL RADIANT FLUX | | REQUIREMENTS. | | 10.2.7.4.1 CLASS I INTERIOR FLOOR FINISH. CLASS I | | INTERIOR FLOOR FINISH | | SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN | | 0.45 W/CM2, AS DETERMINED | | BY THE TEST DESCRIBED IN 10.2.7.3. | | 10.2.7.4.2 CLASS II INTERIOR FLOOR FINISH. CLASS II | | INTERIOR FLOOR FINISH | | SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN | | 0.22 W/CM2, BUT LESS | | THAN 0.45 W/CM2, AS DETERMINED BY THE TEST DESCRIBED IN | | 10.2.7.3. | | | | PLEASE REVIEW AND PROVIDE SPEC SHEETS. | | | | | | | | 2) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2022-01-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-01-18 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-01-06 |
Time |
08:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-12-03 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-11-19 |
Time |
17:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-11-15 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2021-11-15 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-11-15 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-09-16 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-09-16 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-09-09 |
Time |
13:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-08-04 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-07-28 |
Time |
07:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-06-23 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
cdecoeur |
Date |
2021-06-04 |
Time |
08:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2021-06-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-06-23 |
Time |
11:20 |
Rev Time |
|
Received By |
jwitmer |
Date |
2021-06-23 |
Time |
11:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-01-06 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-01-06 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-01-06 08:51:39 | NO CHANGE WITH THIS CYCLE REVIEW: | | | | PRIVISO: | | PROVIDE THE COMPLETED "LIKE FOR LIKE" CHANGE OUT FORM | | AND THE AHRI SHEET FOR THE NEW AHU AND CONDENSER TO THE | | INSPECTOR AT INSPECTION. ME |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2021-06-15 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-15 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-06-15 |
Time |
13:17 |
Sent To |
|
|
Notes |
2021-06-15 13:19:20 | PRIVISO: | | PROVIDE THE COMPLETED "LIKE FOR LIKE" CHANGE OUT FORM | | AND THE AHRI SHEET FOR THE NEW AHU AND CONDENSER TO THE | | INSPECTOR AT INSPECTION. ME |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2022-01-06 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-01-06 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-01-06 |
Time |
13:46 |
Sent To |
|
|
Notes |
2022-01-06 13:47:38 | PLUMBING COMMENTS: APPROVED | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | INSPECTOR'S APPROVAL | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2021-12-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-12-03 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-12-03 |
Time |
09:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2021-11-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-11-12 |
Time |
07:13 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-01-06 |
Time |
08:55 |
Sent To |
|
|
Notes |
