2021-05-27 10:42:47 | FAILED |
| |
| SIGN 1 - FASCIA IDENTITY SIGN |
| |
| THE ROSEMARY SQUARE SIGN CRITERIA MEASURES SIGNAGE |
| ALLOWANCE AS FOLLOWS - ONE SQUARE FOOT OF SIGNAGE FOR |
| EACH ONE LINEAR FOOT OF STORE FRONTAGE. PLEASE PROVIDE |
| THE LINEAR FEET OF STORE FRONTAGE. ADDITIONAL COMMENTS |
| MAY BE FORTHCOMING ONCE THE LINEAR FRONTAGE DIMENSION |
| IS PROVIDED. |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA FOR STOREFRONT |
| TYPE 1 ONLY ALLOWS A FASCIA IDENTITY SIGN TO BE |
| INSTALLED ON A CASE BY CASE BASIS. CITYPLACE RETAIL |
| MUST SPECIFICALLY PROVIDE WRITTEN APPROVAL OF A WAIVER |
| I TO ALLOW THE CASE BY CASE USE OF A FASCIA IDENTITY |
| SIGN AT THIS LOCATION. A WAIVER I ALLOWING THE FASCIA |
| IDENTITY SIGN WAS NOT PROVIDED. |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A |
| MAXIMUM LETTER HEIGHT OF 18 INCHES FOR A FASCIA |
| IDENTITY SIGN UNLESS CITYPLACE RETAIL SUBMITS AND IS |
| GRANTED WAIVER II (MINOR PLANNED DEVELOPMENT |
| AMENDMENT). THE WAIVER II MAY INCREASE THE SIGNS |
| DIMENSION BY UP TO 25 PERCENT, SO THE LETTER HEIGHT |
| COULD BE UP TO 22.5 INCHES. THE SIGN LETTERS ARE SHOWN |
| AT 24.5 INCHES IN HEIGHT, WHICH EXCEEDS THE WAIVABLE |
| LETTER HEIGHT BY 2 INCHES. |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THAT |
| THE SIGN COPY AREA SHALL MAINTAIN A MARGIN AT LEAST |
| THREE (3) INCHES FROM ANY EDGE OF THE PERCEIVED SIGN |
| AREA. PROVIDE THE DIMENSION ABOVE AND BELOW THE SIGN |
| TEXT THAT VERIFIES THE THREE-INCH MARGIN (EQ IS NOT |
| ACCEPTABLE). |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A |
| FASCIA IDENTITY SIGN TO BE A MAXIMUM OF 16 FEET FROM |
| FINISHED FLOOR GRADE. PLEASE PROVIDE A CLEAR DIMENSION |
| LINE SHOWING THAT THIS CRITERIA IS MET. |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE |
| STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR |
| BOLTS. PROVIDE VERIFICATION OF THIS REQUIREMENT ON THE |
| PLANS. |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE ALL |
| CONDUIT, RACEWAYS, WIRING, BALLAST BOXES, TRANSFORMERS, |
| JUNCTION BOXES, BELL BOXES, POWER SUPPLY AND OTHER |
| EQUIPMENT NECESSARY FOR SIGN CONNECTION SHALL BE |
| CONCEALED AND NOT VISIBLE TO THE PUBLIC. THE PERMIT |
| DRAWINGS NEED TO PROVIDE DETAILED DRAWINGS VERIFYING |
| THAT ALL THE ELECTRICAL COMPONENTS FOR THE SIGN, |
| INCLUDING THE POWER SUPPLY AND THE COMPONENTS TO GET |
| THE POWER TO THE SIGN ARE CONCEALED. A NOTE SAYING THAT |
| THEY WILL BE CONCEALED OR THAT THE ELECTRIC IS BY |
| OTHERS IS NOT ACCEPTABLE AND WILL RESULT IN THE SIGN |
| PERMIT NOT PASSING ZONING. THE DRAWING ON PAGE 7 |
| STATING "REMOTE LED POWER SUPPLY" IS NOT ACCEPTABLE. |
| |
| PERMITTED: UNKNOWN |
| PROPOSED: UNKNOWN |
| |
| SIGNS 4 & 5 - CEILING MOUNTED BLADE SIGNS |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA ONLY PERMIT A |
| STORE TO HAVE ONE BLADE SIGN UNLESS IT IS A CORNER |
| LOCATION. THE WEST ELM SPACE IS NOT A CORNER LOCATION, |
| SO YOU MAY ONLY INSTALL ONE BLADE SIGN. THE ROSEMARY |
| SQUARE TENANT SIGN CRITERIA DO NOT PERMIT A WAIVER OF |
| THE NUMBER OF BLADE SIGNS. |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRES THAT |
| SUSPENDED BLADE SIGN PANELS SHALL BE CENTERED IN THE |
| ARCADE CEILING. PROVIDE A DRAWING THAT VERIFIES THIS |
| CRITERIA. |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT BLADE |
| SIGNS TO BE CONSTRUCTED WITH PUSH-THROUGH WHITE ACRYLIC |
| LETTERS WITH HALO ILLUMINATION. THE PROPOSED PLANS CALL |
| FOR CLEAR PLEX WITH A WHITE TRANSLUCENT VINYL OVERLAY. |
| THIS USE OF ALTERNATIVE MATERIALS ON THE SIGN REQUIRES |
| A WAIVER I WRITTEN APPROVAL FROM CITYPLACE RETAIL TO BE |
| SUBMITTED WITH THE PERMIT. |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE ALL |
| CONDUIT, RACEWAYS, WIRING, BALLAST BOXES, TRANSFORMERS, |
| JUNCTION BOXES, BELL BOXES, POWER SUPPLY AND OTHER |
| EQUIPMENT NECESSARY FOR SIGN CONNECTION SHALL BE |
| CONCEALED AND NOT VISIBLE TO THE PUBLIC. THE PERMIT |
| DRAWINGS NEED TO PROVIDE DETAILED DRAWINGS VERIFYING |
| THAT ALL THE ELECTRICAL COMPONENTS FOR THE SIGN, |
| INCLUDING THE COMPONENTS TO GET THE POWER TO THE SIGN |
| ARE CONCEALED. A NOTE SAYING THAT THEY WILL BE |
| CONCEALED OR THAT THE ELECTRIC IS BY OTHERS IS NOT |
| ACCEPTABLE AND WILL RESULT IN THE SIGN PERMIT NOT |
| PASSING ZONING. |
| |
| SIGN 6 - WINDOW GRAPHICS |
| |
| APPROVED BY ZONING. |
| |
| SIGN 7 - WINDOW GRAPHICS |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA LIMITS THE |
| SIGN COPY TO TRADE NAMES ONLY. THE SLOGAN "SHARE YOUR |
| STYLE" REQUIRES A WAIVER I WRITTEN APPROVAL FROM |
| CITYPLACE RETAIL TO BE SUBMITTED WITH THE PERMIT. |
| |
| SIGN 8 - SIGN AT REAR ENTRANCE IS CONSIDERED AN |
| UNREGULATED SIGN AND DOES NOT REQUIRE ZONING |
| REVIEW/APPROVAL. |
| |