2021-11-12 07:14:42 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1 | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 4TH REVIEW | | | | PLUMBING COMMENTS: DENIED | | | | FOURTH REQUEST: PER WPB FBC 107.2.1, PROVIDE A SHOWER | | WALL/ LINER/THRESHOLD DETAIL SHOWING THE FOLLOWING | | INFORMATION SHOWING COMPLIANCE WITH FBC PL 421. | | | | PARTIALLY COMPLIED;SEE BELOW | | | | 1.DETAIL SHALL INCLUDE ALL COMPONENTS OF FBC PL 421.5.2 | | AS FOLLOWS: | | LINERS SHALL TURN UP ON ALL SIDES NOT LESS THAN 2 | | INCHES ABOVE THE FINISHED THRESHOLD LEVEL | | LINERS SHALL BE RECESSED AND FASTENED TO AN APPROVED | | BACKING | | LINERS SHALL NOT BE NAILED OR PERFORATED AT ANY POINT | | LESS THAN 1 INCH ABOVE THE FINISHED THRESHOLD | | LINERS SHALL BE PITCHED ONE-FOURTH UNIT VERTICAL IN 12 | | UNITS HORIZONTAL (2-PERCENT SLOPE) AND SHALL BE SLOPED | | TOWARD THE FIXTURE DRAIN | | LINERS SHALL BE SECURELY FASTENED TO THE WASTE OUTLET | | AT THE SEEPAGE ENTRANCE, MAKING A WATER-TIGHT JOINT | | BETWEEN THE LINER AND THE OUTLET | | FLOORS OR RECEPTORS UNDER SHOWER COMPARTMENTS SHALL BE | | LAID ON, AND SUPPORTED BY, A SMOOTH AND STRUCTURALLY | | SOUND BASE. | | | | 2. LINER MATERIAL (SPECIFY LINER MATERIAL COMPLYING | | WITH ONE OF THE FOLLOWING FBC PL SECTIONS-421.5.2.1, | | 421.5.2.2, 421.5.2.3, 421.5.2.4, 421.5.2.5 OR | | 421.5.2.6.) NOTE THAT FBC PL 421.5.2.1 PLASTICIZED | | POLYVINYL CHLORIDE (PVC) SHEETS MEETING THE | | REQUIREMENTS OF ASTM D4551 IS A COMMON LINER USED. | | | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | MOBILE 561-246-0882 | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | THURSDAYS | | | | 21050792 400 N FLAGLER DR # 1705 | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2021-09-16 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-09-16 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-01-06 |
Time |
08:55 |
Sent To |
|
|
Notes |
2021-09-16 15:46:39 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1 | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 3RD REVIEW | | | | PLUMBING COMMENTS: DENIED | | | | B.DEMO PLAN SPECIFICALLY INDICATES REPLACEMENT OF THE | | WATER HEATER AND BATHROOM PLUMBING FIXTURES WATER | | CLOSETS AND LAVATORIES BUT MAKE NO MENTION OF THE | | SHOWERS. HOWEVER, THE DEMO LEGEND GIVES THE APPEARANCE | | THAT THE SHOWERS ARE TO BE REPLACED AS WELL; | | ARCHITECTURAL FLOOR PLAN INDICATES REPLACEMENT OF THE | | WATER HEATER AND BATHROOM PLUMBING FIXTURES WATER | | CLOSETS AND LAVATORIES AND BOTH SHOWERS. LATEST | | PLUMBING PLAN ONLY ADDRESSES THE WATER HEATER AND ONE | | BATHROOM. | | THIRD REQUEST: PER WPB FBC 107.2.1, PLEASE CLARIFY AND | | RECONCILE ALL THREE PLANS. NEW PLUMBING PLAN INDICATES | | WORK IN HALL BATHROOM ONLY. DEMO AND FLOOR PLAN | | INDICATE MASTER BATH IS AFFECTED AS WELL. IF WORK IS TO | | BE DONE IN THE SHOWER. IF PLUMBING PLAN IS CORRECT THEN | | ARCHITECTURAL AND DEMO PLAN NEEDS TO REFLECT THE SAME. | | TO BE CLEAR, PER WPB FBC 107.2.1, ALL THREE PLANS NEED | | TO REFLECT THE SAME BEFORE APPROVAL FOR PLUMBING | | PERMIT. | | | | ...B2) THIRD REQUEST: PER WPB FBC 107.2.1, PROVIDE A | | SHOWER WALL/ LINER/THRESHOLD DETAIL SHOWING THE | | FOLLOWING INFORMATION SHOWING COMPLIANCE WITH FBC PL | | 421. | | RESPONSE IS THAT ARCHITECT TO ADDRESS. THAT WAS NOT | | DONE. APPLY TO THE BALANCE OF ALL COMMENTS BELOW. TO BE | | CLEAR, PER WPB FBC 107.2.1, APPROVAL FOR PLUMBING | | PERMIT WILL NOT BE ISSUED WITH OUT THIS INFORMATION | | BEING ON THE PLANS. | | | | .........B2A) FBC PL 421.3 WASTE OUTLETS SERVING | | SHOWERS SHALL BE NOT LESS THAN 1-1/2 INCHES (38 MM) IN | | DIAMETER AND, FOR OTHER THAN WASTE OUTLETS IN BATHTUBS, | | SHALL HAVE REMOVABLE STRAINERS NOT LESS THAN 3 INCHES | | (76 MM) IN DIAMETER WITH STRAINER OPENINGS NOT LESS | | THAN 1/4 INCH (6.4 MM) IN LEAST DIMENSION. WHERE EACH | | SHOWER SPACE IS NOT PROVIDED WITH AN INDIVIDUAL WASTE | | OUTLET, THE WASTE OUTLET SHALL BE LOCATED, AND THE | | FLOOR PITCHED SO THAT WASTE FROM ONE SHOWER DOES NOT | | FLOW OVER THE FLOOR AREA SERVING ANOTHER SHOWER. WASTE | | OUTLETS SHALL BE FASTENED TO THE WASTE PIPE IN AN | | APPROVED MANNER. | | .........B2B) FBC PL 421.4.1 BATHTUB FLOORS, SHOWER | | FLOORS, WALL AREAS ABOVE BUILT-IN TUBS THAT HAVE | | INSTALLED SHOWER HEADS AND WALLS IN SHOWER COMPARTMENTS | | SHALL BE CONSTRUCTED OF SMOOTH, CORROSION-RESISTANT AND | | NONABSORBENT WATERPROOF MATERIALS. WALL MATERIALS SHALL | | EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET (1829 MM) | | ABOVE THE ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES | | (1778 MM) ABOVE THE DRAIN OF THE TUB OR SHOWER. SUCH | | WALLS SHALL FORM A WATER-TIGHT JOINT WITH EACH OTHER | | AND WITH EITHER THE TUB OR SHOWER FLOOR. | | .........B2C) FBC PL 421.5 FLOOR SURFACES SHALL BE | | CONSTRUCTED OF IMPERVIOUS, NONCORROSIVE, NONABSORBENT | | AND WATERPROOF MATERIALS. | | .........B2D) FBC PL 421.5.1 FLOORS OR RECEPTORS UNDER | | SHOWER COMPARTMENTS SHALL BE LAID ON, AND SUPPORTED BY, | | A SMOOTH AND STRUCTURALLY SOUND BASE. | | .........B2E) FBC PL 421.5.2 FLOORS UNDER SHOWER | | COMPARTMENTS, EXCEPT WHERE PREFABRICATED RECEPTORS HAVE | | BEEN PROVIDED, SHALL BE LINED AND MADE WATER-TIGHT | | UTILIZING MATERIAL COMPLYING WITH SECTIONS 421.5.2.1 | | THROUGH 421.5.2.6 (SEE BELOW). SUCH LINERS SHALL TURN | | UP ON ALL SIDES NOT LESS THAN 2 INCHES (51 MM) ABOVE | | THE FINISHED THRESHOLD LEVEL. LINERS SHALL BE RECESSED | | AND FASTENED TO AN APPROVED BACKING SO AS NOT TO OCCUPY | | THE SPACE REQUIRED FOR WALL COVERING AND SHALL NOT BE | | NAILED OR PERFORATED AT ANY POINT LESS THAN 1 INCH (25 | | MM) ABOVE THE FINISHED THRESHOLD. LINERS SHALL BE | | PITCHED ONE-FOURTH UNIT VERTICAL IN 12 UNITS HORIZONTAL | | (2-PERCENT SLOPE) AND SHALL BE SLOPED TOWARD THE | | FIXTURE DRAINS AND BE SECURELY FASTENED TO THE WASTE | | OUTLET AT THE SEEPAGE ENTRANCE, MAKING A WATER-TIGHT | | JOINT BETWEEN THE LINER AND THE OUTLET. THE COMPLETED | | LINER SHALL BE TESTED IN ACCORDANCE WITH SECTION 312.9. | | .........B2E1) FBC PL 421.5.2.1 PLASTICIZED POLYVINYL | | CHLORIDE (PVC) SHEETS SHALL MEET THE REQUIREMENTS OF | | ASTM D4551. SHEETS SHALL BE JOINED BY SOLVENT WELDING | | IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | .........B2E2) FBC PL 421.5.2.2 NON-PLASTICIZED | | CHLORINATED POLYETHYLENE SHEET SHALL MEET THE | | REQUIREMENTS OF ASTM D4068. THE LINER SHALL BE JOINED | | IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | .........B2E3) FBC PL 421.5.2.3 SHEET LEAD SHALL WEIGH | | NOT LESS THAN 4 POUNDS PER SQUARE FOOT (19.5 KG/M2) AND | | SHALL BE COATED WITH AN ASPHALT PAINT OR OTHER APPROVED | | COATING. THE LEAD SHEET SHALL BE INSULATED FROM | | CONDUCTING SUBSTANCES OTHER THAN THE CONNECTING DRAIN | | BY 15-POUND (6.80 KG) ASPHALT FELT OR AN EQUIVALENT. | | SHEET LEAD SHALL BE JOINED BY BURNING. | | .........B2E4) FBC PL 421.5.2.4 SHEET COPPER SHALL | | CONFORM TO ASTM B152 AND SHALL WEIGH NOT LESS THAN 12 | | OUNCES PER SQUARE FOOT (3.7 KG/M2). THE COPPER SHEET | | SHALL BE INSULATED FROM CONDUCTING SUBSTANCES OTHER | | THAN THE CONNECTING DRAIN BY 15-POUND (6.80 KG) ASPHALT | | FELT OR AN EQUIVALENT. SHEET COPPER SHALL BE JOINED BY | | BRAZING OR SOLDERING. | | .........B2E5) FBC PL 421.5.2.5 SHEET-APPLIED, LOAD | | BEARING, BONDED, WATERPROOF MEMBRANES SHALL MEET | | REQUIREMENTS OF ANSI A118.10 AND SHALL BE APPLIED IN | | ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | .........B2E6) FBC PL 421.5.2.6L LIQUID-TYPE, | | TROWEL-APPLIED, LOAD BEARING, BONDED WATERPROOF | | MATERIALS SHALL MEET THE REQUIREMENTS OF ANSI A118.10 | | AND SHALL BE APPLIED IN ACCORDANCE WITH THE | | MANUFACTURER'S INSTRUCTIONS. | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | MOBILE 561-246-0882 | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | THURSDAYS | | | | 21050792 400 N FLAGLER DR # 1705 | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2021-07-29 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2021-07-29 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2021-07-29 |
Time |
16:51 |
Sent To |
|
|
Notes |
2021-07-29 16:59:14 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1 | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 2ND REVIEW | | | | PLUMBING COMMENTS: DENIED | | | | A. COMPLIED | | B.DEMO PLAN SPECIFICALLY INDICATES REPLACEMENT OF THE | | WATER HEATER AND BATHROOM PLUMBING FIXTURES WATER | | CLOSETS AND LAVATORIES BUT MAKE NO MENTION OF THE | | SHOWERS. HOWEVER, THE DEMO LEGEND GIVES THE APPEARANCE | | THAT THE SHOWERS ARE TO BE REPLACED AS WELL; | | ARCHITECTURAL FLOOR PLAN INDICATES REPLACEMENT OF THE | | WATER HEATER AND BATHROOM PLUMBING FIXTURES WATER | | CLOSETS AND LAVATORIES AND ONE SHOWER. PLUMBING PLAN | | ONLY ADDRESSES THE WATER HEATER. | | SECOND REQUEST: PER WPB FBC 107.2.1, PLEASE CLARIFY AND | | RECONCILE ALL THREE PLANS. NEW PLUMBING PLAN INDICATES | | WORK IN HALL BATHROOM ONLY. DEMO AND FLOOR PLAN | | INDICATE MASTER BATH IS AFFETED AS WELL. IF WORK IS TO | | BE DONE IN THE SHOWER, INDICATE THE SCOPE AND PROVIDE | | ON THE PLUMBING PLAN THE FOLLOWING: | | | | ...B1) COMPLIED | | | | ...B2) PROVIDE A SHOWER WALL/DRAIN AND THRESHOLD DETAIL | | SHOWING THE FOLLOWING INFORMATION SHOWING COMPLIANCE | | WITH FBC PL 421 | | RESPONSE IS THAT ARCHITECT TO ADDRESS. THAT WAS NOT | | DONE. APPLY TO THE BALANCE OF ALL COMMENTS BELOW. | | | | .........B2A) FBC PL 421.3 WASTE OUTLETS SERVING | | SHOWERS SHALL BE NOT LESS THAN 1-1/2 INCHES (38 MM) IN | | DIAMETER AND, FOR OTHER THAN WASTE OUTLETS IN BATHTUBS, | | SHALL HAVE REMOVABLE STRAINERS NOT LESS THAN 3 INCHES | | (76 MM) IN DIAMETER WITH STRAINER OPENINGS NOT LESS | | THAN 1/4 INCH (6.4 MM) IN LEAST DIMENSION. WHERE EACH | | SHOWER SPACE IS NOT PROVIDED WITH AN INDIVIDUAL WASTE | | OUTLET, THE WASTE OUTLET SHALL BE LOCATED, AND THE | | FLOOR PITCHED SO THAT WASTE FROM ONE SHOWER DOES NOT | | FLOW OVER THE FLOOR AREA SERVING ANOTHER SHOWER. WASTE | | OUTLETS SHALL BE FASTENED TO THE WASTE PIPE IN AN | | APPROVED MANNER. | | .........B2B) FBC PL 421.4.1 BATHTUB FLOORS, SHOWER | | FLOORS, WALL AREAS ABOVE BUILT-IN TUBS THAT HAVE | | INSTALLED SHOWER HEADS AND WALLS IN SHOWER COMPARTMENTS | | SHALL BE CONSTRUCTED OF SMOOTH, CORROSION-RESISTANT AND | | NONABSORBENT WATERPROOF MATERIALS. WALL MATERIALS SHALL | | EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET (1829 MM) | | ABOVE THE ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES | | (1778 MM) ABOVE THE DRAIN OF THE TUB OR SHOWER. SUCH | | WALLS SHALL FORM A WATER-TIGHT JOINT WITH EACH OTHER | | AND WITH EITHER THE TUB OR SHOWER FLOOR. | | .........B2C) FBC PL 421.5 FLOOR SURFACES SHALL BE | | CONSTRUCTED OF IMPERVIOUS, NONCORROSIVE, NONABSORBENT | | AND WATERPROOF MATERIALS. | | .........B2D) FBC PL 421.5.1 FLOORS OR RECEPTORS UNDER | | SHOWER COMPARTMENTS SHALL BE LAID ON, AND SUPPORTED BY, | | A SMOOTH AND STRUCTURALLY SOUND BASE. | | .........B2E) FBC PL 421.5.2 FLOORS UNDER SHOWER | | COMPARTMENTS, EXCEPT WHERE PREFABRICATED RECEPTORS HAVE | | BEEN PROVIDED, SHALL BE LINED AND MADE WATER-TIGHT | | UTILIZING MATERIAL COMPLYING WITH SECTIONS 421.5.2.1 | | THROUGH 421.5.2.6 (SEE BELOW). SUCH LINERS SHALL TURN | | UP ON ALL SIDES NOT LESS THAN 2 INCHES (51 MM) ABOVE | | THE FINISHED THRESHOLD LEVEL. LINERS SHALL BE RECESSED | | AND FASTENED TO AN APPROVED BACKING SO AS NOT TO OCCUPY | | THE SPACE REQUIRED FOR WALL COVERING AND SHALL NOT BE | | NAILED OR PERFORATED AT ANY POINT LESS THAN 1 INCH (25 | | MM) ABOVE THE FINISHED THRESHOLD. LINERS SHALL BE | | PITCHED ONE-FOURTH UNIT VERTICAL IN 12 UNITS HORIZONTAL | | (2-PERCENT SLOPE) AND SHALL BE SLOPED TOWARD THE | | FIXTURE DRAINS AND BE SECURELY FASTENED TO THE WASTE | | OUTLET AT THE SEEPAGE ENTRANCE, MAKING A WATER-TIGHT | | JOINT BETWEEN THE LINER AND THE OUTLET. THE COMPLETED | | LINER SHALL BE TESTED IN ACCORDANCE WITH SECTION 312.9. | | .........B2E1) FBC PL 421.5.2.1 PLASTICIZED POLYVINYL | | CHLORIDE (PVC) SHEETS SHALL MEET THE REQUIREMENTS OF | | ASTM D4551. SHEETS SHALL BE JOINED BY SOLVENT WELDING | | IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | .........B2E2) FBC PL 421.5.2.2 NON-PLASTICIZED | | CHLORINATED POLYETHYLENE SHEET SHALL MEET THE | | REQUIREMENTS OF ASTM D4068. THE LINER SHALL BE JOINED | | IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | .........B2E3) FBC PL 421.5.2.3 SHEET LEAD SHALL WEIGH | | NOT LESS THAN 4 POUNDS PER SQUARE FOOT (19.5 KG/M2) AND | | SHALL BE COATED WITH AN ASPHALT PAINT OR OTHER APPROVED | | COATING. THE LEAD SHEET SHALL BE INSULATED FROM | | CONDUCTING SUBSTANCES OTHER THAN THE CONNECTING DRAIN | | BY 15-POUND (6.80 KG) ASPHALT FELT OR AN EQUIVALENT. | | SHEET LEAD SHALL BE JOINED BY BURNING. | | .........B2E4) FBC PL 421.5.2.4 SHEET COPPER SHALL | | CONFORM TO ASTM B152 AND SHALL WEIGH NOT LESS THAN 12 | | OUNCES PER SQUARE FOOT (3.7 KG/M2). THE COPPER SHEET | | SHALL BE INSULATED FROM CONDUCTING SUBSTANCES OTHER | | THAN THE CONNECTING DRAIN BY 15-POUND (6.80 KG) ASPHALT | | FELT OR AN EQUIVALENT. SHEET COPPER SHALL BE JOINED BY | | BRAZING OR SOLDERING. | | .........B2E5) FBC PL 421.5.2.5 SHEET-APPLIED, LOAD | | BEARING, BONDED, WATERPROOF MEMBRANES SHALL MEET | | REQUIREMENTS OF ANSI A118.10 AND SHALL BE APPLIED IN | | ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | .........B2E6) FBC PL 421.5.2.6L LIQUID-TYPE, | | TROWEL-APPLIED, LOAD BEARING, BONDED WATERPROOF | | MATERIALS SHALL MEET THE REQUIREMENTS OF ANSI A118.10 | | AND SHALL BE APPLIED IN ACCORDANCE WITH THE | | MANUFACTURER'S INSTRUCTIONS. | | | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | MOBILE 561-246-0882 | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | THURSDAYS | | | | 21050792 400 N FLAGLER DR # 1705 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-06-17 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2021-06-17 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-01-06 |
Time |
13:46 |
Sent To |
|
|
Notes |
2021-06-17 09:20:41 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1 | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 1ST REVIEW | | | | PLUMBING COMMENTS: DENIED | | | | A. WATER HEATER DETAIL; LACKS THERMAL EXPANSION DEVICE | | AND HEATER PAN. PER WPB FBC 107.2.1, SHOW AND SPECIFY A | | SIZED THERMAL EXPANSION DEVICE AS REQUIRED BY FBC PL | | 607.3. IT IS NOTED THAT PER FBC PL 504.7.2 A PAN IS NOT | | REQUIRED FOR A REPLACEMENT WATER HEATER IF A PAN WAS | | NOT PREVIOUSLY INSTALLED. PER WPB FBC 107.2.1, PROVIDE | | NOTE ON THE PLAN IF A HEATER PAN WAS NOT PREVIOUSLY | | INSTALLED; OTHERWISE PROVIDE A PAN AND DRAIN PER FBC PL | | 504.7.1. | | | | B. DEMO PLAN SPECIFICALLY INDICATES REPLACEMENT OF THE | | WATER HEATER AND BATHROOM PLUMBING FIXTURES WATER | | CLOSETS AND LAVATORIES BUT MAKE NO MENTION OF THE | | SHOWERS. HOWEVER, THE DEMO LEGEND GIVES THE APPEARANCE | | THAT THE SHOWERS ARE TO BE REPLACED AS WELL; | | ARCHITECTURAL FLOOR PLAN INDICATES REPLACEMENT OF THE | | WATER HEATER AND BATHROOM PLUMBING FIXTURES WATER | | CLOSETS AND LAVATORIES AND ONE SHOWER. PLUMBING PLAN | | ONLY ADDRESSES THE WATER HEATER. PER WPB FBC 107.2.1, | | PLEASE CLARIFY AND RECONCILE ALL THREE PLANS. IF WORK | | IS TO BE DONE IN THE SHOWER, INDICATE THE SCOPE AND | | PROVIDE ON THE PLUMBING PLAN THE FOLLOWING: | | ...B1) SHOWER VALVE SPECIFICATION; SHALL COMPLY WITH | | FBC PL 412.3, WHICH SHALL BE PRESSURE BALANCED PB, | | THERMOSTATIC MIXING (TM) OR COMBINATION PB/TM VALVE | | TYPES WITH HIGH TEMPERATURE LIMITING STOP THAT CONFORM | | TO THE REQUIREMENTS OF ASSE 1016/ASME A112.1016/CSA | | B125.16 OR ASME A112.18.1/CSA B125.1 AND SHALL BE | | INSTALLED AT THE POINT OF USE. | | ...B2) PROVIDE A SHOWER WALL/DRAIN AND THRESHOLD DETAIL | | SHOWING THE FOLLOWING INFORMATION SHOWING COMPLIANCE | | WITH FBC PL 421 | | .........B2A) FBC PL 421.3 WASTE OUTLETS SERVING | | SHOWERS SHALL BE NOT LESS THAN 1-1/2 INCHES (38 MM) IN | | DIAMETER AND, FOR OTHER THAN WASTE OUTLETS IN BATHTUBS, | | SHALL HAVE REMOVABLE STRAINERS NOT LESS THAN 3 INCHES | | (76 MM) IN DIAMETER WITH STRAINER OPENINGS NOT LESS | | THAN 1/4 INCH (6.4 MM) IN LEAST DIMENSION. WHERE EACH | | SHOWER SPACE IS NOT PROVIDED WITH AN INDIVIDUAL WASTE | | OUTLET, THE WASTE OUTLET SHALL BE LOCATED, AND THE | | FLOOR PITCHED SO THAT WASTE FROM ONE SHOWER DOES NOT | | FLOW OVER THE FLOOR AREA SERVING ANOTHER SHOWER. WASTE | | OUTLETS SHALL BE FASTENED TO THE WASTE PIPE IN AN | | APPROVED MANNER. | | .........B2B) FBC PL 421.4.1 BATHTUB FLOORS, SHOWER | | FLOORS, WALL AREAS ABOVE BUILT-IN TUBS THAT HAVE | | INSTALLED SHOWER HEADS AND WALLS IN SHOWER COMPARTMENTS | | SHALL BE CONSTRUCTED OF SMOOTH, CORROSION-RESISTANT AND | | NONABSORBENT WATERPROOF MATERIALS. WALL MATERIALS SHALL | | EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET (1829 MM) | | ABOVE THE ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES | | (1778 MM) ABOVE THE DRAIN OF THE TUB OR SHOWER. SUCH | | WALLS SHALL FORM A WATER-TIGHT JOINT WITH EACH OTHER | | AND WITH EITHER THE TUB OR SHOWER FLOOR. | | .........B2C) FBC PL 421.5 FLOOR SURFACES SHALL BE | | CONSTRUCTED OF IMPERVIOUS, NONCORROSIVE, NONABSORBENT | | AND WATERPROOF MATERIALS. | | .........B2D) FBC PL 421.5.1 FLOORS OR RECEPTORS UNDER | | SHOWER COMPARTMENTS SHALL BE LAID ON, AND SUPPORTED BY, | | A SMOOTH AND STRUCTURALLY SOUND BASE. | | .........B2E) FBC PL 421.5.2 FLOORS UNDER SHOWER | | COMPARTMENTS, EXCEPT WHERE PREFABRICATED RECEPTORS HAVE | | BEEN PROVIDED, SHALL BE LINED AND MADE WATER-TIGHT | | UTILIZING MATERIAL COMPLYING WITH SECTIONS 421.5.2.1 | | THROUGH 421.5.2.6 (SEE BELOW). SUCH LINERS SHALL TURN | | UP ON ALL SIDES NOT LESS THAN 2 INCHES (51 MM) ABOVE | | THE FINISHED THRESHOLD LEVEL. LINERS SHALL BE RECESSED | | AND FASTENED TO AN APPROVED BACKING SO AS NOT TO OCCUPY | | THE SPACE REQUIRED FOR WALL COVERING AND SHALL NOT BE | | NAILED OR PERFORATED AT ANY POINT LESS THAN 1 INCH (25 | | MM) ABOVE THE FINISHED THRESHOLD. LINERS SHALL BE | | PITCHED ONE-FOURTH UNIT VERTICAL IN 12 UNITS HORIZONTAL | | (2-PERCENT SLOPE) AND SHALL BE SLOPED TOWARD THE | | FIXTURE DRAINS AND BE SECURELY FASTENED TO THE WASTE | | OUTLET AT THE SEEPAGE ENTRANCE, MAKING A WATER-TIGHT | | JOINT BETWEEN THE LINER AND THE OUTLET. THE COMPLETED | | LINER SHALL BE TESTED IN ACCORDANCE WITH SECTION 312.9. | | .........B2E1) FBC PL 421.5.2.1 PLASTICIZED POLYVINYL | | CHLORIDE (PVC) SHEETS SHALL MEET THE REQUIREMENTS OF | | ASTM D4551. SHEETS SHALL BE JOINED BY SOLVENT WELDING | | IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | .........B2E2) FBC PL 421.5.2.2 NON-PLASTICIZED | | CHLORINATED POLYETHYLENE SHEET SHALL MEET THE | | REQUIREMENTS OF ASTM D4068. THE LINER SHALL BE JOINED | | IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | .........B2E3) FBC PL 421.5.2.3 SHEET LEAD SHALL WEIGH | | NOT LESS THAN 4 POUNDS PER SQUARE FOOT (19.5 KG/M2) AND | | SHALL BE COATED WITH AN ASPHALT PAINT OR OTHER APPROVED | | COATING. THE LEAD SHEET SHALL BE INSULATED FROM | | CONDUCTING SUBSTANCES OTHER THAN THE CONNECTING DRAIN | | BY 15-POUND (6.80 KG) ASPHALT FELT OR AN EQUIVALENT. | | SHEET LEAD SHALL BE JOINED BY BURNING. | | .........B2E4) FBC PL 421.5.2.4 SHEET COPPER SHALL | | CONFORM TO ASTM B152 AND SHALL WEIGH NOT LESS THAN 12 | | OUNCES PER SQUARE FOOT (3.7 KG/M2). THE COPPER SHEET | | SHALL BE INSULATED FROM CONDUCTING SUBSTANCES OTHER | | THAN THE CONNECTING DRAIN BY 15-POUND (6.80 KG) ASPHALT | | FELT OR AN EQUIVALENT. SHEET COPPER SHALL BE JOINED BY | | BRAZING OR SOLDERING. | | .........B2E5) FBC PL 421.5.2.5 SHEET-APPLIED, LOAD | | BEARING, BONDED, WATERPROOF MEMBRANES SHALL MEET | | REQUIREMENTS OF ANSI A118.10 AND SHALL BE APPLIED IN | | ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | .........B2E6) FBC PL 421.5.2.6L LIQUID-TYPE, | | TROWEL-APPLIED, LOAD BEARING, BONDED WATERPROOF | | MATERIALS SHALL MEET THE REQUIREMENTS OF ANSI A118.10 | | AND SHALL BE APPLIED IN ACCORDANCE WITH THE | | MANUFACTURER'S INSTRUCTIONS. | | | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | MOBILE 561-246-0882 | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | THURSDAYS | | | | 21050792 400 N FLAGLER DR # 1705 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
6 |
Status |
P |
Date |
2022-01-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-01-18 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
F |
Date |
2021-11-23 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2021-11-23 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-11-23 |
Time |
10:43 |
Sent To |
|
|
Notes |
2021-11-23 10:40:51 | PAPER PLANS LABELED "D-1, A-1, A-2, AND P-1 " WERE | | SUBMITTED ON 11/19/2021 WITH A WET SIGNATURE AND SEAL. | | | | PLANS LABELED "E-1 AND M-1" WERE NOT SUBMITTED WITH | | PAPER PLANS ON 11/19/2021. | | | | PLANS LABELED 'E-1 AND M-1" IN PROJECT DOX ARE COPIES | | OF SEALS AND SIGNATURES. | | | | CORRECT BY SUBMITTING PROPERLY SIGNED AND SEALED PLANS | | LABELED "E-1" AND "M-1" AS OUTLINED BELOW | | | | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY SEALED AND | | SIGNED. | | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION. | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | DOCUMENTS ARE PREFERRED. | | | | PLEASE EMAIL [email protected] AND CC TO | | [email protected] | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2021-11-15 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2021-11-15 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-11-15 |
Time |
14:57 |
Sent To |
|
|
Notes |
2021-11-15 15:26:51 | PLANS LABELED E 1 AND M1 APPEAR TO BE COPIES OF | | ORIGINAL SEALED AND SIGNED DRAWINGS. ALL OTHER DRAWINGS | | APPEAR TO BE DIGITALLY SEALED AND SIGNED, HOWEVER, THE | | SIGNATURE FROM THE ENGINEER OF RECORD APPEARS TO BE | | SELF AUTHORIZED SIGNATURES. PROFESSIONAL ENGINEERS ARE | | REQUIRE TO HAVE THEIR IDENTITY AUTHENTICATED BY A | | CERTIFICATION AUTHORITY . F.A.C 61G15?23.004 | | | | PLEASE CORRECT THESE ISSUES FOLLOWING THE DIRECTIONS | | BELOW | | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION. | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | DOCUMENTS ARE PREFERRED. | | | | PLEASE EMAIL [email protected] AND CC TO | | [email protected] | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2021-09-16 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-09-16 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-09-16 |
Time |
15:47 |
Sent To |
|
|
Notes |
2021-09-16 15:48:21 | CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTI | | | | SIGNATURE REVIEW DENIED: | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL | | SIGNED/SEALED PAPER ORIGINAL TO: | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-08-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-08-04 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-08-04 16:32:35 | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A | | DOCUMENT IN THE FILE FOLDER, SCANNED, FACSIMILE, | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE?S | | SIGNATURE SHALL NOT BE USED ON DIGITALLY SIGNED AND | | SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR | | OTHER DOCUMENTS. | | | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-06-15 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-15 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-06-15 |
Time |
13:23 |
Sent To |
|
|
Notes |
2021-06-15 13:25:48 | THE DRAWINGS ARE HAND STAMPED AND SGNED BUT SUBMITTED | | DIGITALLY. WE CAN NOT VERIFY THE STAMP OR SIGNATURE. | | PLEASE BRING THE ORIGINAL SIGNED AND SEALED PAPER | | DRAWINGS TO OUR OFFICE OR PROVIDE DIGITALLY SIGNED | | DRAWINGS. | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
|